AT90CAN128-16MI - 16MHz AVR CAN MCU | Microchip Technology
MPN: AT90CAN128-16MI ✓ सक्रियAT90CAN128-16MI अवलोकन
An 8-bit microcontroller is a programmable semiconductor containing a processor core, nonvolatile program memory, data memory, and peripherals on one device. The AT90CAN128 belongs to the AVR 90CAN product family and combines the AVR enhanced RISC architecture with dedicated CAN communications. Its CAN controller supports CAN V2.0A and V2.0B protocols, allowing the MCU to participate in industrial, automotive, and embedded control networks through an external CAN transceiver.
Key features include 128 KB of in-system-programmable flash with read-while-write operation, 4 KB of EEPROM for nonvolatile parameters, 4 KB of SRAM for working data, and 53 general-purpose I/O lines. The device also provides 32 general-purpose working registers and 133 powerful instructions. Its integrated communication and timing resources reduce the need for separate peripheral devices in systems requiring CAN, UART, PWM, or serial sensor connectivity.
The AVR architecture uses a Harvard-style memory organization and an enhanced reduced-instruction-set-computing core designed for efficient instruction execution. In-system programming allows firmware to be written or updated through the programming interface without removing the chip. Read-while-write flash operation permits the program memory to remain accessible during qualifying update operations, supporting applications that need flexible field firmware maintenance.
Typical uses include industrial CAN controllers, automotive body and comfort modules, building automation equipment, motor-control systems, diagnostic instruments, and CAN-connected sensor nodes. The combination of 53 I/O lines, two USARTs, four timer/counters, and CAN connectivity is particularly useful when a compact controller must operate several peripherals while maintaining a deterministic network interface.
PCB design should preserve the exposed-pad land pattern and follow the manufacturer’s thermal and decoupling guidance. Place the input bypass capacitor close to the supply pins, connect the exposed pad to the ground plane with adequate thermal-via density, and keep the CAN RX and TX traces away from noisy switching nodes. Firmware development should use AVR-compatible toolchains and verify the device’s fuse, clock, and CAN timing configuration before field deployment.
This page combines the AT90CAN128-16MI specifications, application guidance, package details, interface resources, and confirmed same-footprint alternatives to support component selection and hardware implementation. The 64-QFN land pattern and exposed pad must be treated as one thermal and electrical footprint rather than as an optional feature.
के लिए ड्रॉप-इन विकल्प AT90CAN128-16MI — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस सीरीज़ के वेरिएंट
समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं AT90CAN128-16MI (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न CAN Controller, Core Architecture, Instruction Set, Mounting Type, Package.
AT90CAN128-16MU
✅ ड्रॉप-इनकीमत के लिए संपर्क करें
डेटाशीट देखें →AT90CAN128-16MI Maximum Ratings और Electrical Characteristics
| Core Architecture | 8-bit AVR enhanced RISC |
| अधिकतम क्लॉक फ़्रीक्वेंसी | 16 MHz |
| Program Memory | 128 KB in-system-programmable flash |
| Flash Organization | 128K × 8 bits |
| EEPROM Memory | 4 KB |
| SRAM Memory | 4 KB |
| General-Purpose I/O Lines | 53 lines |
| General-Purpose Working Registers | 32 registers |
| Instruction Set | 133 powerful instructions |
| CAN Controller | CAN V2.0A and CAN V2.0B compliant |
| UART Interfaces | 2 USARTs |
| Timer/Counters | 4 with compare modes and PWM |
| Serial Interface | Byte-oriented Two-wire Serial interface |
| Real-Time Counter | 1 real-time counter |
| Operating Voltage Range | 2.7 V to 5.5 V |
| Program Memory Feature | Read-while-write capable |
| पैकेज | 64-QFN, 9 mm × 9 mm |
| Package Type Code | HVQCCN |
| Terminal Count | 64 terminals |
| माउंटिंग प्रकार | No-lead surface mount |
| Temperature Grade | Industrial |
AT90CAN128-16MI hvqccn पिन कॉन्फ़िगरेशन गाइड
AT90CAN128-16MI (hvqccn पैकेज) के लिए पिन कॉन्फ़िगरेशन। इस डिजिटल IC में GPIO, संचार इंटरफ़ेस (UART, SPI, I2C) और पावर पिन शामिल हैं। वैकल्पिक पिन फ़ंक्शन और कॉन्फ़िगरेशन विकल्पों के लिए निर्माता डेटाशीट देखें। एम्बेडेड सिस्टम डिज़ाइन और PCB लेआउट के लिए आवश्यक।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: AT90CAN128-16MI.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
AT90CAN128-16MI के लिए उपयुक्त है 6 अनुप्रयोगs: Industrial CAN Controller, Automotive Body Control Module, Building Automation Node, Motor Control and PWM System, CAN Diagnostic Instrument, CAN-Connected Sensor Node.
Industrial CAN Controller
The AT90CAN128-16MI fits industrial CAN controllers because its integrated CAN V2.0A/V2.0B controller operates alongside a 16 MHz AVR core and 53 general-purpose I/O lines. The microcontroller can manage digital machine inputs and outputs while exchanging supervisory data through a CAN transceiver connected to the CANRX and CANTX pins. Four timer/counters with compare and PWM modes support timing tasks, and two USARTs provide additional serial channels. With 128 KB of ISP flash and 4 KB of SRAM, the device has useful room for protocol handlers, diagnostics, and application firmware. The 2.7 V to 5.5 V operating range supports industrial logic systems, while the 64-QFN package keeps the controller compact. Designers should verify CAN bit timing, transceiver standby behavior, termination, and fault-handling requirements before deployment.
अनुशंसित
Automotive Body Control Module
The AT90CAN128-16MI is well suited to body and comfort control modules that combine CAN communication with conventional discrete I/O. Its 53 general-purpose I/O lines can interface with switches, lamps, solenoids, and sensing circuits, while the CAN controller supports V2.0A and V2.0B communication rules for vehicle-network nodes. The 16 MHz AVR core executes control logic, the four timer/counters provide PWM and event timing, and the two USARTs support diagnostic or external-module links. At 128 KB, the in-system-programmable flash supports field-updateable application and diagnostic code, and read-while-write operation can assist controlled firmware maintenance. The 64-QFN 9 mm × 9 mm package also limits board area. Production design must confirm the exact automotive qualification status and environmental test requirements for the selected ordering code.
अनुशंसित
Building Automation Node
The AT90CAN128-16MI can serve as a building-automation node that coordinates lighting, access, HVAC, and environmental sensors over a CAN network. Its 53 I/O lines provide ample connections for digital inputs, relay-control outputs, and status feedback, while the 16 MHz AVR core performs local control without continuous network activity. The integrated real-time counter supports time-based scheduling, four timer/counters can generate PWM or capture events, and two USARTs can connect to local displays or service tools. The 128 KB ISP flash and 4 KB EEPROM provide separate space for firmware and persistent configuration. Low-power operation is useful in distributed building systems where nodes may spend substantial time waiting for events. The 2.7 V to 5.5 V supply range permits integration with common low-voltage control rails, while the 64-QFN package supports compact panel-mounted electronics.
अनुशंसित
Motor Control and PWM System
The AT90CAN128-16MI supports compact motor-control and PWM systems where deterministic timing, network communication, and local I/O are required. Four flexible timer/counters provide compare modes and PWM outputs, making them suitable for actuator command generation, speed-related timing, or periodic sampling. The 16 MHz AVR core can execute the control loop, while the CAN V2.0A/V2.0B controller enables parameter exchange with a higher-level controller or diagnostics equipment. Two USARTs and the byte-oriented Two-wire Serial interface provide additional paths for sensors, debug tools, or local service connections. Its 128 KB flash accommodates application and update code, while 4 KB SRAM supports working state. Layout should isolate sensitive timing signals from CAN and switching-node traces, and the exposed pad should be tied to ground with sufficient thermal vias for the intended load.
अनुशंसित
CAN Diagnostic Instrument
The AT90CAN128-16MI is appropriate for a portable CAN diagnostic instrument that needs protocol handling, local display or keyboard support, and field-programmable firmware. The CAN controller handles V2.0A and V2.0B frame processing, while two USARTs can drive a local display, connect a host computer, or serve an external sensor. Four timer/counters support timeout handling, pulse capture, and periodic background tasks. Its 128 KB of ISP flash is sufficient for a boot loader and application layers, while 4 KB of EEPROM can retain device settings, calibration values, and diagnostic logs between power cycles. The 16 MHz processor provides a practical balance of processing capability and power consumption for an embedded instrument. Designers should plan a robust CAN transceiver, galvanic-isolation strategy where required, ESD protection, and firmware update mechanism based on the product’s operating environment.
अनुशंसित
CAN-Connected Sensor Node
The AT90CAN128-16MI works well in a distributed sensor node that collects digital measurements and publishes them through a CAN network. Its 53 I/O lines can connect discrete sensors, switches, and status indicators, while the Two-wire Serial interface can support compatible serial sensors or external expansion. The real-time counter and four timer/counters support periodic acquisition, input capture, and PWM output, and the two USARTs provide additional communication flexibility. A 16 MHz AVR core handles preprocessing and protocol formatting without requiring a separate processor, while 128 KB of flash and 4 KB of SRAM accommodate application logic and data buffering. The 2.7 V to 5.5 V operating range simplifies integration into low-voltage sensor systems. Low-power design should disable unused peripherals, retain the CAN interface only when required, and validate wake-up behavior and bus-fault recovery across the complete temperature range.
अनुशंसित
अनुशंसित उत्पादों का सारांश
के लिए इंजीनियरिंग संदर्भ डेटा AT90CAN128-16MI — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद | AT90CAN128-16MU |
|---|---|---|
| Brand | Microchip Technology | Microchip Technology |
| Package | 64-QFN (9 mm × 9 mm) | 64-QFN (9 mm × 9 mm) |
| Core Architecture | 8-bit AVR enhanced RISC | 8-bit AVR enhanced RISC |
| Maximum Clock Frequency | 16 MHz | 16 MHz |
| Program Memory | 128 KB ISP flash | 128 KB ISP flash |
| EEPROM Memory | 4 KB | 4 KB |
| SRAM Memory | 4 KB | 4 KB |
| General-Purpose I/O Lines | 53 lines | 53 lines |
| CAN Controller | CAN V2.0A and CAN V2.0B compliant | CAN V2.0A and CAN V2.0B compliant |
| UART Interfaces | 2 USARTs | 2 USARTs |
| Timer/Counters | 4 with compare modes and PWM | 4 with compare modes and PWM |
| Operating Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
मुख्य विशेषताएँ
- Combines CAN networking with extensive general-purpose I/O (बनामAT90CAN128-16MU)
- Large in-system-programmable memory for field-capable firmware (बनामAT90CAN128-16MU)
- Compact integrated peripheral set (बनामAT90CAN128-16MU)
डिज़ाइन नोट्स
Follow the manufacturer’s 64-QFN land pattern and exposed-pad layout exactly. The exposed pad is part of the thermal path and should be connected to the ground plane with a suitable array of thermal vias. Do not route high-current or high-voltage traces beneath the MCU footprint unless the package design explicitly permits it. Preserve component placement clearance around the exposed pad and verify the solder mask and paste apertures against the current package drawing before releasing the PCB.
Place the local supply bypass capacitor immediately adjacent to the MCU supply pins and connect it to the same ground reference with a short, low-inductance path. Keep the CAN transceiver, CANRX connection, and CANTX connection away from switching-regulator inductors and high-current motor-drive traces. If the board supports analog sensing, maintain separation between sensitive input routes and the CAN and power stages to reduce coupling from fast edge transitions.
Do not treat every AT90CAN128 ordering code as mechanically interchangeable. AT90CAN128-16AU and AT90CAN128-16AJ use a 64-TQFP package, while AT90CAN128-16MI uses a 64-QFN 9 mm × 9 mm package. Before substituting a part, compare the footprint, exposed-pad requirement, temperature grade, packing method, and firmware target. An electrically similar MCU with a different package can require a new PCB rather than a component replacement.
Design the supply for the complete 2.7 V to 5.5 V operating range and include margin for startup and bus-transient effects at the device pins. Use the manufacturer’s recommended decoupling network and confirm that the regulator can supply the MCU, CAN transceiver, pull-up networks, and attached loads without excessive droop. Check brownout and watchdog behavior as part of the power-fail strategy, particularly when the node must enter a safe state after supply interruption.
Apply the CAN transceiver’s system-design requirements for termination, split termination, common-mode chokes, and protection devices. The MCU supplies digital CAN logic signals, while the physical bus interface is implemented by an external transceiver. Review propagation delay, bus timing, and fault recovery against the selected transceiver and network topology. Avoid long unprotected stubs and maintain a continuous ground reference beneath the bus interface to reduce susceptibility to electromagnetic interference.
अनुपालन जानकारी
The manufacturer product information identifies AT90CAN128-16MI as industrial grade but does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status for this exact ordering code.