ICL71C03CPI - Precision 4.5-Digit ADC | Harris | DIP-28
部品番号: ICL71C03CPI ✗ 生産終了ICL71C03CPI 概要
An analog-to-digital converter is an ADC, a data-acquisition semiconductor that converts a continuously varying voltage into a numeric representation. Within the wider electronics hierarchy, an ADC is an interface IC used to connect analog measurement circuits with digital processing or display systems. The ICL71C03 belongs to the special-purpose ADC category because it is optimized for precision panel-meter conversion rather than general-purpose high-speed data acquisition.
The principal identified feature is its 4.5-digit conversion resolution, which supports readable measurements over a 19,999-count range when paired with suitable front-end circuitry. The device has one analog input and a flash-conversion structure. Its BCD-oriented output architecture makes it especially useful where decimal digits must be transferred directly to multiplexed displays, reducing the amount of formatting logic required between the converter and display drivers.
The ICL71C03CPI uses a 28-PDIP package and is associated with the Intersil ICL71C03 family. The CPI suffix identifies the specified package and temperature-market variant, while the core ICL71C03 designation denotes the precision 4.5-digit converter. Because this is an older multiplexed display-converter device, system design should account for its external driver requirements, analog input conditioning, reference accuracy, and the operating limits stated in the manufacturer datasheet.
Typical applications include laboratory digital voltmeters, industrial digital panel meters, bench meters, process-monitoring instruments, and dedicated measurement panels. In each case, the ICL71C03CPI converts an analog input into multiplexed decimal information that can drive display digits. The ICL8052A and ICL8068A are identified in the family documentation as suitable output and digit-driver companions.
A critical design consideration is to separate analog input routing from sensitive display-driver and digital timing paths. Decoupling, grounding, input filtering, reference stability, and display-driver layout should be evaluated together because display multiplexing can introduce noise into a precision measurement system. Use the pin-description and test-circuit sections in the manufacturer datasheet when assigning PCB tracks and component values.
This page consolidates the verified package, conversion, application, sourcing, and replacement context for the ICL71C03CPI. It also distinguishes documented family compatibility from unsupported substitutes, helping engineers preserve the original DIP-28 footprint and the specialized BCD display architecture rather than assuming that every superficially similar ADC is a true drop-in replacement.
ドロップイン代替品: ICL71C03CPI — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエストICL71C03CPI 最大定格&電気的特性
| Device Type | Precision 4.5-digit analog-to-digital converter |
| 分解能 | 4.5 digits |
| Equivalent Count Range | 19,999 counts |
| Analog Input Count | 1 input |
| Conversion Architecture | Flash converter |
| Output Format | Multiplexed BCD output |
| Package Type | 28-pin plastic DIP |
| Package Designation | 28-PDIP |
| 実装タイプ | Through-hole |
| RoHS ステータス | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | not_applicable |
ICL71C03CPI 28-pdip ピン配置ガイド
ICL71C03CPI (28-pdip パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: ICL71C03CPI.
詳細は データシート をご参照ください。
主な用途
ICL71C03CPI の用途: 6 件s: Digital Voltmeter, Digital Panel Meter, Bench Measurement Instrument, Process Monitoring Panel, Precision Test Equipment, Legacy Meter Repair.
Digital Voltmeter
The ICL71C03CPI suits a precision DVM because its 4.5-digit flash-conversion architecture is intended to produce decimal measurement information for visible instruments. A practical circuit places the analog measurement node through the required front end, uses the converter's documented reference arrangement, and routes multiplexed BCD output toward the ICL8052A or ICL8068A display-driver stage. The 19,999-count display range provides useful resolution without requiring a general-purpose ADC and numeric formatting controller. Input filtering, reference stability, and layout isolation remain essential because the converter's nominal resolution does not eliminate errors introduced by leakage, grounding, or display-driver noise.
おすすめ
Digital Panel Meter
The ICL71C03CPI is appropriate for an industrial panel-meter front end where one analog channel must be shown as a decimal measurement. The converter's 4.5-digit resolution supports a 19,999-count numeric range, while its multiplexed BCD output reduces the logic burden associated with driving display digits directly. The ICL8068A or ICL8052A can handle the digit-drive stage in a documented instrument arrangement. In an industrial enclosure, the key engineering task is keeping switching currents from the display stage away from the analog input, reference, and converter ground. Stable filtering and controlled grounding can preserve repeatability across temperature and supply variations.
