BCM56310A0KFEB - 24-Port Gigabit Ethernet Controller | Broadcom
部品番号: BCM56310A0KFEB ✓ 生産中BCM56310A0KFEB 概要
Broadcom BCM56310 series devices are used where a system must consolidate multiple Gigabit Ethernet links rather than operate as a small two-port or eight-port network controller. A 24-port configuration can reduce the number of physical MAC/PHY interfaces needed in an access, aggregation, or line-card design. This simplifies board routing and connector management, although the host processor, external transceivers, clocking, power delivery, and thermal management remain significant system-level design considerations.
The part is identified as a 24-port Gigabit Ethernet multilane controller in distributor catalogs. Its exact electrical ratings, supported host interface type, clocking architecture, transceiver interfaces, operating voltage, package dimensions, thermal characteristics, and RoHS classification are not stated in the available product records. Engineers should therefore use the manufacturer datasheet and hardware design documentation for the specific BCM56310A0KFEB configuration before finalizing a PCB or system design.
This controller is most relevant to industrial gateways, telecom access equipment, Ethernet aggregation systems, server or storage network appliances, and network interface modules that need many Gigabit Ethernet links behind a single processor-facing bus. Compared with a collection of discrete eight-port controllers, a 24-port controller can reduce component count and simplify control-plane software integration. The tradeoff is that the fabric and host interface must sustain the aggregate traffic expected across all 24 ports while maintaining deterministic latency and loss-free behavior.
In a typical design, the BCM56310A0KFEB interfaces to external copper or optical PHYs, while the host processor provides firmware, configuration, traffic management, and management-plane services. Board designers should reserve high-speed routing capacity, use controlled-impedance layers, provide clean reference clocks, decouple every supply rail close to the device, and verify signal integrity with the exact PHY and backplane topology used in production.
The key selection question is not simply port count but end-to-end interface compatibility. Confirm package type, pin assignment, lane count, lane rates, reference-clock requirements, supported PHY types, firmware support, and thermal limits against the manufacturer documentation. This page combines catalog-level identification, sourcing guidance, drop-in alternative findings, and practical integration considerations for engineers evaluating the BCM56310A0KFEB.
ドロップイン代替品: BCM56310A0KFEB — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
BCM56310A0KFEBG
✅ ドロップイン📋 参考代替品(カタログ未掲載)
BCM56310A0KFEB 最大定格&電気的特性
| Product Type | 24-port Gigabit Ethernet multilane interface controller |
| Manufacturer | Broadcom |
| Ethernet Port Count | 24 ports |
| Supported Ethernet Speed per Port | 1 Gb/s |
| Interface Category | Interface controller |
BCM56310A0KFEB standard ピン配置ガイド
BCM56310A0KFEB (standard パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: BCM56310A0KFEB.
詳細は データシート をご参照ください。
主な用途
BCM56310A0KFEB の用途: 6 件s: 24-Port Gigabit Ethernet Access Equipment, Telecom Ethernet Aggregation Line Card, Industrial Multi-Port Ethernet Gateway, Server Network Interface Appliance, Managed Network Interface Module, Security and Surveillance Network Appliance.
24-Port Gigabit Ethernet Access Equipment
BCM56310A0KFEB fits access and aggregation equipment that must present 24 Gigabit Ethernet connections while keeping the host-side design consolidated. Its 24-port multilane controller role can replace several smaller network controllers, reducing board area and control-plane integration effort. The design must still allocate enough host-interface and SerDes bandwidth for the expected aggregate traffic, and it must follow the manufacturer lane map when assigning PHYs or optical modules. Differential-pair routing, reference-clock cleanliness, and per-rail decoupling are the principal implementation concerns because all 24 ports rely on the same controller and its supporting power network.
おすすめ
Telecom Ethernet Aggregation Line Card
The BCM56310A0KFEB is applicable to a telecom aggregation line card that converts multiple Gigabit Ethernet service links into a higher-speed host-facing connection. Consolidating 24 ports into one controller can simplify enclosure wiring and make port-level traffic management easier for the host software. For line-card use, verify the supported PHY types, operating-temperature grade, clocking architecture, and packet-performance requirements in the manufacturer documentation. The aggregate lane rate must exceed the expected worst-case ingress and egress traffic with headroom for congestion and system overhead.
おすすめ
Industrial Multi-Port Ethernet Gateway
A BCM56310A0KFEB-based gateway can provide 24 Gigabit Ethernet ports for factory equipment, cameras, controllers, and edge-computing nodes behind a single system processor. The controller's port density reduces the number of physical network interfaces that a gateway must accommodate. Industrial qualification and environmental limits must be checked against the exact device variant before deployment. Designers should also evaluate how the external PHY ecosystem affects cost, isolation requirements, surge protection, and the thermal load generated by 24 simultaneous high-rate links.
おすすめ
Server Network Interface Appliance
BCM56310A0KFEB can be used in a server or storage appliance that exposes a large bank of Gigabit Ethernet ports to external clients. Consolidating the links behind one controller allows the host processor to manage traffic through one primary device instead of numerous independent controllers. The host processor must provide sufficient bus bandwidth and firmware support for the configured lane map. Careful partitioning between channels and validation of the complete data path are essential when moving traffic among servers, storage arrays, and virtualization platforms.
おすすめ
Managed Network Interface Module
A managed network interface module can use BCM56310A0KFEB when it must support 24 Gigabit Ethernet ports in a limited enclosure. The controller provides a practical way to implement port statistics, traffic classification, link management, and host connectivity in one device. Its suitability depends on the module's supported media types, including any copper magnetics or optical modules connected to the controller. Keep the reference clock isolated from noisy sources and route each high-speed differential pair as a controlled-impedance structure with no unnecessary layer transitions.
おすすめ
Security and Surveillance Network Appliance
BCM56310A0KFEB is suitable for a security appliance or surveillance system that aggregates 24 Gigabit Ethernet camera or sensor links. A single high-density controller simplifies the relationship between the attached devices and the recording or analytics server. The design should verify the controller's supported PHY combinations and the host interface's ability to carry sustained multi-stream traffic. Power-supply sizing and thermal analysis must account for the combined controller, PHY, magnetics, and transceiver load rather than the controller alone.
おすすめ
エンジニアリング参考データ: BCM56310A0KFEB — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | BCM56310A0KFEBG |
|---|---|---|
| Brand | Broadcom | Broadcom |
| Product Function | 24-port Gigabit Ethernet multilane interface controller | BCM56310A0KFEB family variant |
主な差別化要因
- High-density 24-port Gigabit Ethernet integration (vs Common eight-port Ethernet controllers)
- Multilane host-facing architecture (vs Independent discrete-port controllers)
- Closest documented same-family substitute (vs BCM56310A0KFEBG)
設計ノート
Treat the multilane host interface and every SerDes connection as controlled-impedance channels. Use the manufacturer's reference stack-up and lane-routing rules, match differential pair lengths within the specified tolerance, avoid stubs, and minimize layer transitions on high-speed nets. The 24-port configuration can make simultaneous lane activity significant, so validate the complete topology with a channel simulation rather than estimating from a single pair.
Decouple each supply rail directly at the controller pins and follow the manufacturer capacitor values and placement rules. Estimated: if the controller consumes 8 W and the effective board-to-ambient thermal resistance is 25 C/W, the temperature rise would be about 200 C, so a practical 24-port design generally requires substantial copper, controlled airflow, or a thermal structure. Confirm actual device and system dissipation before sizing the power plane and heatsinking.
Keep the reference-clock route short, symmetric, and separated from switching power stages and high-current PHY outputs. Establish a solid ground reference beneath high-speed pairs, use short ground vias beside return-current transitions, and avoid routing clock and sensitive data beneath noisy magnetics or regulators. Confirm the pin assignment and exposed-pad connection in the manufacturer pin table before releasing the footprint.
A 24-port label does not guarantee that every configuration provides 24 simultaneous external PHY links. Verify the lane map, maximum SerDes rate, supported PHY media, firmware feature set, and host-bandwidth allocation. Also check the full ordering suffix when comparing BCM56310A0KFEB with BCM56310A0KFEBG; a similar family designation can conceal differences in temperature grade, packaging, or production configuration.
コンプライアンス情報
The available catalog records identify Broadcom BCM56310A0KFEB as a 24-port Gigabit Ethernet multilane interface controller but do not state RoHS, REACH, halogen-free, lead-free, or conflict-minerals status. Confirm declarations using the manufacturer product documentation and the declaration associated with the exact ordering suffix.