Analog Devices

ADM3065EBRZ Isolated CAN Transceiver | Analog Devices

部品番号: ADM3065EBRZ ✓ 生産中
MOQ: 1 |

ADM3065EBRZ 概要

The Analog Devices ADM3065EBRZ is an isolated CAN transceiver designed for industrial communication links where galvanic isolation, dependable bus operation, and integrated power transfer are important. It belongs to the CAN transceiver family, a category of interface ICs that converts between a host logic-level CAN connection and the differential CAN bus. The device combines a CAN transmitter and receiver with isolation circuitry, allowing a controller to communicate across a high-potential barrier without a direct galvanic path between bus-side and logic-side circuits.

An isolated CAN interface is used when two systems connected to the same bus operate at different ground potentials or where safety standards require separation between the bus and electronics. The ADM3065EBRZ family is designed for industrial automation, motor control, building controls, robotics, power-conversion equipment, and distributed control networks. Its integrated isolated DC/DC converter allows the bus-side transceiver circuitry to receive its operating power across the isolation barrier, reducing the number of external isolated power components normally required in a two-node CAN design.

CAN, or Controller Area Network, is a multi-master serial bus that supports deterministic communication among nodes. A CAN transceiver handles the physical layer by driving the bus during transmission and converting received bus levels into logic-compatible signals during reception. Bus arbitration is handled by the CAN controller, while the transceiver manages differential signaling, bus termination, and electrical loading. Because multiple nodes share the same conductors, transceiver characteristics, termination strategy, and cable topology directly affect network reliability.

The ADM3065EBRZ is supplied in an Analog Devices BZ package designation associated with a leadless surface-mount format. Confirm the exact package dimensions, exposed-pad treatment, pin assignments, and recommended land pattern against the current Analog Devices datasheet before laying out a board. Its operating limits, isolation rating, bus-node count, data rate, loopback and fault-reporting behavior, and automotive qualification status should also be checked against the latest manufacturer documentation for the exact ordering code.

In a practical design, place the transceiver close to the CAN connector and place the 120-ohm termination only at the two physical ends of the bus. Keep the bus traces short, pair them consistently, and avoid routing them beside switching nodes or high-current power paths. Provide the interface IC with a clean, decoupled logic-side supply and confirm that the host controller's CAN TXD and RXD levels match the ADM3065EBRZ input thresholds. The Request a Quote form on this page can be used to obtain current availability, lead time, and a formal quotation for the exact MPN.

ドロップイン代替品: ADM3065EBRZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

この製品に利用可能なドロップイン代替品はありません。

代替品をリクエスト

ADM3065EBRZ 仕様

仕様はありません

ADM3065EBRZ standard ピン配置ガイド

ADM3065EBRZ (standard パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。

ADM3065EBRZ の standard パッケージピン配置図

詳細なピン配置データはありません: ADM3065EBRZ.

詳細は データシート をご参照ください。

主な用途

ADM3065EBRZ の用途: 6 件s: Isolated Industrial CAN Node, Servo and Motor-Drive Controller Interface, Robotics Network Backbone, Building Automation Gateway, Distributed Power-Conversion Monitoring, Instrumentation and Measurement Front End.

🏭

Isolated Industrial CAN Node

The ADM3065EBRZ fits an isolated industrial CAN node because it places a CAN transceiver and an isolated DC/DC converter on the bus side of a logic-side controller. This arrangement lets a PLC, sensor gateway, or industrial controller exchange deterministic command and status data without connecting the two ground domains. The integrated power transfer can reduce the component count of a two-node isolated CAN link, while the manufacturer datasheet defines the required supply ranges, isolation limits, and operating conditions.

⚡

Servo and Motor-Drive Controller Interface

In a servo or motor-drive controller, the ADM3065EBRZ can provide the isolated connection between the real-time control electronics and a CAN command bus that extends toward machine-level automation equipment. Isolation helps keep high-current switching disturbances and ground offsets from being transferred directly into the controller domain. Designers should verify transient immunity, loop timing, and the maximum permitted bus length, then apply the placement and filter recommendations from the manufacturer datasheet.

🤖

Robotics Network Backbone

A robotic arm or mobile robot can use the ADM3065EBRZ as an isolated CAN interface for connecting motion-control and sensor subsystems over a shared bus. The isolation boundary supports equipment sections with different reference potentials, while the integrated isolated supply avoids a separate bus-side supply converter in simple nodes. The bus must remain within the device's rated node count and data rate, and the mechanical cable length and termination arrangement should be validated before deployment.

🏢

Building Automation Gateway

Building-automation gateways often connect controllers that sit on different power and ground domains, making the ADM3065EBRZ appropriate for an isolated CAN segment. The device supports communication between supervisory equipment and distributed HVAC, lighting, or access-control modules while limiting fault-current paths across the separation boundary. Confirm the building system's data rate, node population, environmental temperature, and fault-recovery requirements against the manufacturer specifications before selecting the interface.

🔋

Distributed Power-Conversion Monitoring

Power-conversion equipment can use the ADM3065EBRZ to connect a monitoring controller to a CAN management bus while the power stage operates at a substantially different common-mode potential. The isolated transceiver and integrated bus-side power are useful in systems where a galvanic path to the switching stage is undesirable. Engineers should check the isolation withstand rating, working voltage, temperature range, and fault outputs against the actual power-stage safety requirements.

📟

Instrumentation and Measurement Front End

Laboratory and industrial instrumentation can use the ADM3065EBRZ to bridge a CAN-based measurement network to control logic that operates from another supply domain. Isolation supports repeatable measurements when the measurement hardware and host computer have different ground references, and the integrated DC/DC function simplifies bus-side power implementation. For accurate acquisition, keep the interface away from high-slew-rate nodes, follow the recommended input and output filtering, and verify ground bounce during high-current switching.

What is the ADM3065EBRZ used for?
The ADM3065EBRZ is used as an isolated interface between a CAN controller and a differential CAN bus. According to the Analog Devices ADM3065E datasheet, its isolation barrier separates the logic-side circuitry from the bus-side circuitry, while the integrated isolated DC/DC converter supplies bus-side power. This makes the device suitable for industrial controllers, motor drives, robotics, and building-control systems where the bus and controller may be at different ground potentials.
Where can I download the ADM3065EBRZ datasheet PDF?
The ADM3065EBRZ documentation is available through the Analog Devices product page listed on this site. The manufacturer datasheet contains the authoritative BZ package drawings, pin-description table, isolation ratings, recommended operating conditions, and electrical characteristics. Use the pin-description table and the land-pattern section from that document when assigning PCB tracks, because connector and package details determine the correct footprint. The product page also links to the current revision of the data sheet and related evaluation material.
Where can I find the ADM3065EBRZ pinout?
The ADM3065EBRZ pinout is shown in the pin-configuration and pin-description sections of the Analog Devices ADM3065E datasheet. Use that table to identify the logic-side supply, ground, CAN transmit input, CAN receive output, isolation boundary, and bus-side terminals for the BZ package. Before routing a board, confirm the exposed-pad or thermal-pad requirements and the recommended land pattern in the package drawing section, and verify all connections against the latest manufacturer revision.
What are the key specifications of ADM3065EBRZ that engineers should know?
The principal engineering characteristics of the ADM3065EBRZ are its role as an isolated CAN transceiver, its reinforced isolation barrier, its integrated isolated DC/DC supply, and its compatibility with industrial CAN networks. The exact isolation withstand voltage, maximum data rate, supply ranges, operating temperature, and fault-detection behavior must be confirmed in the current Analog Devices datasheet. These parameters determine the safety margin, bus topology, decoupling requirements, and thermal design of the finished equipment.
Does the ADM3065EBRZ include an isolated power supply?
The ADM3065EBRZ family integrates an isolated DC/DC converter so the bus-side transceiver section can receive operating power across the isolation barrier. This integration can simplify a galvanically isolated CAN node by reducing the number of discrete isolated supply components and their associated transformers, rectifiers, and filtering networks. Confirm the converter's power rating, efficiency, and available output current in the Analog Devices datasheet before sizing system load and thermal margins.
Can ADM3065EBRZ be used in industrial automation systems?
Yes, the ADM3065EBRZ is designed for isolated CAN communication in industrial automation and control systems. Its isolation barrier supports equipment interconnection at differing ground potentials, while the CAN transceiver provides the physical-layer link between the host controller and the bus. It is suitable for motor controllers, PLC peripherals, factory sensors, and actuator nodes. Check the exact operating temperature, data rate, bus-node count, and transient limits in the manufacturer datasheet before finalizing a harsh-environment design.
What CAN applications are best suited to the ADM3065EBRZ?
The ADM3065EBRZ is best suited to galvanically isolated CAN nodes in motor drives, industrial PLC interfaces, robotics controllers, power-conversion equipment, and building automation. Integrated isolated power is particularly useful where the bus-side transceiver must operate across a high-voltage barrier. In each case, the bus must remain within the device's specified node count and data rate, and both ends of a terminated CAN segment need the correct termination arrangement.
What is the difference between ADM3065EBRZ and a non-isolated CAN transceiver?
The ADM3065EBRZ adds a reinforced isolation barrier and an integrated isolated DC/DC converter between the logic side and the CAN bus side. A non-isolated transceiver, such as the SN65HVD52DR family, couples the controller ground directly to the bus ground and does not provide transfer power across a safety barrier. The ADM3065EBRZ therefore suits higher-potential separation applications, while a non-isolated device can be simpler and lower-cost when ground-potential separation is unnecessary.
Can the SN65HVD52DR replace the ADM3065EBRZ as a drop-in part?
No, the SN65HVD52DR is not a pin-to-pin drop-in replacement for the ADM3065EBRZ. The SN65HVD52DR is a non-isolated CAN transceiver with different supply, ground, and isolation arrangements, so substituting it would remove the safety barrier and require PCB and schematic changes. The ADM3065EBRZ should be retained when isolated bus-side power and galvanic separation are required; otherwise, a non-isolated transceiver can be considered as a redesigned alternative rather than a drop-in exchange.
When should I choose ADM3065EBRZ instead of a non-isolated CAN transceiver?
Choose the ADM3065EBRZ when galvanic isolation is required between the controller and CAN bus, when the two sides operate at different ground potentials, or when system safety rules prohibit a direct ground path across a high-voltage boundary. Choose a non-isolated transceiver such as the SN65HVD52DR when the whole network shares one ground reference and the simpler, lower-cost interface meets every electrical and safety requirement. The decision should also consider transient immunity, integrated isolated power, node count, and fault-reporting requirements.
What is the best drop-in replacement for ADM3065EBRZ?
No drop-in replacement is established for the ADM3065EBRZ because pin-compatible, electrically equivalent parts with the same isolation and integrated DC/DC features could not be confirmed. A substitute must match the BZ footprint, pin functions, isolation rating, supply arrangement, data rate, and fault behavior exactly. The Request a Quote form on this page supports an exact-MPN sourcing request, and the manufacturer datasheet should remain the reference for any engineering substitution review.
Is the ADM3065EBRZ suitable for motor-drive applications?
The ADM3065EBRZ is suitable for isolated CAN communication in motor-drive systems where the controller must remain separated from high-energy power stages. Its integrated isolated DC/DC converter simplifies bus-side powering, and the isolation barrier helps limit fault-current paths between the two domains. Confirm the isolation rating, CAN data rate, and transient performance against the drive's safety requirements, and place the device and its protection components according to the layout guidance in the manufacturer datasheet.
How should a CAN bus with ADM3065EBRZ be terminated?
Terminate the CAN bus with 120-ohm resistors at the two physical endpoints of the segment rather than at every node. The ADM3065EBRZ transceiver connects the controller to the differential bus conductors, so incorrect termination raises the common-mode voltage and can impair recessive-bit detection. Keep the trunk wiring short and paired, place termination close to the connector, and verify bus timing and signal integrity with an oscilloscope during prototype validation.
Where can I buy ADM3065EBRZ online?
Use the Request a Quote form on this page to request the ADM3065EBRZ, current lead time, and available order quantities. Quote requests should include the exact ordering code ADM3065EBRZ and your required quantity so the manufacturing and packaging options can be confirmed. The manufacturer product page and datasheet linked on this site provide the authoritative technical details needed before committing the part to a design.
What is the price of ADM3065EBRZ?
Current pricing and volume availability for the ADM3065EBRZ are obtained through the Request a Quote form on this page. The form accepts the exact MPN and requested quantity, allowing purchasing to confirm the appropriate price break and lead time. Because distributor pricing changes frequently, use the live quotation rather than a static price reference when budgeting a new production release or building a multi-year procurement plan.
What is the lead time and stock status for ADM3065EBRZ?
Lead time and current stock status for the ADM3065EBRZ must be confirmed through the Request a Quote form on this page. Provide the required quantity, target date, and any required production or traceability documentation so purchasing can return an accurate schedule. For new industrial or automotive programs, request a periodic supply commitment and review the manufacturer lifecycle information before placing a long-term blanket order.
Is ADM3065EBRZ RoHS compliant and qualified for automotive use?
The RoHS, REACH, lead-free, and automotive qualification status for the ADM3065EBRZ must be confirmed for the exact ordering code in the current Analog Devices product documentation. The BZ commercial ordering suffix does not by itself establish AEC-Q100 qualification. For an automotive design, request the automotive-grade ordering option and its supporting qualification documentation rather than assuming that the standard ADM3065EBRZ ordering code satisfies an AEC-Q100 requirement.

エンジニアリング参考データ: ADM3065EBRZ — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the ADM3065EBRZ when a CAN node must maintain galvanic separation between the host controller and the bus, when the two sides use different ground references, or when an isolated power path is required. The integrated isolated DC/DC converter is especially useful in compact two-node links where adding a discrete isolated supply would increase component count and board area. Choose a non-isolated CAN transceiver such as the SN65HVD52DR when the entire network shares one ground domain, the safety plan permits a direct connection, and lower cost or simpler supply architecture has priority. Do not treat that non-isolated part as a drop-in replacement: its pin functions, isolation behavior, and supply arrangement differ. Before either device is released to production, verify the chosen part's data rate, node count, thermal limits, fault behavior, isolation rating, and exact package footprint against current manufacturer documentation.

代替品との比較

パラメータ この製品
Brand Analog Devices
Product Type Isolated CAN transceiver
Galvanic Isolation Yes
Integrated Isolated DC/DC Converter Yes

主な差別化要因

  • Galvanic isolation between logic-side and bus-side circuitry (vs SN65HVD52DR)
  • Integrated isolated DC/DC conversion in the transceiver package (vs SN65HVD52DR)
  • Protection of control electronics from bus-side ground shifts (vs SN65HVD52DR)

設計ノート

Place the ADM3065EBRZ close to the CAN connector and route the CANH and CANL conductors as a tight, coupled pair. Keep the bus traces away from switching-node edges, relay contacts, and high-current return paths, because common-mode noise can disturb recessive-bit detection. Use a continuous ground or return reference beneath the pair when the board stackup permits, and follow the manufacturer layout recommendations for isolation-barrier clearance, which must not be bridged by copper.

Use the supply and bypass values specified in the Analog Devices datasheet for both the logic-side and bus-side domains. The integrated isolated DC/DC converter supplies the bus-side section, but its load capacity, startup behavior, and efficiency still determine the available margin. Check the converter power rating against the transceiver's operating current, keep high-current return paths out of the sensitive logic ground region, and verify startup sequencing if the host controller begins transmitting immediately after reset.

Do not terminate every CAN node with 120-ohm resistors; install termination only at the two ends of the trunk. Also avoid using a non-isolated transceiver as an assumed drop-in substitute, because removing the isolation barrier changes safety, grounding, and fault-current behavior. Confirm the BZ footprint and pin names against the current datasheet, verify the maximum bus length and node count for the selected data rate, and validate recessive and dominant levels with an oscilloscope during hardware bring-up.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The exact ordering code and current manufacturer declarations should be reviewed for RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status.

データ検証日: 2026-11-23 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

ADM3065EBRZ datasheet ADM3065EBRZ pinout ADM3065EBRZ datasheet pdf ADM3065EBRZ package ADM3065EBRZ isolated CAN transceiver ADM3065EBRZ equivalent ADM3065EBRZ replacement ADM3065EBRZ drop-in replacement ADM3065EBRZ vs SN65HVD52DR Analog Devices ADM3065EBRZ ADM3065EBRZ application circuit ADM3065EBRZ isolation voltage ADM3065EBRZ CAN data rate ADM3065EBRZ price ADM3065EBRZ stock

関連部品&用語

Analog Devices ADM3065EBRZ ADM3065E isolated CAN transceiver CAN transceiver Controller Area Network CAN bus interface IC serial interface galvanic isolation isolation barrier reinforced isolation isolated DC/DC converter differential signaling common-mode voltage 120-ohm termination bus arbitration industrial automation motor drive robotics building automation power conversion BZ package surface mount
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示