ADM3064EBRZ - 500 kbps RS-485 Transceiver | Analog Devices
MPN: ADM3064EBRZ ✓ सक्रियADM3064EBRZ अवलोकन
An RS-485 transceiver is an interface IC that converts logic-level digital signals into differential bus signals and reconstructs digital data from a differential bus. The ADM3064EBRZ belongs to the interface IC hierarchy, combining a line driver, line receiver, and bus protection in one package. This integration supports bidirectional, half-duplex communication over long industrial cable runs while limiting the number of components required for a robust RS-485 node.
The principal benefits include operation across a 3.0 V to 5.5 V supply, a separate VIO domain from 1.62 V to 5.5 V, ±12 kV contact-discharge ESD protection on the bus pins, and a 14-lead SOIC footprint. The VIO supply allows the digital interface to operate at a lower voltage than the transceiver supply, which is useful when the host controller uses a 1.8 V or 2.5 V logic rail. The 500 kbps speed rating targets industrial control, instrumentation, building automation, and equipment networks rather than high-speed data-center protocols.
The ADM3064E family is designed for reliable single-ended data transmission in industrial environments. Its integrated protection helps reduce damage from electrostatic discharge encountered during cable installation or industrial electrical noise events. Although protection ratings describe defined test conditions, the bus network still requires appropriate grounding, shielding, cable termination, and surge-protection measures based on the installation environment.
Typical uses include industrial PLC communication, motor-control modules, factory sensor networks, building-control equipment, and external instrument connections. At each network node, the transceiver interfaces the host UART or controller through DI, RO, and control inputs while driving or receiving on the A and B differential pair. Termination and bias resistors are normally placed only where required by the topology rather than at every node.
For layout, place the transceiver and its local bypass capacitor close together, keep the A and B traces short and closely coupled, and provide a clear return path through the reference ground connection. Follow the Analog Devices pin-description table when assigning PCB tracks, and avoid routing bus signals beneath isolated high-voltage areas. Evaluate the complete bus for termination, common-mode voltage, cable length, and propagation delay.
This product page consolidates the ADM3064EBRZ electrical characteristics, package information, drop-in alternatives, application guidance, and design considerations into an engineering-focused reference. It also identifies which functions require separate protection or filtering, helping designers distinguish integrated bus protection from complete surge protection and external galvanic isolation.
के लिए ड्रॉप-इन विकल्प ADM3064EBRZ — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस सीरीज़ के वेरिएंट
समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं ADM3064EBRZ (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Package, Transceiver Configuration.
ADM3064EARZ
✅ ड्रॉप-इनकीमत के लिए संपर्क करें
डेटाशीट देखें →ADM3064EBRZ विशेषताएं
| Product Type | RS-485 transceiver |
| Channel Count | 1 channel |
| Maximum Signaling Rate | 500 kbps |
| Maximum Data Rate | 50 Mbps |
| VCC Operating Voltage Range | 3.0 V to 5.5 V |
| VIO Operating Voltage Range | 1.62 V to 5.5 V |
| Bus-Pin ESD Contact Discharge | ±12 kV |
| ESD Test Method | IEC 61000-4-2 |
| पैकेज | 14-lead narrow-body SOIC |
| माउंटिंग प्रकार | Surface mount |
| Transceiver Configuration | 1/1 full RS-485 transceiver |
| Supply Compatibility | 3.0 V to 5.5 V |
| Logic Supply Option | 1.62 V to 5.5 V VIO |
ADM3064EBRZ 14-lead narrow-body soic पिन कॉन्फ़िगरेशन गाइड
ADM3064EBRZ (14-lead narrow-body soic पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: ADM3064EBRZ.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
ADM3064EBRZ के लिए उपयुक्त है 6 अनुप्रयोगs: Industrial PLC Communication, Factory Sensor Network, Building Automation Controller, Motor Control Interface, Test and Measurement Instrument, External Data Acquisition Unit.
Industrial PLC Communication
The ADM3064EBRZ fits a PLC or remote I/O node that communicates through an RS-485 network at up to 500 kbps. Its 3.0 V to 5.5 V transceiver supply supports conventional industrial rails, while the 1.62 V to 5.5 V VIO range can connect to a lower-voltage controller. The ±12 kV IEC 61000-4-2 contact-discharge protection on the bus pins improves resilience to electrostatic discharge encountered during installation and maintenance. In a half-duplex design, the controller drives DI, monitors RO, and controls the transceiver while the A and B pair connects to the field bus.
