Analog Devices

MAX14806CCM+T - 16-Channel 200V Ultrasound Switch | Analog Devices

MPN: MAX14806CCM+T ✓ सक्रिय
200 V Vdss 16 ohm Rds(on) 48-LQFP, 7 mm x 7 mm Package
न्यूनतम ऑर्डर मात्रा: 1 |

MAX14806CCM+T अवलोकन

Analog Devices MAX14806CCM+T is a 16-channel high-voltage analog switch IC built for ultrasound imaging and piezoelectric probe circuits. It provides two independently controlled banks of eight SPST switches, uses 200 V process technology, and includes integrated 40 kΩ bleed resistors on each switch terminal. The device is packaged in a 48-LQFP measuring 7 mm by 7 mm and operates from a 2.7 V to 5.5 V logic supply.

A high-voltage analog switch is an integrated semiconductor device that routes high-voltage analog signals while isolating sensitive receiver or transmitter circuits when a channel is not selected. Within the signal-chain hierarchy, the MAX14806 belongs to the analog switch family, interface IC category, and broader semiconductor category. Its primary role in an ultrasound probe is selecting groups of piezoelectric elements without introducing excessive charge injection or allowing residual voltage to accumulate.

The MAX14806CCM+T offers 16 SPST channels arranged as two banks of eight. Each terminal includes a 40 kΩ bleed resistor that helps reduce voltage buildup in capacitive loads such as piezoelectric elements. Digital controls DIN1 and DIN2 select the two eight-channel banks, while the 200 V switch process supports high-voltage analog signal routing. The specified extended operating range of -40°C to +85°C suits industrial and medical imaging equipment with controlled ambient conditions.

Internally, the switch architecture uses separate high-voltage channels with integrated discharge paths. The bleed resistors provide a defined leakage route after deselection, which is particularly valuable when connecting capacitive transducers that can otherwise retain charge between transmit and receive cycles. Because switched nodes can develop substantial voltage, PCB creepage, clearance, exposed-pad treatment, and high-voltage routing require careful implementation.

Typical uses include bank selection in biplane and triplane ultrasound probes, replacement of discrete high-voltage relays, and switching networks for piezoelectric imaging arrays. The 48-terminal surface-mount package supports compact probe electronics, while the integrated bleed resistors reduce the external component count needed for charge management.

Designers should verify that every high-voltage trace has adequate spacing, avoid placing sensitive receiver paths beneath or beside switched nodes, and use the manufacturer pin-description table when assigning PCB connections. The digital interface operates from 2.7 V to 5.5 V, but control signals must not be treated as high-voltage lines because the 200 V rating applies to the switched analog nodes.

This product page consolidates the device architecture, verified electrical attributes, package information, application guidance, and the documented Supertex HV2731 drop-in relationship into an engineering-oriented reference for ultrasound probe and high-voltage switching designs.

के लिए ड्रॉप-इन विकल्प MAX14806CCM+T — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

HV2731

✅ ड्रॉप-इन
📦 48-pin TQFP
Drop-in replacement identified by Analog Devices; both use 48-pin TQFP packages and are specified from -40°C to +85°C, while detailed HV2731 ratings require separate verification.

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

MAX14806CCM+T Maximum Ratings और Electrical Characteristics

Number of Channels 16 channels
Switch Configuration 2 banks of 8 SPST switches
High-Voltage Process 200 V
On Resistance 16 ohm
Bleed Resistance 40 kOhm per switch terminal
Logic Supply Voltage Range 2.7 V to 5.5 V
ऑपरेटिंग तापमान रेंज -40°C to +85°C
पैकेज 48-LQFP, 7 mm x 7 mm
Terminal Count 48 terminals
Package Type QFP, square surface-mount package
माउंटिंग प्रकार Surface mount
Temperature Grade Industrial
Digital Control Inputs 2 inputs: DIN1 and DIN2
Lead-Free Status Lead free
RoHS स्थिति RoHS compliant
Primary Application High-voltage switching for ultrasonic imaging

MAX14806CCM+T qfp, square surface-mount package पिन कॉन्फ़िगरेशन गाइड

MAX14806CCM+T (qfp, square surface-mount package पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।

MAX14806CCM+T के लिए qfp, square surface-mount package पैकेज पिनआउट आरेख

इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: MAX14806CCM+T.

देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।

सामान्य अनुप्रयोग

MAX14806CCM+T के लिए उपयुक्त है 6 अनुप्रयोगs: Biplane Ultrasound Probe Bank Selection, Triplane Ultrasound Probe Bank Selection, Piezoelectric Transducer Charge Management, High-Voltage Relay Replacement, Medical Ultrasound Receive-Select Networks, Compact High-Voltage Probe Electronics.

