ICL7126CPLZ - 3.5-Digit LCD ADC | Renesas Electronics
MPN: ICL7126CPLZ ✗ Akhir HidupICL7126CPLZ Ringkasan
An integrating ADC is a voltage-to-digital conversion category that measures an unknown input by integrating a reference-derived current and comparing the result against an oscillator count. In this architecture, conversion time is tied to oscillator behavior and measurement accuracy is influenced by reference stability, input leakage, integration time, and the connected display and external networks. The ICL7126 integrates the conversion and display functions to reduce the number of components required for a compact panel instrument.
Key features include direct LCD segment and backplane drive, an integrated reference and clock, low-power operation, and a 3.5-digit conversion format. According to the Renesas ICL7126 datasheet, the device contains all active circuitry needed for the converter and display interface on one CMOS IC. This integration is useful in digital panel meters, handheld instruments, laboratory equipment, and other systems where a compact numerical display is required.
The ICL7126 uses a dual-slope integrating conversion approach, with the Renesas family described as operating at approximately 3 samples per second under specified conditions. A fixed or selectable integration interval helps reject periodic noise when the input and reference relationships are appropriately arranged. The on-chip reference, clock, segment decoder, and display drivers simplify the analog front end while preserving a direct connection to a suitable LCD.
Typical applications include battery-operated voltmeters, thermometers, pressure indicators, panel meters, laboratory meters, and compact sensing instruments. The 100 µA supply-current figure is particularly relevant to battery-operated products because display loading, conversion timing, reference implementation, and external passive leakage can materially affect the complete system budget.
Design the PCB with short analog input and reference connections, clean grounding around the converter, and careful routing of LCD drive lines to minimize coupling into the measurement input. Confirm the external reference, display, and timing components against the manufacturer application guidance. Because ICL7126CPLZ is obsolete, engineers should also assess supply continuity and long-term availability before starting a new production design.
This page combines device capabilities, package and lifecycle information, strict drop-in alternatives, comparison parameters, and practical design guidance. It also distinguishes confirmed drop-in candidates from options that require pin and timing verification, helping engineers evaluate replacements before committing to a PCB revision.
Alternatif penggantian untuk ICL7126CPLZ — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian ICL7126CPLZ (sama faktor bentuk dan footprint) — berbeda di dalam ADC Architecture, Conversion Rate, Display Resolution.
ICL7126CPL+
✅ Drop-InKontak untuk harga
Lihat Datasheet →TC7126CPL
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
ICL7126CPLZ Rating Maksimal & Karakteristik Listrik
| ADC Architecture | Dual-slope integrating ADC |
| Display Resolution | 3.5 digits, 1999 counts |
| Conversion Rate | 3 samples per second |
| Arus Pemuat | 100 µA |
| Process Technology | CMOS |
| Tipe Output | Direct seven-segment LCD drive |
| Integrated Functions | Segment decoders, display drivers, voltage reference, and clock |
| Backplane Drive | Integrated |
| Paket | 40-pin PDIP |
| Jumlah Pin | 40 pins |
| Tipe Mounting | Through-hole |
| Status RoHS | unknown |
| REACH Status | unknown |
ICL7126CPLZ 40-pin pdip Diamant Konfigurasi Panduan
Konfigurasi pin untuk ICL7126CPLZ (40-pin pdip pakai pakai). Komponen analog ini memiliki pin masukan, keluaran, dan pengirim daya. Lihat datasheet produsen untuk konfigurasi pin offset null, kompensasi, dan pengaktifan. Ideal untuk peralatan sinyal dan kabel penggandaran.
Tidak ada data diatribut pin yang tersedia untuk ICL7126CPLZ.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
ICL7126CPLZ cocok untuk 6 aplikasis: Battery-Powered Digital Panel Meter, Digital Voltmeter, Temperature Display Instrument, Pressure Gauge Display, Laboratory Digital Readout, Field-Service Data Logger.
Battery-Powered Digital Panel Meter
ICL7126CPLZ fits a battery-powered panel meter because the converter combines a 3.5-digit, 1999-count readout with a stated 100 µA supply current. The integrated clock, voltage reference, segment decoders, LCD drivers, and backplane drive reduce the external component count and simplify a compact instrument. A typical implementation places the converter beside the LCD and uses the manufacturer reference network to establish the measurement range. The 3-sample-per-second update rate is appropriate for slowly changing quantities such as battery voltage, temperature, or pressure. Final battery-life calculations must include LCD load and external component leakage.
Direkomendasikan
Digital Voltmeter
ICL7126CPLZ is appropriate for a compact digital voltmeter where a direct three-and-a-half-digit LCD display improves readability over indicator LEDs. Its dual-slope integrating architecture, integrated reference, clock, and display interface consolidate the measurement chain into one IC. The designer selects the input divider, reference components, and display according to the intended range and accuracy. The approximately 3-sample-per-second conversion rate suits stable readings rather than rapidly changing waveforms. PCB routing should keep the input and reference paths away from LCD drive traces to reduce coupling into the measured voltage.
