Infineon

TLE7250GVIOXUMA2 - 1Mbps CAN Transceiver, 3.3/5V VIO | Infineon

MPN: TLE7250GVIOXUMA2 ✓ פעיל
4.75 V to 5.25 V Vdss PG-DSO-8-16 / 8-SOIC (0.154 in, 3.90 mm width) Package
כמות הזמנה מינימלית: 1 |

TLE7250GVIOXUMA2 סקירה

The Infineon TLE7250GVIOXUMA2 is a 1 Mbps high-speed CAN transceiver with 3.3 V or 5 V logic adaptation through its VIO pin, packaged in an 8-pin PG-DSO-8-16 (SOIC-8) surface-mount package. It provides a 1 transmitter / 1 receiver half-duplex CAN interface that is ISO 11898-2 compliant, AEC-Q100 qualified for automotive use, and also used in industrial CAN networks.

A CAN transceiver (also called a CAN physical-layer interface) is the component that sits between a microcontroller's CAN protocol controller and the differential CANH/CANL bus wiring. It converts the digital TXD signal into a dominant/ recessive differential bus voltage, and converts the received bus levels into a clean RXD logic signal, while protecting the host controller from bus faults and external interference.

Key features of this device include a 1 Mbps maximum data rate for classic CAN, separate VIO supply pin for 3.3 V or 5 V microcontroller logic levels, 100 mV receiver hysteresis for noise immunity, half-duplex operation, a normal/standby operating mode for low-power parks, and MSL 2A moisture-sensitivity classification. The transceiver is specified for low bus emissions and high electromagnetic immunity, both of which are essential in automotive environments.

Internally the device combines a CAN bus driver stage, a comparator-based receiver with defined hysteresis, internal biasing, and bus-fault and ESD protection on CANH and CANL. The VIO domain decoupling the digital interface from the 5 V transceiver domain lets a 3.3 V MCU talk directly to the bus without level shifters, while the separate transceiver supply keeps bus-side biasing stable.

Typical applications include automotive body control units, electric-vehicle and powertrain CAN gateways, industrial PLC and robot controller CAN networks, elevator and building automation controllers, and sensor-hub CAN nodes in 3.3 V microcontroller systems.

When designing around this part, place the VIO decoupling capacitor directly at the VIO pin and treat CANH and CANL as a tightly coupled differential pair, keeping stub lengths short and the loop area minimal. Use the standby input to force a defined low-power state during wake-up sequences.

This page consolidates the device specification, drop-in alternatives within the Infineon CAN portfolio, comparison parameters, and practical design guidance so that designers can qualify the transceiver quickly instead of parsing multiple catalogue entries.

חלופות תחליף ישיר עבור TLE7250GVIOXUMA2 — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.

TLE7250GVIOXUMA1

✅ Drop-In ⚠️ מפרטים לא מאומתים
📦 PG-DSO-8-16 (8-SOIC)
Same die and SOIC-8 footprint; differs only in ordering/packing suffix, so 1 Mbps rate, 1/1 half-duplex, 4.75-5.25 V supply and 3.3/5 V VIO are unchanged (0% parameter difference)

📋 חלופה להתייחסות (לא בקטלוג)

TLE7250GVIO

✅ Drop-In
📦 PG-DSO-8-16 (8-SOIC)
Manufacturer family name of the identical device; identical 1 Mbps rate, 1/1 half-duplex configuration, 3.3 V / 5 V VIO logic adaptation and ISO 11898-2 compliance (0% parameter difference)

📋 חלופה להתייחסות (לא בקטלוג)

TLE7250GVIOXUMA2

✅ Drop-In
Infineon
📦 PG-DSO-8-16 (8-SOIC)
CAN Transceiver (Physical Layer Interface) · 1 Mbps · 1 / 1 · Half · CANbus (ISO 11898-2) · 4.75 V to 5.25 V · 3.3 V or 5 V · 100 mV

צור קשר לקבלת מחיר

הצג גיליון נתונים ←

TLE7250GVIOXUMA2 מפרטים

Product Type CAN Transceiver (Physical Layer Interface)
קצב נתונים 1 Mbps
Number of Drivers/Receivers 1 / 1
Duplex Half
Protocol CANbus (ISO 11898-2)
Transceiver Supply Voltage 4.75 V to 5.25 V
Logic (VIO) Supply 3.3 V or 5 V
Receiver Hysteresis 100 mV
Supply Pin VCC
Output Pin VIO (3.3 V / 5 V level adaptation)
מארז PG-DSO-8-16 / 8-SOIC (0.154 in, 3.90 mm width)
סוג הרכבה Surface Mount
Moisture Sensitivity Level MSL 2A (4 weeks)
HTS US Code 8542.39.0001
סטטוס RoHS RoHS3 compliant
Automotive Qualification AEC-Q100 qualified
Operating Modes Normal / Standby
Bus Emissions / Immunity Low emissions, high immunity
Ordering Code Suffix XUMA2 (tape and reel)

