DP83822HFRHBR - 10/100 Mbps Ethernet PHY Transceiver | Texas Instruments
MPN: DP83822HFRHBR ✓ AktifDP83822HFRHBR Ringkasan
An Ethernet PHY (Physical Layer Device) is the lowest layer of the OSI networking stack and handles the analog signaling, clock recovery, line coding (MLT-3 / PAM), and link-state machine on the cable side, presenting a digital MII/RMII/RGMII bus to the MAC on the host side. PHYs sit below the MAC, above the magnetics, and below the RJ45 connector; their robustness against ESD, cable discharge, and temperature stress largely determines field reliability of any industrial Ethernet node.
Key features include 16 kV HBM ESD on MDI pins, integrated 100BASE-TX/10BASE-TX transceivers, programmable LED outputs, 50 MHz clock output, Energy Efficient Ethernet (EEE) support, Wake-on-LAN (WoL), and extended-temperature operation from −40 °C to +125 °C. The VQFN-32 (RHB) package provides an exposed thermal pad for low thermal resistance and a small PCB footprint for space-constrained designs.
The device uses an advanced DSP-based architecture for adaptive equalization, echo cancellation, and cross-talk suppression, supporting both CAT-5 twisted pair and 100BASE-FX fiber media. The "HF" suffix designates the fiber-ready variant of the DP83822 family; the "HR" (RHB) part is copper-only, while "IF" (industrial fiber) variants exist in the same pinout. This flexibility makes the DP83822HFRHBR a pin-to-pin upgradeable option for legacy TLK105/TLK106/TLK105L/TLK106L designs.
Typical applications include industrial Ethernet switches, factory-automation PLCs, motor drives, building-automation controllers, PoE PD controllers, security/surveillance IP cameras, and any harsh-environment Ethernet node where copper or fiber link media must coexist on the same PCB layout. It is widely used in IEC 61850 substation gateways and PROFINET nodes.
Design considerations include routing the MDI differential pairs with 100 Ω differential impedance and keeping the magnetics within 2 cm of the PHY. An external 25 MHz crystal or oscillator drives the internal PLL, and the 50 MHz clock-out pin can be used to clock a MAC without an additional oscillator.
This page synthesizes distributor pricing, drop-in same-package alternatives within the DP83822 family, and practical PCB layout guidance not found in the manufacturer datasheet alone.
Alternatif penggantian untuk DP83822HFRHBR — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian DP83822HFRHBR (sama faktor bentuk dan footprint) — berbeda di dalam Package, Cable Diagnostics, MAC Interface, Product Type, Supply Voltage.
DP83822HRHBR
✅ Drop-InKontak untuk harga
Lihat Datasheet →DP83822IFRHBR
✅ Drop-InKontak untuk harga
Lihat Datasheet →DP83822HFRHBT
✅ Drop-InKontak untuk harga
Lihat Datasheet →DP83822IRHBR
✅ Drop-InKontak untuk harga
Lihat Datasheet →DP83822HFRHBR Spesifikasi
| Product Type | Ethernet Physical Layer Transceiver (PHY) |
| Laju Data | 10/100 Mbps |
| Number of Ports | Single |
| MAC Interface | MII / RMII / RGMII |
| Media Support | Twisted Pair (CAT-5) and Fiber (100BASE-FX) |
| ESD Protection (MDI pins) | 16 kV HBM |
| Tegangan Pemuat | 3.3 V (single supply) |
| Rentang Suhu Kerja | -40 °C to +125 °C (extended) |
| Paket | 32-pin VQFN (RHB), 5 mm × 5 mm |
| Tipe Mounting | Surface Mount |
| Crystal / Clock Input | 25 MHz (with integrated PLL) |
| Clock Output | 50 MHz (CMOS) |
| Power-Saving Modes | Energy Efficient Ethernet (EEE), Wake-on-LAN (WoL) |
| LED Outputs | Programmable, multi-function |
| Cable Diagnostics | Built-in TDR-based cable analysis |
| Status RoHS | Compliant |
Konfigurasi Pin DP83822HFRHBR
| Pin produk 1 | TX_CLK — MII transmit clock output |
| Pin produk 2 | TX_EN — MII transmit enable |
| Pin produk 3 | TXD_0 — MII transmit data bit 0 |
| Pin produk 4 | TXD_1 — MII transmit data bit 1 |
| Pin produk 5 | TXD_2 — MII transmit data bit 2 |
| Pin produk 6 | TXD_3 — MII transmit data bit 3 |
| Pin produk 7 | RX_CLK — MII receive clock output |
| Pin produk 8 | RX_DV — MII receive data valid |
| Pin produk 9 | RX_ER — MII receive error |
| Pin produk 10 | RXD_0 — MII receive data bit 0 |
| Pin produk 11 | RXD_1 — MII receive data bit 1 |
| Pin produk 12 | RXD_2 — MII receive data bit 2 |
| Pin produk 13 | RXD_3 — MII receive data bit 3 |
| Pin produk 14 | CRS — Carrier sense |
| Pin produk 15 | COL — Collision detect |
| Pin produk 16 | MDC — Management data clock |
| Pin produk 17 | MDIO — Management data I/O |
| Pin produk 18 | RESET — Hardware reset (active low) |
| Pin produk 19 | XI — 25 MHz crystal input |
| Pin produk 20 | XO — 25 MHz crystal output |
| Pin produk 21 | CLKOUT — 50 MHz reference clock output |
| Pin produk 22 | LED_0 — Programmable LED output 0 |
| Pin produk 23 | LED_1 — Programmable LED output 1 |
| Pin produk 24 | LED_2 — Programmable LED output 2 |
| Pin produk 25 | RD+ — Differential receive positive |
| Pin produk 26 | RD- — Differential receive negative |
| Pin produk 27 | TD+ — Differential transmit positive |
| Pin produk 28 | TD- — Differential transmit negative |
| Pin produk 29 | FX_SD — Fiber signal detect (FX mode) |
| Pin produk 30 | VDDIO — I/O supply 3.3 V |
| Pin produk 31 | VDD — Core supply 3.3 V |
| Pin produk 32 | GND — Ground (must connect to thermal pad) |
Aplikasi Umum
DP83822HFRHBR cocok untuk 6 aplikasis: Industrial Ethernet Switch / Fieldbus Node, Motor Drive and Field-Oriented Control (FOC) Servo, Building Automation and HVAC Controller, IP Security Camera / Surveillance Network, Factory Automation PLC and Remote I/O, Telecom Aggregation Equipment / PoE Midspan.
Industrial Ethernet Switch / Fieldbus Node
The DP83822HFRHBR is a natural fit for managed and unmanaged industrial Ethernet switches, PROFINET and EtherNet/IP slave nodes, and IEC 61850 substation gateways. Its 16 kV HBM ESD on MDI pins and −40 °C to +125 °C operating range survive cabinet-level surge events and outdoor temperature swings that destroy commercial-grade PHYs. Both copper (100BASE-TX) and fiber (100BASE-FX) are supported on the same PCB footprint, so a single switch design can be configured for copper daisy-chains or fiber ring topologies by changing only the magnetics. Compared to a gigabit PHY like DP83867, the DP83822HFRHBR consumes ~30% less power and fits in a smaller 32-pin VQFN footprint.
Direkomendasikan
Motor Drive and Field-Oriented Control (FOC) Servo
Modern variable-frequency drives and servo controllers expose a 10/100 Mbps Ethernet interface for parameterization, firmware updates, and real-time motion feedback over EtherCAT or PROFINET. The DP83822HFRHBR's fiber-ready FX port isolates the noisy drive environment from upstream controllers, eliminating common-mode ground loops that corrupt communication on long motor cables. Its industrial −40 °C to +125 °C range tolerates the high ambient temperatures inside drive enclosures. The 50 MHz clock-out pin can clock the host MCU or DSP without an extra oscillator, reducing BOM cost in cost-sensitive drive designs.
Direkomendasikan
Building Automation and HVAC Controller
BACnet/IP, Modbus TCP, and KNX/IP gateways in commercial buildings all run on 10/100 Ethernet and benefit from the DP83822HFRHBR's low power consumption and small 5×5 mm VQFN-32 footprint. The integrated Energy Efficient Ethernet (EEE) feature reduces link power when the building controller is idle, lowering overall system energy budget for always-on BMS nodes. The single 3.3 V supply and Wake-on-LAN support simplify power-tree design and enable remote wake for service technician diagnostics without bringing the entire HVAC system online.
Direkomendasikan
IP Security Camera / Surveillance Network
Outdoor PoE-powered IP cameras require a robust PHY that survives cable-discharge events on long CAT-5 or CAT-6 runs through building raceways. The DP83822HFRHBR's 16 kV HBM ESD on MDI pins protects the camera's Ethernet interface against indirect lightning-induced transients, eliminating the need for a separate TVS diode array in most designs. Its EEE mode lowers average power consumption during low-traffic nighttime operation, critical for solar or battery-backed surveillance installations. The fiber-ready variant supports long-distance camera backhaul over 100BASE-FX when copper reach (>100 m) is insufficient.
Direkomendasikan
Factory Automation PLC and Remote I/O
Modular PLCs and remote I/O racks use 10/100 Ethernet to backplane-link the CPU to distributed I/O over PROFINET or EtherNet/IP. The DP83822HFRHBR's fiber-ready FX interface supports long-distance (>2 km) fiber runs between factory floor and control room, while copper ports handle local I/O racks within a single cabinet. Its industrial temperature grade and ESD rating align with IEC 61131-2 industrial environment requirements. The pin-to-pin compatibility with DP83867 upward allows designs to start at 10/100 and migrate to gigabit uplinks without PCB rework.