Direkomendasikan
Temperature Display Instrument
ICL7126CPLZ can present a scaled temperature or resistance measurement on a dedicated LCD. The 3.5-digit resolution supplies 1999 display counts, while the integrated reference and clock simplify a battery-operated handheld instrument. A front-end sensor and signal-conditioning network convert the physical quantity into a voltage accepted by the converter. Because the device is an integrating ADC, stable excitation, reference behavior, and input filtering directly influence displayed accuracy. The 40-pin PDIP package is appropriate for through-hole assembly, but new compact products may favor a smaller contemporary mixed-signal solution.
Direkomendasikan
Pressure Gauge Display
ICL7126CPLZ is suitable for a pressure-gauge indicator where a clear numerical LCD reading is more useful than a simple threshold lamp. A pressure transducer or resistive bridge produces a proportional voltage that the converter measures and displays at approximately 3 samples per second. The integrated segment drivers and backplane output keep the display interface compact, while the integrated reference supports a repeatable measurement baseline. Layout should isolate bridge excitation and sensing routes from LCD outputs. For new designs, verify pressure-transducer excitation requirements, noise sensitivity, calibration range, and the availability of an active alternative.
Direkomendasikan
Laboratory Digital Readout
ICL7126CPLZ can serve as the numerical readout stage in a laboratory meter designed around slow analog measurements. The 3.5-digit display format, integrated clock, reference, decoder, and LCD driver reduce assembly complexity compared with a discrete ADC and display interface. The approximately 3-sample-per-second conversion rate is well matched to temperature, pressure, resistance, and slowly changing voltage measurements. For a bench instrument, the obsolete status is the main lifecycle concern, so retain the original part only where the instrument is already built and verified or where long-term supply has been secured.
Direkomendasikan
Field-Service Data Logger
ICL7126CPLZ is appropriate for a simple field-service logger that needs a local numerical display while measurements are being configured or checked. Its low stated 100 µA supply current supports portable operation, and the direct LCD drive removes the need for a separate display-driver IC. A logger can sample the displayed conversion or use an external control circuit to record the measurement. The display provides useful service feedback without adding a communications radio to the basic instrument. Design the analog input and reference sections for low leakage, verify startup behavior, and plan a replacement path because the converter is obsolete.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk ICL7126CPLZ — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | ICL7126CPL+ | TC7126CPL |
|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Renesas Electronics | Maxim Integrated | Microchip Technology |
| Converter Type | 3.5-digit integrating A/D converter | 3.5-digit A/D converter | 3.5-digit CMOS A/D converter |
| Display Resolution | 3.5 digits, 1999 counts | 3.5 digits | 3.5 digits |
| Display Interface | Direct seven-segment LCD drive with backplane drive | Direct non-multiplexed LCD drive | LCD display driver output |
Diferensiator Kunci
- Highest-confidence family continuity (vsTC7126CPL)
- Integrated panel-meter functionality (vsICL7126CPL+)
- Defined numerical display resolution (vsTC7126CPL)
Catatan Desain
Route the analog input and reference nets as short, quiet traces and place their associated passive components close to the ICL7126CPLZ. Keep LCD segment and backplane drive traces physically separated from the measurement input to reduce capacitive injection and display-dependent errors. Provide a stable ground reference for the analog section and use the manufacturer pin configuration when planning the 40-pin PDIP footprint.
Budget the complete instrument rather than the converter alone. The stated 100 µA supply current is a key low-power characteristic, but LCD operation, reference components, input leakage, and switching circuitry contribute additional consumption. Verify the permitted supply range, decoupling arrangement, and startup behavior in the Renesas ICL7126 datasheet before selecting batteries or regulators.
Do not assume that every 3.5-digit LCD ADC is automatically interchangeable. Before fitting ICL7126CPL+ or TC7126CPL to an existing board, compare pin names, segment and common polarity, reference configuration, oscillator timing, conversion sequence, and absolute electrical limits. The shared 40-pin PDIP format establishes mechanical compatibility but does not by itself prove identical timing or display behavior.
Treat the obsolete lifecycle status as a sourcing decision point, not merely an administrative label. For maintenance builds, request remaining factory stock, date-code information, and traceability. For new products, compare the obsolete converter against an active mixed-signal ADC and display-driver design, including package size, accuracy, availability, and the cost of requalifying the complete instrument.
Informasi Konformitas
The obsolete Renesas product page and ICL7126 datasheet do not provide explicit compliance conclusions for the exact ICL7126CPLZ ordering code.