AD781ANZ - 700ns Sample-and-Hold Amplifier | Analog Devices
N.º de pieza: AD781ANZ ✓ ActivoAD781ANZ Descripción general
A sample-and-hold amplifier is an analog IC that acquires an input voltage during a controlled interval and then holds that voltage approximately constant while a downstream circuit processes it. Its place in the signal-chain hierarchy is sample-and-hold amplifier, analog signal conditioner, amplifier IC, and ultimately semiconductor. This architecture reduces the need for a dedicated external sampling network and makes the AD781 useful where rapid settling and predictable hold behavior are both important.
The AD781 combines a self-contained sampling mechanism with low power dissipation and requires no external components or adjustments. According to the Analog Devices product page, the amplifier acquires a full-scale input in less than 700 ns and retains the held value with a droop rate of 0.01 uV/us. These characteristics make the device suitable for systems in which the input changes faster than the downstream converter or measurement circuit can continuously track it.
Operation with positive and negative rails supports bipolar analog signals commonly encountered in industrial instrumentation. The 8-pin mini-DIP construction also makes the AD781ANZ straightforward to prototype, breadboard, and troubleshoot. Its through-hole package is mechanically simple, while the monolithic implementation limits the number of discrete components required around the sampling node.
Typical uses include multichannel analog measurement systems, precision data-acquisition front ends, industrial process-control loops, and sampled feedback paths where the input must remain stable during conversion. The short acquisition interval can reduce timing uncertainty when the system must capture a rapidly changing waveform or complete measurements within a defined sampling interval.
When laying out the circuit, treat the sampling node as a high-impedance analog connection and keep external routing short and away from switching signals. The AD781's acquisition and hold performance must be interpreted together: a fast acquisition time does not eliminate droop during the hold interval. Confirm settling behavior, input range, supply polarity, and downstream loading against the application using the manufacturer datasheet.
This product record combines the manufacturer's technical description with application-specific engineering guidance, practical layout considerations, and a structured comparison of possible sample-and-hold replacements. It is intended to help engineers identify whether the AD781ANZ's speed, hold behavior, supply arrangement, and 8-pin mini-DIP format fit the target analog architecture before committing to a design.
Alternativas directas para AD781ANZ — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con AD781ANZ (mismo factor de forma y huella) — difiere en Package, Mounting Type, Product Type, Hold-Mode Droop Rate, Channel Count.
AD783JR
✅ Sustitución directaConsulte el precio
Ver hoja de datos →AD784
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
LF398N
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
AD781ANZ Valores máximos y características eléctricas
| Product Type | Monolithic sample-and-hold amplifier |
| Channel Count | 1 channel |
| Maximum Acquisition Time | 700 ns to 0.01% over temperature |
| Full-Scale Acquisition Time | Less than 700 ns |
| Hold-Mode Droop Rate | 0.01 uV/us |
| Supply Configuration | Dual positive and negative supply |
| Nominal Positive and Negative Supply | +/-12 V |
| Supply Tolerance | +/-10% |
| Encapsulado | 8-pin mini-DIP |
| Tipo de montaje | Through-hole |
| External Adjustment Components | 0 components required |
| AEC-Q100 Qualification | Not applicable |
Guía de configuración de pines de AD781ANZ 8-pin mini-dip
Configuración de pines para AD781ANZ (encapsulado 8-pin mini-dip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para AD781ANZ.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
AD781ANZ es adecuado para 6 aplicacións: High-Speed Data Acquisition, Precision Process Instrumentation, Rapid Waveform Sampling, Sampled Feedback Control, Analog Test and Measurement, Sensor Interface Conditioning.
High-Speed Data Acquisition
The AD781ANZ fits the input-stabilization stage of a data-acquisition system that must capture a changing analog signal before conversion. Its maximum acquisition time of 700 ns to 0.01% provides a defined timing target, while the self-contained sample-and-hold circuit avoids a discrete sampling network. The 0.01 uV/us hold-mode droop must be considered during the ADC conversion interval. A practical design should allocate the complete acquisition period, connect the source with low impedance, and place the amplifier close to the converter input to minimize sensitive routing.
Recomendado
Precision Process Instrumentation
The AD781ANZ is useful in industrial process instrumentation where a sensor signal changes faster than the measurement system can evaluate it continuously. Holding the selected value near the input of the downstream measuring circuit prevents later conversion errors caused by signal movement. Its 700 ns acquisition specification supports rapid sampling, while the +12 V and -12 V supply arrangement suits bipolar sensor signals. The implementation should verify the actual input range, source impedance, grounding method, and control timing for each industrial channel.
Recomendado
Rapid Waveform Sampling
For controlled waveform capture, the AD781ANZ can hold a selected full-scale input after acquisition in less than 700 ns. This characteristic is valuable when a repetitive or transient waveform must be frozen for later measurement rather than followed continuously. The 8-pin mini-DIP format supports straightforward prototyping and repair, and the monolithic implementation limits external timing components. Designers should compare the sample command edge with the acquisition interval and confirm that the held voltage remains within the converter's allowable range during conversion.
Recomendado
Sampled Feedback Control
The AD781ANZ can stabilize the feedback input of a sampled control loop so that the downstream comparator, amplifier, or converter observes a repeatable voltage. Its 700 ns maximum acquisition time provides fast settling between control events, while the 0.01 uV/us droop characterizes how the held value changes over time. Because a feedback loop also depends on stable timing and reference accuracy, the design should verify control-delay margins, loop gain, and output range before replacing a continuously sampled feedback path.
Recomendado
Analog Test and Measurement
The AD781ANZ suits laboratory and production-test fixtures that need to capture a test-node voltage quickly and hold it for slower measurement instrumentation. The less-than-700 ns acquisition time reduces the timing window between sensing and holding, while the monolithic implementation makes the fixture compact and straightforward to calibrate. Through-hole mini-DIP construction also simplifies replacement in legacy test systems. Before insertion, confirm that the fixture's control waveform, supply rails, input amplitude, and allowable droop are compatible with the manufacturer specifications.
Recomendado
Sensor Interface Conditioning
The AD781ANZ can serve as a temporary storage element between a bipolar sensor output and a subsequent amplifier or converter. A sensor signal that is not stationary during conversion may be held at a defined level, reducing acquisition error. The AD781ANZ's 700 ns acquisition specification is particularly relevant when the sensor output changes quickly, and its +12 V and -12 V operating arrangement supports signals centered around ground. Input protection, offset, sensor drive current, and the source impedance presented to the sampling input must be checked separately.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para AD781ANZ — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | AD783 | AD784 | LF398N |
|---|---|---|---|---|
| Package | 8-pin mini-DIP | 8-pin mini-DIP | 8-pin mini-DIP | 8-pin mini-DIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Product Type | Monolithic sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier |
| Channel Count | 1 channel | 1 channel | 1 channel | 1 channel |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole |
Diferenciadores clave
- Guaranteed high-speed acquisition over temperature (frente a LF398N)
- Documented low hold-mode droop (frente a AD783)
- Self-contained implementation (frente a AD784)
Notas de diseño
Route the analog input directly to the AD781ANZ sampling pin with minimal trace length and avoid sharing sensitive input nodes with digital or switching-current paths. High-impedance sampling paths are susceptible to leakage, coupling, and parasitic capacitance. Keep the acquisition and hold control traces away from the analog input and provide a clean ground reference to reduce acquisition errors and channel-to-channel coupling.
Validate acquisition settling with the actual source impedance, input voltage, control timing, and downstream load rather than relying only on the 700 ns maximum acquisition specification. A high source resistance can slow the effective settling time, while input capacitance and leakage can influence the held value. Measure at the relevant temperature and supply condition, and allow the full acquisition interval before the downstream converter samples the held voltage.
Use dual positive and negative supplies in accordance with the manufacturer's permitted operating range, and place power-bypass components close to the supply pins. The listed nominal configuration is +/-12 V with +/-10% tolerance, but absolute maximum and operating limits must be confirmed from the AD781 documentation. Avoid routing supply-return current through the signal ground path, because that can convert load current into measurement error at the sampling node.
Do not treat the acquisition specification as a hold-time specification. The AD781ANZ holds with a droop rate of 0.01 uV/us, so long conversion or processing intervals can allow the stored voltage to change. Confirm the maximum hold duration for the application, account for droop over that interval, and ensure that the sample-control timing does not enter an invalid state during power-up or shutdown.
Información de cumplimiento
The AD781ANZ is a legacy analog instrumentation IC rather than an automotive-qualified device. Specific material-compliance declarations were not identified and are therefore recorded as unknown.