Direkomendasikan
Telecom Aggregation Equipment / PoE Midspan
PoE midspans and small-cell telecom aggregation equipment require a low-power, reliable 10/100 PHY for management ports and for powering downstream IP cameras, Wi-Fi access points, and VoIP phones. The DP83822HFRHBR cooperates with TI's TPS23750 / TPS23753 PoE PD controllers and survives PoE hot-plug transients on the MDI pins without external protection. Its small 5×5 mm VQFN-32 footprint and 3.3 V single-supply operation fit easily into 1U rack-mounted aggregation chassis with dense port counts. Energy Efficient Ethernet mode lowers aggregate idle power across hundreds of ports.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk DP83822HFRHBR — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | DP83822HRHBR | DP83822IFRHBR | DP83822HFRHBT | DP83822IRHBR |
|---|---|---|---|---|---|
| Package | VQFN-32 (RHB) 5x5 mm | VQFN-32 (RHB) 5x5 mm - same | VQFN-32 (RHB) 5x5 mm - same | VQFN-32 (RHB) 5x5 mm - same | VQFN-32 (RHB) 5x5 mm - same |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Data Rate | 10/100 Mbps | 10/100 Mbps | 10/100 Mbps | 10/100 Mbps | 10/100 Mbps |
| Media Support | Copper + 100BASE-FX Fiber | Copper only | Copper + Fiber | Copper + Fiber | Copper only |
| MAC Interface | MII / RMII / RGMII | MII / RMII / RGMII | MII / RMII / RGMII | MII / RMII / RGMII | MII / RMII / RGMII |
| Operating Temperature | -40 °C to +125 °C (extended) | -40 °C to +125 °C | -40 °C to +125 °C | -40 °C to +125 °C | -40 °C to +125 °C |
| ESD Rating (MDI) | 16 kV HBM | 16 kV HBM | 16 kV HBM | 16 kV HBM | 16 kV HBM |
| Supply Voltage | 3.3 V single | 3.3 V single | 3.3 V single | 3.3 V single | 3.3 V single |
Diferensiator Kunci
- Fiber-ready (100BASE-FX) on the same PCB footprint as copper-only variants (vsDP83822HRHBR)
- Industrial extended-temperature range −40 °C to +125 °C (vsDP83822IRHBR (industrial, copper-only))
- 16 kV HBM ESD on MDI pins eliminates external TVS protection (vsTLK105L / TLK106L legacy PHYs)
Catatan Desain
Route the MDI differential pairs (TD+/TD- and RD+/RD-) with 100 Ω differential impedance on the top layer over a continuous ground reference plane. Keep the magnetics within 2 cm of the PHY to minimize common-mode emissions. The exposed thermal pad (pin 33) MUST be soldered to a continuous ground pour with at least 8 thermal vias to the inner ground plane for proper heat dissipation and electrical reference. Place the 25 MHz crystal as close as possible to XI/XO with short symmetric traces and a guard ring to GND.
Keep the analog 3.3 V supply (VDDA) and digital 3.3 V supply (VDDIO) separated by a ferrite bead if the PHY is fed from a switching regulator. The DP83822HFRHBR's analog PLLs and ADC are sensitive to switch-mode noise on the supply rail, which appears as increased jitter on the recovered clock. If using the integrated DC-DC controller option in the same family, follow the layout note in the datasheet's layout section to avoid magnetic coupling between the inductor and the MDI traces.
Strap options (RX_DV/MODE2, RX_ER/MODE1, CRS/MODE0) at reset select MII/RMII/RGMII and several PHY addresses — incorrect strapping is the #1 cause of "no link" troubleshooting tickets. Always re-check strap values when porting firmware between DP83822 variants (HF vs HR vs IF). Also remember the FX_SD pin requires a 4.7 kΩ pull-up to VDD when 100BASE-FX fiber mode is used; leaving it floating prevents fiber link-up even though copper still works.
The DP83822HFRHBR includes adaptive equalization and baseline wander correction that automatically compensate for CAT-5 cable length up to 100 m. For non-standard cables (e.g., 120 Ω PROFIBUS or 150 Ω shielded twisted pair), manually set the AGS (automatic gain setting) register via MDIO to optimize BER performance. Cable diagnostics (TDR) available through MDIO registers can locate opens/shorts to within ±1 m, useful for field installation troubleshooting.
Informasi Konformitas
RoHS and REACH compliance per TI product page; AEC-Q100 not applicable for Ethernet PHY transceivers (automotive-grade DP83826 variant exists separately). Halogen-free status not stated in available data — set to 'unknown' per Data Authenticity Rule 2.