💊

Biplane Ultrasound Probe Bank Selection

The MAX14806CCM+T fits biplane ultrasound probes because it routes 16 high-voltage analog channels as two independently selected eight-channel banks. A 200 V switch process supports the voltage excursions encountered in piezoelectric imaging systems, while DIN1 and DIN2 provide bank control from a 2.7 V to 5.5 V logic supply. Each terminal includes a 40 kΩ bleed resistor to help reduce residual voltage on capacitive transducer elements after deselection. The 48-LQFP, 7 mm by 7 mm package also allows the switching array to be placed close to the probe connector and transducer elements, reducing sensitive high-voltage trace lengths.

💊

Triplane Ultrasound Probe Bank Selection

The MAX14806CCM+T can serve as the bank-selection network in a triplane probe, where separate element groups require controlled high-voltage switching. Its two eight-channel SPST banks let the imaging system choose the active transducer group through DIN1 and DIN2, while the 16-channel architecture limits the number of discrete switch positions needed in the probe. The integrated 40 kΩ bleed resistors are particularly relevant when the selected elements present substantial capacitance to ground. Engineers should preserve adequate creepage and clearance around all switched nodes and review the pin-description table before laying out the 48-LQFP footprint.

🔧

Piezoelectric Transducer Charge Management

The MAX14806CCM+T is suitable for switching networks that connect to capacitive piezoelectric transducers and need a defined discharge path after a channel is deselected. Every switch terminal incorporates a 40 kΩ bleed resistor, helping reduce voltage buildup in the connected capacitive load. The device’s 16 SPST channels allow multiple transducer elements or groups to share a controlled interface, and the 200 V process is appropriate for high-voltage ultrasound switching. The design should still account for switch transition effects, external protection, leakage paths, and the time required for each transducer node to discharge before the next acquisition or transmit phase.

🏭

High-Voltage Relay Replacement

The MAX14806CCM+T can replace multiple discrete high-voltage relays in ultrasound imaging and similar analog-routing systems. Sixteen SPST switches are integrated into one 48-LQFP device, reducing component count and providing a compact alternative to a bank of mechanical or discrete solid-state relays. The integrated 40 kΩ bleed resistors provide a defined discharge route on every terminal, while DIN1 and DIN2 independently select two eight-channel groups. Before conversion, verify relay isolation voltage, contact capacitance, switching lifetime, and fail-safe behavior against the requirements of the original circuit; a smaller package alone does not guarantee equivalent system reliability.

🖥️

Medical Ultrasound Receive-Select Networks

The MAX14806CCM+T fits receive-select networks that route selected elements of a high-voltage ultrasound probe while isolating other channels. Its 16 ohm on resistance and 200 V process provide the core switching function, while the two-bank organization simplifies group selection across probe elements. The bleed resistors help capacitive nodes return toward a defined state after switching, which is useful in phased-array and receive multiplexing systems. Layout should keep the sensitive receive path away from high-voltage switching nodes, and the manufacturer’s complete application circuit should be used as the basis for decoupling, protection, and routing decisions.

📱

Compact High-Voltage Probe Electronics

The MAX14806CCM+T supports compact probe electronics by integrating 16 high-voltage SPST switches and their bleed resistors into a 7 mm by 7 mm surface-mount package. That integration can shorten connections to a multi-element piezoelectric connector while maintaining controlled bank selection through two digital inputs. The 2.7 V to 5.5 V logic interface is compatible with common embedded control systems, and the -40°C to +85°C rating covers industrial-temperature equipment. Thermal performance still depends on the PCB land pattern and copper area, while high-voltage safety depends on spacing, cleanliness, insulation, and the final enclosure or probe construction.

