KSZ8051MLL-TR - 100M Ethernet PHY with MII | Microchip
MPN: KSZ8051MLL-TR ✗ जीवन की समाप्तिKSZ8051MLL-TR अवलोकन
An Ethernet physical-layer transceiver, or Ethernet PHY, is the circuit that converts digital Ethernet data into signals suitable for transmission over twisted-pair cabling and converts received analog signals back into digital data for the MAC. The KSZ8051 belongs to the interface-IC hierarchy: Ethernet PHY → Ethernet transceiver → physical-layer transceiver → semiconductor. Its MII interface connects directly to an Ethernet MAC while the analog PHY side connects to an RJ45 magnetics or network connector section.
Key features include support for both 10 Mb/s and 100 Mb/s Ethernet rates, full MII support, single-supply 3.3 V operation, and AEC-Q100 qualification. The 48-LQFP surface-mount package provides a defined lead arrangement and exposed routing space for power, ground, data, control, and analog network connections. These characteristics make the device suitable for automotive Ethernet nodes, industrial control equipment, embedded gateways, and industrial network switches.
The KSZ8051 is a highly integrated PHY solution intended to reduce board cost and simplify PCB layout. A 3.3 V-only system architecture eliminates the need for a separate 5 V transceiver rail. The full MII interface provides a conventional parallel connection to an Ethernet controller, allowing the PHY to support legacy 10/100 Ethernet designs without introducing a proprietary serial interface.
Typical applications include 100BASE-TX vehicle-network gateways, industrial Ethernet controllers, embedded communication modules, network-interface adapters, and factory automation equipment. Automotive deployments benefit from the manufacturer’s AEC-Q100 qualification, while industrial designs can use the same PHY for equipment operating near 10BASE-T or 100BASE-TX networks.
The principal design task is preserving signal integrity from the PHY through the magnetics and connector while providing a low-impedance 3.3 V plane across the LQFP leads. Place input and output decoupling capacitors close to their associated power pins, route the MII clock and data signals as matched-length groups, and maintain continuous ground-plane return paths beneath and between the PHY and network-interface circuitry.
This page combines the manufacturer’s device classification, package information, automotive qualification status, sourcing lifecycle information, and practical PCB guidance with clearly qualified drop-in replacement analysis. It distinguishes electrically and mechanically interchangeable options from related Ethernet PHYs that require redesign.
के लिए ड्रॉप-इन विकल्प KSZ8051MLL-TR — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
KSZ8051MLLI-TR
✅ ड्रॉप-इन📋 संदर्भ विकल्प (कैटलॉग में नहीं)
KSZ8051MLL-TR विशेषताएं
| Product Type | 10BASE-T/100BASE-TX Ethernet physical-layer transceiver |
| सप्लाई वोल्टेज | 3.3 V |
| Supported Ethernet Rates | 10 Mb/s and 100 Mb/s |
| MAC Interface | Full MII |
| Transceiver Count | 1 transceiver |
| पैकेज | 48-LQFP (7 mm x 7 mm) |
| माउंटिंग प्रकार | Surface mount |
| Automotive Qualification | AEC-Q100 standard qualified |
| Cable Support | CAT-5 unshielded twisted pair |
| Supply Type | Single supply |
| Maximum Data Rate | 100 Mb/s |
KSZ8051MLL-TR 48-lqfp (7 mm x 7 mm) पिन कॉन्फ़िगरेशन गाइड
KSZ8051MLL-TR (48-lqfp (7 mm x 7 mm) पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: KSZ8051MLL-TR.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
KSZ8051MLL-TR के लिए उपयुक्त है 6 अनुप्रयोगs: Automotive Ethernet Gateway, Industrial Ethernet Controller, Embedded Network Interface Adapter, Factory Automation Sensor Gateway, Network Management Interface, Legacy Test and Measurement Ethernet Port.
Automotive Ethernet Gateway
The KSZ8051MLL-TR fits an automotive Ethernet gateway because it combines a 3.3 V single supply, 10BASE-T/100BASE-TX operation, full MII support, and AEC-Q100 standard qualification in one 48-LQFP device. It can sit between a legacy parallel-interface Ethernet controller and the vehicle’s twisted-pair network. Keeping the PHY interface at 100 Mb/s makes it appropriate for lower-bandwidth vehicle domains, diagnostics, or service connections where full-speed Ethernet is unnecessary. The 7 mm by 7 mm package supports compact controller boards, although the external magnetics and connector can dominate board area. Confirm temperature range, transient requirements, and qualification details for the specific vehicle platform before release.
अनुशंसित
Industrial Ethernet Controller
The KSZ8051MLL-TR is suitable for an industrial 10/100 Ethernet controller that uses a conventional MII interface and runs from 3.3 V. The PHY provides the physical-layer connection to CAT-5 unshielded twisted-pair cabling while the host processor or dedicated MAC handles higher-layer traffic. A single 3.3 V rail simplifies power sequencing in control cabinets where space and component count are constrained. The principal design consideration is signal integrity between the 48-LQFP device, network magnetics, and connector; keep the analog network section away from noisy switching nodes and provide local supply decoupling. Industrial temperature, isolation, and EMC requirements must be checked against the complete system specification.
अनुशंसित
Embedded Network Interface Adapter
The KSZ8051MLL-TR can serve as the 10/100 Ethernet physical layer in an embedded network-interface adapter driven by an MII-capable controller. Its single 3.3 V operation avoids a separate 5 V transceiver rail, while the full MII interface gives the controller access to conventional transmit, receive, carrier-sense, and collision-related signaling. At the network side, the PHY interfaces with magnetics and an RJ45 section to form a complete twisted-pair connection. Designers should reserve continuous ground area, minimize the supply loop, and verify MII timing against the MAC clock. Its 100 Mb/s ceiling makes it appropriate for management, control, telemetry, and legacy embedded networks rather than bandwidth-heavy multimedia transfer.
अनुशंसित
Factory Automation Sensor Gateway
The KSZ8051MLL-TR can connect a factory sensor or PLC gateway to a 10BASE-T or 100BASE-TX network when the host controller retains an MII interface. Supporting both rates allows the same PHY architecture to communicate with older 10 Mb/s equipment and faster 100 Mb/s infrastructure. The 3.3 V single-supply characteristic is useful for compact control boards with constrained power budgets, and the 48-LQFP footprint permits compact placement beside the processor. For reliable operation, isolate Ethernet routing from motor-control and relay-switching nodes, use a solid ground plane, and place bypass capacitors at the supply pins. Environmental immunity and sustained operating temperature should be validated for the machine’s installed location.
अनुशंसित
Network Management Interface
The KSZ8051MLL-TR is a practical choice for a dedicated network-management interface that requires legacy 10/100 Ethernet rather than gigabit throughput. A management processor with an MII controller can use the PHY to connect to switches, routers, or industrial infrastructure without implementing a complex multi-gigabit PHY interface. Operation from one 3.3 V rail simplifies auxiliary low-power circuitry, while full MII support gives the controller direct access to standard Ethernet framing and status signals. The 48-LQFP package keeps the PHY compact but requires disciplined pin assignment and layout. Verify the controller’s supported MII clock mode and timing, and check the complete interface’s EMC performance when it will be exposed through an external cable and connector.
अनुशंसित
Legacy Test and Measurement Ethernet Port
The KSZ8051MLL-TR can provide a 10/100 network connection for legacy test and measurement equipment whose controller supports the MII interface. This is especially relevant when retaining an established measurement instrument platform while updating its communications subsystem rather than replacing the entire processor architecture. The PHY supports 10 and 100 Mb/s operation from 3.3 V, allowing connection to laboratory computers and common Ethernet infrastructure. Because measurement systems can combine sensitive analog circuitry with switching converters, the Ethernet section should have a controlled ground reference and separated return paths. Confirm signal-integrity margins, isolation requirements, and the applicable environmental range before integrating the 48-LQFP device into a new enclosure.
अनुशंसित
अनुशंसित उत्पादों का सारांश
के लिए इंजीनियरिंग संदर्भ डेटा KSZ8051MLL-TR — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद | KSZ8051MLLI-TR |
|---|---|---|
| Brand | Microchip Technology | Microchip Technology |
| Package | 48-LQFP (7 mm x 7 mm) | 48-LQFP (7 mm x 7 mm) |
| Product Type | 10BASE-T/100BASE-TX Ethernet PHY transceiver | 10BASE-T/100BASE-TX Ethernet PHY transceiver |
| Supply Voltage | 3.3 V | 3.3 V |
| Supported Data Rates | 10 Mb/s and 100 Mb/s | 10 Mb/s and 100 Mb/s |
| MAC Interface | Full MII | Full MII |
| Delivery Format | Tape and reel (-TR) | Tape and reel (-TR) |
मुख्य विशेषताएँ
- Exact same-family 48-LQFP replacement route (बनामKSZ8051MLLI-TR)
- AEC-Q100 qualification for automotive designs (बनामKSZ8051MLLI-TR)
- Legacy full-MII compatibility (बनामKSZ8051MLLI-TR)
डिज़ाइन नोट्स
Route the 3.3 V supply and ground connections directly to the 48-LQFP with short, low-impedance paths, and place the manufacturer-recommended bypass capacitors adjacent to the corresponding leads. Avoid sharing narrow supply traces between the PHY and unrelated digital loads. A continuous ground plane beneath the device gives the MII and analog-network pins a low-inductance return path, reducing susceptibility to switching noise and Ethernet common-mode disturbances.
Keep the MII clock and associated data traces together as a controlled group, use the MAC’s specified clock mode, and avoid unnecessary test pads or long branch stubs on timing-sensitive nets. Match trace lengths where the Ethernet controller and PHY documentation requires it. Preserve a continuous reference plane below the group so that the MII signals retain predictable impedance and edge behavior at the controller-to-PHY boundary.
Separate the PHY’s analog network-side routing from switching-regulator loops, high-current relays, and other noisy digital returns. Route the connection toward the network magnetics with short, controlled paths and avoid copper structures that interrupt the intended return current. Keep the RJ45 and magnetics section away from sensitive sensor or measurement circuitry because cable-borne transients and common-mode currents can couple directly into the PHY’s analog pins.
अनुपालन जानकारी