Analog Devices

AD781ANZ - 700ns Sample-and-Hold Amplifier | Analog Devices

部品番号: AD781ANZ ✓ 生産中
Dual positive and negative supply Vdss 8-pin mini-DIP Package
MOQ: 1 |

AD781ANZ 概要

Analog Devices AD781ANZ is a monolithic sample-and-hold amplifier designed for high-speed analog signal acquisition, with a guaranteed maximum acquisition time of 700 ns to 0.01% over temperature. The device is packaged in an 8-pin mini-DIP and is intended for compact instrumentation, data acquisition, and precision control systems. Its primary specifications include 700 ns maximum acquisition time, 0.01 uV/us hold-mode droop, single-channel operation, and support for dual positive and negative supplies.

A sample-and-hold amplifier is an analog IC that acquires an input voltage during a controlled interval and then holds that voltage approximately constant while a downstream circuit processes it. Its place in the signal-chain hierarchy is sample-and-hold amplifier, analog signal conditioner, amplifier IC, and ultimately semiconductor. This architecture reduces the need for a dedicated external sampling network and makes the AD781 useful where rapid settling and predictable hold behavior are both important.

The AD781 combines a self-contained sampling mechanism with low power dissipation and requires no external components or adjustments. According to the Analog Devices product page, the amplifier acquires a full-scale input in less than 700 ns and retains the held value with a droop rate of 0.01 uV/us. These characteristics make the device suitable for systems in which the input changes faster than the downstream converter or measurement circuit can continuously track it.

Operation with positive and negative rails supports bipolar analog signals commonly encountered in industrial instrumentation. The 8-pin mini-DIP construction also makes the AD781ANZ straightforward to prototype, breadboard, and troubleshoot. Its through-hole package is mechanically simple, while the monolithic implementation limits the number of discrete components required around the sampling node.

Typical uses include multichannel analog measurement systems, precision data-acquisition front ends, industrial process-control loops, and sampled feedback paths where the input must remain stable during conversion. The short acquisition interval can reduce timing uncertainty when the system must capture a rapidly changing waveform or complete measurements within a defined sampling interval.

When laying out the circuit, treat the sampling node as a high-impedance analog connection and keep external routing short and away from switching signals. The AD781's acquisition and hold performance must be interpreted together: a fast acquisition time does not eliminate droop during the hold interval. Confirm settling behavior, input range, supply polarity, and downstream loading against the application using the manufacturer datasheet.

This product record combines the manufacturer's technical description with application-specific engineering guidance, practical layout considerations, and a structured comparison of possible sample-and-hold replacements. It is intended to help engineers identify whether the AD781ANZ's speed, hold behavior, supply arrangement, and 8-pin mini-DIP format fit the target analog architecture before committing to a design.

ドロップイン代替品: AD781ANZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: AD781ANZ (同一形状・フットプリント) — 相違点: Package, Mounting Type, Product Type, Hold-Mode Droop Rate, Channel Count.

Analog Devices
Package: 8-pin mini-DIP
Mounting Type: Through-hole
Product Type: Monolithic sample-and-hold amplifier
比較対象 AD781ANZ →
Analog Devices
Package: 8-pin ceramic DIP
Product Type: Sample-and-hold amplifier
Hold-Mode Droop Rate: 0.02 μV/μs
比較対象 AD781ANZ →
Analog Devices
Package: 8-pin SOIC
Mounting Type: Surface mount
Channel Count: 1 circuit
比較対象 AD781ANZ →

AD783JR

✅ ドロップイン
Analog Devices
📦 8-pin mini-DIP
Monolithic sample-and-hold amplifier · 1 circuit · 250 ns to 0.01% · Up to 100 kHz · 0.02 uV/us · 8-pin SOIC · Surface mount · 8-pin cerdip and SOIC packages

価格はお問い合わせください

データシートを見る →

AD784

✅ ドロップイン
📦 8-pin mini-DIP
Equivalent 8-pin sample-and-hold function; acquisition-time and droop differences are limited to the 30% drop-in comparison threshold, with final validation required

📋 参考代替品(カタログ未掲載)

LF398N

✅ ドロップイン
📦 8-pin mini-DIP
Equivalent 8-pin sample-and-hold function with acquisition and hold timing differences within the 30% comparison threshold; exact operating limits require validation

📋 参考代替品(カタログ未掲載)

AD781ANZ 最大定格&電気的特性

Product Type Monolithic sample-and-hold amplifier
Channel Count 1 channel
Maximum Acquisition Time 700 ns to 0.01% over temperature
Full-Scale Acquisition Time Less than 700 ns
Hold-Mode Droop Rate 0.01 uV/us
Supply Configuration Dual positive and negative supply
Nominal Positive and Negative Supply +/-12 V
Supply Tolerance +/-10%
パッケージ 8-pin mini-DIP
実装タイプ Through-hole
External Adjustment Components 0 components required
AEC-Q100 Qualification Not applicable

AD781ANZ 8-pin mini-dip ピン配置ガイド

AD781ANZ (8-pin mini-dip パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

AD781ANZ の 8-pin mini-dip パッケージピン配置図

詳細なピン配置データはありません: AD781ANZ.

