ICL7135CQI+T 4.5-Digit ADC | Analog Devices | Precision
部品番号: ICL7135CQI+T ✓ 生産中ICL7135CQI+T 概要
A dual-slope ADC is a sigma-delta-style integrating converter that repeatedly ramps and measures an input against a fixed reference. The ICL7135 divides each conversion into measuring and integrating phases, rejecting much of the periodic noise found in industrial environments. Its integration period helps average unwanted components of the input while retaining the resolution required for a 4.5-digit display. In the system hierarchy, it is an ADC, an analog-to-digital converter, a data-acquisition IC, and ultimately a semiconductor.
Key features include 4.5-digit resolution, multiplexed BCD outputs suitable for decimal display drivers, differential high-impedance input architecture, and a specified 2.0000 V full-scale range. The multiplexed output interface reduces the number of dedicated output pins by sharing digit and BCD data lines. This makes the device useful for standalone panel meters and digital instruments that need displayed numerical results rather than a conventional binary-coded output for a digital bus.
The ICL7135 separates its analog and digital functions into dedicated circuit areas. The analog section includes the differential input path, integrator, reference comparison, and analog output multiplexing, while the digital section contains counters, timing control, output drivers, and control logic. Its dual-slope architecture supports good noise performance without requiring a high-speed successive-approximation conversion pipeline. Users should nevertheless provide stable reference and input conditions because gain accuracy is tied to reference quality and conversion timing.
Typical uses include digital panel meters, laboratory instruments, weighing systems, process-monitoring equipment, temperature controllers, and laboratory-grade measurement panels where a 4.5-digit BCD display is preferred. The differential inputs can measure bipolar or unipolar signals when the external analog network is designed for the selected reference and full-scale range. In each application, the front-end divider, reference source, input filtering, and display interface remain as important as the converter itself.
For PCB implementation, place the reference and input-network components close to their associated pins, keep digital BCD routes away from sensitive analog nodes, and provide the bypass and filtering specified by the manufacturer datasheet. Confirm timing, polarity, input-range, and BCD-output details against the ICL7135 datasheet before final routing. Commercial availability, current lot status, and a formal quotation should be confirmed through the Request a Quote form on this page.
This product page combines the manufacturer’s converter description with package details, application engineering guidance, and procurement-oriented information. It is designed to help engineers verify the 4.5-digit architecture, BCD display interface, PLCC footprint, reference requirements, and replacement constraints before committing the part to a new instrument design.
ドロップイン代替品: ICL7135CQI+T — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: ICL7135CQI+T (同一形状・フットプリント) — 相違点: Package.
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエストICL7135CQI+T 最大定格&電気的特性
| Converter Type | Monolithic dual-slope ADC |
| 分解能 | 4.5 digits |
| Number of Channels | 1 channel |
| Input Architecture | High-impedance differential inputs |
| Output Format | Multiplexed BCD outputs |
| Full-Scale Capability | 2.0000 V |
| Accuracy | ±1 count in 20,000 |
| Conversion Principle | Dual-slope integration |
| 動作温度範囲 | 0 °C to +70 °C |
| パッケージ | 28-pin PLCC, 11.51 mm × 11.51 mm |
| ピン数 | 28 pins |
| 実装タイプ | Surface mount |
| Shipping Format | Tape and reel |
ICL7135CQI+T 28-pin plcc, 11.51 mm × 11.51 mm ピン配置ガイド
ICL7135CQI+T (28-pin plcc, 11.51 mm × 11.51 mm パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: ICL7135CQI+T.
詳細は データシート をご参照ください。
主な用途
ICL7135CQI+T の用途: 6 件s: Digital Panel Meters, Laboratory Measurement Instruments, Weighing and Load Measurement, Process Monitoring Equipment, Temperature and Pressure Displays, Precision Bench Meters.
Digital Panel Meters
The ICL7135CQI+T fits a precision digital panel meter because it combines a 4.5-digit dual-slope conversion system with multiplexed BCD outputs intended for decimal display hardware. The high-impedance differential inputs can receive a scaled front-end signal while the converter’s specified ±1-count-in-20,000 accuracy supports readable instrumentation results. Use the manufacturer application circuit as the starting point for reference selection, input filtering, timing components, and display-driver interfaces.
