TJA1041AT - 1 Mbit/s High-Speed CAN Transceiver | NXP
MPN: TJA1041AT ✗ סוף ייצורTJA1041AT סקירה
A CAN transceiver is the physical-layer interface between a CAN protocol controller and a wired CAN bus. Within the hierarchy of CAN interface ICs, CAN transceivers sit between microcontrollers or dedicated CAN controllers and the differential bus. They combine a transmitter, receiver, bus-driver protection, and logic-level interfaces into one component. This integration allows a protocol controller to exchange messages with other CAN nodes while the transceiver handles the physical signaling characteristics of the bus.
The TJA1041AT supports CAN data rates up to 1 Mbit/s and is compatible with the ISO 11898 standard. Its differential transmitter and receiver support communication over a balanced CAN bus, while its digital transmit and receive pins connect to a CAN controller. NXP identifies the TJA1041AT as an end-of-life product, so long-lived automotive, industrial, and transportation programs should confirm lifecycle strategy and replacement planning with NXP before committing new production volumes.
The SOIC-14 package provides separate connections for logic supply, transceiver supply, transmit data, receive data, standby control, CANH, and CANL. Its surface-mount construction supports automated PCB assembly, while the comparatively large lead pitch facilitates inspection and rework compared with fine-pitch packages. Precise pin names, truth-table behavior, electrical limits, and unused-pin connections should be assigned directly from the pin-description table and application information in the manufacturer datasheet.
Typical uses include automotive body and powertrain networking, industrial automation equipment, transportation controllers, embedded CAN gateways, and diagnostic interfaces. The 1 Mbit/s capability suits conventional high-speed CAN networks used throughout vehicle and factory automation systems. A suitable host controller must support the device's logic levels, supply arrangement, standby behavior, and CAN protocol requirements.
Designers should preserve the recommended transceiver and controller grounding arrangement, route CANH and CANL as a differential pair, and place protection or termination components where the bus topology requires them. Bus termination, common-mode range, loop delay, radiated emissions, and fault tolerance must be evaluated at system level rather than inferred solely from the nominal data rate.
This product page combines the manufacturer lifecycle status, datasheet characteristics, application guidance, and cross-reference assessment to support engineering selection. It also distinguishes a genuine PCB-footprint replacement from merely similar CAN devices, avoiding the unsafe assumption that equal functionality automatically means pin-to-pin compatibility.
חלופות תחליף ישיר עבור TJA1041AT — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
TJA1041AT/CM,118
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
TJA1041AT מפרטים
| Product Type | High-speed CAN transceiver |
| Maximum CAN Data Rate | 1 Mbit/s |
| Supply Voltage Range | 4.75 V to 5.25 V |
| Transmitter Configuration | Differential |
| Receiver Configuration | Differential |
| CAN Standard Compatibility | ISO 11898 |
| Primary Application | Automotive high-speed CAN |
| מארז | 14-pin SOIC |
| סוג הרכבה | Surface mount |
| Standby and Sleep Modes | Supported |
| סטטוס RoHS | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | unknown |
| סטטוס מחזור חיים | End of life |
מדריך תצורת פינים של TJA1041AT 14-pin soic
תצורת פינים עבור TJA1041AT (מארזת 14-pin soic). מספרי פינים, פונקציות ותרשימי חיבורים מוגדרים ב-Datasheet של היצרן. יש לעיין בו לקבלת ה-footprint המדויק והנחיות הלחמה.
אין נתוני פריסת פינים מפורטים עבור TJA1041AT.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
TJA1041AT מתאים עבור 6 יישוםs: Automotive Body Control Network, Vehicle Powertrain Communication, Industrial Automation Controller, Transportation Equipment Interface, Embedded CAN Gateway, Diagnostic and Test Interface.
Automotive Body Control Network
The TJA1041AT fits conventional automotive body-control CAN networks that operate up to 1 Mbit/s. Its differential transmitter and receiver provide the physical interface between a vehicle CAN controller and the shared CANH and CANL bus, while its 4.75 V to 5.25 V supply range supports a conventional 5 V transceiver rail. The 14-pin SOIC package is straightforward for automated assembly and rework. In a body module, the host controller generates and interprets CAN frames while the transceiver converts those frames into balanced bus signals. Final qualification should cover temperature, EMC, fault recovery, standby behavior, and the exact electrical limits in the NXP datasheet.
מומלץ
Vehicle Powertrain Communication
The TJA1041AT is applicable to conventional high-speed CAN links used between vehicle powertrain control modules, provided its electrical, environmental, and lifecycle requirements satisfy the vehicle program. A CAN controller handles arbitration and frame generation, while the TJA1041AT supplies differential signaling to CANH and CANL at rates up to 1 Mbit/s. Its ISO 11898 compatibility aligns it with classic high-speed CAN networks. Designers should verify common-mode voltage, bus fault behavior, propagation-delay limits, thermal conditions, and qualification requirements against the manufacturer datasheet. Because the device is end of life, new powertrain platforms should establish an approved lifecycle path before design freeze.
מומלץ
Industrial Automation Controller
The TJA1041AT can interface an industrial automation controller with a conventional CAN bus operating up to 1 Mbit/s. In a PLC, robot controller, or distributed control module, the host processor communicates through a CAN protocol controller, and the TJA1041AT provides the differential physical layer toward CANH and CANL. Its 14-pin SOIC package supports automated PCB assembly, and standby or sleep operation can help systems manage inactive bus states. The bus design still requires correct termination, controlled routing, grounding, and protection. Industrial users should confirm temperature, EMC, common-mode range, and long-term supply requirements, particularly because NXP labels TJA1041AT as end of life.
מומלץ
Transportation Equipment Interface
The TJA1041AT supports high-speed CAN communication in transportation equipment requiring a conventional differential CAN physical layer. A rail, vehicle, or roadside controller can connect to its CAN protocol controller while the transceiver handles communication with external nodes at rates up to 1 Mbit/s. The 4.75 V to 5.25 V operating range and 14-pin SOIC package are useful for established 5 V controller boards. Integration requires attention to isolated and non-isolated ground strategies, cable surge exposure, termination placement, and diagnostic behavior. The system designer should validate the transceiver against all environmental and protection requirements and consult NXP regarding lifecycle continuity before using the part in a newly launched transportation platform.
מומלץ
Embedded CAN Gateway
The TJA1041AT is suitable for an embedded gateway that translates or bridges conventional CAN traffic at rates up to 1 Mbit/s. The gateway's CAN controller operates at the protocol and frame level, while the TJA1041AT provides the differential bus driver and receiver required by the physical network. Its SOIC-14 package is compatible with conventional PCB assembly processes and remains practical for hand rework. Designers should budget decoupling according to the datasheet, preserve the recommended pin and ground connections, and route CANH and CANL as a balanced pair away from high-speed digital signals. Lifecycle planning is important for gateways expected to remain in production, because NXP marks the target product as end of life.
מומלץ
Diagnostic and Test Interface
The TJA1041AT can provide the physical-layer endpoint for diagnostic equipment or a test interface connected to a high-speed CAN network. The test controller issues and receives CAN frames, and the transceiver converts the logic-side signals into differential CAN bus communication at up to 1 Mbit/s. Differential signaling supports reliable communication over an installed wiring harness, while the 14-pin SOIC package simplifies board assembly. Laboratory and production-test designs should include controlled bus termination, protection appropriate to the harness, and measures to prevent unintended bus activation. The end-of-life designation should prompt an assessment of whether an established test platform can preserve the original footprint while a currently supported part is selected for new equipment.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור TJA1041AT — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה |
|---|---|
| Brand | NXP Semiconductors |
| Package | 14-pin SOIC |
| Product Type | High-speed CAN transceiver |
| Maximum Data Rate | 1 Mbit/s |
| Supply Voltage Range | 4.75 V to 5.25 V |
| Transmit Interface | Differential |
| Receive Interface | Differential |
| CAN Compatibility | ISO 11898 |
| Primary Application | Automotive high-speed CAN |
| Low-Power Modes | Standby and sleep |
| Lifecycle Status | End of life |
הערות תכנון
Route CANH and CANL as a tightly coupled differential pair with continuous reference to the same ground plane, and keep the pair away from switching nodes, clocks, and high-current paths. Place the transceiver close to the bus connector or protection components so the unprotected portion of the network remains short. Use the NXP application diagram to preserve the recommended grounding and connection topology.
Decouple the transceiver supply pins using the capacitance and placement specified in the manufacturer application information. Separate or treat the logic and transceiver supply pins according to the datasheet, and verify that controller-side voltage levels remain compatible with the device. Estimated thermal calculations are not appropriate without the exact supply, load, and board conditions, so use worst-case operating and fault-current limits from the datasheet.
Do not treat functionally similar CAN transceivers as drop-in replacements. A valid substitution must match the 14-pin SOIC footprint, power architecture, logic levels, standby and sleep behavior, bus timing, common-mode range, protection characteristics, and thermal limits. Also avoid selecting a replacement solely from its maximum data rate because propagation delay and fault behavior can affect overall network operation.
Confirm whether the CAN bus requires a 120-ohm termination at each physical endpoint and whether the implementation permits split termination or other network-specific termination schemes. Incorrect termination can degrade signal quality, while unnecessary termination increases bus load. Evaluate the complete harness and topology under worst-case node count rather than adding termination solely based on cable length.
מידע על תאימות
The manufacturer datasheet identifies compatibility with ISO 11898 and an automotive high-speed CAN application. RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations were not confirmed for the exact TJA1041AT orderable variant.