ICL7126CPLZ Ringkasan

Renesas Electronics ICL7126CPLZ is a low-power, 3.5-digit single-chip analog-to-digital converter with direct seven-segment LCD drive in a 40-pin PDIP package. The monolithic CMOS device integrates seven-segment decoders, display drivers, a voltage reference, a clock circuit, and backplane drive. Its stated 100 µA supply current is suitable for battery-powered measurement equipment, while the 3.5-digit readout provides 1999 counts of resolution.

An integrating ADC is a voltage-to-digital conversion category that measures an unknown input by integrating a reference-derived current and comparing the result against an oscillator count. In this architecture, conversion time is tied to oscillator behavior and measurement accuracy is influenced by reference stability, input leakage, integration time, and the connected display and external networks. The ICL7126 integrates the conversion and display functions to reduce the number of components required for a compact panel instrument.

Key features include direct LCD segment and backplane drive, an integrated reference and clock, low-power operation, and a 3.5-digit conversion format. According to the Renesas ICL7126 datasheet, the device contains all active circuitry needed for the converter and display interface on one CMOS IC. This integration is useful in digital panel meters, handheld instruments, laboratory equipment, and other systems where a compact numerical display is required.

The ICL7126 uses a dual-slope integrating conversion approach, with the Renesas family described as operating at approximately 3 samples per second under specified conditions. A fixed or selectable integration interval helps reject periodic noise when the input and reference relationships are appropriately arranged. The on-chip reference, clock, segment decoder, and display drivers simplify the analog front end while preserving a direct connection to a suitable LCD.

Typical applications include battery-operated voltmeters, thermometers, pressure indicators, panel meters, laboratory meters, and compact sensing instruments. The 100 µA supply-current figure is particularly relevant to battery-operated products because display loading, conversion timing, reference implementation, and external passive leakage can materially affect the complete system budget.

Design the PCB with short analog input and reference connections, clean grounding around the converter, and careful routing of LCD drive lines to minimize coupling into the measurement input. Confirm the external reference, display, and timing components against the manufacturer application guidance. Because ICL7126CPLZ is obsolete, engineers should also assess supply continuity and long-term availability before starting a new production design.

This page combines device capabilities, package and lifecycle information, strict drop-in alternatives, comparison parameters, and practical design guidance. It also distinguishes confirmed drop-in candidates from options that require pin and timing verification, helping engineers evaluate replacements before committing to a PCB revision.

Pilihan pengganti yang segera untuk ICL7126CPLZ — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Varietas dalam siri ini

Model serupa yang kompatibel dengan pengganti yang segera ICL7126CPLZ (sama faktor bentuk dan kaki) — berbeza dalam ADC Architecture, Conversion Rate, Display Resolution.

Analog Devices
ADC Architecture: Monolithic CMOS integrating ADC
Conversion Rate: 3 conversions per second
Display Resolution: 3.5 digits
Bandingkan Dengan ICL7126CPLZ →

ICL7126CPL+

✅ Masuk Drop-In
Analog Devices
📦 40-pin PDIP
3.5-digit dual-slope analog-to-digital converter · Analog Devices Inc./Maxim Integrated · Dual-slope · 3 conversions per second · 3.5 digits · Single analog input · Monolithic CMOS integrating ADC · Yes

Hubungi untuk harga

Lihat Datasheet →

TC7126CPL

✅ Masuk Drop-In
📦 40-pin PDIP
Same 3.5-digit integrating ADC and 40-pin PDIP format; display polarity, timing, and electrical details require final verification

📋 Alternatif rujukan (tidak dalam katalog)

ICL7126CPLZ Penilaian maksimum & Ciri-ciri Elektrik

ADC Architecture Dual-slope integrating ADC
Display Resolution 3.5 digits, 1999 counts
Conversion Rate 3 samples per second
Arus Pemberi Arus 100 µA
Process Technology CMOS
Jenis Output Direct seven-segment LCD drive
Integrated Functions Segment decoders, display drivers, voltage reference, and clock
Backplane Drive Integrated
Kemasan 40-pin PDIP
Kiraan Pin 40 pins
Jenis Pemasangan Through-hole
Status RoHS unknown
REACH Status unknown

Panduan Konfigurasi Pin ICL7126CPLZ 40-pin pdip

Konfigurasi pin untuk ICL7126CPLZ (40-pin pdip pakai). Komponen analog ini mempunyai pin masukan, keluaran, dan kuasa. Rujuk dokumen pengeluar untuk konfigurasi pengecualian, pemulihan, dan pin aktifkan. Ideal untuk pengawasan isyarat dan litar pengukur.

Garis bentuk pengecah pakai 40-pin pdip untuk ICL7126CPLZ

Tiada data garisan pin yang diperoleh untuk ICL7126CPLZ.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

ICL7126CPLZ patut untuk 6 aplikasis: Battery-Powered Digital Panel Meter, Digital Voltmeter, Temperature Display Instrument, Pressure Gauge Display, Laboratory Digital Readout, Field-Service Data Logger.

🔋

Battery-Powered Digital Panel Meter

ICL7126CPLZ fits a battery-powered panel meter because the converter combines a 3.5-digit, 1999-count readout with a stated 100 µA supply current. The integrated clock, voltage reference, segment decoders, LCD drivers, and backplane drive reduce the external component count and simplify a compact instrument. A typical implementation places the converter beside the LCD and uses the manufacturer reference network to establish the measurement range. The 3-sample-per-second update rate is appropriate for slowly changing quantities such as battery voltage, temperature, or pressure. Final battery-life calculations must include LCD load and external component leakage.

📏

Digital Voltmeter

ICL7126CPLZ is appropriate for a compact digital voltmeter where a direct three-and-a-half-digit LCD display improves readability over indicator LEDs. Its dual-slope integrating architecture, integrated reference, clock, and display interface consolidate the measurement chain into one IC. The designer selects the input divider, reference components, and display according to the intended range and accuracy. The approximately 3-sample-per-second conversion rate suits stable readings rather than rapidly changing waveforms. PCB routing should keep the input and reference paths away from LCD drive traces to reduce coupling into the measured voltage.

🌡️

Temperature Display Instrument

ICL7126CPLZ can present a scaled temperature or resistance measurement on a dedicated LCD. The 3.5-digit resolution supplies 1999 display counts, while the integrated reference and clock simplify a battery-operated handheld instrument. A front-end sensor and signal-conditioning network convert the physical quantity into a voltage accepted by the converter. Because the device is an integrating ADC, stable excitation, reference behavior, and input filtering directly influence displayed accuracy. The 40-pin PDIP package is appropriate for through-hole assembly, but new compact products may favor a smaller contemporary mixed-signal solution.

🏭

Pressure Gauge Display

ICL7126CPLZ is suitable for a pressure-gauge indicator where a clear numerical LCD reading is more useful than a simple threshold lamp. A pressure transducer or resistive bridge produces a proportional voltage that the converter measures and displays at approximately 3 samples per second. The integrated segment drivers and backplane output keep the display interface compact, while the integrated reference supports a repeatable measurement baseline. Layout should isolate bridge excitation and sensing routes from LCD outputs. For new designs, verify pressure-transducer excitation requirements, noise sensitivity, calibration range, and the availability of an active alternative.

🧪

Laboratory Digital Readout

ICL7126CPLZ can serve as the numerical readout stage in a laboratory meter designed around slow analog measurements. The 3.5-digit display format, integrated clock, reference, decoder, and LCD driver reduce assembly complexity compared with a discrete ADC and display interface. The approximately 3-sample-per-second conversion rate is well matched to temperature, pressure, resistance, and slowly changing voltage measurements. For a bench instrument, the obsolete status is the main lifecycle concern, so retain the original part only where the instrument is already built and verified or where long-term supply has been secured.

🖥️

Field-Service Data Logger

ICL7126CPLZ is appropriate for a simple field-service logger that needs a local numerical display while measurements are being configured or checked. Its low stated 100 µA supply current supports portable operation, and the direct LCD drive removes the need for a separate display-driver IC. A logger can sample the displayed conversion or use an external control circuit to record the measurement. The display provides useful service feedback without adding a communications radio to the basic instrument. Design the analog input and reference sections for low leakage, verify startup behavior, and plan a replacement path because the converter is obsolete.

Ringkasan Produk Disebarkan

CD4053BMG4 Texas Instruments Dipergunakan di: Battery-Powered Digital Panel Meter, Digital Voltmeter, Temperature Display Instrument, Pressure Gauge Display, Laboratory Digital Readout, Field-Service Data Logger CD4067BMPRE Multiplexer option for expanded measurement inputs Dipergunakan di: Battery-Powered Digital Panel Meter CD4538BMPRE Timing support for instrument control Dipergunakan di: Digital Voltmeter CD4093BMRE Logic conditioning for control signals Dipergunakan di: Temperature Display Instrument CD4078BMRE Threshold and alarm conditioning Dipergunakan di: Pressure Gauge Display CD4536BMPRE Programmable control and timing support Dipergunakan di: Laboratory Digital Readout CD4040BMRE Counter for control and logging functions Dipergunakan di: Field-Service Data Logger
What is ICL7126CPLZ?
ICL7126CPLZ is a Renesas Electronics 3.5-digit, low-power, single-chip CMOS analog-to-digital converter with direct seven-segment LCD drive. According to the Renesas ICL7126 datasheet, it integrates the converter, segment decoders, display drivers, voltage reference, clock, and backplane drive. It is packaged in a 40-pin PDIP and is intended for compact numerical panel displays powered from limited supply budgets.
What is the resolution of ICL7126CPLZ?
ICL7126CPLZ provides 3.5-digit resolution, corresponding to 1999 counts. The ICL7126 family description identifies the device as a 3.5-digit integrating A/D converter with an approximately 3-sample-per-second conversion rate. This resolution suits panel meters and handheld instruments that need stable numerical readings without the complexity of a separate display controller.
How much current does ICL7126CPLZ use?
The ICL7126CPLZ has a stated supply current of 100 µA. The Renesas product information identifies that figure as suitable for 9 V battery-powered equipment. Actual product consumption can vary with supply voltage, conversion activity, display configuration, and external components, so battery-life calculations should include the complete display and peripheral load rather than only the converter current.
Is ICL7126CPLZ still active?
No. Renesas lists ICL7126CPLZ as obsolete on its official product page. Existing equipment may still use the device, but new production designs should confirm lifecycle status, remaining supply, and long-term sourcing before approving a release. For an existing PCB, verify the exact ordering code, package, temperature suffix, and display requirements before selecting a replacement.
Where can I download the ICL7126CPLZ datasheet?
The official ICL7126 datasheet is available from Renesas Electronics at the product document page linked on this page. It contains the device description, electrical characteristics, pin descriptions, application information, and display-interface guidance. Because ICL7126CPLZ is obsolete, use the current ICL7126 family document together with the exact part-ordering information for the 40-pin PDIP package.
Where can I find the ICL7126CPLZ pinout?
The ICL7126CPLZ pin assignments are shown in the pin-configuration section of the Renesas ICL7126 datasheet. The device is a 40-pin PDIP, and its pins include analog input, reference, timing, supply, ground, segment-drive, and backplane-drive functions. Use the package drawing and pin table together because the LCD outputs must be assigned to the intended segment and common display arrangement.
What can replace ICL7126CPLZ?
ICL7126CPL+ from Analog Devices/Maxim Integrated is the closest confirmed drop-in candidate because it uses the same ICL7126 device family and 40-pin PDIP format. TC7126CPL from Microchip is another functionally similar 3.5-digit CMOS ADC option, but the manufacturer documentation should be checked for display polarity, timing, reference, and pin-level differences before treating it as a production substitute.
Is ICL7126CPLZ the same as ICL7126CPL+?
ICL7126CPLZ and ICL7126CPL+ belong to the same ICL7126 converter family and are listed in the same 40-pin PDIP format. Their exact ordering suffixes still need to be checked for temperature grade, package details, lead finish, and purchasing terms. Confirm the ordering table and electrical limits rather than assuming that the suffix difference has no impact on qualification.
ICL7126CPLZ vs TC7126CPL: which is better for a panel meter?
Choose ICL7126CPLZ when preserving the Renesas ICL7126 implementation is the priority, and choose TC7126CPL only after verifying its LCD drive and timing against the existing PCB. Both devices are described as 3.5-digit CMOS panel-meter ADCs, but a common measurement function does not by itself prove interchangeable pin behavior. Verify polarity, common drive, segment count, reference arrangement, and startup timing.
When should I choose ICL7126CPLZ over a modern ADC?
ICL7126CPLZ is most appropriate for maintenance of an existing 40-pin PDIP panel-meter design whose display, reference network, timing, and PCB are already established. For a new design, a modern ADC and separate display controller may offer more flexibility, diagnostics, and sourcing options. Choose the obsolete part only when compatibility, availability, and requalification considerations outweigh modern design benefits.
Is ICL7126CPLZ suitable for a battery-powered meter?
ICL7126CPLZ is suitable for a battery-powered meter when the system can operate within its supply and display constraints. Its stated 100 µA supply current is designed for low-power operation, and the integrated clock, reference, and LCD drivers reduce the number of external power-hungry components. The complete design must still budget for LCD load, analog-reference components, leakage, and display-driver activity.
Does ICL7126CPLZ need an external LCD driver?
ICL7126CPLZ does not require a separate seven-segment LCD driver for its intended display format because segment decoders and display drivers are integrated on the chip. The device also includes backplane drive. The LCD itself, passive timing components, reference components, and PCB layout remain part of the implementation, and the connected display must match the expected segment and common-drive arrangement.
What are the key specifications of ICL7126CPLZ that engineers should know?
The key specifications are 3.5-digit, 1999-count resolution; an approximately 3-sample-per-second conversion rate; 100 µA stated supply current; CMOS integration of the reference, clock, decoders, and display drivers; direct seven-segment LCD output; and a 40-pin PDIP package. These figures define the converter’s basic architecture and low-power panel-meter role, while voltage limits, accuracy, and absolute temperature ratings require checking in the Renesas datasheet.
Where can I buy ICL7126CPLZ and what is the lead time?
Use the Request a Quote form on this page to request ICL7126CPLZ availability, current unit pricing, minimum order quantity, and production lead time. Renesas identifies the exact ICL7126CPLZ ordering code as obsolete, so availability may depend on remaining factory stock or authorized channel inventory. Request the lot-specific date code and traceability information before committing the component to a build.
What is the price of ICL7126CPLZ?
Current commercial terms for ICL7126CPLZ should be requested through the Request a Quote form on this page because the device is obsolete and its supply status can change independently of regular active-part pricing. Include the required quantity, shipment date, acceptable date-code range, and packaging needs in the request. This allows the quote to reflect the exact obsolete-part sourcing constraints for your build.

Data referensi kejuruteraan untuk ICL7126CPLZ — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Choose ICL7126CPLZ when maintaining an existing Renesas ICL7126 panel-meter PCB where changing the display, reference network, timing, or measurement behavior would create unnecessary risk. ICL7126CPL+ is the preferred alternative when the goal is continuity with the same converter family and 40-pin PDIP construction, provided that ordering suffixes, temperature grade, lead finish, and electrical limits are checked. Consider TC7126CPL when its LCD drive, reference, conversion timing, and pin functions match the existing circuit; otherwise it should be treated as a functionally similar alternative rather than an automatic substitution. For a new design, compare an active precision ADC and separate display interface against the obsolete ICL7126CPLZ, including accuracy, power, package size, lifecycle, and instrumentation requalification requirements.

Perbandingan dengan Gantian

Parametr Produk Ini ICL7126CPL+ TC7126CPL
Package 40-pin PDIP 40-pin PDIP 40-pin PDIP
Brand Renesas Electronics Maxim Integrated Microchip Technology
Converter Type 3.5-digit integrating A/D converter 3.5-digit A/D converter 3.5-digit CMOS A/D converter
Display Resolution 3.5 digits, 1999 counts 3.5 digits 3.5 digits
Display Interface Direct seven-segment LCD drive with backplane drive Direct non-multiplexed LCD drive LCD display driver output

Penyeberangsung Jelas

  • Highest-confidence family continuity (vsTC7126CPL)
  • Integrated panel-meter functionality (vsICL7126CPL+)
  • Defined numerical display resolution (vsTC7126CPL)

Catatan Desain

Route the analog input and reference nets as short, quiet traces and place their associated passive components close to the ICL7126CPLZ. Keep LCD segment and backplane drive traces physically separated from the measurement input to reduce capacitive injection and display-dependent errors. Provide a stable ground reference for the analog section and use the manufacturer pin configuration when planning the 40-pin PDIP footprint.

Budget the complete instrument rather than the converter alone. The stated 100 µA supply current is a key low-power characteristic, but LCD operation, reference components, input leakage, and switching circuitry contribute additional consumption. Verify the permitted supply range, decoupling arrangement, and startup behavior in the Renesas ICL7126 datasheet before selecting batteries or regulators.

Do not assume that every 3.5-digit LCD ADC is automatically interchangeable. Before fitting ICL7126CPL+ or TC7126CPL to an existing board, compare pin names, segment and common polarity, reference configuration, oscillator timing, conversion sequence, and absolute electrical limits. The shared 40-pin PDIP format establishes mechanical compatibility but does not by itself prove identical timing or display behavior.

Treat the obsolete lifecycle status as a sourcing decision point, not merely an administrative label. For maintenance builds, request remaining factory stock, date-code information, and traceability. For new products, compare the obsolete converter against an active mixed-signal ADC and display-driver design, including package size, accuracy, availability, and the cost of requalifying the complete instrument.

Maklumat Kesediaan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

The obsolete Renesas product page and ICL7126 datasheet do not provide explicit compliance conclusions for the exact ICL7126CPLZ ordering code.

Pencarian Berhubungan

ICL7126CPLZ datasheet ICL7126CPLZ pinout ICL7126CPLZ datasheet pdf ICL7126CPLZ price ICL7126CPLZ equivalent ICL7126CPLZ replacement Renesas ICL7126CPLZ ICL7126CPLZ 40-pin PDIP ICL7126CPLZ 3.5 digit ADC ICL7126CPLZ battery panel meter ICL7126CPLZ vs ICL7126CPL+ ICL7126CPLZ vs TC7126CPL ICL7126CPLZ stock what is ICL7126CPLZ

Komponen dan Tanda berkaitan

Renesas Electronics ICL7126CPLZ ICL7126 ICL7126CPL+ Maxim Integrated TC7126CPL Microchip Technology 3.5-digit ADC analog-to-digital converter dual-slope integrating ADC seven-segment display driver LCD backplane drive integrated voltage reference integrated clock 100 µA supply current 1999-count resolution 40-pin PDIP PDIP package family through-hole mounting battery-powered instrumentation digital panel meter digital voltmeter pressure gauge display CMOS Renesas ICL7126 datasheet
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