ICL7109CPL+2 - 12-Bit Dual-Slope ADC | Analog Devices
Référence : ICL7109CPL+2 ✓ ActifICL7109CPL+2 Présentation
An ADC is an integrated circuit that converts an analog voltage into a digital code. The ICL7109 belongs to the dual-slope integrating ADC category, a technique that uses fixed and integration periods to average input voltage over time. In the broader hierarchy, the ICL7109 is an ADC, then a data-conversion IC, then an integrated circuit used for electronic measurement and control.
The key features of the ICL7109CPL+2 include 12-bit resolution, one differential analog input, dual-slope conversion, three-state binary outputs, microprocessor-bus compatibility, and UART-oriented operation. Its outputs can be connected directly to a microprocessor bus, while the zero-integrator phase reduces over-range hangover, crosstalk, and hysteresis effects. These characteristics make one converter per channel practical when multiplexing a shared analog front end would otherwise add complexity.
The differential input architecture supports measurement of signals referenced to a midpoint or other common reference rather than ground alone. Low input bias current and low power consumption are useful in sensor-oriented systems, while the zero-integrator phase helps one channel recover promptly after an over-range condition. Designers should still observe the timing relationships among the conversion-control, busy, polarity, over-range, and output signals when connecting the device to a bus or UART.
Typical uses include digital panel instruments, temperature measurement systems, laboratory data loggers, industrial process monitors, and low-rate sensor interfaces. The ICL7109CPL+2 is especially suitable when a 12-bit result, tri-state bus control, and simple integration are more valuable than conversion speed. For battery-powered instruments, its low power consumption helps limit energy use, although external reference and source-impedance requirements still determine the achievable accuracy.
PCB implementation should preserve the pin assignments and analog layout of the manufacturer's 40-pin PDIP footprint. Keep the analog input path short, use suitable bypass capacitors at the supply pins, and route digital control and data outputs away from sensitive input nodes. Because this is a dual-slope converter, acquisition time and input settling must be coordinated with the conversion timing rather than optimized solely for instantaneous conversion latency.
This product overview combines the manufacturer product information with distributor technical listings, replacement cross-references, and practical guidance for evaluating the ICL7109CPL+2 in slow, precision-oriented data acquisition systems.
Alternatives de remplacement direct pour ICL7109CPL+2 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec ICL7109CPL+2 (même facteur de forme et même empreinte) — différant par Package, Resolution, Conversion Architecture.
ICL7109CPL+
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ICL7109CPL
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →TC7109CPL
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ICL7106SCPL
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →ICL7136CPL+
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →ICL7109CPL+2 Valeurs maximales et caractéristiques électriques
| Résolution | 12 bit |
| Conversion Architecture | Dual-slope |
| Analog Input Channels | 1 channel |
| Input Type | Differential |
| Digital Output | 12-bit binary with polarity and over-range outputs |
| Output Interface | 3-state binary parallel output |
| Tension d'alimentation | 5 V |
| Boîtier | 40-pin PDIP, 0.600 in (15.24 mm) width |
| Type de montage | Through-hole |
| Terminal Count | 40 terminals |
| Temperature Grade | Commercial |
| Zero-Integrator Phase | Yes |
| Over-Range Hangover Reduction | Yes |
| Microprocessor Interface | Direct microprocessor-bus compatible |
| UART Interface | Supported |
| Power Consumption | Low |
| Input Bias Current | Low |
Guide de configuration des broches du ICL7109CPL+2 40-pin pdip, 0.600 in (15.24 mm) width
Configuration des broches du ICL7109CPL+2 (boîtier 40-pin pdip, 0.600 in (15.24 mm) width). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour ICL7109CPL+2.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
ICL7109CPL+2 convient pour 6 applications: Digital Panel Meters, Temperature Measurement Systems, Industrial Process Monitors, Laboratory Data Loggers, Portable Environmental Instruments, Microprocessor-Based Metering.
Digital Panel Meters
The ICL7109CPL+2 fits digital panel meters because its 12-bit dual-slope conversion provides adequate resolution for many pressure, temperature, and level displays while keeping the signal path straightforward. The differential input can be arranged around a midpoint reference to suit the sensor front end, and the three-state binary outputs can drive a display controller through a controlled bus. The zero-integrator phase helps the converter recover promptly after an over-range input, reducing visible channel-transition errors in sequential measurements. Selection should focus on the required update rate, display refresh behavior, and reference accuracy rather than high-speed sampling performance.
Recommandé
Temperature Measurement Systems
The ICL7109CPL+2 is suitable for temperature measurement when the sensor produces a differential or midpoint-referenced analog voltage. Its 12-bit resolution supports a useful range of displayed temperature detail, while dual-slope conversion integrates the input over time and is well matched to relatively slow thermal signals. Low input bias current helps preserve the accuracy of high-impedance sensors, and low power consumption is advantageous in portable instruments. A stable voltage reference and carefully selected input network remain necessary because sensor gain, reference drift, and electrical noise can dominate the overall temperature error.
Recommandé
Industrial Process Monitors
The ICL7109CPL+2 can serve as the measurement core of an industrial process monitor for slow-changing variables such as tank level, pressure, flow proxies, or transducer output. The differential input allows the analog stage to reject common-mode disturbance, while the 12-bit code provides sufficient measurement granularity for many industrial readouts. The converter's low power use supports compact panel-mounted instruments, and the zero-integrator phase improves recovery after an over-range event. Designers should still provide input protection, filtering, reference conditioning, and isolation where the process environment requires it.
Recommandé
Laboratory Data Loggers
The ICL7109CPL+2 is useful in laboratory data loggers that sample slow analog channels rather than high-frequency waveforms. Its 12-bit resolution, low power consumption, and low input bias current support battery-powered or compact multi-channel instruments. The three-state outputs allow multiple converters to share bus-control logic when channel isolation is handled externally, while the differential input helps reject common-mode noise in longer sensor cables. Because dual-slope conversion has an integration interval, the logger must allow sufficient settling and acquisition time before reading the conversion-complete indication.
Recommandé
Portable Environmental Instruments
The ICL7109CPL+2 is appropriate for portable environmental instruments that monitor battery-powered sensors and require a readable numeric result rather than waveform capture. Its low-power operating behavior helps extend runtime, while the 12-bit dual-slope ADC can measure temperature, humidity, gas, or pressure outputs after appropriate signal conditioning. The differential input supports sensors centered around a reference or bridge excitation, provided the selected reference and input levels stay within the converter's electrical limits. Mechanical protection, moisture-resistant construction, and stable sensor excitation are typically more important to field accuracy than additional converter speed.
Recommandé
Microprocessor-Based Metering
The ICL7109CPL+2 can connect directly to a microprocessor bus because it provides 12-bit binary, polarity, over-range, and three-state output signals. This arrangement suits metering equipment in which the host controller performs calibration, display formatting, alarms, and communication. The converter's differential input reduces the need for a ground-referenced input stage when the sensor signal is centered, while its low power use limits system overhead. The interface design must respect the converter's busy and control timing and account for the acquisition interval required by its dual-slope conversion process.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ICL7109CPL+2 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ICL7109CPL+ | ICL7109CPL | TC7109CPL | ICL7106SCPL | ICL7136CPL |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Microchip Technology | Analog Devices | Analog Devices |
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Resolution | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit |
| Conversion Architecture | Dual-slope | Dual-slope | Dual-slope | Dual-slope | Dual-slope | Dual-slope |
Principaux différenciateurs
- Maintains the established ICL7109 conversion and bus behavior (vs TC7109CPL)
- Uses the same 40-pin PDIP footprint as closely related ICL7109 variants (vs ICL7109CPL)
- Differential input supports common-mode rejection (vs ICL7106SCPL)
- Zero-integrator phase improves recovery after overload (vs ICL7136CPL)
Notes de conception
Route the differential input and reference connections away from the switching or high-current return paths of the surrounding circuit. Place the input-network and reference-bypass components close to their associated pins, and keep the analog ground path compact. Although the ICL7109CPL+2 is a through-hole PDIP device, careful analog layout remains necessary because long input tracks can pick up noise that appears directly in the 12-bit conversion result.
Coordinate conversion control, busy status, and data acquisition so that the input has settled before the integration interval begins. A dual-slope converter averages for a defined period, but it cannot correct a source that has already charged or discharged an external capacitor incorrectly. Review the input impedance, acquisition interval, reference stability, and polarity handling in the manufacturer datasheet before setting the measurement timing.
Do not treat a 40-pin PDIP outline as proof of drop-in compatibility. Verify analog input polarity, reference connections, control polarity, output encoding, and the meaning of the polarity and over-range signals for each candidate. A substitution also requires checking supply limits and temperature grade. For legacy production boards, retain the original ICL7109 when any of these functions cannot be proven equivalent.
Decouple the supply pins close to the package using the capacitance and ESR characteristics specified by the Analog Devices datasheet. Keep the analog supply return path distinct from noisy digital currents where the board architecture permits it. A stable low-noise reference is as important as supply regulation because reference error directly limits the accuracy of the 12-bit result.
Informations de conformité
The commercial-grade legacy ICL7109 product is not identified as an automotive-qualified AEC-Q100 device. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation from the manufacturer or current material declaration.