AD585JP Precision Sample-and-Hold Amplifier | Analog Devices
MPN: AD585JP ✗ Akhir HidupAD585JP Ringkasan
A sample-and-hold amplifier is an analog signal-conditioning component that samples an input voltage during a controlled interval and then stores that voltage for later processing. It belongs to the amplifier IC family and the broader analog signal-acquisition hierarchy. By combining the sampling switch, amplifier, and holding capacitor in one monolithic implementation, the AD585JP reduces the number of separately matched discrete elements needed in a precision acquisition channel.
The central features of the AD585JP are its integrated high-performance operational amplifier, ultralow-leakage sampling switch, and FET-input integrating amplifier. The internal holding capacitor and matched application resistors are important because their integration supports accurate sample acquisition and flexible application design. The one-circuit configuration simplifies the external signal path while preserving the control required by high-speed data converters.
Technically, the AD585JP performs two distinct functions in each acquisition cycle. During acquisition, the analog switch connects the input to the internal sampling network, allowing the holding capacitor to charge toward the sampled voltage. During hold, the switch isolates the stored charge so that the amplifier can present a stable signal to the following converter or instrumentation circuitry. Low leakage limits charge loss during hold, while matched resistors reduce errors associated with the sampling network.
The AD585 is particularly suited to precision, high-speed 10-bit and 12-bit data-acquisition systems. Typical uses include multiplexed analog measurement systems, instrumentation front ends, laboratory data loggers, and signal-processing subsystems in which each converted sample must be captured and held with minimal acquisition or droop error. Its monolithic construction is especially useful where component matching, compact implementation, and repeatable system behavior are important.
A key design consideration is the relationship between acquisition time and source impedance. The source presented to the input must be capable of charging the internal holding capacitor through the complete acquisition interval. PCB layout should preserve short, low-noise input paths, while power-supply bypass capacitors should be positioned close to the device. Timing control must ensure that the hold command occurs only after the acquisition interval has elapsed and that the hold duration remains within the circuit droop limits.
This product record combines the AD585JP architecture and package information with practical implementation guidance, application context, and a structured path for evaluating replacement decisions. It is intended to help engineers establish the correct operating conditions, interface requirements, and PCB footprint before integrating the sample-and-hold amplifier into a precision measurement system.
Alternatif penggantian untuk AD585JP — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Tidak ada alternatif pengganti yang tersedia untuk produk ini.
Permintaan AlternatifAD585JP Rating Maksimal & Karakteristik Listrik
| Product Type | Sample-and-hold amplifier |
| Circuit Count | 1 circuit |
| Paket | 20-pin PLCC |
| Package Dimensions | 9 mm x 9 mm |
| Tipe Mounting | Surface mount |
| Architecture | Operational amplifier, ultralow-leakage analog switch, and FET-input integrating amplifier |
| Internal Holding Capacitor | 1 integrated holding capacitor |
| Matched Application Resistors | 1 matched application-resistor network |
| Rentang Suhu Kerja | 0°C to +70°C |
| Input Type | FET input |
| Signal Path | Series-coupled operational amplifier, analog switch, and integrating amplifier |
AD585JP 9 mm x 9 mm Diamant Konfigurasi Panduan
Konfigurasi pin untuk AD585JP (9 mm x 9 mm pakai pakai). Komponen analog ini memiliki pin masukan, keluaran, dan pengirim daya. Lihat datasheet produsen untuk konfigurasi pin offset null, kompensasi, dan pengaktifan. Ideal untuk peralatan sinyal dan kabel penggandaran.
Tidak ada data diatribut pin yang tersedia untuk AD585JP.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
AD585JP cocok untuk 6 aplikasis: High-Speed Data Acquisition, Precision Instrumentation, Multiplexed Analog Measurement, Laboratory Data Logging, Signal-Conditioning Front End, Industrial Control and Automation.
High-Speed Data Acquisition
The AD585JP fits the front end of a high-speed 10-bit or 12-bit data-acquisition system because it combines a high-performance operational amplifier, an ultralow-leakage analog switch, and a FET-input integrating amplifier with an internal holding capacitor. The matched application resistors and monolithic construction reduce the number of discrete elements involved in the sampling path. Place the acquisition timing between the source and the following ADC so that the input has settled before the hold command is issued, and maintain the required acquisition interval throughout the operating range.