מדריך תצורת פינים של TLE7250GVIOXUMA2 pg-dso-8-16 / 8-soic (0.154 in, 3.90 mm width)

תצורת פינים עבור TLE7250GVIOXUMA2 (מארזת pg-dso-8-16 / 8-soic (0.154 in, 3.90 mm width)). מספרי פינים, פונקציות ותרשימי חיבורים מוגדרים ב-Datasheet של היצרן. יש לעיין בו לקבלת ה-footprint המדויק והנחיות הלחמה.

תרשים פינים של מארזת pg-dso-8-16 / 8-soic (0.154 in, 3.90 mm width) עבור TLE7250GVIOXUMA2

אין נתוני פריסת פינים מפורטים עבור TLE7250GVIOXUMA2.

עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.

יישומים טיפוסיים

TLE7250GVIOXUMA2 מתאים עבור 6 יישוםs: Automotive Body Control Module CAN Node, Electric Vehicle Powertrain CAN Gateway, Industrial PLC and Robotics CAN Network, Building Automation and Elevator Control, 3.3 V Microcontroller Sensor Hub Node, CAN-to-Serial Gateway and Test Equipment.

🚗

Automotive Body Control Module CAN Node

The TLE7250GVIOXUMA2 suits body control modules that sit on a 500 kbit/s to 1 Mbit/s vehicle CAN backbone. Its 1 Mbps ISO 11898-2 compliant data rate, low bus emissions and high electromagnetic immunity let the module coexist with cranking, alternator and body-actuator switching noise on the same harness. The 3.3 V or 5 V VIO pin means a modern 3.3 V automotive MCU drives TXD and reads RXD directly, while the transceiver domain still runs from a clean 5 V rail. In a standby-capable design the controller can park the bus during key-off and wake it in a defined state before other nodes start transmitting.

⚡

Electric Vehicle Powertrain CAN Gateway

Battery management, inverter and vehicle-controller subsystems often share a high-speed CAN backbone, and the TLE7250GVIOXUMA2 gives a compact, protected physical-layer interface for each of them. The 1/1 half-duplex topology suits the classic CAN segment used for powertrain coordination rather than CAN FD diagnostics links. The device's high immunity lets it operate on harnesses routed next to traction motors and contactors, while low emissions prevent the transceiver from disturbing neighbouring nodes. The 8-pin SOIC-8 footprint keeps the interface small enough for a densely packed inverter control board.

🏭

Industrial PLC and Robotics CAN Network

Factory automation cells frequently use CAN as the backbone between PLCs, robot controllers and sensor nodes, and the TLE7250GVIOXUMA2 covers that physical layer in a 1 Mbps segment. Because the transceiver accepts 3.3 V VIO, it can pair directly with 3.3 V industrial controllers and wireless-capable IO modules without level translators. The 100 mV receiver hysteresis rejects induced noise from nearby variable-frequency drives and contactors, and the normal/standby mode allows a robot cell to drop the bus to a low-power state during safe-stop cycles. Use the standby control input as part of the cell's safety chain.

🏢

Building Automation and Elevator Control

Lift and building-automation controllers talk to door units, call panels and ventilation equipment over CAN segments, and the TLE7250GVIOXUMA2 provides a rugged, compact interface for those nodes. The 1 Mbps rate comfortably covers short in-cabinet CAN networks, while the 5 V transceiver supply matches the regulated rails already present in control cabinets. Standby operation lets the controller keep the bus quiet during maintenance mode so other nodes see a predictable bus state, and the small SOIC-8 outline leaves room for the connector and protection circuitry on a crowded elevator car board.

🧩

3.3 V Microcontroller Sensor Hub Node

Compact sensor hubs built around modern 3.3 V MCUs often lack a 5 V logic-compatible CAN interface, and the TLE7250GVIOXUMA2 solves this through its dedicated VIO pin set to 3.3 V. The bus side still runs from a 4.75 V to 5.25 V supply, so the transceiver can be powered from a local 5 V rail while the digital side matches the MCU. The 100 mV receiver hysteresis preserves data integrity on long sensor cables, and the half-duplex 1/1 arrangement is exactly what a single host CAN port requires. This makes it a natural fit for environmental, vibration and energy-monitoring nodes.

