ADM231LARZ - Low-Power +5V RS-232 Transceiver | Analog Devices
部品番号: ADM231LARZ ✗ 生産終了ADM231LARZ 概要
An RS-232 transceiver is an interface IC that converts logic-level signals between a microprocessor or UART and the voltage-defined RS-232 port. It belongs to the line-driver and receiver hierarchy, combining driver circuitry, receiver circuitry, level shifting, and electrical-noise control in one package. Such devices provide the voltage translation and signal conditioning required when a CMOS UART operates from a supply rail different from the RS-232 interface voltage range.
The ADM231L series is identified by Analog Devices as a low-power, +5V CMOS RS-232 solution. The ADM231LARZ combines two transmitters and two receivers, which permits simultaneous operation of two serial channels or allocation of separate transmit and receive paths. Its SOP-16 package is suitable for conventional through-hole PCB assembly and industrial control, instrumentation, data-acquisition, and embedded equipment designs.
Analog Devices lists the ADM231L family as obsolete, making lifecycle status an important selection criterion for new designs. For an existing supported design, the device can remain appropriate where its original electrical and pin requirements are already validated. For a new production release, engineers should evaluate a currently supported RS-232 transceiver after checking pin compatibility, supply voltage, driver and receiver ratings, shutdown behavior, and external-network requirements.
Typical applications include industrial serial consoles, barcode-scanner interfaces, test equipment, embedded data loggers, and RS-232 port expansion. In a two-port design, each transmitter drives a corresponding receiver through the external RS-232 connector and cable network. The internal receiver converts the bipolar RS-232 signal back to a logic level that can be interpreted directly by a UART.
PCB design should follow the Analog Devices pin-description table and the manufacturer’s recommended decoupling guidance. Place the +5V bypass capacitor close to the supply pins, route driver outputs and receiver inputs away from sensitive logic, and verify connector protection for the intended cable length and industrial noise environment. RS-232 voltage levels must not be applied directly to a UART pin without the transceiver.
This page combines the manufacturer lifecycle statement with practical guidance for obsolete-part risk assessment, interface topology selection, PCB implementation, and drop-in replacement investigation. It also distinguishes the verified ADM231LARZ identity from unconfirmed alternatives, helping engineers make a defensible sourcing and redesign decision.
ドロップイン代替品: ADM231LARZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエストADM231LARZ 仕様
| Product Type | RS-232 transceiver |
| 電源電圧 | +5 V |
| Maximum Supply Voltage | 5.5 V |
| Driver Count | 2 |
| Receiver Count | 2 |
| Interface Standard | EIA-232-E |
| Technology | CMOS |
| Power Class | Low power |
| Temperature Grade | Industrial |
| パッケージ | 16-pin SOP |
| Terminal Count | 16 |
| 実装タイプ | Surface mount |
| RoHS ステータス | unknown |
| REACH Status | unknown |
ADM231LARZ 16-pin sop ピン配置ガイド
ADM231LARZ (16-pin sop パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: ADM231LARZ.
詳細は データシート をご参照ください。
主な用途
ADM231LARZ の用途: 6 件s: Industrial Serial Console, Barcode Scanner Interface, Data Acquisition Instrument, Embedded UART Port Expansion, Instrumentation Control System, Serial Data Logger.
Industrial Serial Console
The ADM231LARZ fits an industrial serial console requiring two RS-232 channels from a +5V supply. Two drivers and two receivers allow the console to support separate transmit and receive paths or two bidirectional ports. The device is appropriate when an established UART board uses this SOP-16 footprint and the original interface timing is already validated. Because the ADM231L family is obsolete, a new production release should also evaluate a currently supported transceiver with equivalent pin and signal behavior.
おすすめ
Barcode Scanner Interface
The ADM231LARZ can connect a barcode scanner or other RS-232 peripheral to a controller that operates from +5V. Its driver converts the controller’s logic-level transmit signal to RS-232 levels, while the receiver converts the scanner response back to CMOS logic for the UART. The dual-driver and dual-receiver arrangement provides additional interface capacity for configuration or auxiliary devices. Confirm signal polarity, data rate, and connector wiring against the Analog Devices ADM231L datasheet.
おすすめ
Data Acquisition Instrument
The ADM231LARZ is suitable for laboratory and industrial data-acquisition equipment that communicates through legacy RS-232 ports. A single +5V supply powers the interface, while the two transmit and two receive channels support more than one instrument connection or separate control and measurement paths. The SOP-16 package simplifies integration with equipment that already uses surface-mount through-hole assembly. Verify ground referencing, cable transients, and logic thresholds before connecting external equipment.
おすすめ
Embedded UART Port Expansion
The ADM231LARZ can expand the serial connectivity of an embedded controller when two RS-232 links are required. The two transmitters drive outbound UART signals after RS-232 level conversion, and the two receivers recover logic-level inputs from connected devices. Using a dedicated transceiver prevents the controller from directly handling bipolar RS-232 voltage levels. Existing designs should verify the 16-pin SOP footprint and all enable or shutdown connections in the manufacturer pin-description table.
おすすめ
Instrumentation Control System
The ADM231LARZ fits legacy instrumentation systems that rely on RS-232 for configuration, test commands, and status reporting. Its +5V operation allows implementation in equipment where the control electronics do not have a higher-voltage interface rail. Two driver and receiver channels can serve two ports without duplicating the level-conversion function. Designers should check receiver noise immunity, line-driver loading, and the external RS-232 connector’s surge-protection arrangement before deployment.
おすすめ
Serial Data Logger
The ADM231LARZ can be used in a compact data logger that exchanges commands and recorded data through RS-232. Its two channels permit a bidirectional command port plus a second status or export link, while the +5V supply requirement supports integration with embedded control electronics. For an existing SOP-16 layout, this arrangement preserves the established footprint and reduces redesign risk. For new loggers, compare a supported transceiver for supply availability, low-power behavior, and exact UART compatibility.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ADM231LARZ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 |
|---|---|
| Product Type | RS-232 transceiver |
| Supply Voltage | +5 V |
| Maximum Supply Voltage | 5.5 V |
| Driver Count | 2 |
| Receiver Count | 2 |
| Interface Standard | EIA-232-E |
| Package | 16-pin SOP |
| Brand | Analog Devices |
| Temperature Grade | Industrial |
| Lifecycle Status | Obsolete |
| Technology | CMOS |
| Power Class | Low power |
主な差別化要因
- Four RS-232 conversion channels in one SOP-16 device (vs Single-channel RS-232 driver families)
- Single +5V interface implementation (vs Higher-voltage RS-232 transceiver families)
- Established industrial interface format (vs Newer compact interface packages)
設計ノート
Assign every connection from the Analog Devices ADM231L datasheet, Revision C, rather than inferring pin functions from another 16-pin RS-232 transceiver. Confirm the SOP-16 footprint, pin-1 orientation, power pins, enable or shutdown functions, driver outputs, and receiver inputs. Place the supply bypass capacitor close to the +5V connection and provide an unobstructed ground return to minimize susceptibility to switching and cable-coupled noise.
Do not connect RS-232 driver outputs directly to a microcontroller UART, and do not connect a UART pin directly to an RS-232 connector. The ADM231LARZ performs the required level translation in both directions. Also avoid assuming that another SOP-16 RS-232 device is pin-compatible: enable polarity, shutdown behavior, receiver thresholds, driver voltage, and channel assignment can differ even when the package dimensions match.
For industrial equipment, keep the transceiver close to the RS-232 connector and separate driver outputs from receiver inputs and sensitive control traces. Use the manufacturer’s recommended supply decoupling and provide suitable connector protection for the expected cable environment. Validate the completed assembly for ESD, conducted noise, ground offsets, and unintended receiver activity before production release.
コンプライアンス情報
The Analog Devices product page identifies the ADM231L family as obsolete but does not expose RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status in the verified product summary.