LAN8700IC-AEZG-TR - 10/100 Ethernet PHY | Microchip
MPN: LAN8700IC-AEZG-TR ✓ AktifLAN8700IC-AEZG-TR Ringkasan
An Ethernet PHY is the physical-layer component that converts digital frame data into electrical signals suitable for a twisted-pair Ethernet cable. It sits below the Ethernet MAC in the protocol hierarchy and above the physical magnetics and connector. The LAN8700 family is categorized as a variable-I/O-voltage analog interface IC for embedded Ethernet systems, with MII and RMII host interfaces allowing integration with microcontrollers, processors, and programmable logic.
The principal feature set includes support for both 10 Mbps and 100 Mbps Ethernet operation, full MII and RMII interfaces, HP Auto-MDIX, ±15 kV ESD protection, and flexPWR technology. The variable-I/O arrangement helps accommodate systems in which the PHY communicates with host logic operating at a lower voltage. A 50 MHz reference clock with a tolerance of ±50 ppm and a duty cycle from 40% through 60% provides the timing reference used by the LAN8700/LAN8700i family.
From a design perspective, the PHY separates Ethernet medium access from the host processor’s digital bus. MII provides separate controls and parallel data paths, while RMII reduces the number of host-interface signals for compact embedded designs. The network side connects through the external magnetics path required by a conventional 10/100BASE-T Ethernet port, allowing the PHY to remain independent from the connector and transformer implementation.
Typical implementations include industrial embedded controllers, networked sensors, building-automation equipment, communications modules, and compact data-acquisition systems. The part is particularly useful when an embedded processor already provides a MII or RMII interface and the design needs standards-based 10/100 Ethernet connectivity without implementing analog Ethernet signaling directly.
The primary design consideration is matching the host bus voltage, clock requirements, and digital timing to the selected processor. PCB layout must also preserve the differential characteristics of the transmit and receive pairs, maintain appropriate separation from switching circuitry, and follow the manufacturer’s guidance for the QFN exposed pad and external magnetics network.
This page combines interface capabilities, ordering information, application guidance, package details, and replacement analysis to support faster engineering evaluation. It also distinguishes true package-compatible alternatives from related Ethernet products that would require different pinouts, interfaces, or board layouts.
Alternatif penggantian untuk LAN8700IC-AEZG-TR — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
LAN8700C-AEZG-AR2
✅ Drop-InKontak untuk harga
Lihat Datasheet →LAN8700C-AEZG
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
LAN8700IC-AEZG-TR Spesifikasi
| Product Type | 10/100 Ethernet physical-layer transceiver |
| Supported Data Rates | 10 Mbps and 100 Mbps |
| Tegangan Pemuat | 3.3 V |
| Host Interface | Full MII and RMII |
| Ethernet Channel Count | 1 channel |
| Network Interface | Analog 10/100BASE-T Ethernet |
| Auto-MDIX | HP Auto-MDIX supported |
| ESD Protection | ±15 kV |
| Reference Clock Frequency | 50 MHz ±50 ppm |
| Reference Clock Duty Cycle | 40% to 60% |
| Paket | 36-pin QFN, 6 mm × 6 mm |
| Exposed Pad | Present |
| Tipe Mounting | Surface mount |
| Shipping Format | Tape and reel |
| Operating Temperature Class | Industrial temperature |
| Power Technology | flexPWR technology |
LAN8700IC-AEZG-TR 36-pin qfn, 6 mm × 6 mm Diamant Konfigurasi Panduan
Konfigurasi pin untuk LAN8700IC-AEZG-TR (36-pin qfn, 6 mm × 6 mm pakai pakai). Penomoran pin, fungsi, dan diagram koneksi ditetapkan dalam datasheet produsen. Lihatnya untuk footprint dan pedoman perpindahan paruh.
Tidak ada data diatribut pin yang tersedia untuk LAN8700IC-AEZG-TR.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
LAN8700IC-AEZG-TR cocok untuk 6 aplikasis: Industrial Embedded Controller, Networked Sensor Gateway, Building Automation Controller, Communications Equipment, Data Acquisition System, Networked Test and Measurement Instrument.
Industrial Embedded Controller
The LAN8700IC-AEZG-TR fits an industrial embedded controller that must add 10/100 Mbps Ethernet without implementing analog signaling directly. Its full MII and RMII support lets the design select the host interface that best matches the MCU, while the 3.3 V supply aligns with many embedded processors. The 36-pin QFN package limits board area while retaining separate digital and analog functions. The manufacturer identifies the family for industrial-temperature embedded Ethernet, and its ±15 kV ESD protection adds interface ruggedness. The reference clock must remain at 50 MHz ±50 ppm with a 40% to 60% duty cycle. A key design trade-off is that RMII saves host pins but demands tighter clock and signal-integrity control than a more conventional parallel interface.
Direkomendasikan
Networked Sensor Gateway
A compact sensor gateway can use the LAN8700IC-AEZG-TR to convert a host processor’s digital data into a 10/100 Mbps Ethernet physical-layer signal. The one-channel PHY supports both 10 Mbps and 100 Mbps operation, making it suitable for management traffic or an embedded network segment that does not require Gigabit Ethernet. Its 6 mm × 6 mm QFN package helps preserve compactness in distributed sensing equipment. HP Auto-MDIX simplifies connection to both straight-through and crossover cabling. The implementation should keep the 50 MHz reference source within ±50 ppm and 40% to 60% duty cycle, and should isolate the analog network section from noisy digital or switching circuitry on the PCB.