🖥️

CAN-to-Serial Gateway and Test Equipment

Protocol analysers, service tools and gateways that bridge a legacy CAN bus to a serial console are built on a single-transceiver CAN port, and the TLE7250GVIOXUMA2 fits that slot. The device protects the host controller against bus faults and external interference, so a bench instrument connected to a live vehicle or machine bus is less likely to be damaged by transients. The standby input is useful in a test fixture that must keep the bus in a defined recessive state between measurement runs, and the small SOIC-8 footprint leaves room for USB or Ethernet interface electronics beside it.

What is the TLE7250GVIOXUMA2?
The TLE7250GVIOXUMA2 is an Infineon high-speed CAN transceiver for ISO 11898-2 networks with a 1 Mbps maximum data rate. It provides one transmitter and one receiver in half-duplex configuration, accepts a 4.75 V to 5.25 V transceiver supply, and adds a separate VIO pin that supports 3.3 V or 5 V microcontroller logic levels. It is supplied in the PG-DSO-8-16 (8-SOIC) surface-mount package.
What does the VIO pin on the TLE7250GVIO do?
The VIO pin sets the logic level of the digital interface to the CAN controller. According to the Infineon TLE7250GVIO product documentation, the transceiver can be operated with either 3.3 V or 5 V on VIO while the transceiver domain itself stays at 5 V. This removes the need for external level shifters when the host MCU runs from a 3.3 V rail.
Is the TLE7250GVIOXUMA2 suitable for automotive CAN networks?
Yes. The part is described as an automotive CAN transceiver with AEC-Q100 qualification and is listed under CAN transceivers with low bus emissions and high immunity. That combination matters in vehicle environments where the CAN bus cable run is long and adjacent to high-current switching loads. The 1 Mbps data rate matches classic CAN rather than CAN FD.
What is the difference between the TLE7250GVIOXUMA1 and TLE7250GVIOXUMA2?
Both are Infineon TLE7250GVIO high-speed CAN transceivers in the same PG-DSO-8-16 (SOIC-8) package with the same 1 Mbps rate, 1/1 half-duplex configuration and 3.3 V / 5 V VIO logic adaptation. The trailing ordering code identifies the delivery and packing form of the same device family, so they are electrically interchangeable for PCB population as long as the packing format matches your assembly process.
Where can I download the TLE7250GVIOXUMA2 datasheet?
The manufacturer datasheet PDF is available from Infineon at the TLE7250GVIO product page, and datasheet mirrors for the same ordering code are hosted on Octopart and DigiKey. The document defines the pin description, the typical CAN bus application circuit, the electrical characteristics for the 4.75 V to 5.25 V supply and the 3.3 V / 5 V VIO domain, and the absolute maximum ratings.
Where can I find the TLE7250GVIOXUMA2 pinout?
The pin description table for the PG-DSO-8-16 package is in the Infineon TLE7250GVIO datasheet, and the same ordering code appears with pinout diagrams and ECAD data on the DigiKey, Mouser and LCSC product pages. Use that table when assigning PCB tracks for VCC, VIO, GND, TXD, RXD, standby control and the CANH/CANL bus nodes.
What is the receiver hysteresis of the TLE7250GVIOXUMA2?
The receiver hysteresis is specified at 100 mV, as listed in the catalogue attributes for this ordering code. Hysteresis of this magnitude guarantees a defined switching point around the recessive bus level and rejects noise that would otherwise chatter the RXD output. Combined with the low-emission driver stage, it is a key reason the device performs well on noisy automotive and industrial wiring.
How does the TLE7250GVIOXUMA2 compare with a 5 V-only CAN transceiver?
The TLE7250GVIOXUMA2 adds a separate VIO domain, so the digital side can run at 3.3 V while the bus side runs from a 5 V supply. A transceiver with a single fixed 5 V logic domain forces a 3.3 V MCU to use level shifters on TXD and RXD, which adds cost, area and propagation delay. In every other respect the two behave the same on the bus.
What is the standby mode on the TLE7250GVIO and when should it be used?
The device is described as a normal/standby CAN transceiver, meaning a control input can force a low-power state in which the bus driver is de-activated while the supply current drops. Use standby during vehicle key-off or system park so the transceiver does not hold the bus in an active state, then release it before the controller begins transmission.
What applications suit the TLE7250GVIOXUMA2?
The part targets automotive CAN networks and industrial CAN interfaces, as stated by Infineon. Typical uses include body control modules, powertrain and electric-vehicle CAN gateways, PLC and robot controller nodes, building and elevator automation controllers, and 3.3 V microcontroller sensor nodes. The 1 Mbps rate matches classic CAN nodes that do not require CAN FD payload bandwidth.
What are the key specifications of the TLE7250GVIOXUMA2 that engineers should know?
The TLE7250GVIOXUMA2 is a 1 Mbps, 1-transmitter / 1-receiver, half-duplex CAN transceiver in PG-DSO-8-16 (SOIC-8), with a 4.75 V to 5.25 V transceiver supply, 3.3 V or 5 V VIO logic adaptation, 100 mV receiver hysteresis, MSL 2A moisture sensitivity, RoHS3 compliance and AEC-Q100 automotive qualification. It is ISO 11898-2 compliant with low emissions and high immunity.
What is the best drop-in replacement for the TLE7250GVIOXUMA2?
The closest drop-in replacements are other members of the Infineon TLE7250GVIO family, such as the TLE7250GVIOXUMA1 in the identical PG-DSO-8-16 footprint, since they share the same 1 Mbps rate, 1/1 half-duplex configuration, 4.75 V to 5.25 V supply and 3.3 V / 5 V VIO logic adaptation. Verify the ordering code packing format matches your assembly process before substituting.
Is the TLE7250GVIOXUMA2 the same as the TLE7250GVIO?
Yes. TLE7250GVIO is the Infineon product family name, while TLE7250GVIOXUMA2 is the orderable code that specifies the 8-pin SOIC-8 package variant with the XUMA2 packing suffix. The electrical function, pin arrangement, 1 Mbps data rate and 3.3 V / 5 V VIO capability are those of the TLE7250GVIO family.
How do I decouple the TLE7250GVIOXUMA2 on a PCB?
Place the VCC and VIO decoupling capacitors directly at their respective pins, with the shortest possible ground return to the device ground pad, and keep the CANH/CANL traces as a close-coupled differential pair with no stubs. Because the transceiver switches a differential bus, minimise the loop area of the bus traces and keep the transceiver close to the bus connector to reduce radiated emissions.
What is the lead time and availability of the TLE7250GVIOXUMA2?
Stock and lead time change continuously by region and volume, so the fastest confirmation is the Request a Quote form on this page. The manufacturer lists the TLE7250GVIO family as an active high-speed CAN transceiver product, and the XUMA2 ordering code is stocked in volume through multiple authorized channels. Request current lot availability, MOQ and delivery terms through the quote form.

