Analog Devices

AD524CDZ - Precision Instrumentation Amplifier | Analog Devices

部品番号: AD524CDZ ✓ 生産中
50 uV Vdss 16-lead ceramic DIP (CDIP-16) Package
MOQ: 1 |

AD524CDZ 概要

The Analog Devices AD524CDZ is a precision monolithic instrumentation amplifier packaged in a 16-lead ceramic DIP. It provides one amplifier circuit, an input offset voltage of 50 uV maximum, approximately 1 MHz bandwidth, and a 5 V/us slew rate. The device supports externally resistor-programmed gain as well as pin-programmable gains of 1, 10, 100, and 1000.

An instrumentation amplifier is a precision differential amplifier optimized for measuring small differential signals while rejecting large common-mode voltages. The AD524 belongs to the hierarchy of operational amplifiers, instrumentation amplifiers, analog signal-chain ICs, and semiconductor-based data-acquisition components. Its monolithic construction combines amplifier, gain-setting, and protection functions into a single device for sensor and bridge-amplifier front ends.

Programmable gain covering 1, 10, 100, and 1000 allows one amplifier design to accommodate signals spanning millivolts to volts without redesigning the analog board. Input and output offset nulling terminals support precision applications and help minimize offset-voltage changes during gain ranging. The manufacturer also describes external resistor gain programming, built-in compensation, overvoltage protection, and protection during both power-on and power-off fault conditions.

The AD524 is designed for precision data acquisition where input signals originate from strain gauges, RTDs, thermocouples, bridge transducers, and low-level process sensors. A 50 uV maximum offset keeps errors small relative to many millivolt-level sensor outputs, while the approximately 1 MHz bandwidth supports relatively slow industrial and laboratory measurement loops. The 5 V/us slew rate provides full-power-bandwidth capability for the device's operating class.

Common applications include weighing systems, pressure and force transducers, laboratory instrumentation, biomedical monitoring interfaces, and industrial process-control front ends. In each case, the differential input arrangement rejects common-mode noise present on sensor wiring, while selectable gain reduces the dynamic-range burden placed on downstream converters.

When selecting the gain configuration, verify the maximum differential input signal, input common-mode range, and output swing against the selected supply voltage. Place the amplifier close to the sensor and keep high-gain feedback traces short, because parasitic resistance and capacitance can increase noise and reduce effective bandwidth. Use the manufacturer's offset-nulling guidance rather than adding external nulling circuitry unless the application requires it.

This page combines the AD524CDZ package and performance characteristics with family-level drop-in candidates, comparison parameters, and practical design guidance for instrumentation-amplifier layouts. It also identifies the ceramic-DIP footprint, supply range, gain options, and sourcing information required during component selection.

ドロップイン代替品: AD524CDZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

AD524CD

✅ ドロップイン
Analog Devices
📦 16-lead ceramic DIP (CDIP-16)
Precision monolithic instrumentation amplifier · 1 circuit · 16-lead CDIP · 1, 10, 100, and 1000 · Single-resistor programmable for arbitrary gain · 0.3 V p-p at 10 Hz · 100 dB minimum · 50 uV maximum

価格はお問い合わせください

データシートを見る →

AD524BDZ

✅ ドロップイン
Analog Devices
📦 16-lead ceramic DIP (CDIP-16)
1 circuit · Precision monolithic instrumentation amplifier · 16-lead ceramic DIP · 1, 10, 100, and 1000 · Any gain using one external resistor · Input nulling terminals provided · Output nulling terminals provided · Protected during power-on and power-off conditions

価格はお問い合わせください

データシートを見る →

AD524AD

✅ ドロップイン
Analog Devices
📦 16-lead ceramic DIP (CDIP-16)
Precision monolithic instrumentation amplifier · 1 circuit · 250 µV · 5 V/µs · 1 MHz · ±6 V to ±18 V · 16-lead ceramic DIP · 16 leads

価格はお問い合わせください

データシートを見る →

AD524CDZ 最大定格&電気的特性

Product Type Precision instrumentation amplifier
Number of Amplifier Circuits 1 circuit
パッケージ 16-lead ceramic DIP (CDIP-16)
Maximum Input Offset Voltage 50 uV
Bandwidth Approximately 1 MHz
Slew Rate 5 V/us
Supply Voltage Range +/-6 V to +/-18 V
Pin-Programmable Gains 1, 10, 100, and 1000
External Resistor Gain Programming Supported
Offset Nulling Terminals Input and output offset nulling terminals
Input Overvoltage Protection Protected during power-on and power-off fault conditions
Compensation Built-in
Application Category Precision data acquisition
実装タイプ Through-hole
Suitable Package Options in AD524 Family 16-lead ceramic DIP, 16-lead SBDIP, 16-lead SOIC, and 20-terminal leadless chip carrier

AD524CDZ 16-lead ceramic dip, 16-lead sbdip, 16-lead soic, and 20-terminal leadless chip carrier ピン配置ガイド

AD524CDZ (16-lead ceramic dip, 16-lead sbdip, 16-lead soic, and 20-terminal leadless chip carrier パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

AD524CDZ の 16-lead ceramic dip, 16-lead sbdip, 16-lead soic, and 20-terminal leadless chip carrier パッケージピン配置図

詳細なピン配置データはありません: AD524CDZ.

詳細は データシート をご参照ください。

主な用途

AD524CDZ の用途: 6 件s: Strain-Gauge and Load-Cell Amplification, Precision Pressure and Force Transducers, Industrial Temperature and Process Sensing, Laboratory Instrumentation and Data Acquisition, Biomedical and Physiological Signal Acquisition, Precision Weighing and Metrology Systems.

🏭

Strain-Gauge and Load-Cell Amplification

The AD524CDZ suits strain-gauge bridges and load cells whose useful output is only a few millivolts. Its 50 uV maximum input offset keeps added error small relative to typical bridge sensitivities, while gains of 1, 10, 100, and 1000 allow one analog front end to cover multiple load ranges. The differential input also helps reject common-mode voltage and pickup on sensor wiring. Place the amplifier close to the bridge, keep input loops compact, and verify that the selected supply provides adequate output swing at the chosen gain.

⚡

Precision Pressure and Force Transducers

The AD524CDZ provides the differential gain and low input offset needed for piezoresistive pressure cells and force transducers. A bridge excitation produces a small differential signal over a larger common-mode voltage, which the instrumentation amplifier is designed to reject. Programmable gain lets the designer use 10 or 100 rather than excessive gain that would amplify noise and reduce usable bandwidth. Keep bridge excitation and signal returns together, route the amplifier input differentially, and confirm output swing before fixing the gain-setting jumpers.

🌡️

Industrial Temperature and Process Sensing

The AD524CDZ is appropriate for conditioning resistive temperature sensors, thermocouple interfaces, and other slow industrial process signals. Its approximately 1 MHz bandwidth is well above the signal bandwidth of most temperature loops, while the 5 V/us slew rate supports the device's operating class. The programmable gain structure allows a single amplifier to cover RTD or bridge outputs over a wide measurement range. Use the offset-nulling terminals for precision calibration, and validate the common-mode range against the sensor return and industrial ground architecture.

🧪

Laboratory Instrumentation and Data Acquisition

The AD524CDZ works well as the first analog stage in laboratory measurement systems that acquire low-level differential signals. Its precision architecture combines a 50 uV maximum input offset, selectable gain, and common-mode rejection in one device. The approximately 1 MHz bandwidth is appropriate for general-purpose analog measurement channels rather than high-speed waveform capture. For best results, place the device near the input connector or sensor, use shielded or guarded wiring, and connect the offset-nulling terminals according to the manufacturer calibration procedure.

💊

Biomedical and Physiological Signal Acquisition

The AD524CDZ can serve as the differential input stage for low-level biomedical electrodes and physiological sensors when its supply, common-mode range, and protection requirements match the application. Differential amplification rejects the common-mode interference that is often much larger than the physiological signal, and the programmable gain accommodates widely varying electrode amplitudes. The 50 uV maximum offset is useful when the target signal is small. Medical designs still require separate patient protection, isolation, leakage-current compliance, and application-specific safety validation.

⚖️

Precision Weighing and Metrology Systems

The AD524CDZ is a strong fit for platform scales, laboratory balances, and industrial weighing systems that rely on load-cell bridges. Programmable gains of 1, 10, 100, and 1000 accommodate different load ranges, and the low maximum offset helps preserve resolution at low excitation voltages. Because high-gain measurements magnify thermal drift and parasitic effects, use short shielded input paths and stable gain resistors. Confirm zero drift and offset performance over the full intended temperature range for the selected device grade.

おすすめ製品の概要

AD524CD Same-family CDIP alternative for load-cell front ends 使用用途: Strain-Gauge and Load-Cell Amplification, Industrial Temperature and Process Sensing, Laboratory Instrumentation and Data Acquisition, Precision Weighing and Metrology Systems AD524BDZ Analog Devices 使用用途: Strain-Gauge and Load-Cell Amplification, Industrial Temperature and Process Sensing, Precision Weighing and Metrology Systems AD524AD AD524 family option for transducer conditioning 使用用途: Precision Pressure and Force Transducers, Laboratory Instrumentation and Data Acquisition, Biomedical and Physiological Signal Acquisition AD524CDZ Analog Devices 使用用途: Precision Pressure and Force Transducers, Biomedical and Physiological Signal Acquisition
What is the AD524CDZ?
The AD524CDZ is a precision, single-circuit monolithic instrumentation amplifier from Analog Devices in a 16-lead ceramic DIP package. It is intended for precision data-acquisition systems and provides pin-programmable gains of 1, 10, 100, and 1000, along with external resistor gain programming. According to the Analog Devices AD524 datasheet, the device also includes built-in compensation, input and output offset-nulling terminals, and input protection for power-on and power-off fault conditions.
What are the key specifications of AD524CDZ that engineers should know?
The AD524CDZ combines a maximum input offset voltage of 50 uV, approximately 1 MHz bandwidth, a 5 V/us slew rate, and operation from +/-6 V to +/-18 V. It is a single-circuit instrumentation amplifier in a 16-lead ceramic DIP. The Analog Devices AD524 datasheet identifies programmable gains of 1, 10, 100, and 1000 and describes external resistor-programmed gain, built-in compensation, offset-nulling terminals, and protected inputs as central features for precision sensor measurements.
Where can I download the AD524CDZ datasheet PDF?
The official AD524CDZ datasheet PDF is available from the Analog Devices document at https://www.analog.com/media/en/technical-documentation/data-sheets/AD524.pdf. The manufacturer product page at https://www.analog.com/en/products/ad524.html provides the AD524 family overview, package options, gain configurations, and ordering information. Use the pin-description and connection diagrams in the manufacturer datasheet when assigning PCB tracks, and use the family ordering guide to confirm the CDIP suffix and operating-grade requirements.
Where can I find the AD524CDZ pinout?
The AD524CDZ pinout is shown in the pin-configuration diagram of the official Analog Devices AD524 datasheet at https://www.analog.com/media/en/technical-documentation/data-sheets/AD524.pdf. Because the AD524CDZ is a 16-lead ceramic DIP, its connection diagram also applies to the family documentation for the CDIP package. Use the diagram to identify supply pins, gain-programming connections, input and output offset-nulling terminals, and protected input terminals before laying out the board.
What gain settings does the AD524CDZ support?
The AD524CDZ supports pin-programmable gains of 1, 10, 100, and 1000, and it also accepts an external resistor for other gain values. According to the Analog Devices AD524 product page, the gain-selection structure supports single-resistor programming while retaining the standard discrete gains. Gain selection determines amplification and noise behavior, so choose the lowest gain that places the expected sensor output within the usable output range of the selected supply.
Is the AD524CDZ suitable for bridge and strain-gauge measurements?
Yes, the AD524CDZ is well suited to bridge and strain-gauge measurements because it combines differential input handling with programmable gain and a 50 uV maximum input offset voltage. Its common-mode rejection allows small sensor-generated differential signals to be measured in the presence of larger common-mode voltages. Place the device close to the bridge, use short guarded sensor traces, and confirm that the bridge excitation and output remain inside the AD524 input and output limits described in the manufacturer datasheet.
How does the AD524CDZ differ from the AD524AD?
The AD524AD and AD524CDZ belong to the same AD524 precision instrumentation-amplifier family, but their package and grade ordering options differ. The AD524CDZ is specified as a 16-lead ceramic DIP, while the AD524AD comparison identifies a separate ordering variant. For a board designed specifically around the AD524CDZ ceramic-DIP footprint, use the AD524CD and AD524BDZ candidates with the same CDIP package; confirm the required temperature grade and supplier availability before substitution.
What is the difference between AD524CDZ and AD524CD?
The AD524CDZ and AD524CD are closely related AD524 family devices whose comparison centers on their package and grade ordering differences. The AD524CDZ is identified as a 16-lead ceramic DIP, and the AD524CD is the related DIP-format ordering option considered against the CDZ variant. Both use the same family gain and protection architecture, but the exact suffix controls package and temperature-grade selection, so confirm those requirements against the AD524 ordering table before treating one as a drop-in replacement.
What is the best drop-in replacement for AD524CDZ?
The AD524CD and AD524BDZ are the closest same-family ceramic-DIP drop-in candidates identified for the AD524CDZ because they use the same 16-lead CDIP outline and instrumentation-amplifier architecture. The AD524AD is also a family alternative, although its exact package ordering differs. Verify pin assignment, temperature grade, gain configuration, and offset-nulling usage in the manufacturer datasheet before substituting. Use the Request a Quote form on this page to request availability of the required suffix.
Can an AD524CDZ replace a similar instrumentation amplifier on an existing PCB?
The AD524CDZ can replace a compatible 16-lead ceramic-DIP instrumentation amplifier only when the substitute has the same pin assignments, supply range, gain-programming method, and electrical performance. The AD524CD and AD524BDZ are the most direct candidates in the AD524 family, while the AD524AD must be checked more carefully for package differences. Verify the footprint and every connection against the manufacturer pin-configuration diagram rather than relying on package name alone.
When should I choose the AD524CDZ over another AD524 variant?
Choose the AD524CDZ when the design specifically requires a precision instrumentation amplifier in a 16-lead ceramic DIP and benefits from the AD524 family's programmable gains of 1, 10, 100, and 1000. Select a different package option when board area or assembly method is more important than the ceramic-DIP footprint. The AD524 family also includes 16-lead SBDIP, 16-lead SOIC, and 20-terminal leadless chip-carrier versions, which require different PCB land patterns.
Is the AD524CDZ suitable for industrial process-control front ends?
Yes, the AD524CDZ is suitable for industrial process-control front ends that require accurate measurement of low-level differential sensor signals. Its 50 uV maximum offset voltage, approximately 1 MHz bandwidth, programmable gain, and protected inputs support conditioning for pressure, temperature, force, and bridge-transducer outputs. The through-hole ceramic DIP is also mechanically practical for higher-temperature assemblies, subject to the device's specified operating-temperature grade.
What can replace the AD524CDZ?
The AD524CD and AD524BDZ are the closest documented replacements for the AD524CDZ because they are AD524 family devices offered in the same 16-lead ceramic-DIP format and preserve the instrumentation-amplifier gain architecture. The AD524AD is another family option but requires confirmation of package and grade differences. No cross-brand drop-in part is established by the manufacturer information, so use these same-family choices for footprint-compatible substitution and verify the ordering table before purchasing.
Is the AD524CDZ the same as the AD624CDZ?
No. The AD524CDZ and AD624CDZ are different Analog Devices instrumentation amplifiers, and a substitution should not be assumed without a detailed circuit review. The AD524CDZ belongs to the AD524 family, which offers pin-programmable gains of 1, 10, 100, and 1000 and external resistor gain programming. The AD624CDZ appears in a separate comparison listing, so confirm its pinout, gain method, supply range, bandwidth, and common-mode limits against the original design.
Where can I buy AD524CDZ online and what is the lead time?
Use the Request a Quote form on this page to request AD524CDZ pricing, stock, minimum order quantity, and current lead time from XAIPART. The AD524CDZ is listed as a 16-CDIP precision instrumentation amplifier by authorized distribution channels, but inventory and delivery schedules change continuously. Provide the required quantity, grade, and target date with the request so procurement can confirm the exact AD524CDZ ordering code rather than a family-level or alternate package variant.

エンジニアリング参考データ: AD524CDZ — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the AD524CDZ when the PCB is designed around a 16-lead ceramic-DIP instrumentation amplifier and the application requires precise differential measurement with programmable gain. It is particularly appropriate for load cells, strain gauges, pressure cells, and other sensors whose millivolt-level outputs need gain selection and common-mode rejection. AD524CD and AD524BDZ are the closest family drop-in candidates because they preserve the CDIP-16 outline, but confirm their grade-specific electrical limits before substitution. AD524AD is another same-family option whose package and ordering requirements should be checked against the original design. Choose a different AD524 package option when board area, automated assembly, or thermal-mechanical requirements make a ceramic through-hole DIP unsuitable. Do not substitute the AD624CDZ solely because both are Analog Devices instrumentation amplifiers; verify pinout, gain method, supply range, bandwidth, and common-mode limits.

代替品との比較

パラメータ この製品 AD524CD AD524BDZ AD524AD
Package 16-lead ceramic DIP (CDIP-16) 16-lead ceramic DIP (CDIP-16) 16-lead ceramic DIP (CDIP-16) 16-lead ceramic DIP (CDIP-16)
Brand Analog Devices Analog Devices Analog Devices Analog Devices
Product Type Precision instrumentation amplifier Precision instrumentation amplifier Precision instrumentation amplifier Precision instrumentation amplifier
Amplifier Circuits 1 circuit 1 circuit 1 circuit 1 circuit

主な差別化要因

  • Direct family replacement path for a ceramic-DIP footprint (vs AD524CD)
  • Multiple gain settings without changing the analog board (vs AD524AD)
  • Low offset suited to millivolt-level sensor outputs (vs AD524BDZ)

設計ノート

Route the two differential inputs as a compact pair directly from the sensor or bridge to the AD524CDZ input pins. Avoid long unshielded runs that can pickup mains-related interference, especially at gains of 100 and 1000. Keep the gain-programming connections away from high-current switching nodes and analog return paths. For stable measurements, place the amplifier close to the sensor and use a ground plane that does not carry motor, relay, or switching-converter return currents.

Check output headroom whenever the gain is increased because instrumentation-amplifier gain multiplies the differential input while the output remains limited by the supply rails. The device operates from +/-6 V to +/-18 V, but usable signal swing is narrower than the nominal supply range. Include worst-case sensor offset, bridge imbalance, and input noise when selecting the gain. Use clean, low-impedance supply connections because supply disturbances can couple into high-gain measurements.

Do not treat every AD524 suffix as automatically interchangeable. The AD524CDZ identifies a specific 16-lead ceramic-DIP ordering option, while other suffixes can change the package or temperature grade. Before substitution, compare the AD524 ordering table, pin-configuration diagram, electrical characteristics, and gain-setting method. Also verify how the offset-nulling terminals are used, because external components placed on those terminals can affect offset performance and stability.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not confirmed for the AD524CDZ. AEC-Q100 is not applicable because the AD524 is an Analog Devices instrumentation amplifier rather than an automotive-qualified device.

データ検証日: 2026-11-18 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

AD524CDZ datasheet AD524CDZ datasheet pdf AD524CDZ pinout AD524CDZ 16-CDIP AD524CDZ instrumentation amplifier AD524CDZ equivalent AD524CDZ replacement AD524CDZ cross reference AD524CDZ vs AD524CD AD524CDZ vs AD524BDZ Analog Devices AD524CDZ AD524 precision instrumentation amplifier AD524CDZ load cell amplifier AD524CDZ price AD524CDZ stock

関連部品&用語

Analog Devices AD524CDZ AD524 AD524CD AD524BDZ AD524AD AD624CDZ instrumentation amplifier differential amplifier operational amplifier analog signal-chain IC data acquisition precision measurement pin-programmable gain offset nulling bridge transducer strain gauge load cell RTD common-mode rejection CDIP-16 ceramic DIP through-hole mounting input overvoltage protection
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示