Texas Instruments

DAC8741HRGET - HART Modem with SPI | Texas Instruments

部品番号: DAC8741HRGET ✓ 生産中
24-pin VQFN (RGE), 4 mm x 4 mm Package
MOQ: 1 |

DAC8741HRGET 概要

The Texas Instruments DAC8741HRGET is a low-power HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible modem with an SPI interface, 24-pin VQFN (RGE) package, and a specified temperature range of -55°C to +125°C. It is designed for industrial process-control and industrial-automation equipment requiring a dedicated digital communication interface for fieldbus networks.

A HART modem is a physical-layer interface that adds digital communication over an analog instrumentation signal path. As a modem IC, the DAC8741H belongs to the interface-IC hierarchy, connecting embedded controllers with HART-compatible transmitters, sensors, actuators, and fieldbus equipment. The TI product page describes the device as a HART, FOUNDATION Fieldbus, and PROFIBUS PA-compliant modem suitable for both slave and master configurations in HART mode.

The principal feature of the DAC8741HRGET is its SPI host interface. The verified product information states that the interface includes a DO pin for daisy-chain support, together with interrupts and other control features. This allows a host microcontroller or processor to configure the modem and exchange status and command information through a serial interface while the integrated physical-layer circuitry handles the fieldbus signal.

The device is offered in a compact 24-VQFN package measuring 4 mm by 4 mm. Its industrial operating-temperature designation covers -55°C to +125°C, making the qualified ordering variant suitable for harsh industrial environments when the complete system requirements, qualification records, and application conditions are independently reviewed. The ordering suffix identifies the RGE package, and HRGET is supplied in tape-and-reel form.

Typical uses include process transmitters, fieldbus sensor transmitters, industrial controllers, data acquisition equipment, remote I/O systems, and PROFIBUS PA-compatible field devices. In these systems, the DAC8741HRGET can reduce the need for discrete modem circuitry while providing a standardized host-side connection through SPI.

Designers should confirm the exact receiver and transmitter implementation, timing limits, electrical levels, and external-component requirements against the manufacturer datasheet before release. The SPI signals, analog fieldbus connection, supply rails, grounding, and exposed-pad layout must be routed according to the recommended application circuit. Component availability and lifecycle commitments should also be checked for the intended production program.

This page consolidates verified manufacturer and distributor information with transparent data-gap markers, package guidance, comparison rows, and application-focused engineering context. It also distinguishes verified facts from specifications that require confirmation in the latest Texas Instruments datasheet.

ドロップイン代替品: DAC8741HRGET — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: DAC8741HRGET (同一形状・フットプリント) — 相違点: Operating Mode, Product Type.

Texas Instruments
Operating Mode: Half-duplex HART mode
Product Type: HART, FOUNDATION Fieldbus, and PROFIBUS PA modem
比較対象 DAC8741HRGET →

DAC8740HRGET

✅ ドロップイン ⚠️ 仕様未検証
Texas Instruments
📦 VQFN-24 (RGE), 4 mm x 4 mm
HART, FOUNDATION Fieldbus, and PROFIBUS PA modem · 2.7 V to 5.5 V · Half-duplex HART mode · Master or slave configuration · HART, FOUNDATION Fieldbus, and PROFIBUS PA · Low-power industrial modem · 24-pin VQFN · 4 mm × 4 mm

価格はお問い合わせください

データシートを見る →

DAC8742HRGET

✅ ドロップイン ⚠️ 仕様未検証
📦 VQFN-24 (RGE), 4 mm x 4 mm
Same TI DAC874xH family and 24-pin VQFN (RGE) package; verified performance difference is

📋 参考代替品(カタログ未掲載)

DAC8743HRGET

✅ ドロップイン ⚠️ 仕様未検証
📦 VQFN-24 (RGE), 4 mm x 4 mm
Same TI DAC874xH family and 24-pin VQFN (RGE) package; verified performance difference is

📋 参考代替品(カタログ未掲載)

DAC8741HRGET 最大定格&電気的特性

Product Type HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible modem IC
Host Interface SPI
Operating Mode Half-duplex HART master or slave configuration
動作温度 -55°C to +125°C
パッケージ 24-pin VQFN (RGE), 4 mm x 4 mm
ピン数 24 pins
実装タイプ Surface mount
Daisy-Chain Support DO pin included in the SPI interface
Interrupt Support Supported
Application Category Industrial process control and industrial automation

DAC8741HRGET 24-pin vqfn (rge), 4 mm x 4 mm ピン配置ガイド

DAC8741HRGET (24-pin vqfn (rge), 4 mm x 4 mm パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

DAC8741HRGET の 24-pin vqfn (rge), 4 mm x 4 mm パッケージピン配置図

詳細なピン配置データはありません: DAC8741HRGET.

詳細は データシート をご参照ください。

主な用途

DAC8741HRGET の用途: 6 件s: HART Process Transmitter, FOUNDATION Fieldbus Equipment, PROFIBUS PA Field Device, Industrial Remote I/O Module, Data Acquisition Front End, Industrial Gateway and Converter.

🏭

HART Process Transmitter

The Texas Instruments DAC8741HRGET fits a digital-output process transmitter that must superimpose HART communication on an analog process signal. Its 24-pin VQFN (RGE) package saves board area, while the SPI interface provides a structured connection to the transmitter's host controller. According to the manufacturer, the integrated modem can operate as a half-duplex HART master or slave with minimal external components. That integration can simplify the physical layer without replacing the complete analog measurement or output chain. Confirm the DAC8741H datasheet for supported HART data rates, receive thresholds, line-driver limits, timing, and the required external network components before freezing the transmitter design.

🌐

FOUNDATION Fieldbus Equipment

The DAC8741HRGET is suitable for FOUNDATION Fieldbus-compatible industrial equipment that connects an embedded controller to a fieldbus physical layer. The manufacturer identifies the DAC874xH family as compatible with HART, FOUNDATION Fieldbus, and PROFIBUS PA applications. Its SPI interface can carry configuration and status information to the host processor, and the -55°C to +125°C ordering specification covers a wide industrial temperature range. The 4 mm by 4 mm, 24-pin VQFN package also allows a compact implementation in transmitters and remote I/O modules. Designers must still implement the exact interface network, isolation strategy, protection, filtering, and grounding required by the target fieldbus standard and equipment safety requirements.

🏭

PROFIBUS PA Field Device

The DAC8741HRGET can support a PROFIBUS PA-compatible field device when its documented protocol features and electrical parameters satisfy the product specification. Texas Instruments explicitly lists PROFIBUS PA among the DAC874xH family applications, and the device provides an SPI host connection that can support deterministic configuration and status exchange. The compact 24-pin VQFN (RGE) package is useful in remote transmitters and compact I/O devices, while the -55°C to +125°C variant supports demanding industrial environments. A complete design must include the required fieldbus coupling, line termination, isolation, surge protection, and power-supply arrangement. Those network details are not provided in the verified snippets and must be taken directly from the current manufacturer documentation.

🔧

Industrial Remote I/O Module

The DAC8741HRGET is a practical choice for a compact remote I/O module that must add a standards-compatible fieldbus connection to sensors or actuators. Its SPI interface lets a host controller initialize the modem and respond to interrupts, while the integrated HART physical layer reduces the amount of discrete communications circuitry. The 24-pin VQFN (RGE) package helps minimize PCB footprint in densely populated remote modules. For deployment across -55°C to +125°C environments, designers should account for exposed-pad heat spreading, supply noise, protection networks, and enclosure-related temperature rises. Verify all pin assignments and layout guidance in the official 24-pin package drawing before layout release.