おすすめ
Bench Measurement Instrument
The ICL71C03CPI can form the measurement core of a dedicated bench instrument that emphasizes a readable numeric display rather than high-rate waveform acquisition. Its single analog input and flash-conversion architecture allow a front end to condition a selected voltage before conversion into multiplexed decimal data. This arrangement is useful for laboratory meters, service instruments, and calibration panels where the operator expects a direct four-and-a-half-digit reading. Design the analog channel for the manufacturer's specified input and reference limits, and place filtering and reference components near the device. The display-driver supply and return paths should be separated from the precision analog path to prevent visible measurement shifts.
おすすめ
Process Monitoring Panel
The ICL71C03CPI can monitor a single process variable when the equipment requires a local decimal panel display. A conditioned transmitter or sensor output can feed the converter's analog input, and the multiplexed BCD result can drive the associated digit-driver circuitry for immediate operator feedback. The 4.5-digit, 19,999-count format provides adequate resolution for many pressure, temperature, and position indications without a complex system controller. The implementation should include input protection, filtering, and a stable reference while maintaining the analog and display-current separation required by the datasheet application arrangement. Temperature drift and component tolerances ultimately determine instrument accuracy beyond the converter's resolution.
おすすめ
Precision Test Equipment
The ICL71C03CPI can be used in specialized test equipment where a single precision measurement must be presented as a decimal value. Its dedicated flash-converter architecture and 4.5-digit resolution suit display-oriented instruments such as laboratory meters, reference monitors, and service diagnostics rather than waveform or high-speed sampling systems. The converter should be paired with the ICL8052A or ICL8068A as indicated by the family documentation, allowing the numeric result to reach the visible display efficiently. Accurate results depend on the external reference, input-conditioning network, grounding, and shielding. PCB layout should minimize converter-to-display coupling and keep sensitive input nodes physically separated from multiplexed digit-drive current paths.
おすすめ
Legacy Meter Repair
The ICL71C03CPI is well suited to maintaining an existing instrument that was built around the ICL71C03 display-converter architecture. Its 28-PDIP package supports repair boards and socket-based replacement practices used for older DVM and DPM equipment. Because the part uses one analog input and multiplexed BCD output, a replacement must also reproduce the original reference, supply, timing, and display-driver connections rather than merely fit the socket visually. Before installation, compare every connection against the exact manufacturer pin-description table and inspect the device for correct marking and lead alignment. This application is particularly relevant where replacing the original converter with a modern ADC would require a different board and display interface.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ICL71C03CPI — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 |
|---|---|
| Package | 28-PDIP |
| Brand | Harris Corporation |
| Device Type | Precision 4.5-digit ADC |
| Resolution | 4.5 digits |
| Equivalent Count Range | 19,999 counts |
| Analog Input Count | 1 input |
| Conversion Architecture | Flash converter |
| Output Format | Multiplexed BCD output |
| Display Driver Companion | ICL8052A or ICL8068A |
| Mounting Type | Through-hole |
主な差別化要因
- Purpose-built precision display conversion (vs General-purpose 28-PDIP ADC)
- Direct decimal display architecture (vs Binary-output ADC)
- Single-input flash conversion (vs Successive-approximation ADC)
設計ノート
Separate the precision analog path from the multiplexed display-driver path. Route the converter input, reference, and ground connections as a compact analog group, and keep display digit-drive currents out of that group. Place the required input and reference components close to their associated pins according to the manufacturer application circuit. Because the ICL71C03 is a flash converter for precision displays, coupling from the digit drivers can appear directly as measurement instability.
Treat the reference source as part of the measurement accuracy chain. Use the voltage range and stability specified by the manufacturer and avoid long, high-impedance reference routes. Input filtering should suppress unwanted noise without introducing excessive settling time, while source impedance and leakage must remain within the device's documented operating conditions. Verify the finished instrument across temperature and supply variation because the 4.5-digit resolution alone does not guarantee 4.5-digit accuracy.
Do not assume that the base ICL71C03 is a drop-in replacement for every ICL71C03 suffix code. Package, temperature grade, and ordering configuration can change across suffix variants, and the product family includes related options in packages other than the 28-PDIP. For a repair, compare every pin function and timing signal with the exact manufacturer datasheet. Also account for the display-driver interface and reference circuit; a generic 4.5-digit ADC with a different output format is not a functional drop-in solution.
Plan the analog and display supplies according to the exact limits in the manufacturer datasheet. Decoupling should be placed at the relevant supply pins, and ground returns from the display drivers should not share narrow analog return paths with the converter. Check the power dissipation using the actual output state and supply voltage rather than a nominal package rating. This is especially important in compact panel instruments where display currents and ambient temperature can increase component stress.
コンプライアンス情報
No manufacturer compliance declaration for the exact ICL71C03CPI orderable MPN appears in the available information. Request current compliance documentation before production use.