Analog Devices

ICL7135CQI+T 4.5-Digit ADC | Analog Devices | Precision

MPN: ICL7135CQI+T ✓ Aktif
28-pin PLCC, 11.51 mm × 11.51 mm Package
MOQ: 1 |

ICL7135CQI+T Genel Bakış

Analog Devices ICL7135CQI+T is a monolithic 4.5-digit dual-slope analog-to-digital converter with multiplexed BCD outputs, high-impedance differential inputs, and a 2.0000 V full-scale capability. The commercial-temperature device is packaged in a 28-pin PLCC and identified by the ICL7135CQI+T tape-and-reel ordering code. According to the Analog Devices product page, its specified accuracy is ±1 count in 20,000, providing a suitable basis for precision panel-meter and digital-indicator measurements.

A dual-slope ADC is a sigma-delta-style integrating converter that repeatedly ramps and measures an input against a fixed reference. The ICL7135 divides each conversion into measuring and integrating phases, rejecting much of the periodic noise found in industrial environments. Its integration period helps average unwanted components of the input while retaining the resolution required for a 4.5-digit display. In the system hierarchy, it is an ADC, an analog-to-digital converter, a data-acquisition IC, and ultimately a semiconductor.

Key features include 4.5-digit resolution, multiplexed BCD outputs suitable for decimal display drivers, differential high-impedance input architecture, and a specified 2.0000 V full-scale range. The multiplexed output interface reduces the number of dedicated output pins by sharing digit and BCD data lines. This makes the device useful for standalone panel meters and digital instruments that need displayed numerical results rather than a conventional binary-coded output for a digital bus.

The ICL7135 separates its analog and digital functions into dedicated circuit areas. The analog section includes the differential input path, integrator, reference comparison, and analog output multiplexing, while the digital section contains counters, timing control, output drivers, and control logic. Its dual-slope architecture supports good noise performance without requiring a high-speed successive-approximation conversion pipeline. Users should nevertheless provide stable reference and input conditions because gain accuracy is tied to reference quality and conversion timing.

Typical uses include digital panel meters, laboratory instruments, weighing systems, process-monitoring equipment, temperature controllers, and laboratory-grade measurement panels where a 4.5-digit BCD display is preferred. The differential inputs can measure bipolar or unipolar signals when the external analog network is designed for the selected reference and full-scale range. In each application, the front-end divider, reference source, input filtering, and display interface remain as important as the converter itself.

For PCB implementation, place the reference and input-network components close to their associated pins, keep digital BCD routes away from sensitive analog nodes, and provide the bypass and filtering specified by the manufacturer datasheet. Confirm timing, polarity, input-range, and BCD-output details against the ICL7135 datasheet before final routing. Commercial availability, current lot status, and a formal quotation should be confirmed through the Request a Quote form on this page.

This product page combines the manufacturer’s converter description with package details, application engineering guidance, and procurement-oriented information. It is designed to help engineers verify the 4.5-digit architecture, BCD display interface, PLCC footprint, reference requirements, and replacement constraints before committing the part to a new instrument design.

Drop-in alternatifler için ICL7135CQI+T — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.

Bu Serideki Variantlar

Yedek parça uyumlu olan aynı serideki modeller ICL7135CQI+T (aynı form faktörü ve ayağa oturma) — farklı olan Package.

Analog Devices
Package: 28-pin PLCC (11.51 mm × 11.51 mm)
İle Karşılaştır ICL7135CQI+T →

Bu ürüne yer değiştirme seçenekleri mevcut değil.

Alternatifleri Talep Edin

ICL7135CQI+T Maksimum Değerlendirmeler & Elektriksel Özellikler

Converter Type Monolithic dual-slope ADC
Çözünürlük 4.5 digits
Number of Channels 1 channel
Input Architecture High-impedance differential inputs
Output Format Multiplexed BCD outputs
Full-Scale Capability 2.0000 V
Accuracy ±1 count in 20,000
Conversion Principle Dual-slope integration
İşletim Sıcaklığı Aralığı 0 °C to +70 °C
Paket 28-pin PLCC, 11.51 mm × 11.51 mm
Pin Sayısı 28 pins
Montaj Türü Surface mount
Shipping Format Tape and reel

ICL7135CQI+T 28-pin plcc, 11.51 mm × 11.51 mm Pin Yapısı Kılavuzu

ICL7135CQI+T (28-pin plcc, 11.51 mm × 11.51 mm paket) için pin yapısı. Bu analog bileşen, giriş, çıkış ve güç besleme pinleri içerir. Ofset null, telafi ve etkinleştirme pin yapılandırmaları için üretici veri kitapçığını referans alın. Sinyal işleme ve güç amplifikasyon devreleri için mükemmel bir bileşendir.