अनुशंसित
Factory Sensor Network
The ADM3064EBRZ is appropriate for distributed sensors and condition-monitoring equipment connected to an industrial RS-485 backbone. A 500 kbps maximum signaling rate is suitable for polling-based networks carrying sensor commands and periodic measurements, while the separate VIO supply allows the digital side to match the sensor hub’s logic voltage. Bus-pin ESD protection of ±12 kV under IEC 61000-4-2 helps protect exposed field wiring. Designers should still place termination only at appropriate bus endpoints and evaluate biasing for networks that can become idle when all nodes stop transmitting.
अनुशंसित
Building Automation Controller
The ADM3064EBRZ can connect HVAC controllers, access-control panels, lighting gateways, and environmental sensors using an RS-485 backbone. Its 14-lead narrow-body SOIC package simplifies assembly into compact control boards, and the 500 kbps signaling rate accommodates typical building-management message traffic. The 1.62 V to 5.5 V VIO option is useful when the central controller uses a lower-voltage logic rail. For cables routed through building construction, retain the ±12 kV contact-discharge protection but determine whether additional surge arrestors, isolation, or shielding are needed for the installation.
अनुशंसित
Motor Control Interface
The ADM3064EBRZ is useful in motor-drive and inverter-support modules where a control processor communicates with remote drives, brakes, or position sensors over an RS-485 link. The 500 kbps rate provides sufficient bandwidth for setpoints, status, and diagnostic traffic without requiring a high-speed differential standard. Operating from 3.0 V to 5.5 V supports embedded industrial systems, while the separated VIO rail can simplify controller interfacing. Keep the A and B routing short, preserve a continuous ground reference, and evaluate the bus against the drive manufacturer’s grounding and termination recommendations.
अनुशंसित
Test and Measurement Instrument
The ADM3064EBRZ can serve as the isolated-by-cable-interface element in laboratory and field-test equipment that exchanges commands or measurement records with an RS-485 master. The 500 kbps signaling rate is suitable for command-oriented laboratory communication, and the separate 1.62 V to 5.5 V VIO supply supports processors operating below 3.3 V. The ±12 kV IEC 61000-4-2 contact-discharge rating protects the bus pins during repeated cable insertion. For bench instruments connected to unknown external cables, engineers should evaluate isolation, grounding, and additional surge protection based on the complete measurement system.
अनुशंसित
External Data Acquisition Unit
The ADM3064EBRZ fits compact remote data-acquisition units that send sensor readings to a central controller over an RS-485 bus. Its 500 kbps signaling rate supports periodic multi-drop data collection, while the 3.0 V to 5.5 V supply and independent VIO domain support mixed-voltage logic partitioning. The integrated ±12 kV contact-discharge protection is valuable where the acquisition unit connects to long external sensor cables. The board designer should use low-divergence A and B routing, provide a solid reference-ground connection, and avoid placing termination resistors at every node because excessive termination can reduce the usable bus voltage.
अनुशंसित
अनुशंसित उत्पादों का सारांश
के लिए इंजीनियरिंग संदर्भ डेटा ADM3064EBRZ — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद | ADM3064EARZ |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | 14-lead narrow-body SOIC | 14-lead narrow-body SOIC |
| Product Type | RS-485 transceiver | RS-485 transceiver |
| Channel Count | 1 channel | 1 channel |
| Maximum Signaling Rate | 500 kbps | 500 kbps |
| Temperature Grade | B-grade variant | E-grade variant |
मुख्य विशेषताएँ
- Separate low-voltage logic supply (बनामADM3064EARZ)
- Integrated bus-contact ESD protection (बनामADM3064EARZ)
- Industrial speed with compact logic integration (बनामADM3064EARZ)
डिज़ाइन नोट्स
Route the A and B bus conductors as a closely coupled differential pair, with substantially uniform spacing along the board and away from high-current switching paths. Connect the transceiver ground reference to the equipment ground using the layout arrangement specified by the Analog Devices application guidance. Avoid creating a large copper void under the device, and place local supply bypassing directly between the appropriate supply pins and ground to minimize high-frequency supply impedance.
Do not treat the integrated ±12 kV IEC 61000-4-2 contact-discharge rating as complete lightning or industrial-surge protection. Determine whether the external cable can receive larger surge events, and add appropriately rated protection when required. Likewise, place termination at the physical ends of the bus and use bias resistors only when the network needs defined idle state. Incorrect termination or excessive loading can reduce differential voltage and cause unreliable communication.
For a 500 kbps bus, evaluate propagation delay across the complete network rather than relying only on nominal cable length. Keep transceiver enable and receive-control timing synchronized with UART framing, account for bus turnaround delay in half-duplex communication, and use a differential receiver with hysteresis. If the cable crosses large ground-potential differences, add isolation rather than relying on the transceiver’s internal ESD protection.
अनुपालन जानकारी
The manufacturer product page and product listings were used for functional, electrical, and package information. A definitive component-specific RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive-qualification declaration was not identified in the available documentation.