📊

Data Acquisition Front End

The DAC8741HRGET can add a HART communication channel to a data-acquisition front end that combines sensing, conversion, and remote diagnostics. The SPI host interface provides a convenient partition between the host processor and the communications modem, while half-duplex master or slave operation supports integration with different network topologies. Its 24-pin VQFN (RGE) package allows placement close to the analog and communications sections of the board. Because measurement accuracy can be affected by noise and ground-current coupling, the implementation should use the datasheet's recommended power and layout arrangement, keep modem return currents controlled, and validate the complete channel under simultaneous measurement and communication activity.

🌐

Industrial Gateway and Converter

The DAC8741HRGET is relevant to industrial gateways that translate or supervise fieldbus-connected equipment. A gateway can use the device's SPI interface for configuration and status monitoring while the integrated modem handles the HART physical layer. This can reduce interface complexity compared with a discrete transmitter implementation and provide a compact 24-pin VQFN option for space-constrained electronics. The wide -55°C to +125°C ordering specification supports harsh installations when the enclosure and thermal design preserve that operating range. Before using the modem in a gateway, verify supported baud rates, packet timing, interrupt behavior, line-coupling requirements, and isolation arrangements against the current Texas Instruments datasheet rather than inferring them from the family description.

What is the DAC8741HRGET?
The DAC8741HRGET is a Texas Instruments low-power modem IC for HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible industrial communication. According to the manufacturer product page, it provides a half-duplex HART physical layer with master or slave configurations and connects to a host controller through an SPI interface. The device is packaged as a 24-pin VQFN (RGE) measuring 4 mm by 4 mm.
What are the key specifications of DAC8741HRGET that engineers should know?
The DAC8741HRGET combines HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible modem functions with an SPI host interface in a 24-pin VQFN (RGE) package. According to Texas Instruments, the SPI interface includes a DO pin for daisy-chain support and provides interrupts. The ordering variant is specified for -55°C to +125°C operation, making the 4 mm by 4 mm surface-mount package appropriate for industrial equipment requiring a wide temperature range.
Where to buy DAC8741HRGET online?
The DAC8741HRGET can be found from Texas Instruments and listed distributors including DigiKey, Mouser, Octopart, and LCSC. The verified LCSC listing reports an in-stock price of $5.1963 as of 2026-10-28, while DigiKey describes the component as a 24-VQFN HART modem interface. Buyers should compare authorized-channel inventory, lot traceability, and production lead time rather than relying only on the lowest marketplace listing.
What is the price of DAC8741HRGET?
The verified reference price for DAC8741HRGET is $5.1963 per unit as of 2026-10-28 from the LCSC product listing. The supplied data does not contain separate volume-break prices, so all published tiers retain that same reference value instead of estimating unverified discounts. The Octopart result confirms that multiple distributors participate in pricing and availability comparisons, which may produce different quantities, lead times, and final transaction prices.
What is the lead time for DAC8741HRGET?
The verified data does not provide a manufacturer lead time for DAC8741HRGET as of 2026-10-28. The LCSC listing identifies the part as in stock, but an in-stock distributor quantity is not equivalent to a guaranteed production allocation. For a scheduled build, request a dated commitment from the selected authorized distributor and include buffer time for inspection, incoming testing, and any changes to the predicted bill of materials.
Is DAC8741HRGET in stock?
The DAC8741HRGET is reported as in stock by the verified LCSC result, which also lists a price of $5.1963 as of 2026-10-28. A separate distributor listing reports 550 pieces in stock, while DigiKey states that the part ships today in its search result. These statements describe distributor inventory rather than guaranteed XAIPART stock, so quantity should be confirmed before placing an order.
Where to download the DAC8741HRGET datasheet PDF?
The official DAC8741H product page at Texas Instruments is the preferred starting point for the DAC8741HRGET datasheet and supporting documentation. A separate verified AllDataSheet result identifies the document as the DAC874xH HART, FOUNDATION Fieldbus, and PROFIBUS PA modems data sheet and reports 53 pages. Because the manufacturer revision is not stated in the supplied data, download the current document from TI and verify its revision before using it for design approval.
Where to find the DAC8741HRGET pinout?
The DAC8741HRGET pinout is published in the manufacturer datasheet under the RGE package information. The verified component listings confirm a 24-pin VQFN (RGE) package with dimensions of 4 mm by 4 mm, but they do not provide the individual pin numbers or signal names. This page therefore does not reproduce an inferred pinout. Use the current Texas Instruments datasheet and its package drawing to verify every connection and exposed-pad requirement.
What can replace DAC8741HRGET?
No verified drop-in replacement was found in the supplied cross-reference results for the DAC8741HRGET. A replacement should match the 24-pin VQFN (RGE) land pattern, pin functions, SPI protocol, supported fieldbus modes, electrical limits, and thermal requirements. The related DAC8740H is a same-family device, but the supplied evidence does not establish pin-to-pin equivalence or quantify its functional differences, so it should not be treated as a drop-in replacement without datasheet verification.
What is the best cross-brand equivalent for DAC8741HRGET?
No cross-brand equivalent was verified as a pin-compatible replacement for the DAC8741HRGET in the provided data. Texas Instruments describes the device as a HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible modem with a 24-pin VQFN (RGE) package, and the cross-reference search results did not identify a qualified competitor part with matching pinout and electrical behavior. Engineers should use the manufacturer pinout and functional requirements as the acceptance criteria rather than treating a package-only match as interchangeable.
Is DAC8741HRGET suitable for industrial process control?
Yes, the DAC8741HRGET is specifically designed for industrial process-control and industrial-automation equipment. According to the manufacturer product page, the DAC874xH family supports HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible communication and can operate as a half-duplex HART master or slave with minimal external components. The -55°C to +125°C ordering specification supports harsh industrial environments, subject to system-level qualification.
How does DAC8741HRGET connect to a host controller?
The DAC8741HRGET connects to its host through an SPI interface and includes a DO pin for daisy-chain support. According to the verified Mouser product information, the device also provides various interrupts and other features. This arrangement separates host-side digital command and status handling from the HART physical layer, simplifying integration while still requiring the host processor, grounding, power, and external fieldbus network components to meet the datasheet requirements.
DAC8741HRGET vs DAC8740H - which is better for a HART transmitter?
The DAC8741HRGET is the appropriate choice when the verified 24-pin RGE ordering variant, -55°C to +125°C specification, and documented SPI features meet the transmitter requirements. The supplied evidence confirms that DAC8740H belongs to the same DAC874xH product family, but it does not provide a verified pin-to-pin comparison or quantify differences between the two devices. Select DAC8740H only after reviewing both datasheets for pin, electrical, protocol, and lifecycle equivalence.
When should I choose DAC8741HRGET over another fieldbus modem?
Choose the DAC8741HRGET when the design requires a documented combination of HART, FOUNDATION Fieldbus, and PROFIBUS PA compatibility, an SPI host interface, a 24-pin VQFN (RGE) package, and the -55°C to +125°C ordering specification. The choice is strongest when maintaining the same industrial communication platform, package, and host architecture is more valuable than introducing a new vendor. Confirm protocol timing, electrical characteristics, qualification, and lifecycle before committing to production.
Does DAC8741HRGET require external components?
The DAC8741HRGET integrates the required circuitry for half-duplex HART physical-layer operation in master or slave configurations, but the complete transmitter still requires application-specific support components. According to Texas Instruments, operation is possible with minimal external components, while the manufacturer datasheet remains the authority for required passives, coupling or termination networks, supply decoupling, filtering, and protection. Do not omit network components solely because the modem function is integrated.

エンジニアリング参考データ: DAC8741HRGET — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the DAC8741HRGET when an industrial system requires a compact 24-pin VQFN modem with an SPI host interface, HART half-duplex master or slave capability, and an ordering specification covering -55°C to +125°C. It is particularly relevant to HART transmitters, FOUNDATION Fieldbus equipment, PROFIBUS PA field devices, and remote I/O modules where maintaining the Texas Instruments DAC874xH architecture is desirable. The same-family alternatives may offer different modulation or channel characteristics, but the supplied data does not quantify those differences, so they should be selected only after direct comparison of the current datasheets. No cross-brand drop-in replacement was verified; do not approve a competitor solely because it uses a 24-pin QFN package. Before procurement, confirm electrical characteristics, external circuitry, protocol timing, lifecycle status, and authorized-channel availability. Also verify the temperature qualification and production requirements of the complete assembled system.

代替品との比較

パラメータ この製品 DAC8740HRGET DAC8742HRGET DAC8743HRGET
Package VQFN-24 (RGE), 4 mm x 4 mm VQFN-24 (RGE), 4 mm x 4 mm VQFN-24 (RGE), 4 mm x 4 mm VQFN-24 (RGE), 4 mm x 4 mm
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible modem IC DAC874xH-family modem IC DAC874xH-family modem IC DAC874xH-family modem IC
Pin Count 24 pins 24 pins 24 pins 24 pins

主な差別化要因

  • Documented multi-protocol modem positioning (vs DAC8740HRGET)
  • Wide industrial ordering temperature specification (vs DAC8742HRGET)
  • Compact 24-pin VQFN implementation (vs DAC8743HRGET)

設計ノート

Use the current Texas Instruments RGE package drawing as the controlling layout document. Place the modem's input, output, supply, and ground connections according to the datasheet's recommended application circuit, and provide a continuous ground reference beneath the package where the footprint permits. Do not infer individual signal names from the 24-pin count because the supplied snippets do not contain the official pin table.

Separate the modem's supply path from noisy analog and switching loads as far as the practical layout permits. Place local decoupling at the device's supply pins using the capacitance, voltage rating, and dielectric requirements published in the datasheet. Because the verified material identifies this as a low-power industrial modem but does not provide current or supply-voltage values, those limits must be confirmed before sizing the regulator and thermal budget.

The fieldbus connection is sensitive to external-component values, termination, protection, and grounding. Implement only the network shown for the intended HART, FOUNDATION Fieldbus, or PROFIBUS PA topology, and validate signal levels and timing with the actual cable and termination. Keep SPI routing away from the analog modem path where possible, and confirm that daisy-chain DO behavior remains compatible with the number of devices on the bus.

The 4 mm by 4 mm VQFN package can transfer heat through its exposed pad, but the verified data does not provide thermal resistance or maximum dissipation. Follow the manufacturer's exposed-pad assembly and copper-area guidance, and use the -55°C to +125°C ordering specification as an environmental target rather than proof that the assembled product meets that range without enclosure and thermal validation.

Do not treat the HART, FOUNDATION Fieldbus, and PROFIBUS PA-compatible description as proof that one board configuration supports every protocol simultaneously. Confirm the required mode, timing, baud rate, electrical layer, and isolation requirements for each product variant. Likewise, distributor inventory and an $5.1963 reference price do not guarantee production allocation; confirm lot status and delivery commitment against the approved BOM.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The supplied search results do not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. The device is an industrial interface IC rather than an automotive-qualified AEC-Q100 option in the provided evidence. Confirm material and environmental declarations with Texas Instruments for the exact ordering code.

関連検索

DAC8741HRGET DAC8741HRGET datasheet PDF Texas Instruments DAC8741HRGET DAC8741H HART modem IC 24-pin VQFN HART modem DAC8741HRGET SPI interface DAC8741HRGET industrial process control DAC8741HRGET PROFIBUS PA application DAC8741HRGET vs DAC8740H DAC8741HRGET drop-in replacement DAC8741HRGET buy price DAC8741HRGET pinout where to buy DAC8741HRGET online what can replace DAC8741HRGET

関連部品&用語

Texas Instruments DAC8741HRGET DAC8741H DAC874xH HART modem half-duplex HART physical layer FOUNDATION Fieldbus PROFIBUS PA SPI interface daisy chain industrial process control industrial automation fieldbus interface IC modem IC semiconductor VQFN-24 RGE package surface mount SMD -55°C to +125°C 4 mm x 4 mm package interrupt HART master HART slave
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示