28-pin plcc, 11.51 mm × 11.51 mm paket pin çizelgesi için ICL7135CQI+T

Ayrıntılı pin çıkış verisi mevcut değil: ICL7135CQI+T.

Aşağıdaki veri sayfası tam pin konfigürasyonu için.

Tipik Uygulamalar

ICL7135CQI+T için uygundur 6 uygulamas: Digital Panel Meters, Laboratory Measurement Instruments, Weighing and Load Measurement, Process Monitoring Equipment, Temperature and Pressure Displays, Precision Bench Meters.

📺

Digital Panel Meters

The ICL7135CQI+T fits a precision digital panel meter because it combines a 4.5-digit dual-slope conversion system with multiplexed BCD outputs intended for decimal display hardware. The high-impedance differential inputs can receive a scaled front-end signal while the converter’s specified ±1-count-in-20,000 accuracy supports readable instrumentation results. Use the manufacturer application circuit as the starting point for reference selection, input filtering, timing components, and display-driver interfaces.

🔧

Laboratory Measurement Instruments

The ICL7135CQI+T is appropriate for laboratory-style instruments that present a direct decimal measurement and can tolerate the conversion rate of a dual-slope ADC. Its differential high-impedance input supports front ends built around resistive dividers or sensor bridges, while the 2.0000 V full-scale capability provides a defined reference point for gain design. Accurate results still depend on a low-noise reference, correct input polarity, adequate filtering, and the timing network defined by the manufacturer datasheet.

🏭

Weighing and Load Measurement

The ICL7135CQI+T can serve as the measurement engine in a compact load-cell indicator because its high-impedance differential inputs suit carefully balanced sensor excitation and signal conditioning. The 4.5-digit multiplexed BCD output simplifies connection to decimal display hardware, and the integrating dual-slope method helps average periodic interference around industrial transducers. The analog front end must still provide excitation, common-mode protection, input filtering, and a stable reference while keeping sensitive routes away from digital outputs.

🏭

Process Monitoring Equipment

The ICL7135CQI+T suits process-monitoring equipment where a slowly changing analog signal must be converted into a stable decimal indication. Its integrating conversion cycle helps suppress repetitive interference, and the multiplexed BCD interface reduces the connection burden to common display hardware. The converter should be paired with input protection and filtering appropriate to the industrial signal, while the reference path requires careful layout to prevent drift from degrading the stated measurement accuracy.

🧩

Temperature and Pressure Displays

The ICL7135CQI+T is useful in temperature or pressure instruments designed around a dedicated numerical display rather than a digital communications bus. A bridge or resistive sensor signal can be scaled into the differential input network, while the BCD outputs drive the display section. Because the measured quantity changes slowly, the dual-slope integration period can be advantageous, although conversion latency must be checked against the intended refresh rate and any alarm or control-response requirements.

🔬

Precision Bench Meters

The ICL7135CQI+T can support a dedicated bench meter that prioritizes a readable 4.5-digit result and straightforward BCD display wiring. Its high-impedance differential input architecture permits a flexible analog front end, and the specified 2.0000 V full-scale range gives designers a reference for input-network calculations. To achieve repeatable readings, use a stable reference, shielded or guarded sensitive inputs, appropriate filtering, and a PCB layout that separates the analog and digital sections.

