Texas Instruments

INA131AP-1 - Precision Gain-100 Instrumentation Amplifier | TI

MPN: INA131AP-1 ✓ सक्रिय
50 uV maximum Vdss 2 nA maximum Id 8-pin PDIP Package
न्यूनतम ऑर्डर मात्रा: 1 |

INA131AP-1 अवलोकन

The Texas Instruments INA131AP-1 is a precision instrumentation amplifier with a fixed gain of 100, low input offset voltage of 50 uV maximum, input bias current of 2 nA maximum, and common-mode rejection of 110 dB minimum, housed in an 8-pin PDIP package. It is designed to amplify low-level differential signals while rejecting common-mode interference.

An instrumentation amplifier is a specialized amplifier that combines differential input handling, high input impedance, accurate gain setting, and strong common-mode rejection into one device. Within the signal-chain hierarchy, it belongs to the amplifier IC family and supports precision measurement, sensor conditioning, and industrial interface systems. Unlike a general-purpose operational amplifier, the INA131AP-1 provides a defined internal gain of 100 and is intended for applications where common-mode noise can overwhelm a small differential measurement.

The INA131AP-1 offers 0.25 uV/°C maximum input offset voltage drift and input overvoltage protection to ±40 V. These characteristics make it suitable for low-level sensor outputs, bridge transducers, current-shunt measurements, and analog front ends where offset and drift affect measurement accuracy. Its 8-pin PDIP package also supports conventional through-hole assembly and prototype boards.

The device uses a three-op-amp instrumentation-amplifier architecture with an internal gain of 100. This architecture provides differential inputs, high input impedance, and balanced amplification while limiting the effect of common-mode voltage. The maximum input bias current of 2 nA is especially relevant when measuring sources with high source impedance, while the 110 dB minimum common-mode rejection helps preserve signal integrity in noisy industrial environments.

Typical uses include bridge-based pressure and load-cell interfaces, current-shunt monitoring in power systems, precision instrumentation, medical equipment, industrial sensor acquisition, and low-level analog signal conditioning. For a 10 mV differential input, the nominal gain of 100 produces an output of 1 V, allowing millivolt-level sensor signals to be measured with standard analog-to-converter input ranges.

Design the input network to limit differential input voltage, maintain source impedance balance, and avoid excessive input bias-current errors. Because the gain is fixed internally, external gain resistors are unnecessary, but the input pins still require careful protection and layout. Check the complete common-mode and output-swing limits against the actual supply voltages rather than relying only on the ±18 V maximum supply rating.

This page combines manufacturer specifications, practical application guidance, comparison parameters, and verified component links. It is designed to help engineers select the part, plan the analog front end, and identify candidate replacements without duplicating the complete manufacturer datasheet.

के लिए ड्रॉप-इन विकल्प INA131AP-1 — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

इस सीरीज़ के वेरिएंट

समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं INA131AP-1 (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Input Bias Current, Package, Amplifier Type, Architecture, Common-Mode Rejection Ratio.

Texas Instruments
Amplifier Type: Precision fixed-gain instrumentation amplifier
Common-Mode Rejection Ratio: 106 dB
इसके साथ तुलना करें INA131AP-1 →
Texas Instruments
Amplifier Type: Precision instrumentation amplifier
इसके साथ तुलना करें INA131AP-1 →
Texas Instruments
Input Bias Current: 5 nA maximum
Package: 8-pin plastic DIP
Architecture: Three-op-amp instrumentation amplifier
इसके साथ तुलना करें INA131AP-1 →

INA131AP

✅ ड्रॉप-इन
Texas Instruments
📦 8-PDIP
Precision fixed-gain instrumentation amplifier · 1 circuit · 100 V/V · 70 kHz · 0.7 V/µs · 125 µV maximum · 0.25 µV/°C maximum

कीमत के लिए संपर्क करें

डेटाशीट देखें →

INA131BP

✅ ड्रॉप-इन
Texas Instruments
📦 8-PDIP
Precision instrumentation amplifier · 3 amplifiers · 100 V/V · Fixed gain · 2.25 V to 18 V · 50 V · 70 kHz · 0.7 V/µs

कीमत के लिए संपर्क करें

डेटाशीट देखें →

INA131AP-1 Maximum Ratings और Electrical Characteristics

Product Type Precision instrumentation amplifier
Number of Circuits 1 circuit
Internal Gain 100 V/V
Architecture 3-op-amp instrumentation amplifier
Input Offset Voltage 50 uV maximum
Input Offset Voltage Drift 0.25 uV/°C maximum
Input Bias Current 2 nA maximum
Common-Mode Rejection Ratio 110 dB minimum
Input Overvoltage Protection ±40 V
Maximum Supply Voltage ±18 V
Total Supply Voltage 36 V maximum
Number of Inputs 2 differential inputs
आउटपुट की संख्या 1 output
पैकेज 8-pin PDIP
माउंटिंग प्रकार Through-hole

INA131AP-1 पिन कॉन्फ़िगरेशन

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
पिन 1 RG- — Gain-setting terminal
पिन 2 IN- — Inverting input
पिन 3 IN+ — Noninverting input
पिन 4 V- — Negative supply connection
पिन 5 RG+ — Gain-setting terminal
पिन 6 OUT — Amplified output
पिन 7 V+ — Positive supply connection
पिन 8 RG — Gain-setting terminal

सामान्य अनुप्रयोग

INA131AP-1 के लिए उपयुक्त है 6 अनुप्रयोगs: Load-Cell and Pressure-Sensor Front Ends, Current-Shunt Monitoring, Precision Industrial Sensor Acquisition, Low-Level Analog Signal Conditioning, Medical and Laboratory Measurement, Balanced Bridge and Differential Sensing.

🏭

Load-Cell and Pressure-Sensor Front Ends

The INA131AP-1 fits low-level bridge measurements because its fixed gain of 100 multiplies a 10 mV differential output to approximately 1 V, while its 110 dB minimum common-mode rejection reduces interference coupled into both sensor inputs. Its 50 uV maximum input offset and 0.25 uV/°C maximum drift help preserve measurement stability over temperature. Place the device close to the bridge and keep the two input paths balanced to minimize thermal gradients and parasitic imbalance. Confirm that bridge excitation, common-mode voltage, and output swing remain within the limits published for the INA131 family before beginning layout.

⚡

Current-Shunt Monitoring

INA131AP-1 is appropriate for measuring the small voltage developed across a current shunt when the available analog range is limited. The fixed gain of 100 raises a 10 mV shunt signal to roughly 1 V, while low input bias current of 2 nA limits the disturbance introduced by high-impedance source paths. The 110 dB minimum common-mode rejection is useful when the shunt signal sits on a substantial DC voltage. For best results, use a Kelvin connection to the shunt, keep the two signal traces together, and verify that common-mode and output limits are satisfied over the full current range.

📟

Precision Industrial Sensor Acquisition

The INA131AP-1 supports industrial acquisition circuits that must distinguish small differential sensor outputs from common-mode noise. Its 100 V/V gain, 50 uV maximum offset voltage, and 110 dB minimum common-mode rejection provide useful signal conditioning ahead of an analog-to-converter. Input bias current of 2 nA is suitable for many high-impedance transducers, although source-imbalance errors still require attention. A practical design should place the amplifier near the sensor connector, route the differential pair as a tightly coupled pair, and include protection that does not compromise normal input impedance or common-mode headroom.

📡

Low-Level Analog Signal Conditioning

INA131AP-1 can condition millivolt-level differential signals before further amplification or digitization because its internal gain of 100 removes the need for an external gain network. A 10 mV input becomes approximately 1 V at the output, making the device useful when an ADC cannot accept the original signal directly. The three-op-amp architecture supports differential measurement, while low offset and drift reduce errors that would otherwise be amplified together with the signal. Confirm output headroom, input range, and settling behavior in the manufacturer datasheet, and avoid operating the output near its saturation limits.

🩺

Medical and Laboratory Measurement

The INA131AP-1 is suitable for laboratory and medical-instrument signal paths when the required gain is 100 and low offset is important. The 50 uV maximum input offset and 0.25 uV/°C maximum drift help maintain accuracy as temperature changes, while the 110 dB minimum common-mode rejection assists with signals referenced to a nonzero common-mode voltage. Its 8-pin PDIP format is convenient for through-hole prototypes and education platforms. Production medical designs still require application-specific safety, isolation, input-protection, and validation work; the component qualification does not by itself establish compliance for a finished medical system.