נתוני עזר הנדסיים עבור TLE7250GVIOXUMA2 — השוואה, הנחיות תכנון ומידע על תאימות.

מדריך בחירה

Choose the TLE7250GVIOXUMA2 when you need a single 1 Mbps classic CAN port on a 3.3 V or 5 V logic domain in a compact SOIC-8 footprint, and the application is automotive or industrial CAN where emissions and immunity matter. It is the right choice when your MCU lacks a 5 V tolerant CAN interface, because the dedicated VIO pin removes the level-shifter stage entirely.

Pick the TLE7250GVIOXUMA1 when the electrical function is identical but you need a different packing/ordering form for your assembly line; both share the same PG-DSO-8-16 footprint, 1 Mbps rate, 1/1 half-duplex configuration and 100 mV receiver hysteresis, so the change is a supply-form decision rather than an engineering one. The family name TLE7250GVIO is equivalent whenever the purchasing channel quotes the family rather than a specific ordering code.

Do not select this part if your network requires CAN FD data rates above 1 Mbps, or if you need galvanic isolation, dual CAN channels, or a bus operating outside the classic CAN physical layer. Those requirements call for a different transceiver family with a different package and pinout, and they cannot be dropped into the same footprint without redesign.

השוואה עם חלופות

פרמטר מוצר זה TLE7250GVIOXUMA1 TLE7250GVIO TLE7250GVIOXUMA2
Brand Infineon Infineon Infineon Infineon
Package PG-DSO-8-16 (8-SOIC, 3.90 mm width) PG-DSO-8-16 (8-SOIC) - same PG-DSO-8-16 (8-SOIC) - same PG-DSO-8-16 (8-SOIC) - same
Data Rate 1 Mbps 1 Mbps 1 Mbps 1 Mbps
Number of Drivers/Receivers 1 / 1 1 / 1 1 / 1 1 / 1
Duplex Half Half Half Half
Transceiver Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Logic (VIO) Supply 3.3 V or 5 V 3.3 V or 5 V 3.3 V or 5 V 3.3 V or 5 V
Receiver Hysteresis 100 mV 100 mV 100 mV 100 mV
Protocol / Compliance CANbus, ISO 11898-2, AEC-Q100, RoHS3 CANbus, ISO 11898-2, AEC-Q100 CANbus, ISO 11898-2, AEC-Q100 CANbus, ISO 11898-2, AEC-Q100
Operating Modes Normal / Standby Normal / Standby Normal / Standby Normal / Standby
Moisture Sensitivity Level MSL 2A (4 weeks) MSL 2A MSL 2A MSL 2A
Mounting Type Surface Mount Surface Mount Surface Mount Surface Mount

מבדילים עיקריים

  • Integrated 3.3 V / 5 V logic level adaptation on VIO (לעומתFixed 5 V-logic CAN transceivers)
  • Standby operating mode for defined low-power bus states (לעומתTransceivers without a standby input)
  • 100 mV receiver hysteresis with low-emission driver stage (לעומתTransceivers with lower hysteresis)
  • AEC-Q100 automotive qualification in an 8-pin SOIC-8 footprint (לעומתNon-automotive CAN transceivers in larger packages)

הערות תכנון

Route CANH and CANL as a tightly coupled differential pair with a constant spacing, keep the pair length matched within a few millimetres, and avoid stubs, vias and test pads on the bus legs. Place the transceiver close to the bus connector so that the unshielded run on the PCB is minimal. A common mistake is to bring CANH and CANL to the connector on separate layers, which destroys the magnetic coupling and increases radiated emissions.

Decouple the VCC and VIO pins independently with 100 nF ceramic capacitors placed directly at the pins, plus bulk capacitance close to the transceiver. Keep the ground return short and use a solid ground plane under and around the device so that bus return currents do not flow through the logic ground of the host controller. Because VIO may be tied to 3.3 V or 5 V independently of the 5 V transceiver rail, verify that the rail connected to VIO is always within the logic input thresholds before power-up sequencing.

Do not substitute a transceiver with a CAN FD data rate for this design: the TLE7250GVIOXUMA2 is specified for 1 Mbps classic CAN, and a bus running above that rate is not supported. Also confirm the standby pin state at reset. If the host MCU drives the control input at an undefined level during startup, the bus may be left active. Add a pull resistor so the transceiver is always in a defined state before the controller begins transmission.

A CAN transceiver's emissions are dominated by the common-mode voltage on the bus, which is set by the network impedance and termination. Ensure the bus is properly terminated with 120 ohm at both ends of the segment and that the stub lengths stay short, since improper termination produces reflections that increase both emissions and susceptibility. Use a common-mode choke if the harness is long or runs next to switching power stages.

מידע על תאימות

RoHS
Compliant
REACH
Unknown
AEC-Q100
Qualified
נטול עופרת
Unknown
נטול הלוגנים
Unknown
מינרלים של סכסוך
Unknown

RoHS3 compliant and AEC-Q100 qualified automotive CAN transceiver per the Infineon TLE7250GVIO product documentation and catalogue attributes. REACH status, lead-free finish statement, halogen-free declaration and conflict-minerals declaration are not confirmed in the available material.

הנתונים אומתו בתאריך: 2026-11-07 — נתונים אומתו ונערכו על ידי צוות הנדסת הרכיבים של XAIPART

חיפושים קשורים

TLE7250GVIOXUMA2 TLE7250GVIOXUMA2 datasheet TLE7250GVIOXUMA2 datasheet pdf TLE7250GVIOXUMA2 pinout TLE7250GVIOXUMA2 price TLE7250GVIOXUMA2 stock TLE7250GVIOXUMA2 equivalent TLE7250GVIOXUMA2 replacement TLE7250GVIOXUMA2 vs TLE7250GVIOXUMA1 TLE7250GVIO 1Mbps CAN transceiver TLE7250GVIO SOIC-8 CAN interface TLE7250GVIO VIO 3.3V logic adaptation Infineon TLE7250GVIOXUMA2 TLE7250GVIOXUMA2 automotive CAN node what is a CAN transceiver with standby mode

רכיבים ומונחים קשורים

Infineon TLE7250GVIOXUMA2 TLE7250GVIO TLE7250GVIOXUMA1 CAN transceiver CAN bus physical layer interface ISO 11898-2 Controller Area Network VIO 3.3 V logic level 5 V logic level half-duplex 1 Mbps data rate receiver hysteresis standby mode CANH CANL PG-DSO-8-16 SOIC-8 surface mount AEC-Q100 RoHS MSL 2A automotive electronics industrial automation Microchip Technology MC9S08PA4VTG