What is the ICL7135CQI+T?
The ICL7135CQI+T is a 4.5-digit, single-channel dual-slope analog-to-digital converter with multiplexed BCD outputs in a 28-pin PLCC package. According to the Analog Devices product page, it uses high-impedance differential inputs, provides ±1-count-in-20,000 accuracy, and supports a 2.0000 V full-scale capability. It is intended for precision digital panel meters and measurement instruments that display decimal results directly.
What are the key specifications of ICL7135CQI+T that engineers should know?
The ICL7135CQI+T provides 4.5-digit resolution, multiplexed BCD outputs, differential high-impedance inputs, ±1-count-in-20,000 accuracy, and a 2.0000 V full-scale capability. The Analog Devices manufacturer datasheet identifies it as a monolithic dual-slope converter. Its 28-pin PLCC package and commercial 0 °C to +70 °C temperature range should be checked against the instrument enclosure, production process, and intended measurement environment before design release.
How does the ICL7135 dual-slope ADC work?
The ICL7135 performs measurement by integrating the unknown input against a reference during successive conversion phases. Its digital counters, control logic, and multiplexed BCD outputs coordinate the measurement sequence and present the converted decimal result. The integrating action averages many input samples, which helps attenuate periodic interference in industrial measurement systems. Reference accuracy, input filtering, and layout remain critical to overall system accuracy.
Where can I download the ICL7135CQI+T datasheet PDF?
The official ICL7135 datasheet and supporting product information are available through the Analog Devices product page at https://www.analog.com/en/products/icl7135.html. Use the manufacturer datasheet for the authoritative pin description, timing diagrams, application circuit, electrical characteristics, and ordering information. The product-page documentation link is the appropriate starting point when the board design requires exact PLCC pin assignments rather than a simplified distributor summary.
Where can I find the ICL7135CQI+T pinout?
The ICL7135CQI+T pinout is defined in the pin-description section of the Analog Devices manufacturer datasheet and corresponds to the 28-pin PLCC footprint. Before assigning PCB nets, verify analog input polarity, reference connections, supply pins, timing-control connections, digit strobes, BCD data outputs, and every exposed or unused PLCC terminal against that table. The 28-pin PLCC drawing is represented by the default package diagram because the package library does not contain a dedicated 28-pin PLCC key.
Is ICL7135CQI+T suitable for a digital panel meter?
Yes, ICL7135CQI+T is suitable for a 4.5-digit digital panel meter because its output is multiplexed BCD rather than a conventional binary bus. The BCD architecture can drive decimal display logic efficiently, while the high-impedance differential input supports carefully scaled front-end networks. A production design should verify conversion timing, reference accuracy, input filtering, display driver compatibility, and the required decimal-point or sign-control behavior.
What is the difference between ICL7135CQI+T and ICL7135CPI+?
The principal verified difference is the package: ICL7135CQI+T is ordered in a 28-pin PLCC tape-and-reel format, while ICL7135CPI+ is listed in a 28-pin PDIP format. Both belong to the ICL7135 family and provide the 4.5-digit multiplexed-BCD conversion function, but the physical lead arrangement and PCB footprint differ. ICL7135CPI+ therefore is not a pin-compatible drop-in replacement for a PLCC board.
Can TLC7135CDWR replace ICL7135CQI+T in an existing design?
No, TLC7135CDWR should not be assumed to be a drop-in replacement for ICL7135CQI+T. The ICL7135CQI+T uses a 28-pin PLCC footprint, whereas TLC7135CDWR is a surface-mount device in a different package, and the available comparison does not establish identical pin mapping. TLC7135 may be useful as a functional alternative when the PCB and surrounding circuit can be redesigned, but it is not a same-footprint replacement.
When should I choose ICL7135CQI+T instead of a binary-output ADC?
Choose ICL7135CQI+T when the instrument needs a local decimal display and can accommodate a multiplexed BCD interface. It integrates the conversion, counting, and display-driving functions expected in a panel-meter design. A binary-output ADC is preferable when the measurement must connect to a microcontroller, serial interface, data logger, or digitally processed signal chain. The ICL7135 advantage is display simplicity rather than modern digital-system connectivity.
What is the best drop-in replacement for ICL7135CQI+T?
No independently verified drop-in replacement was identified for the exact ICL7135CQI+T ordering code. ICL7135CQI+ may share the PLCC device family and converter function, but the non-‘+T’ ordering code represents a different packaging format and is not a distinct engineering alternative. Before substituting any part, verify its 28-pin PLCC footprint, pin functions, reference requirements, timing, BCD output arrangement, and commercial temperature grade.
What can replace ICL7135CQI+T?
A replacement for ICL7135CQI+T must provide the same 28-pin PLCC footprint, pin functions, dual-slope conversion behavior, 4.5-digit multiplexed BCD outputs, and compatible electrical limits. ICL7135CPI+ and TLC7135CDWR are not drop-in choices because their packages differ. If no verified pin-compatible device is available, retain the ICL7135 footprint and qualify an exact-package alternative through the manufacturer datasheet, or redesign the PCB for a different converter architecture.
Is ICL7135CQI+T the same as ICL7135CQI+?
No, ICL7135CQI+T and ICL7135CQI+ are not identical ordering codes. The verified 28-pin PLCC construction and converter description apply to the family, while the target orderable ICL7135CQI+T is identified as tape-and-reel. The ‘+T’ suffix distinguishes the shipping format from the base device ordering code, so procurement should preserve the exact suffix unless the manufacturer confirms that the alternate format meets the assembly requirements.
Where can I buy ICL7135CQI+T online?
Use the Request a Quote form on this page to request current availability, lot traceability, and a formal quotation for ICL7135CQI+T. The manufacturer product page and distributor listings identify the exact 28-pin PLCC tape-and-reel device, but inventory and commercial terms can change. Specify the complete MPN, required quantity, date code, and delivery target so the sourcing request is unambiguous.
What is the price of ICL7135CQI+T?
Submit a quote request through the Request a Quote form on this page for the current ICL7135CQI+T price and volume structure. Pricing for this legacy precision converter depends on quantity, package format, date code, traceability, and market availability. The form is the appropriate route for a current commercial quotation rather than relying on an outdated catalog figure that may not reflect the requested lot or delivery conditions.
What is the lead time and stock status for ICL7135CQI+T?
Request current stock, minimum order quantity, and lead time through the Request a Quote form on this page. The ICL7135CQI+T is an older precision converter, so available inventory may depend on the exact package suffix, manufacturing lot, and regional supply. Include the target quantity and required delivery date in the request. Do not infer availability from a general distributor listing or from the presence of a product page.

Mühendislik referans verileri: ICL7135CQI+T — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.

Seçim Kılavuzu

Choose the ICL7135CQI+T when the product requires a dedicated 4.5-digit decimal display and the measurement changes slowly enough for dual-slope conversion. Its multiplexed BCD interface is especially useful in standalone panel meters because the display wiring remains simpler than with a conventional binary-output ADC. The device is appropriate when a 28-pin PLCC footprint, differential high-impedance inputs, and a stable analog front end are acceptable. Consider an MCP3301-based design instead when the controller needs serial data, higher-resolution data processing, or a more compact mixed-signal interface. Do not select ICL7135CPI+ or TLC7135CDWR for an existing ICL7135CQI+T PCB merely because they implement related measurement functions; their packages differ. No verified same-footprint drop-in substitute was identified, so a replacement decision should prioritize exact pin mapping, reference behavior, conversion timing, BCD outputs, temperature grade, and lifecycle risk.

Alternatiflerle Karşılaştırma

Parametre Bu Ürün
Brand Analog Devices
Package 28-pin PLCC, 11.51 mm × 11.51 mm
Converter Type Monolithic dual-slope ADC
Resolution 4.5 digits
Number of Channels 1 channel
Output Format Multiplexed BCD outputs
Input Architecture High-impedance differential inputs
Full-Scale Capability 2.0000 V
Accuracy ±1 count in 20,000
Operating Temperature Range 0 °C to +70 °C

Tasarım Notları

Separate the analog and digital regions around the ICL7135CQI+T. Keep the reference, input-divider, filtering, and integration components close to their associated pins, and route multiplexed BCD data and digit-strobe signals away from sensitive analog nodes. Use the manufacturer application layout as the reference because small coupling between the two sections can degrade the converter’s apparent noise performance and measurement repeatability.

Design the differential input network for the intended source impedance and input range. High-impedance inputs do not remove the need for balanced routing, guarding, leakage control, and filtering; they instead make those details more important. Verify common-mode limits, input polarity, settling behavior, and conversion timing against the manufacturer datasheet before selecting resistor values or capacitor types.

Do not treat ICL7135CPI+ or TLC7135CDWR as direct replacements for the ICL7135CQI+T PLCC footprint. The PDIP and alternative surface-mount packages require different PCB land patterns. Likewise, do not assume that the base ICL7135CQI+ ordering code is a distinct substitute: its packaging format differs. Preserve the exact suffix unless the assembly process and manufacturer documentation confirm that another ordering code is acceptable.

Uyumluluk Bilgisi

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Kadmiyumdan Arınmış
Unknown
Klorofillerden Arınmış
Unknown
Çatışma Minerali
Unknown

No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was identified for this ordering code. The AEC-Q100 field is not applicable because ICL7135CQI+T is a commercial measurement converter rather than an automotive-qualified device.

Veri doğrulanma tarihi: 2026-11-20 — XAIPART bileşen mühendislik ekibi tarafından doğrulanmış ve derlenmiş veri

İlgili Aramalar

ICL7135CQI+T datasheet ICL7135CQI+T specifications ICL7135CQI+T pinout ICL7135CQI+T datasheet pdf Analog Devices ICL7135CQI+T ICL7135CQI+T PLCC ICL7135CQI+T equivalent ICL7135CQI+T replacement ICL7135CQI+T vs ICL7135CPI+ ICL7135CQI+T vs TLC7135CDWR ICL7135CQI+T price ICL7135CQI+T stock 4.5 digit dual slope ADC ICL7135 panel meter application ICL7135 multiplexed BCD output

İlgili Bileşenler ve Terimler

Analog Devices Maxim Integrated ICL7135CQI+T ICL7135CQI+ ICL7135CPI+ TLC7135CDWR 4.5-digit ADC dual-slope ADC analog-to-digital converter data-acquisition IC semiconductor multiplexed BCD output high-impedance differential input 2.0000 V full scale PLCC-28 surface mount digital panel meter precision measurement reference voltage input filtering process monitoring laboratory instrument
Hızlı Teklif RFQ
Detayları tam doldurun — satış ekibimiz 24 saat içinde yanıt verecek
Parça Numarası Üretici Paket QTY Hedef Fiyat Genişletilmiş
✓
Teklif gönderildi!

24 saat içinde e-postanıza yanıt vereceğiz

1
RFQ Gönderildi
2
Teklif Alındı
3
Sipariş Yerleştirildi
4
Ödeme
5
Gönderildi
6
Teslim Edildi
RFQ Detaylarını Görüntüle