AD629BR - ±270V Difference Amplifier | Analog Devices
部品番号: AD629BR ✓ 生産中AD629BR 概要
A difference amplifier is a specialized analog amplifier that subtracts two input voltages and rejects a voltage common to both inputs. The AD629 belongs to the instrumentation and difference-amplifier hierarchy within analog signal-chain ICs, where precision gain, common-mode rejection, input protection, and reference handling determine measurement quality. In a current-sense application, a small shunt voltage is measured while the amplifier tolerates the much larger supply voltage appearing across the shunt.
The AD629BR supports common-mode inputs up to ±270 V, providing the central feature for high-side current measurement. Its precision difference-amplifier architecture measures differential voltage rather than requiring the input signal to be referenced near ground. Analog Devices identifies the AD629 as a production device, and its product materials include application guidance for measuring −48 V high-side current. The manufacturer also documents ways to optimize difference-amplifier performance, including correct handling of the reference terminals.
The AD629 uses internal resistors to establish a difference-amplifier configuration. For unity gain, the manufacturer datasheet directs engineers to ground pins 1 and 5, designated REF(−) and REF(+), and connect them to the same low-impedance ground plane. This connection is important because an unbalanced or high-impedance reference network can degrade common-mode rejection. Component selection and resistor matching around the input and reference paths should therefore follow the manufacturer’s recommended topology.
Typical uses include high-side current sensing in industrial and communications power systems, battery-pack monitoring, motor-control systems, power-supply diagnostics, and instrumentation where a small differential voltage appears on a high-voltage rail. The AD629 can also support measurement designs where an isolation amplifier would otherwise be considered. Any replacement should be checked against the actual common-mode range, gain accuracy, reference configuration, supply requirements, bandwidth, and package pinout rather than selected from the device description alone.
When laying out a circuit, prioritize low-impedance reference routing and place input and feedback components close to the relevant terminals. Verify the source and sink voltage limits for the intended bus, include adequate protection for transients and sustained overvoltage, and account for input and output common-mode behavior across temperature. The high common-mode capability does not remove the need for a correctly scaled shunt and protected system architecture.
This product page combines the AD629BR’s high-voltage measurement role with practical comparison criteria, reference-pin guidance, and application-oriented design notes. It helps engineers evaluate the device for precision current sensing while keeping the distinction between a true pin-compatible replacement and a merely similar high-voltage amplifier explicit.
ドロップイン代替品: AD629BR — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AD629BR (同一形状・フットプリント) — 相違点: Package, Operating Temperature Range, Mounting Type, Product Type, Common-Mode Input Voltage Range.
AD629ARZ-R7
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD629BN
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD629BNZ
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD629BRZ
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD629BR 最大定格&電気的特性
| Product Type | Precision difference amplifier |
| Maximum Common-Mode Voltage | ±270 V |
| Number of Circuits | 1 circuit |
| パッケージ | 8-pin SOIC |
| Input Reference Pins | Pin 1: REF(−); Pin 5: REF(+) |
| Unity-Gain Reference Configuration | Ground pins 1 and 5 to the same low-impedance ground plane |
| 実装タイプ | Surface mount |
| Production Status | PRODUCTION |
| Gain | Unity gain for the documented REF connection |
AD629BR 8-pin soic ピン配置ガイド
AD629BR (8-pin soic パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD629BR.
詳細は データシート をご参照ください。
主な用途
AD629BR の用途: 6 件s: High-Side Industrial Current Sensing, 48 V Communications Power Monitoring, Battery-Pack Monitoring, Motor Drive DC-Link Diagnostics, Power-Supply Output Current Measurement, Precision Instrumentation and Test Equipment.
High-Side Industrial Current Sensing
The AD629BR fits high-side current measurement because it extracts the small differential voltage produced by a shunt while tolerating common-mode voltages up to ±270 V. Place the amplifier across the shunt and connect REF(−) on pin 1 and REF(+) on pin 5 to the same low-impedance ground plane for unity gain. This arrangement preserves the shunt measurement instead of first attenuating a high bus voltage. The principal design trade-off is that high-side sensing places the amplifier close to large switching transients, so input protection, trace spacing, and connector surge control remain essential. AD8603, AD780, and AD7453 are identified by Analog Devices in its −48 V high-side current application reference.
おすすめ
48 V Communications Power Monitoring
The AD629BR is appropriate for monitoring a −48 V communications rail because its common-mode input capability extends to ±270 V and the measured shunt signal can be substantially smaller than the bus voltage. The amplifier provides the differential extraction function while the shunt sets the measurable current range and power dissipation. For a negative rail, verify input and output polarity in the manufacturer circuit, select resistor and protection parts for the actual voltage, and use a single low-impedance reference plane to preserve common-mode rejection. The approach can produce a compact current-monitor signal for an ADC or controller without bringing the full supply voltage into the sensitive measurement node.
おすすめ
Battery-Pack Monitoring
The AD629BR can measure differential voltages in battery systems where the common-mode voltage is much larger than the signal developed across a current shunt. Its ±270 V common-mode range provides margin for multi-cell industrial battery buses, while the precision difference-amplifier function isolates the useful shunt voltage. Designers should select the shunt for the maximum discharge current, verify that charger transients remain within the amplifier’s ratings, and include protection that does not distort the measurement bandwidth. The unity-gain connection grounds both reference terminals to the same low-impedance plane, an important requirement for maintaining common-mode rejection in compact battery-monitoring assemblies.
おすすめ
Motor Drive DC-Link Diagnostics
The AD629BR is useful in motor-control systems that require measurement of a small differential voltage on a high DC-link or battery input. By accepting a common-mode voltage up to ±270 V, it can preserve the precision of a shunt measurement without requiring the signal to be shifted to ground first. The design must account for PWM-related spikes, switching-node transients, and the temperature rise of the shunt. Place protection close to the amplifier pins, route the differential sense pair as a compact pair, and ground the reference pins as directed by Analog Devices. This makes the AD629BR appropriate for supervisory current detection, fault diagnostics, and thermal-management feedback.
おすすめ
Power-Supply Output Current Measurement
The AD629BR can monitor output current in high-voltage power supplies by measuring the differential voltage across a series shunt. Its common-mode capability is valuable when the output bus sits far above ground, and the dedicated difference-amplifier configuration avoids measuring the full supply voltage. The shunt must be sized for both continuous current and pulse load, while the amplifier’s gain accuracy and temperature behavior determine the overall measurement uncertainty. Input filtering should reject switching ripple without adding excessive delay, and the reference planes should remain low impedance to maintain common-mode rejection. The resulting monitor signal can feed a controller, comparator, or precision ADC for overload detection.
おすすめ
Precision Instrumentation and Test Equipment
The AD629BR supports laboratory and industrial instrumentation that must measure a low-level differential signal over a large common-mode range. The ±270 V input capability can reduce the need for a separate attenuator when the source remains within the amplifier’s limits. For instrument-grade performance, evaluate offset error, gain drift, bandwidth, and common-mode rejection at the actual signal frequency and temperature. The reference terminals must connect to the same low-impedance ground plane to avoid degraded rejection. Analog Devices application note AN-589 provides additional guidance on optimizing difference-amplifier performance when precision measurement behavior is the main design concern.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD629BR — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD629ARZ | AD629BN | AD629BNZ | AD629BRZ |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Product Function | Precision difference amplifier | Precision difference amplifier | AD629-family difference amplifier | AD629-family difference amplifier | Precision difference amplifier |
| Maximum Common-Mode Voltage | ±270 V | ±270 V | ±270 V | ±270 V | ±270 V |
| Circuit Count | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Pinout Compatibility | AD629 8-SOIC pinout | Same pinout as AD629BR | AD629-family 8-SOIC footprint | AD629-family 8-SOIC footprint | Same core specifications and pinout |
| Gain and Offset Grade | BR grade with tighter gain and offset specifications | Standard grade with less stringent gain and offset specifications | BN grade; exact limits require datasheet review | BN grade; exact limits require datasheet review | BR-family accuracy; exact ordering-code limits require review |
| Primary Application | High-side current sensing and differential measurement | High-side current sensing | AD629-family high common-mode measurement | AD629-family high common-mode measurement | High-side current sensing |
主な差別化要因
- Higher-grade DC accuracy within the same AD629 family (vs AD629ARZ)
- Direct same-footprint family replacement (vs AD629BRZ)
- No separate high-voltage attenuation stage is required for qualifying bus levels (vs AD629BN)
設計ノート
For unity gain, ground pins 1 and 5, identified by Analog Devices as REF(−) and REF(+), and connect both to the same low-impedance ground plane. The manufacturer states that failure to do this degrades common-mode rejection. Do not route either reference through a long trace, connector, or high-impedance protection element that could create a voltage difference between the two reference nodes.
Route the differential input pair as a compact, tightly coupled pair and keep it away from switching nodes and high-current return paths. Place the shunt or input-network components close enough to the amplifier that parasitic inductance does not convert switching-edge current into voltage across the sensitive measurement input. Input protection must suppress bus transients without compromising the bandwidth, common-mode range, or accuracy required by the measurement.
Estimated: the shunt dissipates P = I²R. For a 100 A measurement current and a 1 mΩ shunt, the estimated shunt dissipation is 10 W, requiring suitable shunt packaging and copper area. This calculation is independent of amplifier power and demonstrates why a low-value shunt can still become a thermal component in high-current systems.
Treat the reference connection as a sensitive analog node. Use a continuous ground region, avoid placing digital return current beneath the input or reference paths, and verify the assembled board for unintended reference voltage differences. The application-note guidance for optimizing difference amplifiers is particularly relevant when common-mode rejection, rather than only nominal gain, determines the accuracy of the current measurement.
コンプライアンス情報
Compliance status is not established by the retrieved manufacturer and distributor excerpts. The AD629BR is an analog instrumentation amplifier rather than an automotive-qualified device.