おすすめ
Laboratory Measurement Instruments
The ICL7135CQI+T is appropriate for laboratory-style instruments that present a direct decimal measurement and can tolerate the conversion rate of a dual-slope ADC. Its differential high-impedance input supports front ends built around resistive dividers or sensor bridges, while the 2.0000 V full-scale capability provides a defined reference point for gain design. Accurate results still depend on a low-noise reference, correct input polarity, adequate filtering, and the timing network defined by the manufacturer datasheet.
おすすめ
Weighing and Load Measurement
The ICL7135CQI+T can serve as the measurement engine in a compact load-cell indicator because its high-impedance differential inputs suit carefully balanced sensor excitation and signal conditioning. The 4.5-digit multiplexed BCD output simplifies connection to decimal display hardware, and the integrating dual-slope method helps average periodic interference around industrial transducers. The analog front end must still provide excitation, common-mode protection, input filtering, and a stable reference while keeping sensitive routes away from digital outputs.
おすすめ
Process Monitoring Equipment
The ICL7135CQI+T suits process-monitoring equipment where a slowly changing analog signal must be converted into a stable decimal indication. Its integrating conversion cycle helps suppress repetitive interference, and the multiplexed BCD interface reduces the connection burden to common display hardware. The converter should be paired with input protection and filtering appropriate to the industrial signal, while the reference path requires careful layout to prevent drift from degrading the stated measurement accuracy.
おすすめ
Temperature and Pressure Displays
The ICL7135CQI+T is useful in temperature or pressure instruments designed around a dedicated numerical display rather than a digital communications bus. A bridge or resistive sensor signal can be scaled into the differential input network, while the BCD outputs drive the display section. Because the measured quantity changes slowly, the dual-slope integration period can be advantageous, although conversion latency must be checked against the intended refresh rate and any alarm or control-response requirements.
おすすめ
Precision Bench Meters
The ICL7135CQI+T can support a dedicated bench meter that prioritizes a readable 4.5-digit result and straightforward BCD display wiring. Its high-impedance differential input architecture permits a flexible analog front end, and the specified 2.0000 V full-scale range gives designers a reference for input-network calculations. To achieve repeatable readings, use a stable reference, shielded or guarded sensitive inputs, appropriate filtering, and a PCB layout that separates the analog and digital sections.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ICL7135CQI+T — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 |
|---|---|
| Brand | Analog Devices |
| Package | 28-pin PLCC, 11.51 mm × 11.51 mm |
| Converter Type | Monolithic dual-slope ADC |
| Resolution | 4.5 digits |
| Number of Channels | 1 channel |
| Output Format | Multiplexed BCD outputs |
| Input Architecture | High-impedance differential inputs |
| Full-Scale Capability | 2.0000 V |
| Accuracy | ±1 count in 20,000 |
| Operating Temperature Range | 0 °C to +70 °C |
設計ノート
Separate the analog and digital regions around the ICL7135CQI+T. Keep the reference, input-divider, filtering, and integration components close to their associated pins, and route multiplexed BCD data and digit-strobe signals away from sensitive analog nodes. Use the manufacturer application layout as the reference because small coupling between the two sections can degrade the converter’s apparent noise performance and measurement repeatability.
Design the differential input network for the intended source impedance and input range. High-impedance inputs do not remove the need for balanced routing, guarding, leakage control, and filtering; they instead make those details more important. Verify common-mode limits, input polarity, settling behavior, and conversion timing against the manufacturer datasheet before selecting resistor values or capacitor types.
Do not treat ICL7135CPI+ or TLC7135CDWR as direct replacements for the ICL7135CQI+T PLCC footprint. The PDIP and alternative surface-mount packages require different PCB land patterns. Likewise, do not assume that the base ICL7135CQI+ ordering code is a distinct substitute: its packaging format differs. Preserve the exact suffix unless the assembly process and manufacturer documentation confirm that another ordering code is acceptable.
コンプライアンス情報
No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was identified for this ordering code. The AEC-Q100 field is not applicable because ICL7135CQI+T is a commercial measurement converter rather than an automotive-qualified device.