What is the MAX14806CCM+T?
The MAX14806CCM+T is a 16-channel high-voltage SPST analog switch IC for ultrasonic imaging. It provides two banks of eight switches, uses a 200 V process, and includes a 40 kΩ bleed resistor on every switch terminal. According to the Analog Devices manufacturer datasheet, the device is intended for bank selection in biplane and triplane ultrasound probes and for replacing high-voltage relays.
What are the key specifications of MAX14806CCM+T that engineers should know?
The MAX14806CCM+T combines 16 SPST channels, a 200 V high-voltage process, 16 ohm on resistance, and 40 kΩ bleed resistors in a 48-LQFP package. Its digital interface operates from 2.7 V to 5.5 V, and its specified temperature range is -40°C to +85°C. According to the Analog Devices manufacturer datasheet, the two independent eight-channel banks are controlled through DIN1 and DIN2.
Where can I download the MAX14806CCM+T datasheet PDF?
The official MAX14806CCM+T datasheet and product information are available from the Analog Devices MAX14806 product page at https://www.analog.com/en/products/max14806.html. The manufacturer documentation describes the 16-channel SPST architecture, 200 V process technology, 40 kΩ terminal bleed resistors, 48-LQFP package, and -40°C to +85°C operating range.
Where can I find the MAX14806CCM+T pinout?
Use the pin-description table and package drawing in the Analog Devices MAX14806 manufacturer datasheet for authoritative pin assignments. The component uses a 48-LQFP package measuring 7 mm by 7 mm, with DIN1 and DIN2 controlling the two eight-channel banks. Assign PCB connections only from that table so high-voltage switch terminals, logic inputs, supplies, and grounds are routed correctly.
Is MAX14806CCM+T suitable for ultrasound probe bank selection?
Yes, the MAX14806CCM+T is specifically suitable for ultrasound probe bank selection. According to the Analog Devices manufacturer datasheet, it provides 16 high-voltage SPST switches arranged as two eight-channel banks and is ideal for biplane and triplane probes. Its 40 kΩ bleed resistors also help reduce voltage buildup in capacitive piezoelectric loads.
What is the difference between MAX14806CCM+T and MAX14806CCM+?
The MAX14806CCM+T and MAX14806CCM+ identify the same MAX14806 device family and electrical configuration, while the +T designation distinguishes the tape-and-reel ordering option. Both are listed as 16-channel ultrasound switch ICs in 48-LQFP packages. Package-ordering codes should not be treated as different electrical designs when comparing their switch and thermal performance.
What can replace the MAX14806CCM+T?
The Supertex HV2731 is the documented drop-in replacement for the MAX14806CCM+. Analog Devices states that both devices use a 48-pin TQFP package and are specified over -40°C to +85°C. Confirm the complete pin description and application-specific high-voltage ratings against the manufacturer documentation before substituting the HV2731 in a finished ultrasound probe design.
Is the Supertex HV2731 a drop-in replacement for MAX14806CCM+T?
Yes, Analog Devices identifies the MAX14806CCM+ as a drop-in replacement for the Supertex HV2731, and the MAX14806CCM+T is the tape-and-reel ordering form of that device. The stated package match is 48-pin TQFP, and the specified temperature range for both is -40°C to +85°C. Final engineering approval should still include a review of pin functions and high-voltage operating limits.
When should I choose MAX14806CCM+T instead of the Supertex HV2731?
Choose the MAX14806CCM+T when you prefer the Analog Devices high-voltage ultrasound switch family and want its documented relationship to the Supertex HV2731. The MAX14806 provides two eight-channel SPST banks, a 200 V process, and integrated 40 kΩ bleed resistors. The HV2731 is appropriate when it is explicitly approved as a drop-in alternative and its complete electrical specification satisfies the probe design.
What is the MAX14806CCM+T price?
Current commercial pricing is not reproduced in this technical reference because it changes by order quantity, availability, and purchasing conditions. Use the Request a Quote form on this page to request current pricing, minimum order quantity, stock status, and lead time for MAX14806CCM+T. The form also allows you to specify reel packaging and required delivery quantity.
Where can I buy MAX14806CCM+T online?
The MAX14806CCM+T can be requested directly through the Request a Quote form on this page. Submit the exact MPN, required quantity, reel packaging preference, and destination country to obtain current availability, lead time, and commercial terms. This preserves the exact 48-LQFP tape-and-reel ordering designation instead of substituting a different package or temperature suffix.
What is the lead time and stock status for MAX14806CCM+T?
Current stock status and lead time must be confirmed through the Request a Quote form on this page. The form captures the exact MAX14806CCM+T ordering code and your required quantity so the order can be matched to current inventory and production planning. Ask for written confirmation of available quantity, earliest shipment date, and reel quantity before releasing the purchase order.
How does MAX14806CCM+T manage charge on piezoelectric elements?
The MAX14806CCM+T integrates a 40 kΩ bleed resistor on every switch terminal. According to the Analog Devices manufacturer datasheet, these resistors help reduce voltage buildup in capacitive loads such as piezoelectric elements. This is particularly important in ultrasound probes because residual transducer charge can affect subsequent switching, protection behavior, and the usable voltage margin of the imaging circuit.
Does MAX14806CCM+T meet RoHS and lead-free requirements?
The MAX14806CCM+T is identified as RoHS compliant and lead free. According to the MAX14806 manufacturer documentation and the corresponding manufacturer datasheet, the device is offered in a lead-free 48-LQFP package for surface-mount assembly. AEC-Q100 qualification, REACH status, halogen-free status, and conflict-minerals status are not established for this ordering option in the cited material.
What should I verify before using MAX14806CCM+T in a high-voltage PCB?
Verify the complete pin assignments, high-voltage node limits, board spacing, thermal design, and external transducer protection against the Analog Devices manufacturer datasheet. The MAX14806CCM+T uses a 200 V process and a 48-LQFP package, while its 2.7 V to 5.5 V supply applies to the control side. High-voltage clearance and creepage rules must therefore be applied separately to the switched nodes.