🧩

Balanced Bridge and Differential Sensing

INA131AP-1 is a natural choice for balanced differential sensing because it is optimized around a gain of 100 and provides 110 dB minimum common-mode rejection. These characteristics help preserve small differential signals when both inputs experience a common disturbance from nearby switching circuits or long cable runs. The low 2 nA maximum input bias current helps when sensor outputs have appreciable impedance, although matched impedances remain important. Use shielded or twisted differential routing, maintain symmetry between input paths, and confirm that the selected power supplies provide sufficient output swing for the required bridge and sensor range.

अनुशंसित उत्पादों का सारांश

INA131AP Texas Instruments उपयोग में: Load-Cell and Pressure-Sensor Front Ends, Current-Shunt Monitoring, Precision Industrial Sensor Acquisition, Low-Level Analog Signal Conditioning, Medical and Laboratory Measurement, Balanced Bridge and Differential Sensing INA121PG4 Instrumentation-amplifier family referenced for comparison उपयोग में: Load-Cell and Pressure-Sensor Front Ends, Precision Industrial Sensor Acquisition, Medical and Laboratory Measurement INA111BPG4 DIP-8 instrumentation amplifier referenced for comparison उपयोग में: Current-Shunt Monitoring, Balanced Bridge and Differential Sensing INA131BP Texas Instruments उपयोग में: Low-Level Analog Signal Conditioning
What are the key specifications of INA131AP-1 that engineers should know?
The INA131AP-1 is a precision instrumentation amplifier with a fixed gain of 100, 50 uV maximum input offset voltage, 2 nA maximum input bias current, and 110 dB minimum common-mode rejection. According to the Texas Instruments INA131 datasheet, the device also offers 0.25 uV/°C maximum offset drift, ±40 V input overvoltage protection, operation from up to ±18 V, and an 8-pin PDIP package. These figures make it most useful for millivolt-level differential measurements where offset, drift, and common-mode rejection strongly affect result accuracy.
What is the operating voltage of INA131AP-1?
The INA131AP-1 supports supply voltages of up to ±18 V, corresponding to 36 V total. According to the Texas Instruments INA131 datasheet, the permitted common-mode and output ranges must also be respected when selecting the supply. The device is intended for bipolar analog systems as well as suitable single-supply arrangements, subject to the input and output operating limits described in the manufacturer datasheet. Confirm those limits before using the amplifier near either supply rail.
What is the gain of INA131AP-1?
The INA131AP-1 has a fixed internal gain of 100 V/V. According to the Texas Instruments INA131 datasheet, a differential input of 10 mV therefore produces a nominal 1 V output before accounting for offset, gain error, and output headroom. The fixed gain removes the need for an external gain-setting resistor network, making the part suitable for fixed-range bridge, shunt, and low-level sensor measurements where a consistent gain of 100 is desired.
Where can I download the INA131AP-1 datasheet PDF?
The official INA131AP-1 datasheet PDF is available through Texas Instruments at https://www.ti.com/lit/ds/symlink/ina131.pdf. The document is titled “Precision G = 100 Instrumentation Amplifier” and covers the INA131 family, including electrical characteristics, pin configuration, typical performance, and application information. Use the pin-description table and ordering information within the manufacturer document to confirm the INA131AP-1 suffix, package, and operating-temperature designation.
Where can I find the INA131AP-1 pinout?
The INA131AP-1 pinout is presented in the pin-configuration section of the Texas Instruments INA131 datasheet. The device uses an 8-pin PDIP arrangement with the two differential inputs, two supply pins, output, reference connection, and gain-setting pins identified on the package diagram. Follow the numbered package drawing when laying out the PCB because the INA131 family uses conventional counter-clockwise numbering around the DIP body. Confirm signal names against the datasheet before assigning tracks.
How does INA131AP-1 compare with INA131AP?
The INA131AP-1 and INA131AP belong to the same Texas Instruments INA131 family and use the same 8-pin PDIP package. Both provide a fixed gain of 100 and the principal precision specifications shown for the INA131 family. Their suffix and temperature-grade treatment must be confirmed from the ordering table before treating one as a substitution. For an existing INA131AP-1 design, verify the required temperature range and the manufacturer ordering information for the replacement suffix.
Is INA131AP-1 suitable for bridge sensor measurements?
Yes, INA131AP-1 is suitable for bridge sensor measurements when the output range and common-mode voltage remain inside its operating limits. Its fixed gain of 100, 50 uV maximum offset voltage, and 110 dB minimum common-mode rejection are valuable for low-level bridge outputs. According to the Texas Instruments INA131 datasheet, the internal three-op-amp architecture also provides differential input handling. Bridge excitation, output saturation, and input common-mode limits still require calculation for each particular bridge and supply configuration.
When should I choose INA131AP-1 over a lower-gain instrumentation amplifier?
Choose INA131AP-1 when the required differential gain is approximately 100 and the measurement benefits from its low 50 uV maximum input offset. A lower-gain instrument amplifier may be preferable when a wider output range, adjustable gain, or lower gain error is more important than fixed gain. According to the Texas Instruments INA131 datasheet, the INA131AP-1 provides a 0.25 uV/°C maximum offset drift, making it especially useful when stability across temperature matters as well as low initial offset.
What can replace INA131AP-1?
The closest same-family drop-in candidate identified for the INA131AP-1 is the INA131AP, which uses the same 8-pin PDIP package and retains the fixed gain of 100. Before replacing the device, confirm input offset voltage, offset drift, bias current, common-mode rejection, supply range, and temperature grade against the design requirements. The INA131BP may also share the family package, but its ordering suffix and exact electrical grade should be verified in the manufacturer ordering table before use.
Is INA131AP-1 the same as INA131AP?
The INA131AP-1 is closely related to the INA131AP and uses the same 8-pin PDIP package with a fixed gain of 100. They should not be assumed identical without checking the suffix-specific ordering information and temperature requirements. According to the Texas Instruments INA131 datasheet, ordering information identifies separate device suffixes under the same product family. A replacement is suitable only when its electrical limits, qualification, and environmental grade satisfy the original design.
What is the best Texas Instruments equivalent for INA131AP-1?
The best verified same-family starting point is the INA131AP because it uses the same 8-pin PDIP package and fixed gain of 100. The INA131BP is another family member that can be evaluated for the same footprint, subject to suffix-specific verification. According to the Texas Instruments INA131 datasheet, package compatibility alone does not establish interchangeability. Compare offset voltage, drift, bias current, CMRR, input protection, supply range, and operating-temperature grade before approving either candidate.
Where can I buy INA131AP-1 and check current lead time?
Use the Request a Quote form on this page to request INA131AP-1 pricing, current availability, minimum order quantity, and lead time. The component is listed as an 8-PDIP instrumentation amplifier from the Texas Instruments INA131 family, and its ordering code is INA131AP-1. For a production commitment, request a written response that identifies the package, temperature grade, quantity, and delivery schedule before releasing the purchase order.
Is INA131AP-1 in stock?
Current INA131AP-1 stock should be confirmed through the Request a Quote form on this page. The form can provide a quantity-specific availability response for the exact INA131AP-1 ordering code and the required 8-pin PDIP package. Do not infer production availability from a generic family listing, because package suffix, grade, quantity, and delivery schedule can differ between order configurations.
How much does INA131AP-1 cost?
Use the Request a Quote form on this page for a current INA131AP-1 quotation. The quote should state the quantity, unit price, currency, packaging, and expected lead time for the exact INA131AP-1 ordering code. This approach avoids presenting a stale or generic family price as a firm offer and allows the quotation to reflect the quantity and delivery requirements of the intended build.
How should I protect the inputs of INA131AP-1?
Keep the differential input voltage and common-mode voltage within the limits published by Texas Instruments for the INA131 family. The manufacturer identifies input overvoltage protection to ±40 V, but that protection rating should not be treated as permission for unrestricted continuous overload. According to the Texas Instruments INA131 datasheet, input protection and supply limits must be respected. Use series resistance, suitable clamping, and a correctly scaled bridge or shunt network where fault conditions can exceed normal signals.
Does INA131AP-1 need an external gain resistor?
No external gain-setting resistor is required for the fixed gain of 100 in the INA131AP-1. According to the Texas Instruments INA131 datasheet, the INA131 is a precision instrumentation amplifier with an internal gain of 100. The gain-setting pins shown in the package data should be handled according to the manufacturer pin-description table rather than treated as conventional adjustable-gain inputs. External resistance is still needed if the design requires input balancing, filtering, current limiting, or fault protection.

के लिए इंजीनियरिंग संदर्भ डेटा INA131AP-1 — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose INA131AP-1 when the design needs a fixed gain of 100, low input offset, low drift, and strong common-mode rejection in an 8-pin PDIP footprint. It is particularly suitable for bridge sensors, current shunts, and low-level differential measurement circuits. INA131AP is the closest same-family candidate when its suffix-specific temperature grade and qualification satisfy the production requirements; both retain the same gain and package. INA131BP can be evaluated on the same footprint when its ordering details and electrical limits meet the original design. Do not substitute general-purpose op amps or differently configured instrumentation amplifiers solely because they use an 8-pin package. Their pin functions, gain-setting method, common-mode range, and internal architecture may differ. For any replacement, verify offset voltage, drift, bias current, CMRR, input protection, supply range, output swing, operating temperature, and lifecycle requirements against the manufacturer datasheet.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद INA131AP INA131BP
Package 8-PDIP 8-PDIP - same 8-PDIP - same
Brand Texas Instruments Texas Instruments Texas Instruments
Product Type Precision instrumentation amplifier Precision instrumentation amplifier Precision instrumentation amplifier
Internal Gain 100 V/V 100 V/V 100 V/V
Architecture 3-op-amp instrumentation amplifier 3-op-amp instrumentation amplifier 3-op-amp instrumentation amplifier
Number of Circuits 1 circuit 1 circuit 1 circuit

मुख्य विशेषताएँ

  • Fixed precision gain (बनामINA131AP)
  • Low input offset for small-signal measurement (बनामINA131AP)
  • High common-mode rejection (बनामINA131BP)

डिज़ाइन नोट्स

Route IN+ and IN- as a tightly coupled differential pair, keep both paths over a continuous ground plane, and minimize the distance between the sensor connector and the amplifier. Avoid sharing a return path with high-current switching nodes. Small source-imbalance errors can create differential current and offset, so use equal input impedances and avoid asymmetrical test points, long stubs, and unnecessary series components.

Check the complete input common-mode range and output-voltage range at the actual supply voltage before selecting the power rails. The maximum supply rating is ±18 V, but adequate output headroom is still required when the output approaches a rail. Place a low-noise bypass capacitor close to each supply pin and keep its return path short. Confirm the capacitor voltage rating and effective capacitance at the intended temperature and bias.

Do not assume the ±40 V input overvoltage rating permits unrestricted continuous operation. Verify differential and common-mode limits, confirm whether protection is active only under specified conditions, and use external limiting when fault voltages can exceed the published ratings. Also avoid driving the output into saturation: once clipping occurs, the input offset and recovery behavior can no longer be treated as the normal specified performance.

For cable-connected sensors, use a differential or twisted pair and place suitable input filtering close to the amplifier. Locate protection components where they will not introduce unequal impedance or capacitance between IN+ and IN-. The 110 dB minimum common-mode rejection does not remove the need for balanced routing; mismatched geometry, connectors, and component tolerances can convert common-mode disturbance into differential error before it reaches the amplifier.

अनुपालन जानकारी

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

No specific environmental or automotive qualification status was established for this ordering code. Confirm RoHS, REACH, lead-free, halogen-free, and conflict-minerals status for the exact INA131AP-1 package and manufacturing configuration before release.

डेटा सत्यापन तिथि: 2026-11-09 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

ina131ap datasheet INA131AP-1 datasheet INA131AP-1 datasheet pdf INA131AP-1 pinout INA131AP-1 specifications INA131AP-1 instrumentation amplifier INA131AP-1 8-PDIP Texas Instruments INA131AP-1 INA131AP-1 gain 100 INA131AP-1 drop-in replacement INA131AP-1 vs INA131AP INA131AP-1 price INA131AP-1 stock INA131AP-1 bridge sensor application INA131AP-1 input offset voltage

संबंधित कंपोनेंट्स और शब्द

Texas Instruments INA131AP-1 INA131AP INA131BP INA121PG4 INA111BPG4 precision instrumentation amplifier instrumentation amplifier amplifier IC semiconductor differential input common-mode rejection ratio CMRR input offset voltage input bias current input overvoltage protection three-op-amp architecture 8-PDIP DIP-8 through-hole package surface-mount sibling load-cell measurement current-shunt monitoring industrial sensor acquisition RoHS REACH AEC-Q100
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें