INA111BU סקירה

The Texas Instruments INA111BU is a single-channel, high-speed, FET-input instrumentation amplifier with a 2 MHz gain-bandwidth product, 17 V/us slew rate, and 106 dB CMRR. It operates from 6 V to 18 V and is supplied in a 16-pin SOIC package for surface-mount instrumentation and signal-conditioning systems.

An instrumentation amplifier is a specialized analog amplifier designed to amplify small differential signals while rejecting common-mode noise and interference. Its typical signal path includes input buffers, a differential amplifier stage, and gain-setting elements. This three-op-amp topology belongs to the broader operational-amplifier hierarchy and is commonly used where sensor outputs, sensor inputs, and instrumentation need accurate differential measurement without excessive front-end complexity.

The INA111BU uses FET inputs to reduce input bias current to less than 20 pA. This low-bias-current characteristic simplifies input filtering and limits circuitry around high-impedance sources. Its 2 MHz bandwidth supports higher-bandwidth measurement than precision-only instrumentation amplifiers, while the 17 V/us slew rate helps preserve large-signal response when operating at higher gains. The specified 106 dB CMRR supports effective rejection of common-mode voltage in industrial and test environments.

The device accepts a 6 V to 18 V supply range and is specified from -40 C to +85 C. The 16-pin SOIC package provides a practical surface-mount option for acquisition boards, process-control equipment, medical instrumentation, and laboratory measurement systems. Pin assignments and recommended gain-setting component values should be taken directly from the pin-description and application circuits in the manufacturer datasheet.

INA111BU is suited to bridge sensors, current shunts, precision current measurement, and low-level differential signal acquisition. The principal design trade-off is the relationship between closed-loop gain, bandwidth, output swing, and input common-mode range. Designers should confirm those limits for the intended gain and supply voltage before committing the PCB layout.

This page combines the manufacturer product information with a structured technical comparison, practical design notes, verified source links, and identified replacement constraints. Use the Request a Quote form on this page for current commercial availability, lot-specific packaging, and sourcing requirements.

חלופות תחליף ישיר עבור INA111BU — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.

וריאנטים בסדרה זו

דגמים מאותה סדרה התואמים Drop-in עם INA111BU (אותו גורם צורה וטביעת רגל) — שונים ב Product Type, Supply Voltage Range, Package, Slew Rate, Architecture.

Texas Instruments
Product Type: Monolithic FET-input instrumentation amplifier
Supply Voltage Range: 12 V to 36 V
Package: 16-pin SOIC (SOL-16)
השווה עם INA111BU →
Texas Instruments
Product Type: Low-cost, general-purpose precision instrumentation amplifier
Supply Voltage Range: 2.25 V to 18 V
Slew Rate: 0.06 V/µs
השווה עם INA111BU →

INA111BUE4

✅ Drop-In
📦 16-pin SOIC
Same INA111 family and 2 MHz bandwidth; order-suffix attributes require confirmation

📋 חלופה להתייחסות (לא בקטלוג)

INA114BU

✅ Drop-In
Texas Instruments
📦 16-pin SOIC
Precision instrumentation amplifier · Three-op-amp design · 1 circuit · 1 MHz · 50 uV · 11 nV/√Hz · 3 mA · 1 to 10,000

צור קשר לקבלת מחיר

הצג גיליון נתונים ←

INA114AUE4

✅ Drop-In
📦 16-pin SOIC
Same 16-pin SOIC package; precision-oriented gain configuration replaces the 2 MHz high-speed emphasis

📋 חלופה להתייחסות (לא בקטלוג)

INA111BU דירוגים מרביים ומאפיינים חשמליים

Product Type Instrumentation amplifier
Number of Amplifiers 1 circuit
Input Transistor Type FET-input
Gain-Bandwidth Product 2 MHz
Slew Rate 17 V/us
Common-Mode Rejection Ratio 106 dB
Input Bias Current Less than 20 pA
Supply Voltage Range 6 V to 18 V
Maximum Supply Voltage 18 V
טווח טמפרטורת פעולה -40 C to +85 C
מארז 16-pin SOIC
סוג הרכבה Surface mount
AEC-Q100 Qualification Not applicable

מדריך תצורת פינים של INA111BU 16-pin soic

תצורת פינים עבור INA111BU (מארזת 16-pin soic). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.

תרשים פינים של מארזת 16-pin soic עבור INA111BU

אין נתוני פריסת פינים מפורטים עבור INA111BU.

עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.

יישומים טיפוסיים

INA111BU מתאים עבור 6 יישוםs: Bridge Sensor Signal Conditioning, Shunt-Based Current Measurement, Precision Data Acquisition, Laboratory Instrumentation, Process Control Monitoring, Medical Signal Acquisition.

🏭

Bridge Sensor Signal Conditioning

The INA111BU fits differential bridge measurements where small sensor outputs must be amplified in the presence of a larger common-mode voltage. Its FET inputs draw less than 20 pA of bias current, reducing disturbance of high-impedance sensor networks, while the 2 MHz gain-bandwidth product and 17 V/us slew rate provide headroom for moderately fast excitation and measurement waveforms. The 106 dB CMRR supports rejection of common-mode noise at the bridge output. Designers should still verify the bridge excitation range, sensor output impedance, INA111BU input common-mode limits, and the output swing at the selected gain. Place the instrumentation amplifier close to the sensor connector, keep differential input traces tightly coupled, and provide a clean ground reference to avoid converting common-mode interference into differential error.

⚡

Shunt-Based Current Measurement

The INA111BU is appropriate for measuring the differential voltage generated by a current shunt when the shunt voltage is small relative to its common-mode potential. Its less-than-20-pA input bias current limits error in the measurement path, and the 106 dB CMRR helps separate the shunt differential signal from supply and ground disturbances. The 2 MHz bandwidth allows the amplifier to handle faster current transients than a precision-only instrumentation amplifier, while the 17 V/us slew rate supports larger output excursions. The shunt resistance, amplifier gain, and amplifier supply must be selected together so that output swing remains within the device limits. Kelvin-style routing from the shunt contacts is recommended to reduce voltage drops caused by PCB and connector resistance.

🖥️

Precision Data Acquisition

The INA111BU can serve as the analog front end of a precision data-acquisition channel when the target signal requires both low input bias current and more bandwidth than a conventional precision instrumentation amplifier. Its single-channel FET-input topology is useful ahead of an ADC, while the 2 MHz gain-bandwidth product and 17 V/us slew rate provide useful dynamics for sensor, waveform, and industrial-control signals. The system designer must determine the gain from the maximum input level, then confirm that the resulting bandwidth and settling behavior are adequate for the ADC conversion rate. Use a single ground reference around the analog section, keep the amplifier output path short, and isolate digital return currents from sensitive input nodes. Reference-design components should be selected from the manufacturer application guidance.

🔧

Laboratory Instrumentation

The INA111BU is well suited to laboratory measurement equipment that must amplify low-level differential sensor signals while rejecting common-mode noise generated by bench power supplies and surrounding equipment. The less-than-20-pA bias current is beneficial with high-impedance sources and long filter networks, while the 2 MHz bandwidth supports signal capture beyond slow DC-only amplifier performance. For instrument front ends, the gain-setting network should be placed close to the amplifier, while input and output filtering should be designed around the desired measurement bandwidth. Guard traces and a low-impedance analog ground plane can improve common-mode rejection in high-gain systems. Validate offset, noise, settling, and common-mode behavior on the final board because enclosure grounding and cable routing can materially affect measured performance.

🏭

Process Control Monitoring

The INA111BU can condition low-level differential process signals in industrial monitoring systems where sensor leads share ground potential with substantial common-mode voltage. Its 106 dB CMRR helps reject common-mode disturbance, while the FET-input bias current below 20 pA minimizes loading of sensitive bridges and high-impedance transducers. The 2 MHz bandwidth and 17 V/us slew rate are useful for control loops or monitoring channels with transient content beyond a purely DC response. The amplifier should be located near the field-side connector, with input routing designed as a differential pair and ground arranged to avoid sharing paths with pumps, relays, and switching converters. Verify industrial temperature requirements, transient immunity, surge protection, and fail-safe behavior at the system level before using the component as the sole protection element.

💊

Medical Signal Acquisition

The INA111BU can amplify low-level differential physiological or diagnostic sensor signals when the acquisition system requires low bias current and a modest increase in bandwidth. The less-than-20-pA input bias current reduces errors with high-impedance sensing elements, while the 106 dB CMRR supports rejection of common-mode pickup from cables and surrounding equipment. The 2 MHz bandwidth can accommodate sensor dynamics that are faster than DC-only instrumentation amplifiers, subject to noise and isolation requirements. Medical use requires system-level evaluation of leakage current, patient protection, isolation, electromagnetic immunity, and applicable quality processes; the component itself does not establish compliance for a finished medical device. Use the manufacturer application guidance for input networks, and validate the complete acquisition chain for motion artifacts, noise, saturation, and recovery after stimulus events.

What is the INA111BU?
The INA111BU is a single-channel, high-speed, FET-input instrumentation amplifier from Texas Instruments. According to the manufacturer product page, it combines a 2 MHz gain-bandwidth product with input bias current below 20 pA, while the distributor listing identifies a 16-pin SOIC package. It is intended for low-level differential signal amplification and common-mode rejection.
What are the key specifications of INA111BU?
The key INA111BU specifications are a 2 MHz gain-bandwidth product, 17 V/us slew rate, 106 dB CMRR, less than 20 pA input bias current, and a 6 V to 18 V supply range. The manufacturer information also specifies operation from -40 C to +85 C. The INA111BU is packaged as a single-channel amplifier in a 16-pin SOIC.
Where to download the INA111BU datasheet PDF?
The official INA111BU datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina111.pdf. It is the primary document for the pin description, recommended application circuits, electrical characteristics, and operating limits. The official product page at https://www.ti.com/product/INA111 provides ordering and parameter information alongside the datasheet.
Where can I find the INA111BU pinout?
The INA111BU pinout and pin descriptions are in the pin-configuration section of the Texas Instruments INA111 datasheet. The component uses a 16-pin SOIC, and every connection must be assigned from that manufacturer table. A complete verified pin-by-pin list should be transferred directly from the datasheet before PCB routing or schematic review.
What supply voltage does the INA111BU require?
The INA111BU operates from a 6 V minimum to 18 V maximum supply. This range allows use with conventional positive analog supplies and split supplies referenced to ground. According to the Texas Instruments product information, the device is specified over the full operating range; exact quiescent current and rail-to-rail behavior should be checked in the manufacturer datasheet.
Why use a FET-input instrumentation amplifier?
A FET-input instrumentation amplifier is appropriate when measuring low-level differential signals from high-impedance sources. The INA111BU reduces input bias current to less than 20 pA, which helps minimize errors in source resistance, input filtering, and guarding networks. Its three-op-amp architecture also supports gain adjustment while preserving a straightforward differential measurement front end.
What applications suit the INA111BU?
The INA111BU suits bridge-sensor conditioning, shunt-based current measurement, laboratory instrumentation, process monitoring, and precision analog acquisition. Its 2 MHz bandwidth supports moderately fast measurements, while 106 dB CMRR helps reject common-mode noise. The selected gain and bandwidth must remain compatible with the source impedance and required measurement bandwidth.
INA111BU vs INA114BU - which is better for a high-speed design?
The INA111BU is the better match when the design specifically requires its 2 MHz gain-bandwidth product and 17 V/us slew rate. The INA114BU is described as a precision instrumentation amplifier with a single external resistor and a different gain range. Confirm pin compatibility and bandwidth separately because both appear in 16-pin SOIC packages but their internal priorities differ.
When should I choose INA111BU over INA114BU?
Choose the INA111BU when high-speed differential measurement and low input bias current are more important than precision-focused gain configuration. The INA111BU combines a 2 MHz bandwidth, 17 V/us slew rate, and less than 20 pA input bias current. Choose the INA114BU instead when its precision-amplifier architecture and stated gain-setting range better match the measurement system.
What can replace INA111BU?
The closest identified same-package replacement is the INA111BUE4, which is listed as a 16-SOIC instrumentation amplifier with a 2 MHz bandwidth. Other candidate families, including INA114BU and INA114AUE4, may use the same package dimensions, but package similarity alone does not prove drop-in compatibility. Verify every pin function and electrical limit before substitution.
Is INA111BU the same as INA111BUE4?
The INA111BU and INA111BUE4 are identified as 16-SOIC instrumentation amplifiers with a 2 MHz bandwidth. The available comparison identifies both as INA111 family devices. Their order suffixes can encode packaging or qualification information, so the manufacturer ordering table and datasheet should be checked to confirm the exact temperature, tape-and-reel, and qualification attributes.
What is the best Analog Devices equivalent for INA111BU?
The cross-reference search identifies Analog Devices as a replacement manufacturer for the INA111, but the available material does not name a specific Analog Devices MPN. A defensible drop-in recommendation therefore requires a candidate with verified 16-pin SOIC pin compatibility, acceptable bandwidth, supply range, gain method, and input bias current. Use the Texas Instruments cross-reference search to identify and validate the exact part.
Does INA111BU need input filtering?
The INA111BU's FET inputs reduce bias current below 20 pA, but filtering may still be needed to control high-frequency noise or common-mode transients. Choose resistor and capacitor values from the manufacturer application guidance, then verify noise, settling behavior, and bandwidth experimentally. Do not add capacitance directly to an input unless the resulting pole is accounted for in the signal chain.
How should gain and bandwidth be selected for INA111BU?
Select INA111BU gain from the manufacturer gain-setting guidance while keeping the resulting closed-loop bandwidth adequate for the measurement. A 2 MHz gain-bandwidth product means achievable signal bandwidth decreases as closed-loop gain rises. Also verify output swing, input common-mode range, slew-rate demand, and supply headroom before finalizing the gain configuration.
Where to buy INA111BU online and what is its current lead time?
Use the Request a Quote form on this page to request current INA111BU pricing, stock, lot information, and lead time for the required package and quantities. The manufacturer lists INA111 options in 8-pin plastic DIP and SOL-16 surface-mount packages, while INA111BU denotes the 16-pin SOIC ordering configuration. Commercial terms can change by lot and packaging.
Is INA111BU in stock and what does it cost?
Current INA111BU stock, quantity breaks, and pricing should be obtained through the Request a Quote form on this page. The public distributor result confirms the exact 16-SOIC ordering code but does not provide a qualifying quantity-break price table. This page therefore does not publish a static price or stock claim that could become inaccurate.

נתוני עזר הנדסיים עבור INA111BU — השוואה, הנחיות תכנון ומידע על תאימות.

מדריך בחירה

Choose the INA111BU for low-level differential measurements that benefit from a 2 MHz gain-bandwidth product, 17 V/us slew rate, 106 dB CMRR, and less-than-20-pA input bias current. It is particularly appropriate for bridge sensors, shunts, laboratory equipment, and process-monitoring inputs where source impedance is high or signal dynamics extend beyond a slow precision amplifier. The INA111BUE4 is the closest identified same-family option, but its order suffix should be checked for packaging, temperature, and qualification requirements before substitution. Consider the INA114BU or INA114AUE4 when their precision-oriented architecture and gain range are better priorities, but verify pin functions and bandwidth because a 16-pin SOIC outline alone does not prove drop-in compatibility. For every candidate, confirm supply range, common-mode input range, output swing, gain equation, noise, settling, and operating temperature before releasing a PCB revision.

השוואה עם חלופות

פרמטר מוצר זה INA111BUE4 INA114BU INA114AUE4
Package 16-pin SOIC 16-pin SOIC 16-pin SOIC 16-pin SOIC
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type High-speed FET-input instrumentation amplifier Instrumentation amplifier Precision instrumentation amplifier Precision instrumentation amplifier
Number of Amplifiers 1 circuit 1 amplifier 1 amplifier 1 amplifier
Gain Configuration External gain-setting resistor External gain-setting resistor Single external resistor, gain up to 10000 Single external resistor, gain up to 10000

מבדילים עיקריים

  • High-speed instrumentation-amplifier performance (לעומתINA114BU)
  • Very low FET-input bias current (לעומתINA114AUE4)
  • Direct same-family ordering alternative (לעומתINA111BUE4)

הערות תכנון

Route the two INA111BU inputs as a closely coupled differential pair from the source or shunt, and connect their returns to a quiet analog-ground region. Avoid placing the input pair beneath switching regulators, relays, digital clock lines, or other high-current paths. Keep the gain-setting resistor close to the appropriate device pin, and verify the final placement against the manufacturer application layout.

Do not select gain from the 2 MHz gain-bandwidth figure alone. Increasing closed-loop gain reduces usable bandwidth and may increase output-noise contribution. Check the input common-mode range, output voltage swing, supply headroom, and slew-rate requirement for the worst operating condition. The INA111BU's 17 V/us slew rate is meaningful only if the selected output amplitude and frequency remain within those limits.

For high-impedance sources, minimize leakage through contaminated boards, long exposed traces, and input protection networks. The INA111BU's less-than-20-pA bias current helps, but guarding and clean assembly practices remain necessary. Use short inputs, clean connector materials, and appropriate filtering derived from the source impedance and target signal bandwidth. Confirm that added capacitance does not create an unintended input pole or degrade settling.

מידע על תאימות

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
נטול עופרת
Unknown
נטול הלוגנים
Unknown
מינרלים של סכסוך
Unknown

The accessible product information does not state component-specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable because this is a general-purpose analog amplifier rather than an automotive-qualified device.

הנתונים אומתו בתאריך: 2026-11-03 — נתונים אומתו ונערכו על ידי צוות הנדסת הרכיבים של XAIPART

חיפושים קשורים

INA111BU datasheet INA111BU datasheet pdf INA111BU pinout INA111BU specifications INA111BU 16 pin SOIC INA111BU 2 MHz instrumentation amplifier INA111BU replacement INA111BU equivalent INA111BU cross reference INA111BU vs INA114BU Texas Instruments INA111BU INA111BU price INA111BU stock INA111BU bridge sensor amplifier

רכיבים ומונחים קשורים

Texas Instruments INA111BU INA111BUE4 INA114BU INA114AUE4 instrumentation amplifier operational amplifier analog amplifier semiconductor FET input input bias current common-mode rejection ratio CMRR gain-bandwidth product slew rate 16-pin SOIC SOIC family surface-mount package bridge sensor current shunt data acquisition process control RoHS REACH
בקשת הצעת מחיר מהירה
מלא את כל הפרטים — צוות המכירות שלנו יגיב תוך 24 שעות
מספר חלק יצרן מארז QTY מחיר יעד סה"כ
✓
הצעת המחיר נשלחה!

נשיב לדוא"ל שלך בתוך 24 שעות

1
בקשת הצעת מחיר נשלחה
2
הצעת מחיר התקבלה
3
ההזמנה בוצעה
4
תשלום
5
נשלח
6
נמסר
צפה בפרטי בקשת הצעת המחיר