INA146UA/2K5 - High-Voltage Difference Amplifier | Texas Instruments
MPN: INA146UA/2K5 ✓ AktifINA146UA/2K5 Ringkasan
A difference amplifier is a precision analog signal-conditioning device that amplifies the voltage difference between two inputs while suppressing a voltage common to both inputs. Within the broader hierarchy, the INA146 is a difference amplifier, a type of operational-amplifier IC and analog signal-conditioning component. Its high-voltage input range makes it useful when signals exceed the conventional common-mode limits of many low-voltage amplifier families.
The /2K5 ordering code identifies an external gain resistor of 2.5 kOhm. With the INA146 gain equation, this produces a differential gain of 21 V/V. A single external resistor therefore sets the gain while allowing the design to retain accurate operation across a wide supply range. The 550 kHz gain-bandwidth product supports signal bandwidth appropriate for industrial measurement, current sensing, and instrumentation systems.
Key electrical characteristics include 570 uA typical quiescent current, a 36 V maximum total supply, and an operating temperature range from -40 C to +85 C. The input common-mode range can extend beyond the supply rails, providing additional protection for high-side or floating measurements. The 8-pin SOIC package supports conventional surface-mount assembly and is narrower and more thermally capable than the smallest SOT packages.
Architecturally, the INA146 combines precision difference-amplifier behavior with high-voltage tolerance. Input protection is inherent in the high-voltage design, but the external gain resistor remains a sensitive accuracy element. Resistor tolerance and temperature coefficient directly affect gain accuracy, so a low-tolerance precision resistor should be used when calibration is important. Supply bypassing and clean grounding are equally critical because they directly influence differential measurement accuracy.
Typical uses include high-side current sensing in motor drives, industrial sensor interfaces, power-supply current measurement, precision bridge excitation, and medical or laboratory instrumentation where signals may exceed ground-centered common-mode limits. For current sensing, the amplifier can sit across a low-value shunt and provide a scaled measurement while rejecting voltage shared by both shunt terminals.
The main design trade-off is bandwidth. A gain of 21 V/V with a 550 kHz gain-bandwidth product provides useful signal speed but does not target precision measurement bandwidths extending into megahertz ranges. Check the resulting closed-loop bandwidth, output swing, supply voltage, and input polarity against the intended signal before finalizing the resistor and filter values.
This page combines the manufacturer ordering information, electrical characteristics, gain-setting guidance, comparison options, and application-focused design notes to support faster component selection and PCB implementation.
Alternatif penggantian untuk INA146UA/2K5 — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian INA146UA/2K5 (sama faktor bentuk dan footprint).
INA146UA
✅ Drop-InKontak untuk harga
Lihat Datasheet →INA146UA/2K5E4
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
INA146UAE4
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
INA148UA/2K5G4
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
AD628ARZ
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
INA146UA/2K5 Rating Maksimal & Karakteristik Listrik
| Tidak ada spesifikasi tersedia |
Konfigurasi Pin INA146UA/2K5
| Pin produk 1 | RG — Gain resistor connection |
| Pin produk 2 | IN- — Inverting input |
| Pin produk 3 | IN+ — Non-inverting input |
| Pin produk 4 | V- — Negative supply connection |
| Pin produk 5 | RG — Gain resistor connection |
| Pin produk 6 | OUT — Amplified output |
| Pin produk 7 | V+ — Positive supply connection |
| Pin produk 8 | REF — Reference input |
Aplikasi Umum
INA146UA/2K5 cocok untuk 6 aplikasis: High-Side Motor Current Sensing, Industrial Sensor Signal Conditioning, Power-Supply Current Measurement, Precision Bridge Excitation, Laboratory Instrumentation Front End, Medical Monitoring Signal Chain.
High-Side Motor Current Sensing
The INA146UA/2K5 fits high-side current measurement when the shunt sits near a motor supply and its common-mode voltage exceeds ordinary amplifier input limits. The amplifier measures the small differential voltage across the shunt while its ±15 V common-mode capability rejects the much larger voltage shared by both inputs. With the 2.5 kOhm gain-resistor option, the differential gain is 21 V/V, and the 550 kHz gain-bandwidth product provides an estimated signal bandwidth of about 26 kHz at that gain. Use a Kelvin connection from the shunt to reduce parasitic resistance and error, then verify the output swing, shunt power, and amplifier supply during motor transients.
Direkomendasikan
Industrial Sensor Signal Conditioning
The INA146UA/2K5 can condition differential outputs from pressure, strain, and industrial bridge sensors when the sensor common-mode voltage is higher than the signal amplitude. Its 21 V/V configured gain expands millivolt-level differential signals, while common-mode rejection prevents shared sensor excitation from appearing at the output. The 570 uA typical quiescent current suits compact multi-channel measurement systems, and the 4.5 V to 36 V supply range provides flexibility in industrial equipment. For accurate bridge measurements, use the specified gain resistor, maintain symmetry in the input routing, and keep high-current sensor returns away from the amplifier ground reference.
Direkomendasikan
Power-Supply Current Measurement
The INA146UA/2K5 is appropriate for measuring current through a low-value shunt in high-voltage power-supply circuitry because its input common-mode range extends beyond the supply rails. A shunt amplifier placed above the load rail can measure current without interrupting the ground reference, reducing system disturbance. The 21 V/V gain provides useful scaling for a shunt voltage in the millivolt range, while the 550 kHz gain-bandwidth product allows the measurement to follow moderate transients. Check shunt dissipation, Kelvin routing, amplifier output swing, and common-mode voltage during startup and load-step events before applying the circuit to production hardware.
Direkomendasikan
Precision Bridge Excitation
The INA146UA/2K5 can amplify the small differential output of a resistive bridge while rejecting the larger excitation voltage appearing at both inputs. Its 21 V/V configured gain is useful when the bridge output is too small for an ADC without substantial amplification, and its input architecture supports measurement at elevated common-mode voltages. The low 570 uA typical quiescent current reduces system overhead, while single- or dual-supply operation supports different instrumentation architectures. Use low-tolerance gain and reference components when gain accuracy matters, avoid placing the gain resistor near high-current return paths, and validate offset and gain error over the required temperature range.
Direkomendasikan
Laboratory Instrumentation Front End
The INA146UA/2K5 provides a compact front end for laboratory instruments that measure differential signals superimposed on a substantial common-mode voltage. The 21 V/V gain increases low-level detector or sensor outputs, while the extended input range reduces the need to level-shift signals before amplification. Its 550 kHz gain-bandwidth product supports bandwidth beyond static DMM measurements without attempting to position it as a high-speed precision instrument amplifier. The 8-pin SOIC package is easy to prototype and replace, and the 570 uA typical quiescent current is useful in portable equipment. Place supply-bypass capacitors near the device and preserve symmetry between differential input paths.
Direkomendasikan
Medical Monitoring Signal Chain
The INA146UA/2K5 can serve as a high-common-mode differential stage in medical monitoring equipment when the measured biopotential or sensor output requires amplification before conversion. Its 21 V/V configured gain and extended common-mode input range support front-end conditioning, while the 570 uA typical quiescent current is favorable for multi-channel systems. The 4.5 V to 36 V supply range allows operation across compact single-supply and higher-voltage instrumentation architectures. For patient-connected circuits, apply the required medical isolation and protection design outside the amplifier; use shielded routing, clean grounding, and carefully selected gain resistors to prevent small differential signals from being contaminated by common-mode or coupled interference.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk INA146UA/2K5 — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | INA146UA | INA146UA/2K5E4 | INA146UAE4 | INA148UA/2K5G4 | AD628ARZ |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC |
Diferensiator Kunci
- High common-mode capability with extended input range (vsAD628ARZ)
- Defined 21 V/V configuration (vsINA146UA)
- Same-family INA146 electrical behavior (vsINA148UA/2K5G4)
Catatan Desain
Do not treat the 2.5 kOhm suffix as a gain value. It identifies the external gain resistor, which produces a gain of 21 V/V for INA146UA/2K5. Resistor tolerance and temperature coefficient become direct gain-error contributors. Use the precision resistor specified by the design, keep both RG connections short, and avoid routing the resistor near switching nodes or high-current return paths.
Place the gain resistor and input compensation components close to their associated pins, and route IN+ and IN− as a short, tightly coupled differential pair. Connect the shunt or bridge directly to the input pins using Kelvin traces so voltage drops in copper or solder do not become part of the measured differential signal. Keep the REF connection quiet and provide a defined path to the reference network when it is not used.
Bypass each supply connection with a local high-frequency ceramic capacitor and add suitable bulk capacitance near the amplifier for transient current. The 570 uA typical quiescent current is low, but output current and the external feedback network can increase supply demand. Ensure the output remains within its voltage swing at the selected 21 V/V gain and that the input common-mode voltage stays within the operating limits during startup, shutdown, and fault conditions.
Informasi Konformitas
Texas Instruments product information identifies the device as halogen-free compliant. RoHS, REACH, lead-free, and conflict-minerals status were not confirmed by the available manufacturer results.