Direkomendasikan
Building Automation Controller
The LAN8700IC-AEZG-TR is suitable for building-automation controllers that communicate over 10/100 Ethernet while sharing a board with sensors, relays, and control logic. The MII interface provides a conventional parallel host path, whereas RMII provides a lower-pin-count option for space-constrained controller designs. A 3.3 V operating supply and a 36-pin surface-mount QFN align with current industrial control hardware. HP Auto-MDIX reduces cabling complexity, and the manufacturer’s industrial-temperature positioning supports equipment intended for harsh indoor environments. Layout remains critical: the Ethernet differential pairs should be routed as controlled-impedance nets, separated from switching nodes, and connected to the prescribed external magnetics network.
Direkomendasikan
Communications Equipment
The LAN8700IC-AEZG-TR can provide wired Ethernet connectivity in communications equipment requiring 10/100 Mbps rather than Gigabit performance. Full MII support is useful when the host system already has a conventional parallel Ethernet interface, while RMII can simplify wiring between the PHY and a modern communications processor. The device’s 50 MHz reference clock is used as the network clock, helping simplify the transmit data path. At the same time, the clock source must meet ±50 ppm accuracy and a 40% to 60% duty cycle. The QFN package’s exposed pad requires proper thermal and electrical land-pattern implementation, while the analog Ethernet section requires careful isolation from high-current switching circuitry.
Direkomendasikan
Data Acquisition System
A compact data-acquisition system can use the LAN8700IC-AEZG-TR to transfer measurement and control data over a 10/100 Ethernet link. The PHY supports MII or RMII according to the selected host processor, allowing the same Ethernet approach to be reused across different embedded control boards. Its 3.3 V operation and small 6 mm × 6 mm QFN package are useful where analog measurement circuitry already consumes most available board area. HP Auto-MDIX simplifies installation by detecting cable polarity. For reliable data transfer, the design must provide clean clocking, isolate Ethernet pairs from sensitive analog inputs, and follow the manufacturer’s recommended stack-up and magnetics layout to minimize insertion loss and impedance discontinuities.
Direkomendasikan
Networked Test and Measurement Instrument
The LAN8700IC-AEZG-TR is appropriate for test and measurement instruments that need a low-power Ethernet management or data port. The 10/100 Mbps interface is sufficient for supervisory traffic, configuration, logging, and moderate-rate measurement transfers. Because the device supports both MII and RMII, the instrument can reuse an existing host platform or simplify a new design. The industrial-temperature classification supports equipment deployed beyond consumer-office environments, while ±15 kV ESD protection strengthens the external network connection. Engineering teams should still budget for external magnetics and carefully controlled 100-ohm differential routing. The 50 MHz clock source and QFN exposed-pad layout must meet the manufacturer’s timing and thermal recommendations.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk LAN8700IC-AEZG-TR — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | LAN8700C-AEZG-AR2 | LAN8700C-AEZG |
|---|---|---|---|
| Package | 36-pin QFN, 6 mm × 6 mm | 36-pin QFN, 6 mm × 6 mm | 36-pin QFN, 6 mm × 6 mm |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology |
| Ethernet Channel Count | 1 channel | 1 channel | 1 channel |
| Supported Data Rates | 10 Mbps and 100 Mbps | 10 Mbps and 100 Mbps | 10 Mbps and 100 Mbps |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V |
| Host Interface | Full MII and RMII | Full MII and RMII | Full MII and RMII |
| Mounting Type | Surface mount | Surface mount | Surface mount |
Diferensiator Kunci
- Supports both full MII and RMII in one PHY (vsLAN8700C-AEZG-AR2)
- Single-channel 10/100 Mbps Ethernet in a compact QFN (vsLAN8700C-AEZG)
- Industrial-oriented interface with network protection (vsLAN8700C-AEZG-AR2)
Catatan Desain
Route the Ethernet transmit and receive pairs as controlled-impedance differential nets with continuous reference planes and avoid introducing stubs or layer transitions. Keep the PHY-to-magnetics section electrically compact, match the manufacturer’s recommended trace geometry, and separate these pairs from switching nodes, clocks, and high-current power paths. Since the PHY contains analog transceiver circuitry, uninterrupted return paths and a stable ground plane are important for reducing radiated emissions and susceptibility to ESD events.
Use the manufacturer’s recommended input, output, and bypass-capacitor arrangement directly from the datasheet application circuit. Place high-frequency decoupling close to the 3.3 V supply pins and provide a quiet return connection for the exposed pad. Do not assume that the analog Ethernet section and digital host interface have identical supply-current behavior; evaluate the host voltage range, startup sequence, and the flexPWR configuration against the complete system power architecture before releasing the layout.
The reference clock must be 50 MHz within ±50 ppm and have a duty cycle from 40% through 60%, inclusive. Because the LAN8700/LAN8700i family uses this reference as the network clock, excessive clock jitter, distortion, or noise can affect both MII and RMII timing. Source the clock from a low-noise oscillator, provide a short return path, avoid sharing long clock routes with unrelated signals, and validate rise time, jitter, and duty cycle at the PHY pin.
Do not substitute a 36-pin Ethernet PHY solely because the package count matches. Before approving a replacement, compare MII versus RMII availability, variable-I/O behavior, clock requirements, Auto-MDIX behavior, ESD rating, power architecture, exposed-pad implementation, and operating-temperature requirements. For LAN8700C-AEZG-AR2 and LAN8700C-AEZG, also verify the exact ordering suffix and assembly carrier so the production BOM and tape-and-reel process remain correct.
Informasi Konformitas