Analog Devices

ICL7109CPL+2 - 12-Bit Dual-Slope ADC | Analog Devices

MPN: ICL7109CPL+2 ✓ सक्रिय
5 V Vdss Low Id 40-pin PDIP, 0.600 in (15.24 mm) width Package
न्यूनतम ऑर्डर मात्रा: 1 |

ICL7109CPL+2 अवलोकन

Analog Devices ICL7109CPL+2 is a monolithic 12-bit dual-slope analog-to-digital converter with one differential input, three-state binary outputs, and a 40-pin PDIP package. It is designed for low-cost data acquisition, panel meters, process measurement, and microprocessor or UART interfacing, combining a 12-bit conversion result with separate polarity and over-range indications.

An ADC is an integrated circuit that converts an analog voltage into a digital code. The ICL7109 belongs to the dual-slope integrating ADC category, a technique that uses fixed and integration periods to average input voltage over time. In the broader hierarchy, the ICL7109 is an ADC, then a data-conversion IC, then an integrated circuit used for electronic measurement and control.

The key features of the ICL7109CPL+2 include 12-bit resolution, one differential analog input, dual-slope conversion, three-state binary outputs, microprocessor-bus compatibility, and UART-oriented operation. Its outputs can be connected directly to a microprocessor bus, while the zero-integrator phase reduces over-range hangover, crosstalk, and hysteresis effects. These characteristics make one converter per channel practical when multiplexing a shared analog front end would otherwise add complexity.

The differential input architecture supports measurement of signals referenced to a midpoint or other common reference rather than ground alone. Low input bias current and low power consumption are useful in sensor-oriented systems, while the zero-integrator phase helps one channel recover promptly after an over-range condition. Designers should still observe the timing relationships among the conversion-control, busy, polarity, over-range, and output signals when connecting the device to a bus or UART.

Typical uses include digital panel instruments, temperature measurement systems, laboratory data loggers, industrial process monitors, and low-rate sensor interfaces. The ICL7109CPL+2 is especially suitable when a 12-bit result, tri-state bus control, and simple integration are more valuable than conversion speed. For battery-powered instruments, its low power consumption helps limit energy use, although external reference and source-impedance requirements still determine the achievable accuracy.

PCB implementation should preserve the pin assignments and analog layout of the manufacturer's 40-pin PDIP footprint. Keep the analog input path short, use suitable bypass capacitors at the supply pins, and route digital control and data outputs away from sensitive input nodes. Because this is a dual-slope converter, acquisition time and input settling must be coordinated with the conversion timing rather than optimized solely for instantaneous conversion latency.

This product overview combines the manufacturer product information with distributor technical listings, replacement cross-references, and practical guidance for evaluating the ICL7109CPL+2 in slow, precision-oriented data acquisition systems.

के लिए ड्रॉप-इन विकल्प ICL7109CPL+2 — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

इस सीरीज़ के वेरिएंट

समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं ICL7109CPL+2 (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Package, Resolution, Conversion Architecture.

Analog Devices
Package: 40-pin PDIP
Resolution: 3.5 digits
Conversion Architecture: Dual-slope conversion
इसके साथ तुलना करें ICL7109CPL+2 →

ICL7109CPL+

✅ ड्रॉप-इन
📦 40-pin PDIP
Same ICL7109 12-bit dual-slope architecture and 40-pin PDIP format; ordering suffix and temperature-grade details require confirmation

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

ICL7109CPL

✅ ड्रॉप-इन
Maxim Integrated
📦 40-pin PDIP
12 bit · 1 differential · Dual-slope integrating · 30 samples/second · Dual Slope with zero-integrator phase · Parallel (3-state binary) · Binary + polarity + over-range · Differential

कीमत के लिए संपर्क करें

डेटाशीट देखें →

TC7109CPL

✅ ड्रॉप-इन
📦 40-pin PDIP
Cross-brand 12-bit dual-slope converter with parallel and UART modes; interface timing and output details should be compared with the ICL7109

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

ICL7106SCPL

✅ ड्रॉप-इन
Harris Corporation
📦 40-pin PDIP
3.5-digit dual-slope A/D converter · Multiplexed LCD · Parallel display output · 1 channel · 16-bit internal conversion · Approximately 3 samples per second · 15 V · 0°C to 70°C

कीमत के लिए संपर्क करें

डेटाशीट देखें →

ICL7136CPL+

✅ ड्रॉप-इन
Analog Devices
📦 40-pin PDIP
3.5-digit monolithic analog-to-digital converter · 3.5 digits · Dual-slope conversion · Differential or single-ended · Very high input impedance · Seven-segment decoders, display drivers, voltage reference, and clock · Direct non-multiplexed LCD display drive · Low-power A/D converter

कीमत के लिए संपर्क करें

डेटाशीट देखें →

ICL7109CPL+2 Maximum Ratings और Electrical Characteristics

रेज़ोल्यूशन 12 bit
Conversion Architecture Dual-slope
Analog Input Channels 1 channel
Input Type Differential
Digital Output 12-bit binary with polarity and over-range outputs
Output Interface 3-state binary parallel output
सप्लाई वोल्टेज 5 V
पैकेज 40-pin PDIP, 0.600 in (15.24 mm) width
माउंटिंग प्रकार Through-hole
Terminal Count 40 terminals
Temperature Grade Commercial
Zero-Integrator Phase Yes
Over-Range Hangover Reduction Yes
Microprocessor Interface Direct microprocessor-bus compatible
UART Interface Supported
Power Consumption Low
Input Bias Current Low

ICL7109CPL+2 40-pin pdip, 0.600 in (15.24 mm) width पिन कॉन्फ़िगरेशन गाइड

ICL7109CPL+2 (40-pin pdip, 0.600 in (15.24 mm) width पैकेज) के लिए पिन कॉन्फ़िगरेशन। इस एनालॉग कंपोनेंट में इनपुट, आउटपुट और पावर सप्लाई पिन हैं। ऑफ़सेट नल, कम्पनसेशन और एनेबल पिन कॉन्फ़िगरेशन के लिए निर्माता डेटाशीट देखें। सिग्नल कंडीशनिंग और एम्प्लीफ़ायर सर्किट के लिए आदर्श।

ICL7109CPL+2 के लिए 40-pin pdip, 0.600 in (15.24 mm) width पैकेज पिनआउट आरेख

इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: ICL7109CPL+2.

देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।

सामान्य अनुप्रयोग

ICL7109CPL+2 के लिए उपयुक्त है 6 अनुप्रयोगs: Digital Panel Meters, Temperature Measurement Systems, Industrial Process Monitors, Laboratory Data Loggers, Portable Environmental Instruments, Microprocessor-Based Metering.

📺

Digital Panel Meters

The ICL7109CPL+2 fits digital panel meters because its 12-bit dual-slope conversion provides adequate resolution for many pressure, temperature, and level displays while keeping the signal path straightforward. The differential input can be arranged around a midpoint reference to suit the sensor front end, and the three-state binary outputs can drive a display controller through a controlled bus. The zero-integrator phase helps the converter recover promptly after an over-range input, reducing visible channel-transition errors in sequential measurements. Selection should focus on the required update rate, display refresh behavior, and reference accuracy rather than high-speed sampling performance.

🌡️

Temperature Measurement Systems

The ICL7109CPL+2 is suitable for temperature measurement when the sensor produces a differential or midpoint-referenced analog voltage. Its 12-bit resolution supports a useful range of displayed temperature detail, while dual-slope conversion integrates the input over time and is well matched to relatively slow thermal signals. Low input bias current helps preserve the accuracy of high-impedance sensors, and low power consumption is advantageous in portable instruments. A stable voltage reference and carefully selected input network remain necessary because sensor gain, reference drift, and electrical noise can dominate the overall temperature error.

🏭

Industrial Process Monitors

The ICL7109CPL+2 can serve as the measurement core of an industrial process monitor for slow-changing variables such as tank level, pressure, flow proxies, or transducer output. The differential input allows the analog stage to reject common-mode disturbance, while the 12-bit code provides sufficient measurement granularity for many industrial readouts. The converter's low power use supports compact panel-mounted instruments, and the zero-integrator phase improves recovery after an over-range event. Designers should still provide input protection, filtering, reference conditioning, and isolation where the process environment requires it.

🖥️

Laboratory Data Loggers

The ICL7109CPL+2 is useful in laboratory data loggers that sample slow analog channels rather than high-frequency waveforms. Its 12-bit resolution, low power consumption, and low input bias current support battery-powered or compact multi-channel instruments. The three-state outputs allow multiple converters to share bus-control logic when channel isolation is handled externally, while the differential input helps reject common-mode noise in longer sensor cables. Because dual-slope conversion has an integration interval, the logger must allow sufficient settling and acquisition time before reading the conversion-complete indication.

🧩

Portable Environmental Instruments

The ICL7109CPL+2 is appropriate for portable environmental instruments that monitor battery-powered sensors and require a readable numeric result rather than waveform capture. Its low-power operating behavior helps extend runtime, while the 12-bit dual-slope ADC can measure temperature, humidity, gas, or pressure outputs after appropriate signal conditioning. The differential input supports sensors centered around a reference or bridge excitation, provided the selected reference and input levels stay within the converter's electrical limits. Mechanical protection, moisture-resistant construction, and stable sensor excitation are typically more important to field accuracy than additional converter speed.

🔧

Microprocessor-Based Metering

The ICL7109CPL+2 can connect directly to a microprocessor bus because it provides 12-bit binary, polarity, over-range, and three-state output signals. This arrangement suits metering equipment in which the host controller performs calibration, display formatting, alarms, and communication. The converter's differential input reduces the need for a ground-referenced input stage when the sensor signal is centered, while its low power use limits system overhead. The interface design must respect the converter's busy and control timing and account for the acquisition interval required by its dual-slope conversion process.

What is the operating voltage of ICL7109CPL+2?
The ICL7109CPL+2 operates from a 5 V supply. According to the Analog Devices ICL7109 product information, this is a monolithic 12-bit ADC intended for low-power measurement systems. The 5 V operating requirement simplifies supply planning for legacy instrumentation, although bypass capacitors and correct grounding remain essential for stable conversion results.
What is the resolution of ICL7109CPL+2?
The ICL7109CPL+2 provides 12-bit resolution with a single differential input. The Analog Devices product page describes it as a 12-bit A/D converter with three-state binary outputs, and distributor technical listings identify the dual-slope conversion architecture. This resolution is suitable for many panel meters, process monitors, and slow sensor-acquisition systems.
Where can I download the ICL7109CPL+2 datasheet PDF?
The official ICL7109 documentation is available through the Analog Devices product page at https://www.analog.com/en/products/icl7109.html. Select the Data Sheet resource associated with the ICL7109 to obtain the manufacturer documentation. Use the ICL7109 pin description and electrical tables when assigning functions and calculating external component values for the ICL7109CPL+2.
Where can I find the ICL7109CPL+2 pinout?
Use the ICL7109 pin-description table in the Analog Devices manufacturer datasheet for the authoritative 40-pin PDIP assignment. The ICL7109CPL+2 is a 40-pin PDIP device, but a verified numbered pin list is not reproduced on this page. Confirm analog inputs, reference pins, supply pins, converter timing, polarity, over-range, and three-state data-output connections before laying out the PCB.
What is the best drop-in replacement for ICL7109CPL+2?
The closest documented drop-in candidates are ICL7109CPL+ and ICL7109CPL from the same ICL7109 family, both using a 40-pin PDIP format. TC7109CPL is a cross-brand 12-bit ADC alternative that also uses a 40-pin PDIP package, but its bus and timing behavior should be checked against the original design before substitution. Confirm every pin and electrical limit in the manufacturer datasheet.
Is ICL7109CPL+2 suitable for panel meters?
The ICL7109CPL+2 is suitable for low-speed digital panel meters because it combines a 12-bit result, differential input, three-state binary outputs, and low power consumption. Its dual-slope architecture favors stable readings and simple integration rather than high sample rates. A temperature-grade, low-drift reference and appropriate front-end filtering should be selected for accurate measurements.
ICL7109CPL+2 vs ICL7109CPL+ - which is better?
The ICL7109CPL+2 is the temperature-grade or commercial-grade ordering option documented as ICL7109CPL+2, while ICL7109CPL+ is another ICL7109 ordering designation. Both are described as 12-bit, three-state-output ADCs in 40-pin PDIP packages. Check the manufacturer ordering table for the exact grade and temperature coverage before deciding between them.
ICL7109CPL+2 vs TC7109CPL - which is better for a UART design?
The ICL7109CPL+2 is preferable when preserving the original Maxim ICL7109 behavior is the priority, while TC7109CPL is a possible 40-pin PDIP substitute for a compatible UART-oriented design. The TC7109CPL comparison describes direct-mode parallel control and handshake-mode UART operation. Verify pin levels, timing, output coding, and acquisition requirements before production use.
When should I choose ICL7109CPL+2 over ICL7109CPL?
Choose ICL7109CPL+2 when the exact ordered ICL7109 variant is required by the component specification, particularly when its temperature grade or production configuration matters. ICL7109CPL may be considered for a redesigned or legacy board after the ordering codes, temperature range, and electrical limits are compared. Both use the same broad 40-pin PDIP family, so PCB reuse still requires a full pin-by-pin review.
Is ICL7109CPL+2 the same as ICL7109CPL+?
No ordering designation should be treated as identical without checking the ICL7109 selection table. ICL7109CPL+2 and ICL7109CPL+ are closely related 40-pin PDIP versions of the 12-bit converter, but suffix differences can identify a different grade or operating-temperature option. Use the manufacturer ordering information to confirm the electrical and environmental requirements for your production build.
What can replace ICL7109CPL+2?
ICL7109CPL+ and ICL7109CPL are the closest same-family replacements identified for the ICL7109CPL+2, while TC7109CPL offers a cross-brand 40-pin PDIP path for designs whose bus and timing requirements are compatible. No replacement should be approved from package shape alone. Compare analog polarity, reference connection, converter timing, output coding, control levels, and acquisition behavior in the manufacturer datasheets.
What are the key specifications of ICL7109CPL+2 that engineers should know?
The ICL7109CPL+2 is a 5 V, 12-bit, single-input differential dual-slope ADC in a 40-pin PDIP package. Its principal interface features are three-state binary outputs, polarity and over-range indications, direct microprocessor-bus compatibility, and UART support. The zero-integrator phase is designed to reduce over-range hangover, crosstalk, and hysteresis effects in multichannel or sequential measurement systems.
What is the best Analog Devices equivalent for ICL7109CPL+2?
The closest Analog Devices ordering choices identified are ICL7109CPL+ and ICL7109CPL, which retain the ICL7109 architecture and 40-pin PDIP format. Their exact grade, operating-temperature range, and orderable status must be checked in the Analog Devices product page and ordering table. They are preferable to an unrelated converter when maintaining the existing PCB and conversion behavior is important.
Where to buy ICL7109CPL+2 online?
Use the Request a Quote form on this page to request ICL7109CPL+2 availability, quantity breaks, and current lead time. The manufacturer identifies the ICL7109 as a production device, while distribution listings cover the exact ICL7109CPL+2 ordering code. Quote requests should state the required quantity, shipment destination, and whether reel, tube, or other approved packaging is needed.
How much does ICL7109CPL+2 cost and what is its lead time?
Current pricing and production lead time for ICL7109CPL+2 should be requested through the Request a Quote form on this page. The form can return current quantity pricing, stock status, and delivery timing for the exact ordered part. Specify the required quantity and packaging preference so the quotation reflects the same configuration intended for production.

के लिए इंजीनियरिंग संदर्भ डेटा ICL7109CPL+2 — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose the ICL7109CPL+2 when maintaining the original ICL7109 behavior in a 40-pin PDIP legacy design is important. Its 12-bit dual-slope conversion, differential input, three-state outputs, polarity and over-range signals, and zero-integrator phase make it appropriate for panel meters, process monitors, temperature instruments, and slow sensor loggers. ICL7109CPL+ or ICL7109CPL are the first choices for an ICL7109-family replacement when ordering grade and temperature coverage are confirmed. Consider TC7109CPL when its parallel and UART timing have been validated against the board and a cross-brand sourcing strategy is desired. ICL7106SCPL and ICL7136CPL require more extensive schematic and timing review because related resolution and package size alone do not establish full pin compatibility. For production safety, compare every pin, voltage level, output code, acquisition interval, and temperature requirement before approving any substitute.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद ICL7109CPL+ ICL7109CPL TC7109CPL ICL7106SCPL ICL7136CPL
Brand Analog Devices Analog Devices Analog Devices Microchip Technology Analog Devices Analog Devices
Package 40-pin PDIP 40-pin PDIP 40-pin PDIP 40-pin PDIP 40-pin PDIP 40-pin PDIP
Resolution 12 bit 12 bit 12 bit 12 bit 12 bit 12 bit
Conversion Architecture Dual-slope Dual-slope Dual-slope Dual-slope Dual-slope Dual-slope

मुख्य विशेषताएँ

  • Maintains the established ICL7109 conversion and bus behavior (बनामTC7109CPL)
  • Uses the same 40-pin PDIP footprint as closely related ICL7109 variants (बनामICL7109CPL)
  • Differential input supports common-mode rejection (बनामICL7106SCPL)
  • Zero-integrator phase improves recovery after overload (बनामICL7136CPL)

डिज़ाइन नोट्स

Route the differential input and reference connections away from the switching or high-current return paths of the surrounding circuit. Place the input-network and reference-bypass components close to their associated pins, and keep the analog ground path compact. Although the ICL7109CPL+2 is a through-hole PDIP device, careful analog layout remains necessary because long input tracks can pick up noise that appears directly in the 12-bit conversion result.

Coordinate conversion control, busy status, and data acquisition so that the input has settled before the integration interval begins. A dual-slope converter averages for a defined period, but it cannot correct a source that has already charged or discharged an external capacitor incorrectly. Review the input impedance, acquisition interval, reference stability, and polarity handling in the manufacturer datasheet before setting the measurement timing.

Do not treat a 40-pin PDIP outline as proof of drop-in compatibility. Verify analog input polarity, reference connections, control polarity, output encoding, and the meaning of the polarity and over-range signals for each candidate. A substitution also requires checking supply limits and temperature grade. For legacy production boards, retain the original ICL7109 when any of these functions cannot be proven equivalent.

Decouple the supply pins close to the package using the capacitance and ESR characteristics specified by the Analog Devices datasheet. Keep the analog supply return path distinct from noisy digital currents where the board architecture permits it. A stable low-noise reference is as important as supply regulation because reference error directly limits the accuracy of the 12-bit result.

अनुपालन जानकारी

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

The commercial-grade legacy ICL7109 product is not identified as an automotive-qualified AEC-Q100 device. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer or current material declaration.

डेटा सत्यापन तिथि: 2026-11-24 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

ICL7109CPL+2 datasheet ICL7109CPL+2 pinout ICL7109CPL+2 datasheet pdf ICL7109CPL+2 equivalent ICL7109CPL+2 replacement ICL7109CPL+2 cross reference ICL7109CPL+2 vs TC7109CPL ICL7109CPL+2 40 pin PDIP ICL7109CPL+2 price ICL7109CPL+2 stock Analog Devices ICL7109CPL+2 ICL7109 12 bit ADC ICL7109 differential input ADC ICL7109 panel meter application ICL7109 UART interface

संबंधित कंपोनेंट्स और शब्द

Analog Devices Maxim Integrated ICL7109CPL+2 ICL7109CPL+ ICL7109CPL TC7109CPL ICL7106SCPL ICL7136CPL analog-to-digital converter ADC dual-slope ADC integrating ADC data-conversion IC integrated circuit differential input 12-bit resolution three-state output microprocessor bus UART zero-integrator phase over-range hangover 40-pin PDIP PDIP package through-hole package digital panel meter process monitoring temperature measurement sensor interface
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें