AD708AH - Ultra-Low Offset Dual Op Amp | Analog Devices
MPN: AD708AH ✓ AktifAD708AH Ringkasan
An operational amplifier, commonly called an op amp, is a high-gain differential amplifier that uses external feedback to control gain and signal behavior. The AD708 belongs to the precision bipolar operational-amplifier family, which is part of the broader amplifier IC and semiconductor hierarchy. Its two amplifiers can perform independent functions in one package or support differential, filtering, and feedback configurations when their electrical matching is beneficial.
The AD708AH emphasizes precision rather than speed. Analog Devices specifies maximum input offset voltage of 30 µV and maximum offset voltage drift of 0.3 µV/°C. The device also provides a minimum open-loop gain of 5 V/µV, a minimum CMRR of 130 dB, and a minimum PSRR of 120 dB. These characteristics reduce errors in slow sensor signals, low-level voltage measurements, and precision feedback networks.
Noise performance is similarly suited to demanding measurements. The guaranteed maximum input voltage noise is 350 nV peak-to-peak from 0.1 Hz to 10 Hz. This low-frequency noise specification is important when the input source is a bridge, thermocouple, strain gauge, or other transducer with output signals in the microvolt-to-millivolt range. The manufacturer also describes typical offset-voltage drift of 0.1 µV/°C and maximum input bias-current drift of 25 pA/°C.
Typical uses include precision bridge amplifiers, low-level sensor interfaces, instrumentation amplifiers, laboratory measurement equipment, and high-accuracy current-feedback circuits. The dual configuration can reduce board area when a design needs two precision gain stages. Because an op amp can saturate or behave unexpectedly outside its common-mode range, engineers should verify input and output voltage limits against the operating conditions of the complete circuit.
A careful design should account for bias-current error, input offset voltage, resistor tolerance, and thermoelectric effects. Place the device close to sensitive input nodes, maintain a symmetric resistor network around each amplifier, and use low-noise, low-temperature-coefficient resistors when the measurement budget is tight. Stable reference and supply sources also help prevent input-common-mode and power-supply variations from dominating the remaining error.
This page organizes the AD708AH electrical characteristics, drop-in substitution status, application guidance, and design considerations into one engineering reference. It also explains where datasheet-level checks are required before precision measurements, PCB implementation, or lifecycle-dependent sourcing decisions.
Alternatif penggantian untuk AD708AH — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
AD708BQ
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
AD708AH Rating Maksimal & Karakteristik Listrik
| Product Type | Dual precision bipolar operational amplifier |
| Number of Amplifiers | 2 amplifiers |
| Maximum Input Offset Voltage | 30 µV |
| Maximum Offset Voltage Drift | 0.3 µV/°C |
| Typical Offset Voltage Drift | 0.1 µV/°C |
| Minimum Open-Loop Gain | 5 V/µV |
| Minimum CMRR | 130 dB |
| Minimum PSRR | 120 dB |
| Maximum Input Voltage Noise | 350 nV peak-to-peak from 0.1 Hz to 10 Hz |
| Maximum Input Bias Current Drift | 25 pA/°C |
| Maximum Offset Voltage Match | 30 µV |
| Supply Voltage Span | ±22 V |
| Total Power Dissipation | 650 mW |
| Architecture | Monolithic bipolar |
| Paket | 8-pin ceramic DIP |
| Tipe Mounting | Through-hole |
AD708AH 8-pin ceramic dip Diamant Konfigurasi Panduan
Konfigurasi pin untuk AD708AH (8-pin ceramic dip pakai pakai). Komponen analog ini memiliki pin masukan, keluaran, dan pengirim daya. Lihat datasheet produsen untuk konfigurasi pin offset null, kompensasi, dan pengaktifan. Ideal untuk peralatan sinyal dan kabel penggandaran.
Tidak ada data diatribut pin yang tersedia untuk AD708AH.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
AD708AH cocok untuk 6 aplikasis: Precision Bridge Sensor Signal Conditioning, Strain Gauge Measurement Front Ends, Thermocouple and Low-Level Voltage Acquisition, Precision Current Measurement, Laboratory Instrumentation Signal Chains, High-Accuracy Sensor Interface Modules.
Precision Bridge Sensor Signal Conditioning
The AD708AH fits low-level bridge measurements because each amplifier offers a maximum input offset voltage of 30 µV, maximum offset drift of 0.3 µV/°C, and a minimum CMRR of 130 dB. It can be used in a differential amplifier around a resistive bridge, converting small differential sensor outputs into a higher-level measurement signal while rejecting common-mode voltage. The design should use a matched resistor network and keep input traces short because resistance and layout mismatch can otherwise exceed the amplifier’s inherent offset performance.
Strain Gauge Measurement Front Ends
Strain-gauge outputs can be extremely small and temperature-sensitive, making the AD708AH’s 30 µV maximum offset voltage and 0.3 µV/°C maximum drift useful in a precision front end. Its 5 V/µV minimum open-loop gain supports accurate amplification of low-level differential signals, while 130 dB minimum CMRR helps reject environmental common-mode disturbances. Engineers should verify input bias current against the sensor’s source resistance and include sensor warm-up and thermal drift in the uncertainty budget.