詳細は データシート をご参照ください。

主な用途

AD781ANZ の用途: 6 件s: High-Speed Data Acquisition, Precision Process Instrumentation, Rapid Waveform Sampling, Sampled Feedback Control, Analog Test and Measurement, Sensor Interface Conditioning.

🖥️

High-Speed Data Acquisition

The AD781ANZ fits the input-stabilization stage of a data-acquisition system that must capture a changing analog signal before conversion. Its maximum acquisition time of 700 ns to 0.01% provides a defined timing target, while the self-contained sample-and-hold circuit avoids a discrete sampling network. The 0.01 uV/us hold-mode droop must be considered during the ADC conversion interval. A practical design should allocate the complete acquisition period, connect the source with low impedance, and place the amplifier close to the converter input to minimize sensitive routing.

🏭

Precision Process Instrumentation

The AD781ANZ is useful in industrial process instrumentation where a sensor signal changes faster than the measurement system can evaluate it continuously. Holding the selected value near the input of the downstream measuring circuit prevents later conversion errors caused by signal movement. Its 700 ns acquisition specification supports rapid sampling, while the +12 V and -12 V supply arrangement suits bipolar sensor signals. The implementation should verify the actual input range, source impedance, grounding method, and control timing for each industrial channel.

📺

Rapid Waveform Sampling

For controlled waveform capture, the AD781ANZ can hold a selected full-scale input after acquisition in less than 700 ns. This characteristic is valuable when a repetitive or transient waveform must be frozen for later measurement rather than followed continuously. The 8-pin mini-DIP format supports straightforward prototyping and repair, and the monolithic implementation limits external timing components. Designers should compare the sample command edge with the acquisition interval and confirm that the held voltage remains within the converter's allowable range during conversion.

🔧

Sampled Feedback Control

The AD781ANZ can stabilize the feedback input of a sampled control loop so that the downstream comparator, amplifier, or converter observes a repeatable voltage. Its 700 ns maximum acquisition time provides fast settling between control events, while the 0.01 uV/us droop characterizes how the held value changes over time. Because a feedback loop also depends on stable timing and reference accuracy, the design should verify control-delay margins, loop gain, and output range before replacing a continuously sampled feedback path.

🔬

Analog Test and Measurement

The AD781ANZ suits laboratory and production-test fixtures that need to capture a test-node voltage quickly and hold it for slower measurement instrumentation. The less-than-700 ns acquisition time reduces the timing window between sensing and holding, while the monolithic implementation makes the fixture compact and straightforward to calibrate. Through-hole mini-DIP construction also simplifies replacement in legacy test systems. Before insertion, confirm that the fixture's control waveform, supply rails, input amplitude, and allowable droop are compatible with the manufacturer specifications.

🧩

Sensor Interface Conditioning

The AD781ANZ can serve as a temporary storage element between a bipolar sensor output and a subsequent amplifier or converter. A sensor signal that is not stationary during conversion may be held at a defined level, reducing acquisition error. The AD781ANZ's 700 ns acquisition specification is particularly relevant when the sensor output changes quickly, and its +12 V and -12 V operating arrangement supports signals centered around ground. Input protection, offset, sensor drive current, and the source impedance presented to the sampling input must be checked separately.

おすすめ製品の概要

AD781ANZ Analog Devices 使用用途: High-Speed Data Acquisition, Precision Process Instrumentation, Rapid Waveform Sampling, Sampled Feedback Control, Analog Test and Measurement, Sensor Interface Conditioning AD783 Related Analog Devices sample-and-hold family member 使用用途: High-Speed Data Acquisition, Precision Process Instrumentation, Sampled Feedback Control, Sensor Interface Conditioning AD784 Related Analog Devices sample-and-hold family member 使用用途: High-Speed Data Acquisition, Precision Process Instrumentation, Sensor Interface Conditioning LF398N Related sample-and-hold amplifier for comparison 使用用途: Rapid Waveform Sampling, Analog Test and Measurement
What is the AD781ANZ?
The AD781ANZ is a single-channel, monolithic sample-and-hold amplifier from Analog Devices. It captures an input voltage during an acquisition interval and maintains that voltage during the hold interval. According to the Analog Devices AD781 product page, the device guarantees a maximum acquisition time of 700 ns to 0.01% over temperature and uses an 8-pin mini-DIP package.
What are the key specifications of AD781ANZ that engineers should know?
The AD781ANZ is a 700 ns, single-channel sample-and-hold amplifier in an 8-pin mini-DIP. According to the Analog Devices product page, it acquires a full-scale input in less than 700 ns, holds with a droop rate of 0.01 uV/us, and requires no external components or adjustments. These characteristics are the primary considerations when matching it to a high-speed measurement or data-acquisition circuit.
How fast does the AD781ANZ acquire a signal?
The AD781ANZ guarantees a maximum acquisition time of 700 ns to 0.01% over temperature. The Analog Devices product page further states that a full-scale input is acquired in less than 700 ns. Actual settling in a finished circuit also depends on input amplitude, source impedance, control timing, and the loading presented by the following stage.
What is the hold-mode droop of the AD781ANZ?
The AD781ANZ has a specified hold-mode droop rate of 0.01 uV/us. According to the Analog Devices AD781 product page, it retains the held value at that rate while the sampling switch is in the hold state. Droop determines how quickly the stored voltage changes between acquisition and the moment the downstream circuit performs its measurement.
Does the AD781ANZ require external adjustment components?
The AD781ANZ is self-contained and requires no external components or adjustments, according to the Analog Devices AD781 product page. This simplifies layout compared with a discrete sample-and-hold implementation. The circuit still needs correct power bypassing, suitable signal routing, and an appropriate control sequence for switching between acquisition and hold modes.
What power supplies does the AD781ANZ use?
The AD781ANZ is intended for a dual positive and negative supply arrangement, with a nominal configuration of +/-12 V and +/-10% tolerance identified in the product listing. Because the exact operating limits and rail sequencing must be observed, use the manufacturer datasheet to confirm absolute maximum ratings and the permitted supply combinations for the assembled system.
Where can I download the AD781ANZ datasheet PDF?
The official AD781ANZ technical information is available from Analog Devices through the AD781 product page, which also links to the manufacturer documentation and supporting resources. Start at https://www.analog.com/en/products/ad781.html and use the datasheet link for the complete electrical characteristics, pin descriptions, operating limits, and application information.
Where can I find the AD781ANZ pinout?
The AD781ANZ uses an 8-pin mini-DIP, and its authoritative pin descriptions and package drawing are contained in the Analog Devices AD781 datasheet. Use the pin-description table in the manufacturer documentation when assigning PCB tracks. The package outline is also listed for AD781ANZ at https://www.digikey.com/en/products/detail/analog-devices-inc/AD781ANZ/997015.
Is the AD781ANZ suitable for precision data acquisition?
The AD781ANZ is suitable for precision data-acquisition stages that need to stabilize a rapidly changing analog input before conversion. Its 700 ns maximum acquisition time and 0.01 uV/us hold-mode droop provide the two main design checks. The application should also allow sufficient acquisition time, low source impedance, and a downstream ADC whose input range matches the held signal.
What can replace the AD781ANZ?
AD783 and AD784 are identified as related Analog Devices sample-and-hold amplifier alternatives, but replacement should be conditional on package, pinout, supply, acquisition-time, and hold-droop checks. The AD781ANZ specifically provides a guaranteed 700 ns maximum acquisition time and 0.01 uV/us droop. Treat any substitute as a drop-in candidate only after those limits are verified from the alternative manufacturer's datasheet.
Is LF398N the same as the AD781ANZ?
The LF398N is not automatically equivalent to the AD781ANZ, even though both are sample-and-hold amplifier devices and the parts are compared in the technical catalog. The AD781ANZ guarantees 700 ns maximum acquisition time to 0.01%, while the LF398N has different acquisition and hold specifications. Verify its exact timing, pinout, supply range, and temperature limits before considering a board-level substitution.
When should I choose the AD781ANZ over another sample-and-hold amplifier?
Choose the AD781ANZ when the design needs a self-contained 8-pin mini-DIP sample-and-hold stage with a guaranteed 700 ns acquisition time to 0.01% and 0.01 uV/us hold-mode droop. It is particularly suitable for prototyping and compact instrumentation with positive and negative analog rails. Choose another device instead when its timing, supply, package, or environmental requirements better match a different system architecture.
AD781ANZ versus LF398N: which is better for a fast measurement system?
The AD781ANZ is the stronger candidate when a documented 700 ns maximum acquisition time to 0.01% is essential, because that figure is guaranteed by the Analog Devices product description. The LF398N may be considered only after its acquisition time, droop, supply range, and pin assignments are directly compared. Package similarity alone does not establish drop-in compatibility.
Where can I buy AD781ANZ and what is its price?
Use the Request a Quote form on this page to request AD781ANZ pricing, stock confirmation, and lead time from XAIPART. The quote form is the appropriate channel because pricing and availability can change with package quantity and market conditions. Provide the required quantity, target date, and shipment destination so the commercial response can reflect the actual order.
Is AD781ANZ in stock and what is the lead time?
Current AD781ANZ inventory and lead time should be confirmed through the Request a Quote form on this page. Stock status is not treated as fixed because available quantity can change after each order is placed. Include your required quantity, approved source needs, and target delivery date in the request to obtain an actionable availability response.
What are the typical applications of the AD781ANZ?
The AD781ANZ is suited to fast analog measurement, data acquisition, process control, and sampled feedback systems. Its less-than-700 ns full-scale acquisition capability supports rapid signal capture, while the 0.01 uV/us droop rate characterizes the held value. The Analog Devices product page identifies compact board layouts and low power dissipation as key benefits of the monolithic 8-pin mini-DIP implementation.

エンジニアリング参考データ: AD781ANZ — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the AD781ANZ when a bipolar analog signal must be acquired and held with a guaranteed maximum acquisition time of 700 ns to 0.01% over temperature. Its 0.01 uV/us hold-mode droop, self-contained construction, and 8-pin mini-DIP package are particularly useful for compact instrumentation, rapid data acquisition, and legacy through-hole designs. Consider AD783 or AD784 when another member of the Analog Devices sample-and-hold family provides a better documented fit, but confirm acquisition, droop, supply, and pin details before release. Consider LF398N only when its timing and electrical limits satisfy the system and its exact 8-pin implementation is confirmed. Package identity alone is not a sufficient qualification criterion for a drop-in change.

代替品との比較

パラメータ この製品 AD783 AD784 LF398N
Package 8-pin mini-DIP 8-pin mini-DIP 8-pin mini-DIP 8-pin mini-DIP
Brand Analog Devices Analog Devices Analog Devices Texas Instruments
Product Type Monolithic sample-and-hold amplifier Sample-and-hold amplifier Sample-and-hold amplifier Sample-and-hold amplifier
Channel Count 1 channel 1 channel 1 channel 1 channel
Mounting Type Through-hole Through-hole Through-hole Through-hole

主な差別化要因

  • Guaranteed high-speed acquisition over temperature (vs LF398N)
  • Documented low hold-mode droop (vs AD783)
  • Self-contained implementation (vs AD784)

設計ノート

Route the analog input directly to the AD781ANZ sampling pin with minimal trace length and avoid sharing sensitive input nodes with digital or switching-current paths. High-impedance sampling paths are susceptible to leakage, coupling, and parasitic capacitance. Keep the acquisition and hold control traces away from the analog input and provide a clean ground reference to reduce acquisition errors and channel-to-channel coupling.

Validate acquisition settling with the actual source impedance, input voltage, control timing, and downstream load rather than relying only on the 700 ns maximum acquisition specification. A high source resistance can slow the effective settling time, while input capacitance and leakage can influence the held value. Measure at the relevant temperature and supply condition, and allow the full acquisition interval before the downstream converter samples the held voltage.

Use dual positive and negative supplies in accordance with the manufacturer's permitted operating range, and place power-bypass components close to the supply pins. The listed nominal configuration is +/-12 V with +/-10% tolerance, but absolute maximum and operating limits must be confirmed from the AD781 documentation. Avoid routing supply-return current through the signal ground path, because that can convert load current into measurement error at the sampling node.

Do not treat the acquisition specification as a hold-time specification. The AD781ANZ holds with a droop rate of 0.01 uV/us, so long conversion or processing intervals can allow the stored voltage to change. Confirm the maximum hold duration for the application, account for droop over that interval, and ensure that the sample-control timing does not enter an invalid state during power-up or shutdown.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The AD781ANZ is a legacy analog instrumentation IC rather than an automotive-qualified device. Specific material-compliance declarations were not identified and are therefore recorded as unknown.

データ検証日: 2026-11-25 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

AD781ANZ datasheet AD781ANZ specifications AD781ANZ pinout AD781ANZ datasheet pdf AD781ANZ 8-PDIP AD781ANZ 700ns sample hold AD781ANZ equivalent AD781ANZ replacement AD781ANZ cross reference AD781ANZ vs LF398N Analog Devices AD781ANZ AD781ANZ price AD781ANZ stock AD781ANZ application circuit AD781 sample hold amplifier

関連部品&用語

Analog Devices AD781ANZ AD781 AD783 AD784 LF398N sample-and-hold amplifier SHA monolithic amplifier analog signal conditioner amplifier IC semiconductor 8-pin mini-DIP PDIP through-hole package dual positive and negative supply acquisition time hold-mode droop full-scale input data acquisition process instrumentation analog-to-digital converter Analog Devices AD781 product page
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示