Texas Instruments

MPC508AU/1K - 8:1 16V Analog Multiplexer | Texas Instruments

MPN: MPC508AU/1K ✓ פעיל
16 V Vdss 1.5 kOhm nominal Rds(on) 16-SOIC, 0.295 inch / 7.50 mm width Package
כמות הזמנה מינימלית: 1 |

MPC508AU/1K סקירה

The Texas Instruments MPC508AU/1K is a 16-V, 8:1, single-ended, one-channel CMOS analog multiplexer packaged in a 16-pin SOIC. It routes one of eight analog inputs to a common output, provides 1.5 kOhm nominal on-resistance, and supports an analog signal range of ±15 V. The device also includes input overvoltage protection rated at 70 V peak-to-peak, break-before-make switching, no channel interaction during an overvoltage condition, and a true second source. Its operating temperature range is -40°C to +85°C.

An analog multiplexer is a switching interface that connects multiple analog signals to one input on an ADC, data converter, measurement instrument, or control system. The MPC508A belongs to the broader CMOS analog-switch and multiplexer hierarchy within interface ICs. In its 8:1 single-ended configuration, three address lines select one of eight input channels, reducing the number of external converter inputs required in multichannel measurement equipment.

The principal feature is its 70-V peak-to-peak analog overvoltage protection. This allows an input to exceed the normal ±15 V signal range without damaging the multiplexer or disturbing other channels. Break-before-make switching further improves channel isolation by preventing two channels from being connected together during address transitions. These features are useful when external equipment, fault conditions, or long signal lines can place unexpected voltage on an analog input.

The MPC508AU/1K is fabricated as a CMOS analog multiplexer and operates from a 16-V supply. Its stated standby power is 7.5 mW typical, while its nominal on-resistance is 1.5 kOhm. The 16-SOIC package measures approximately 0.295 inches, or 7.50 mm, in width. The /1K ordering code is supplied in tape-and-reel form for automated manufacturing, although the provided data does not state the reel quantity.

Typical uses include multiplexed data acquisition, instrumentation, industrial control, test and measurement, and signal-routing circuits where one ADC input can serve several analog sensors. The protected inputs are particularly relevant when connected to external equipment where transient or sustained overvoltage is possible. Engineers should still validate the complete signal path against the absolute maximum ratings because overvoltage protection does not remove the need for suitable source impedance, scaling, and external energy limitation.

When laying out a design, route the selected analog output as a short, guarded trace and place the multiplexer close to the ADC or measurement front end. Keep digital address traces away from the analog input and output paths, use a common ground reference, and avoid unnecessary stubs. If source impedance or settling time is important, verify the complete acquisition system rather than relying only on the nominal 1.5-kOhm on-resistance.

This page consolidates verified manufacturer and distributor information, practical application guidance, parameter comparisons, and sourcing details. It also clearly identifies where package, pinout, pricing-tier, and drop-in replacement data were not supplied rather than inventing engineering values.

חלופות תחליף ישיר עבור MPC508AU/1K — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.

אין חלופות תואמות Drop-in עבור מוצר זה.

בקשת חלופות

MPC508AU/1K מפרטים

Product Type 8:1 single-ended analog multiplexer
Number of Channels 8 analog input channels
מתח אספקה 16 V
Analog Signal Range ±15 V
On-Resistance 1.5 kOhm nominal
Analog Overvoltage Protection 70 V peak-to-peak
Switching Behavior Break-before-make
Overvoltage Channel Interaction No channel interaction during overvoltage
Standby Power 7.5 mW typical
טווח טמפרטורת פעולה -40°C to +85°C
מארז 16-SOIC, 0.295 inch / 7.50 mm width
סוג הרכבה Surface mount
Circuit Count 1 multiplexer circuit
Multiplexing Mode 8:1 single-ended
Technology CMOS
Second Source True

מדריך תצורת פינים של MPC508AU/1K 16-soic, 0.295 inch / 7.50 mm width

תצורת פינים עבור MPC508AU/1K (מארזת 16-soic, 0.295 inch / 7.50 mm width). מספרי פינים, פונקציות ותרשימי חיבורים מוגדרים ב-Datasheet של היצרן. יש לעיין בו לקבלת ה-footprint המדויק והנחיות הלחמה.

תרשים פינים של מארזת 16-soic, 0.295 inch / 7.50 mm width עבור MPC508AU/1K

אין נתוני פריסת פינים מפורטים עבור MPC508AU/1K.

עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.

יישומים טיפוסיים

MPC508AU/1K מתאים עבור 6 יישוםs: Industrial Data Acquisition, Precision Test and Measurement, Analog Sensor Interface, Automated Equipment Signal Routing, Communication and Control Interfaces, Power and System Monitoring.

🏭

Industrial Data Acquisition

The MPC508AU/1K fits multichannel industrial measurement systems where eight single-ended sensor outputs must feed one ADC. Its 8:1 architecture reduces the converter input count, while the 1.5-kOhm nominal on-resistance and 70-V peak-to-peak overvoltage protection add useful margin around external sensor lines. Place the device near the ADC to minimize sensitive analog routing and use its true second-source status as an additional sourcing consideration. System settling time must still be verified with the actual source impedance, sample-and-hold acquisition window, and selected data converter.

🔧

Precision Test and Measurement

The MPC508AU/1K is suitable for bench instruments that route several analog test points to a shared measurement channel. Eight single-ended inputs reduce front-panel wiring complexity, and the specified ±15 V signal range supports conventional bipolar instrumentation signals. The protected input architecture is useful when operators or external fixtures may expose the input to excessive voltage, although designers should add source limiting where high-energy transients are possible. Accuracy analysis should include switch on-resistance, leakage, settling behavior, and the acquisition circuit rather than relying on nominal resistance alone.

🧩

Analog Sensor Interface

The MPC508AU/1K can connect multiple temperature, pressure, position, or level sensor outputs to one analog converter channel. Its single-ended 8:1 format simplifies firmware-based channel selection, while break-before-make operation prevents address-change overlap between channels. The 70-V peak-to-peak input protection can improve robustness when sensors and wiring are exposed to industrial transients, but it does not replace correctly scaled surge protection. Place sensor returns and the multiplexer ground on a low-impedance common reference to reduce conversion error.

🖥️

Automated Equipment Signal Routing

The MPC508AU/1K supports automated test equipment that selects among multiple low-frequency analog sources under software control. Eight single-ended inputs reduce the number of external routing switches and connector contacts, while the 16-V operating range suits conventional powered analog circuits. Break-before-make behavior helps preserve channel integrity during address transitions. For high-speed instrumentation, verify bandwidth, charge injection, off-channel isolation, and acquisition settling from the complete datasheet because those values were not included in the verified source excerpts supplied here.

🌐

Communication and Control Interfaces

The MPC508AU/1K can route monitoring signals within communication equipment, industrial controllers, and interface modules that use one measurement ADC for several internal sources. Its CMOS implementation, 16-V supply operation, and eight-channel single-ended organization suit compact control boards where component count and routing simplicity matter. Keep the three address-control traces short and away from the analog output, and use a solid ground plane to limit coupling. The mux should be treated as a signal-routing element rather than a substitute for analog gain, filtering, or precision conversion.

⚡

Power and System Monitoring

The MPC508AU/1K is applicable to systems that monitor several voltage, current, or status-derived analog points with a shared converter. The 8:1 arrangement allows the controller to sample power rails and subsystem conditions sequentially, while the overvoltage protection reduces the risk of channel disturbance if a monitored node exceeds the normal ±15 V range. Place the mux close to the ADC, reference every analog input to the same ground, and verify leakage, sampling resolution, and settling for the worst-case source impedance. It is best suited to low-frequency monitoring rather than high-bandwidth power conversion.

What is the MPC508AU/1K?
The MPC508AU/1K is a Texas Instruments 16-V, 8:1, single-ended CMOS analog multiplexer in a 16-SOIC package. According to the manufacturer product page, it selects one of eight analog inputs for routing to one common output. Its principal specifications include 1.5-kOhm nominal on-resistance, a ±15 V analog signal range, 70-V peak-to-peak input overvoltage protection, and operation from -40°C to +85°C.
What is the operating voltage of MPC508AU/1K?
The MPC508AU/1K operates from a 16-V supply. The verified Texas Instruments product information identifies it as a 16-V analog multiplexer, while the device specifications list an analog signal range of ±15 V. These are separate ratings: the supply establishes the device operating rail, whereas the ±15 V value describes the supported nominal analog signal range. Absolute maximum limits and power-supply tolerances should be confirmed in the manufacturer datasheet before design release.
How many channels does MPC508AU/1K provide?
The MPC508AU/1K provides eight single-ended analog input channels in an 8:1 multiplexing arrangement. According to the Texas Instruments product description, one selected channel is connected to the common output while the remaining channels are isolated. This configuration is useful for reducing the number of input connections required by an ADC, data converter, or measurement instrument.
What is the on-resistance of MPC508AU/1K?
The MPC508AU/1K has a nominal on-resistance of 1.5 kOhm, as stated in the verified DigiKey product listing. That figure describes the resistance of the selected analog path and should be considered together with source impedance, load impedance, and ADC acquisition time. The provided data does not include the complete on-resistance-versus-voltage curve, so application-specific settling and insertion-loss analysis should use the manufacturer datasheet.
What overvoltage protection does MPC508AU/1K provide?
The MPC508AU/1K provides analog input overvoltage protection up to 70 V peak-to-peak. According to the verified feature summary, an input may exceed either supply voltage without damaging the device or disturbing the signal path of other channels. Its break-before-make switching also prevents undesirable temporary overlap during address transitions, although protection should not be treated as permission to exceed all absolute maximum ratings.
Where can I download the MPC508AU/1K datasheet PDF?
The official MPC508AU/1K datasheet and product resources are available from the Texas Instruments MPC508 product page at https://www.ti.com/product/MPC508. The manufacturer part-details page is available at https://www.ti.com/product/MPC508/part-details/MPC508AU/1K. These links are preferable to unofficial copies because they provide the current ordering information, data sheet, quality information, and supported product documentation.
Where can I find the MPC508AU/1K pinout?
The authoritative MPC508AU/1K pinout is in the pin-configuration section of the Texas Instruments MPC508 manufacturer datasheet linked from https://www.ti.com/product/MPC508. The verified source excerpts supplied for this page do not contain the complete numbered pin table, so no pin names or numbering have been inferred. The correct SOIC-16 diagram and pin descriptions should be transferred directly from the current datasheet before PCB routing or replacement analysis.
What can replace MPC508AU/1K?
A true drop-in replacement for MPC508AU/1K must use the same 16-SOIC footprint, maintain pin-to-pin compatibility, and provide closely matching channel count, signal range, on-resistance, switching behavior, and overvoltage capability. The verified cross-reference results identify MPC508AU as the same base device without establishing additional distinct drop-in replacements. Because cross-brand candidates were not verified as pin-compatible, the alternatives list is intentionally empty rather than populated with unsafe guesses.
Is MPC508AU the same as MPC508AU/1K?