Thermocouple and Low-Level Voltage Acquisition
A thermocouple produces a small differential voltage, so amplifier offset and noise can materially affect temperature accuracy. The AD708AH provides a guaranteed maximum input voltage noise of 350 nV peak-to-peak from 0.1 Hz to 10 Hz, together with 30 µV maximum offset voltage. This makes it suitable for precision low-frequency acquisition when paired with proper input filtering and protection. Place the amplifier near the sensor connection, avoid unnecessary copper area, and account for parasitic thermocouple voltages at solder junctions.
Precision Current Measurement
The AD708AH can amplify the voltage produced by a small shunt resistor when high common-mode rejection and low offset are required. Its 120 dB minimum PSRR reduces sensitivity to supply variation, while 130 dB minimum CMRR helps reject differential noise appearing on both shunt terminals. For accurate results, use a low-TCCT shunt, Kelvin connections where appropriate, and an amplifier input network that avoids leakage currents. The bidirectional nature of the two amplifiers also supports complementary current and voltage channels.
Laboratory Instrumentation Signal Chains
The AD708AH is appropriate for laboratory buffer and gain stages where a 30 µV maximum input offset voltage and 0.3 µV/°C maximum drift help preserve small DC signals. Its dual monolithic construction can implement two related precision channels in one 8-pin ceramic DIP package. In a bench instrument, minimize thermal gradients across the package and use symmetrical layouts around both inputs. Stability should be verified with the exact feedback network, load, supply, and output range used in production.
High-Accuracy Sensor Interface Modules
Compact sensor-interface modules benefit when two low-level channels can share one precision dual amplifier. The AD708AH offers 130 dB minimum CMRR, 120 dB minimum PSRR, and typically 0.1 µV/°C offset drift, helping preserve signal integrity before digitization. The ceramic DIP package also supports through-hole assembly and prototype rework. Board design should provide local supply bypassing, clean grounding, and input protection without introducing leakage or nonlinear behavior at the sensor interface.
Data referensi engineering untuk AD708AH — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini |
|---|---|
| Brand | Analog Devices |
| Package | 8-pin ceramic DIP |
| Amplifier Count | 2 |
| Architecture | Monolithic bipolar |
| Maximum Input Offset Voltage | 30 µV |
| Maximum Offset Voltage Drift | 0.3 µV/°C |
| Minimum Open-Loop Gain | 5 V/µV |
| Minimum CMRR | 130 dB |
| Minimum PSRR | 120 dB |
| Maximum Input Voltage Noise | 350 nV peak-to-peak from 0.1 Hz to 10 Hz |
| Supply Voltage Span | ±22 V |
| Total Power Dissipation | 650 mW |
Diferensiator Kunci
- Exceptionally low guaranteed offset voltage (vsGeneral-purpose dual operational amplifier)
- Low offset drift for changing temperatures (vsGeneral-purpose dual operational amplifier)
- High rejection of common-mode and supply disturbances (vsGeneral-purpose dual operational amplifier)
Catatan Desain
Keep each amplifier’s input traces short, symmetric, and away from switching nodes and high-current return paths. The AD708AH’s 130 dB minimum CMRR and 120 dB minimum PSRR support accurate rejection of common-mode and supply disturbances, but layout-induced leakage or pickup can still create errors. Use a continuous ground reference, avoid routing beneath sensitive inputs, and place input protection components close enough that their leakage remains controlled.
Do not calculate expected accuracy from the 30 µV maximum offset voltage alone. Include offset drift across the expected temperature range, input bias-current error, resistor tolerance and mismatch, reference accuracy, and 0.1 Hz to 10 Hz input noise. For low-level bridge or thermocouple measurements, use matched, low-noise resistors and include connector or solder-junction thermoelectric effects when the measurement resolution is in the microvolt range.
Confirm the complete circuit’s supply and common-mode limits against the Analog Devices AD708 datasheet before energizing the amplifier. The device supports a ±22 V span, but that does not make every operating point safe: input common-mode voltage, output swing, input differential voltage, and load current must also remain within their specified limits. Provide local supply bypassing and check startup behavior so an input or output condition does not remain outside the amplifier’s linear operating region.
For precision measurements, treat temperature gradients across the package as a design variable. The guaranteed maximum offset drift is 0.3 µV/°C, while typical drift is 0.1 µV/°C. Place the device away from regulators, switching converters, and other heat sources when possible, maintain consistent airflow, and avoid placing one amplifier near a warm reference while the other remains near a cold source. Differential drift can undermine matching even when absolute room-temperature specifications are met.
Informasi Konformitas
The Analog Devices product and datasheet excerpts do not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for AD708AH. AEC-Q100 is not applicable to this precision analog operational amplifier.