Direkomendasikan
Precision Instrumentation
The AD585JP is suitable for precision instrumentation in which a measured analog signal must be captured and held before digitization. Its ultralow-leakage analog switch helps preserve the stored voltage during hold, while the integrated holding capacitor and matched application resistors support coordinated sampling behavior. The 20-pin PLCC package permits a compact analog section, although the source impedance must be low enough to complete acquisition within the available timing window and the input path should be shielded against interference.
Direkomendasikan
Multiplexed Analog Measurement
In a multiplexed analog measurement system, the AD585JP can provide the sampling and isolation function between a selected input and a downstream converter or measurement block. The internal switch separates the held voltage from the source during the hold interval, reducing the need for a separate hold capacitor and matching network. The design must allocate sufficient time for acquisition after each channel selection, account for switch-related timing, and keep channel-switching transients from coupling into the sensitive input and hold nodes.
Direkomendasikan
Laboratory Data Logging
The AD585JP can support laboratory data-logging channels that require a stable analog value during conversion or subsequent processing. Its integrated high-performance operational amplifier, internal holding capacitor, and matched resistors create a compact sample-and-hold stage suitable for precision 10-bit and 12-bit acquisition tasks. For slow logging systems, verify droop over the longest intended hold duration and keep the input conditioned so that leakage, settling, and acquisition errors remain below the measurement budget.
Direkomendasikan
Signal-Conditioning Front End
The AD585JP is appropriate for a precision signal-conditioning front end that must present a stable sample to an ADC, comparator, or digital processing stage. Its series-coupled operational amplifier, analog switch, and FET-input integrating amplifier perform the basic acquisition function without requiring a separately assembled sample-and-hold network. Place the device close to the converter when possible, use a low-noise reference and bypass strategy, and validate the complete acquisition interval against the converter’s sampling requirement.
Direkomendasikan
Industrial Control and Automation
The AD585JP can be used in a controlled industrial measurement interface when the required internal temperature range and analog timing are acceptable. Its integrated sampling path is useful for capturing a conditioned process or sensor signal before downstream conversion. The 0°C to +70°C operating range restricts use to appropriately conditioned commercial environments. Engineers should verify long-term droop, input leakage effects, acquisition settling, and power-supply behavior across the complete system operating condition.
Direkomendasikan
Data referensi engineering untuk AD585JP — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini |
|---|---|
| Package | 20-pin PLCC (9 mm x 9 mm) |
| Brand | Analog Devices |
| Product Type | Monolithic sample-and-hold amplifier |
| Circuit Count | 1 circuit |
| Operating Temperature Range | 0°C to +70°C |
| Mounting Type | Surface mount |
| Integrated Holding Capacitor | Yes |
| Matched Application Resistors | Yes |
| Sampling Switch | Ultralow-leakage analog switch |
| Input Stage | FET-input integrating amplifier |
Diferensiator Kunci
- Complete monolithic sampling architecture (vsDiscrete sample-and-hold implementation)
- Designed for 10-bit and 12-bit acquisition systems (vsGeneral-purpose slow sampling circuit)
- Integrated low-leakage hold path (vsExternally assembled switch-and-capacitor holder)
Catatan Desain
Do not shorten the acquisition interval unless the source can fully settle the internal holding capacitor. Acquisition time, source impedance, capacitance, and switch behavior determine how closely the held voltage represents the input. Use a low-output-impedance buffer when necessary and validate settling at the required conversion accuracy. The Analog Devices AD585 datasheet provides the timing and application framework needed for this check.
Keep the signal input, hold node, and associated return paths short and separated from switching and digital routes. Place supply-bypass components close to the device pins and use a compact, low-loop-layout connection to the source buffer. The package includes a sensitive internal holding network, so unnecessary copper area and long high-impedance traces can increase coupling and make the sampling behavior less repeatable.
Treat the hold duration as a droop budget rather than an unlimited storage interval. The switch leakage and internal capacitance determine how quickly the stored voltage changes, so compare the maximum required hold time with the allowable settling error. For slower systems, periodically refresh the sample or choose a lower-leakage sampling architecture. Verify the complete channel behavior with the actual source impedance and cable or PCB leakage environment.
Confirm the device supply limits, bypass capacitance, and startup sequence against the official AD585 datasheet before assigning power rails. Follow the manufacturer’s grounding and decoupling arrangement because improper supply bypassing can couple noise into the held voltage and undermine the benefit of the integrated low-leakage sampling switch. Keep analog and return connections consistent with the complete acquisition timing test.
Informasi Konformitas
The available product pages do not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable because AD585JP is a commercial-temperature analog IC rather than an automotive-qualified device.