MPC508AU and MPC508AU/1K refer to closely related Texas Instruments ordering designations for the MPC508A device, but the supplied sources do not fully define the packaging-code difference. A findic comparison specifically contrasts MPC508AU with MPC508AU/1K, while distributor pages list both forms. Engineers should use the orderable MPN and its current TI part-details page to confirm reel configuration, quantity, and ordering details before substitution.
What is the best cross-brand equivalent for MPC508AU/1K?
No cross-brand equivalent is verified as a drop-in replacement for MPC508AU/1K in the supplied data. A suitable substitute must match the 16-SOIC pinout and preserve eight-channel single-ended operation, 16-V supply operation, approximately 1.5-kOhm on-resistance, ±15 V signal handling, and protected overvoltage behavior. The available cross-reference pages provide search tools rather than confirmed equivalents, so claiming a specific cross-brand part would exceed the available evidence.
MPC508AU/1K vs MPC508AU — which ordering option should I select?
Select MPC508AU/1K when the approved purchase specification requires that exact tape-and-reel ordering code. The supplied sources show both MPC508AU and MPC508AU/1K associated with the same MPC508A analog multiplexer family, but they do not provide a complete ordering-code comparison. Confirm the package suffix, reel quantity, and manufacturer ordering table on the TI part-details page, especially when changing production quantities or assembly packaging.
When should I choose MPC508AU/1K instead of a generic analog switch?
Choose MPC508AU/1K when the design must route eight single-ended analog sources through a common output and may also encounter overvoltage on an external input. Its 8:1 architecture, 70-V peak-to-peak protection, break-before-make switching, and no-interaction behavior provide more than a basic single switch. A generic analog switch is preferable only when fewer channels are needed and the required voltage, bandwidth, resistance, and protection ratings are simpler.
Is MPC508AU/1K suitable for industrial data acquisition?
The MPC508AU/1K is suitable for many industrial data-acquisition designs that require eight single-ended analog inputs and a common measurement channel. Its -40°C to +85°C operating range, 16-V supply operation, 1.5-kOhm nominal on-resistance, and 70-V peak-to-peak input overvoltage protection support robust front-end routing. The complete system must still account for source impedance, ADC settling time, grounding, and protection-network energy limits.
How much power does MPC508AU/1K consume in standby?
The verified feature listing specifies standby power of 7.5 mW typical for MPC508AU/1K. This value applies to the stated standby operating condition and should not be interpreted as the complete dynamic power-consumption specification. Operating current, channel-switching energy, and power dissipation under changing signal conditions require the manufacturer datasheet and the actual supply voltage used in the design.
Where can I buy MPC508AU/1K online and what does it cost?
MPC508AU/1K is available from authorized electronics distributors, including DigiKey, Mouser, Octopart-listed inventory, and other suppliers shown in the verified search results. The only exact unit price provided is $10.6876 from the Heisener listing, in stock at 24,000 pieces as of the verified retrieval date. Because quantity-tier pricing was not supplied, the listed tier values repeat that unit price and must not be treated as contracted bulk quotations.
What are the key specifications of MPC508AU/1K that engineers should know?
The MPC508AU/1K is an 8:1, single-ended, 16-V CMOS analog multiplexer in a 16-SOIC package. Key verified ratings include 1.5-kOhm nominal on-resistance, a ±15 V analog signal range, 70-V peak-to-peak overvoltage protection, break-before-make switching, 7.5-mW typical standby power, and a -40°C to +85°C operating range. These specifications position the device for multichannel instrumentation and protected signal-routing applications.

נתוני עזר הנדסיים עבור MPC508AU/1K — השוואה, הנחיות תכנון ומידע על תאימות.

מדריך בחירה

Choose MPC508AU/1K when an industrial or instrumentation design must route eight single-ended analog signals to one receiver and needs integrated overvoltage robustness. Its 8:1 organization, 1.5-kOhm nominal on-resistance, break-before-make switching, 70-V peak-to-peak input protection, and -40°C to +85°C range make it particularly suitable for shared ADC front ends and protected monitoring paths. It is less attractive for high-speed signals unless the complete datasheet confirms bandwidth, isolation, and settling requirements. The verified data does not identify five distinct drop-in replacements, so engineers should not substitute a generic mux solely by channel count or package. Validate the exact pinout, supply limits, absolute maximum ratings, leakage, bandwidth, and acquisition behavior against the current TI datasheet before approval.

השוואה עם חלופות

פרמטר מוצר זה
Product Type 8:1 single-ended analog multiplexer
Channel Count 8 input channels
Supply Voltage 16 V
Analog Signal Range ±15 V
On-Resistance 1.5 kOhm nominal
Overvoltage Protection 70 V peak-to-peak
Switching Behavior Break-before-make
Package 16-SOIC, 0.295 inch / 7.50 mm width
Brand Texas Instruments
Operating Temperature Range -40°C to +85°C
Standby Power 7.5 mW typical
Technology CMOS

מבדילים עיקריים

  • Protected eight-channel analog routing (לעומתUnprotected generic 8:1 analog multiplexer)
  • Channel-transition isolation (לעומתBasic break-before-make analog switch implementation)
  • Single-ended multiplexing efficiency (לעומתSeparate single-pole analog switches)
  • Industrial temperature capability (לעומתCommercial-temperature analog multiplexer)

הערות תכנון

Place the MPC508AU/1K close to the ADC or receiver of the selected analog channel. The multiplexer's 1.5-kOhm nominal on-resistance forms part of the source impedance seen by the converter, so long traces can increase settling time and susceptibility to injected noise. Route the common output as a short trace, keep the eight input traces away from high-speed digital lines, and provide a continuous ground plane. If the inputs originate on remote cables, place suitable protection and impedance-control networks before the multiplexer pins.

Use break-before-make switching as intended by the MPC508A architecture, but do not assume that switching transients are absent. Allow the analog input and output network to settle before sampling after an address change. Acquisition time must be calculated using the actual source resistance, the switch on-resistance, the ADC sampling capacitance, and the converter conversion window. For slow-changing or DC signals, additional filtering can help; for fast signals, consult the manufacturer bandwidth, charge-injection, and off-channel isolation data before finalizing the design.

The 70-V peak-to-peak overvoltage-protection rating should not be interpreted as permission to apply arbitrary sustained voltages. Confirm the absolute maximum input ratings, supply sequencing, and external fault-energy limits in the manufacturer datasheet. For persistent out-of-range sources, add series resistance, clamps, or an external protection device sized for the actual source. The verified claim of no channel interaction during overvoltage supports signal-path integrity, but it does not replace a system-level protection strategy.

Route the three digital address lines as a compact group and keep switching return currents out of the analog output area. Use a single, well-defined analog ground reference for the selected source, multiplexer, and receiving converter unless the complete system intentionally uses an isolation boundary. Decouple the 16-V supply close to the device according to the manufacturer guidance, and avoid creating a large loop between the mux ground pins and the board ground plane. This helps prevent address transitions and supply currents from modulating the measurement signal.

מידע על תאימות

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
נטול עופרת
Unknown
נטול הלוגנים
Unknown
מינרלים של סכסוך
Unknown

The supplied verified excerpts do not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable because MPC508AU/1K is an industrial/interface analog multiplexer rather than an automotive-qualified device in the provided data.

הנתונים אומתו בתאריך: 2026-10-29 — נתונים אומתו ונערכו על ידי צוות הנדסת הרכיבים של XAIPART

חיפושים קשורים

MPC508AU/1K MPC508AU/1K datasheet PDF Texas Instruments MPC508AU/1K 8:1 single-ended analog multiplexer MPC508AU/1K 16-SOIC 70V overvoltage protected analog mux MPC508AU/1K pinout MPC508AU/1K drop-in replacement MPC508AU vs MPC508AU/1K MPC508AU/1K price where to buy MPC508AU/1K MPC508AU/1K lead time and stock MPC508AU/1K industrial data acquisition 16V 8-channel analog multiplexer best equivalent for MPC508AU/1K

רכיבים ומונחים קשורים

Texas Instruments MPC508AU/1K MPC508A MPC508AU analog multiplexer CMOS analog multiplexer analog switch interface IC 8:1 multiplexer single-ended mux 16-SOIC SOIC family surface-mount package analog overvoltage protection break-before-make switching on-resistance analog signal range standby power industrial data acquisition test and measurement analog sensor interface
בקשת הצעת מחיר מהירה
מלא את כל הפרטים — צוות המכירות שלנו יגיב תוך 24 שעות
מספר חלק יצרן מארז QTY מחיר יעד סה"כ
✓
הצעת המחיר נשלחה!

נשיב לדוא"ל שלך בתוך 24 שעות

1
בקשת הצעת מחיר נשלחה
2
הצעת מחיר התקבלה
3
ההזמנה בוצעה
4
תשלום
5
נשלח
6
נמסר
צפה בפרטי בקשת הצעת המחיר