के लिए इंजीनियरिंग संदर्भ डेटा MAX14806CCM+T — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose the MAX14806CCM+T for a new ultrasound-probe switching design that requires 16 SPST channels, a 200 V switch process, and integrated 40 kΩ bleed resistors on every terminal. Its two independently controlled eight-channel banks map naturally to biplane and triplane probe selection. The Supertex HV2731 is appropriate when a documented drop-in substitution is needed because Analog Devices identifies it as a drop-in replacement in a 48-pin TQFP package. Before selecting the HV2731, verify its complete pin functions, on-resistance, bleed implementation, absolute maximum ratings, and lifecycle position against the finished probe requirements. The MAX14806CCM+ and MAX14806CCM+T ordering forms should not be treated as distinct electrical alternatives. If the design requires more than 16 channels, a different voltage range, or a package other than 48-LQFP, do not force a drop-in substitution; revise the switching architecture instead.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद HV2731
Brand Analog Devices Supertex
Package 48-LQFP, 7 mm x 7 mm 48-pin TQFP
Operating Temperature Range -40°C to +85°C -40°C to +85°C
Drop-In Relationship Analog Devices device Documented drop-in replacement for MAX14806CCM+

मुख्य विशेषताएँ

  • Documented cross-manufacturer drop-in path (बनामHV2731)
  • Integrated charge-management resistors (बनामHV2731)
  • Two independently controlled high-voltage banks (बनामHV2731)

डिज़ाइन नोट्स

Route every switched high-voltage node with the clearance and creepage required by the maximum working voltage, contamination conditions, board material, and applicable product safety standard. Keep the 200 V process rating separate from the 2.7 V to 5.5 V logic supply. Place the switching IC close to the probe connector or transducer interface where practical, but preserve guarded spacing around high-voltage pins and avoid routing sensitive receiver traces directly beneath them.

Do not assume that the integrated 40 kΩ bleed resistor discharges every external transducer network instantaneously. The effective discharge time also depends on capacitance, leakage, switch behavior, and connected circuitry. Check the voltage remaining on each node before the next transmit or receive phase. Also verify DIN1 and DIN2 logic levels against the 2.7 V to 5.5 V supply range instead of applying the high-voltage switch rating to the control inputs.

Use the manufacturer package drawing and pin-description table for the 48-LQFP land pattern, exposed-pad treatment, and pin numbering. If the PCB design uses thermal vias or exposed copper under the device, confirm that the mechanical and electrical land pattern matches the manufacturer guidance. Add local decoupling according to the reference circuit and provide a low-impedance ground path so high-current return currents do not flow through sensitive transducer return traces.

अनुपालन जानकारी

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
लीड फ्री
Yes
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

The device is identified as RoHS compliant and lead free. AEC-Q100 is not applicable to this ordering option, while REACH, halogen-free, and conflict-minerals status are not established in the cited material.

डेटा सत्यापन तिथि: 2026-11-02 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

MAX14806CCM+T datasheet MAX14806CCM+T pinout MAX14806CCM+T datasheet pdf MAX14806CCM+T equivalent MAX14806CCM+T replacement MAX14806CCM+T vs HV2731 MAX14806 16 channel ultrasound switch MAX14806CCM+T 200V switch MAX14806CCM+T 48-LQFP footprint MAX14806 ultrasound probe application MAX14806CCM+T price MAX14806CCM+T stock

संबंधित कंपोनेंट्स और शब्द

Analog Devices MAX14806CCM+T MAX14806CCM+ Supertex HV2731 high-voltage analog switch SPST switch ultrasound switch IC analog switch interface IC semiconductor biplane ultrasound probe triplane ultrasound probe piezoelectric transducer bleed resistor DIN1 DIN2 200 V process technology 48-LQFP package TQFP package surface-mount package RoHS lead-free charge injection high-voltage relay replacement
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें