ADM3065EBRZ Isolated CAN Transceiver | Analog Devices
MPN: ADM3065EBRZ ✓ Hoạt độngADM3065EBRZ Tóm tắt
An isolated CAN interface is used when two systems connected to the same bus operate at different ground potentials or where safety standards require separation between the bus and electronics. The ADM3065EBRZ family is designed for industrial automation, motor control, building controls, robotics, power-conversion equipment, and distributed control networks. Its integrated isolated DC/DC converter allows the bus-side transceiver circuitry to receive its operating power across the isolation barrier, reducing the number of external isolated power components normally required in a two-node CAN design.
CAN, or Controller Area Network, is a multi-master serial bus that supports deterministic communication among nodes. A CAN transceiver handles the physical layer by driving the bus during transmission and converting received bus levels into logic-compatible signals during reception. Bus arbitration is handled by the CAN controller, while the transceiver manages differential signaling, bus termination, and electrical loading. Because multiple nodes share the same conductors, transceiver characteristics, termination strategy, and cable topology directly affect network reliability.
The ADM3065EBRZ is supplied in an Analog Devices BZ package designation associated with a leadless surface-mount format. Confirm the exact package dimensions, exposed-pad treatment, pin assignments, and recommended land pattern against the current Analog Devices datasheet before laying out a board. Its operating limits, isolation rating, bus-node count, data rate, loopback and fault-reporting behavior, and automotive qualification status should also be checked against the latest manufacturer documentation for the exact ordering code.
In a practical design, place the transceiver close to the CAN connector and place the 120-ohm termination only at the two physical ends of the bus. Keep the bus traces short, pair them consistently, and avoid routing them beside switching nodes or high-current power paths. Provide the interface IC with a clean, decoupled logic-side supply and confirm that the host controller's CAN TXD and RXD levels match the ADM3065EBRZ input thresholds. The Request a Quote form on this page can be used to obtain current availability, lead time, and a formal quotation for the exact MPN.
Bộ thay thế dễ dàng lắp đặt cho ADM3065EBRZ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Không có bộ thay thế dễ dàng lắp đặt sẵn có cho sản phẩm này.
Yêu cầu các bộ thay thếADM3065EBRZ Thông số kỹ thuật
| Không có thông số kỹ thuật sẵn có |
Hướng dẫn cấu hình chân ADM3065EBRZ standard
Cấu hình chân cho ADM3065EBRZ (standard gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho ADM3065EBRZ.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ADM3065EBRZ phù hợp cho 6 Áp dụngs: Isolated Industrial CAN Node, Servo and Motor-Drive Controller Interface, Robotics Network Backbone, Building Automation Gateway, Distributed Power-Conversion Monitoring, Instrumentation and Measurement Front End.
Isolated Industrial CAN Node
The ADM3065EBRZ fits an isolated industrial CAN node because it places a CAN transceiver and an isolated DC/DC converter on the bus side of a logic-side controller. This arrangement lets a PLC, sensor gateway, or industrial controller exchange deterministic command and status data without connecting the two ground domains. The integrated power transfer can reduce the component count of a two-node isolated CAN link, while the manufacturer datasheet defines the required supply ranges, isolation limits, and operating conditions.
Được đề xuất
Servo and Motor-Drive Controller Interface
In a servo or motor-drive controller, the ADM3065EBRZ can provide the isolated connection between the real-time control electronics and a CAN command bus that extends toward machine-level automation equipment. Isolation helps keep high-current switching disturbances and ground offsets from being transferred directly into the controller domain. Designers should verify transient immunity, loop timing, and the maximum permitted bus length, then apply the placement and filter recommendations from the manufacturer datasheet.
Được đề xuất
Robotics Network Backbone
A robotic arm or mobile robot can use the ADM3065EBRZ as an isolated CAN interface for connecting motion-control and sensor subsystems over a shared bus. The isolation boundary supports equipment sections with different reference potentials, while the integrated isolated supply avoids a separate bus-side supply converter in simple nodes. The bus must remain within the device's rated node count and data rate, and the mechanical cable length and termination arrangement should be validated before deployment.
Được đề xuất
Building Automation Gateway
Building-automation gateways often connect controllers that sit on different power and ground domains, making the ADM3065EBRZ appropriate for an isolated CAN segment. The device supports communication between supervisory equipment and distributed HVAC, lighting, or access-control modules while limiting fault-current paths across the separation boundary. Confirm the building system's data rate, node population, environmental temperature, and fault-recovery requirements against the manufacturer specifications before selecting the interface.
Được đề xuất
Distributed Power-Conversion Monitoring
Power-conversion equipment can use the ADM3065EBRZ to connect a monitoring controller to a CAN management bus while the power stage operates at a substantially different common-mode potential. The isolated transceiver and integrated bus-side power are useful in systems where a galvanic path to the switching stage is undesirable. Engineers should check the isolation withstand rating, working voltage, temperature range, and fault outputs against the actual power-stage safety requirements.
Được đề xuất
Instrumentation and Measurement Front End
Laboratory and industrial instrumentation can use the ADM3065EBRZ to bridge a CAN-based measurement network to control logic that operates from another supply domain. Isolation supports repeatable measurements when the measurement hardware and host computer have different ground references, and the integrated DC/DC function simplifies bus-side power implementation. For accurate acquisition, keep the interface away from high-slew-rate nodes, follow the recommended input and output filtering, and verify ground bounce during high-current switching.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ADM3065EBRZ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này |
|---|---|
| Brand | Analog Devices |
| Product Type | Isolated CAN transceiver |
| Galvanic Isolation | Yes |
| Integrated Isolated DC/DC Converter | Yes |
Bảo phân biệt quan trọng
- Galvanic isolation between logic-side and bus-side circuitry (vsSN65HVD52DR)
- Integrated isolated DC/DC conversion in the transceiver package (vsSN65HVD52DR)
- Protection of control electronics from bus-side ground shifts (vsSN65HVD52DR)
Ghi chú thiết kế
Place the ADM3065EBRZ close to the CAN connector and route the CANH and CANL conductors as a tight, coupled pair. Keep the bus traces away from switching-node edges, relay contacts, and high-current return paths, because common-mode noise can disturb recessive-bit detection. Use a continuous ground or return reference beneath the pair when the board stackup permits, and follow the manufacturer layout recommendations for isolation-barrier clearance, which must not be bridged by copper.
Use the supply and bypass values specified in the Analog Devices datasheet for both the logic-side and bus-side domains. The integrated isolated DC/DC converter supplies the bus-side section, but its load capacity, startup behavior, and efficiency still determine the available margin. Check the converter power rating against the transceiver's operating current, keep high-current return paths out of the sensitive logic ground region, and verify startup sequencing if the host controller begins transmitting immediately after reset.
Do not terminate every CAN node with 120-ohm resistors; install termination only at the two ends of the trunk. Also avoid using a non-isolated transceiver as an assumed drop-in substitute, because removing the isolation barrier changes safety, grounding, and fault-current behavior. Confirm the BZ footprint and pin names against the current datasheet, verify the maximum bus length and node count for the selected data rate, and validate recessive and dominant levels with an oscilloscope during hardware bring-up.
Thông tin tuân thủ
The exact ordering code and current manufacturer declarations should be reviewed for RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status.