ICS650G-40 Ethernet Switch Clock Source | Integrated Circuit Systems
部品番号: ICS650G-40 ✓ 生産中ICS650G-40 概要
A clock synthesizer is a type of frequency-generation IC used to derive stable timing signals from a common reference. Within the product hierarchy, the ICS650G-40 belongs to the clock and timing IC family, which sits within interface and network-clocking systems. Ethernet switches require multiple related clocks for transceiver interfaces, switching logic, packet processing, and system management. A programmable clock source allows one reference oscillator to support several clock domains while reducing the number of discrete timing components.
The principal feature of the ICS650G-40 is its phase-locked-loop architecture. The PLL can divide or multiply the input reference to produce the output frequencies selected through the device's output-select interface. Its 25 MHz reference input provides a common timing foundation for Ethernet switch clock trees. The 1:3 ratio associated with related ICS650G-40 variants provides a useful implementation option when the required system clock is three times the reference frequency.
This clock source is intended specifically for Ethernet switch applications rather than general-purpose timing distribution. Its integrated PLL can reduce the number of separate dividers and oscillators needed around a switching ASIC. The 16-TSSOP package identified for related ICS650G-40A variants also reflects a compact surface-mount format appropriate for communications equipment, although engineers should verify the exact land pattern and pin assignment for the ordering code being placed on the PCB.
Typical uses include core-clock generation for Ethernet switching silicon, clock-tree support in network interface cards, and timing generation in managed or unmanaged switching platforms. The device can be especially useful where several subsystems must operate from one 25 MHz crystal reference while requiring selectable output-clock options.
PCB design should preserve short, clean clock traces and provide a stable reference source with appropriate grounding. Keep sensitive oscillator and PLL traces away from high-current switching nodes, and use the manufacturer pin-description table to assign every signal correctly. Confirm output frequency, enable behavior, supply requirements, and load capability against the datasheet before releasing a production layout.
This product page combines the Ethernet clock-source function, PLL characteristics, package considerations, application guidance, and substitution constraints into an engineering-focused guide. It also distinguishes verified drop-in candidates from suffix-only ordering options that should not be assumed to be interchangeable without package and pin verification.
ドロップイン代替品: ICS650G-40 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
ICS650G-40A
✅ ドロップイン📋 参考代替品(カタログ未掲載)
ICS650-40
✅ ドロップイン📋 参考代替品(カタログ未掲載)
ICS650G-40ALF
✅ ドロップイン📋 参考代替品(カタログ未掲載)
ICS650G-40 最大定格&電気的特性
| Device Type | Clock/frequency synthesizer and Ethernet switch clock source |
| PLL | Yes |
| Input Type | Clock and crystal |
| 出力タイプ | Clock |
| Number of Circuits | 1 |
| Nominal Crystal Input Frequency | 25 MHz |
| Maximum Listed Frequency | 25 MHz |
| Input-to-Output Ratio | 1:3 |
| Clocking Technology | Phase-locked loop |
| Primary Application | Ethernet switch clock source |
| Related Variant Package | 16-TSSOP, 0.173 inch (4.40 mm) width |
| Mounting Method | Surface mount |
| RoHS ステータス | unknown |
| REACH Status | unknown |
ICS650G-40 16-tssop, 0.173 inch (4.40 mm) width ピン配置ガイド
ICS650G-40 (16-tssop, 0.173 inch (4.40 mm) width パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: ICS650G-40.
詳細は データシート をご参照ください。
主な用途
ICS650G-40 の用途: 6 件s: Ethernet Switching ASIC Clocking, Managed Network Switch Platform, Network Interface Card Timing, Telecommunications Ethernet Equipment, Industrial Ethernet Control System, Ethernet Media Converter.
Ethernet Switching ASIC Clocking
The ICS650G-40 is appropriate for supplying a central timing reference to an Ethernet switching ASIC that needs related clocks derived from a single source. Its PLL-based architecture accepts a 25 MHz crystal reference and offers selectable clock outputs, allowing the switching fabric and associated interface blocks to use a coordinated timing plan. The 1:3 ratio associated with the family can support systems where a three-times-reference clock is required. Design the clock tree to keep routing short, maintain controlled return paths, and separate this low-level timing network from switching power stages and high-current data paths.
おすすめ
Managed Network Switch Platform
A managed Ethernet switch can use the ICS650G-40 as a compact clock source for switching logic, packet-processing blocks, and interface-related timing. Using a 25 MHz crystal reference as the common origin simplifies synchronization compared with distributing several unrelated oscillators. The PLL architecture permits selectable output frequencies, which helps designers adapt one timing component to multiple internal clock domains. Place the device near the switching ASIC clock inputs, keep the crystal path short, and verify ground-return continuity so reference and PLL signals remain predictable under switching loads.
おすすめ
Network Interface Card Timing
The ICS650G-40 can support timing generation in a network interface card that includes Ethernet switching or multiple interface-clock domains. A 25 MHz crystal supplies the reference, while the PLL produces selectable outputs for controller, interface, and status timing. This approach can reduce discrete clock-component count and centralize frequency selection. Because Ethernet interfaces may combine high-speed data routing with sensitive clock edges, isolate the oscillator network from connector and magnetics-related return currents, use a controlled reference layout, and validate the complete timing budget against the interface ASIC requirements.
おすすめ
Telecommunications Ethernet Equipment
In telecommunications Ethernet equipment, the ICS650G-40 can serve as a dedicated clock source for switching subsystems requiring coordinated, selectable frequencies. Centralizing timing around a 25 MHz crystal reference supports repeatable board-level clock distribution and simplifies identification of the timing origin during troubleshooting. The device should be placed according to the manufacturer reference layout, with its supply, ground, crystal, and output paths kept away from high-current switching stages. Confirm operating-temperature grade and supply limits for the equipment enclosure before approving the exact ordering suffix.
おすすめ
Industrial Ethernet Control System
The ICS650G-40 is suitable for industrial Ethernet switching blocks that require a stable reference and selectable clock outputs in a compact surface-mount footprint. The 25 MHz crystal input provides a clear timing source for the controller and communication interfaces, while PLL-derived outputs reduce the number of independent timing chains. Place the clock device close to the circuitry that consumes its outputs and route its reference connections away from motors, relays, and power-conversion stages. Use the manufacturer pin and electrical tables to establish bypass capacitance, grounding, and operating limits for the specific controller platform.
おすすめ
Ethernet Media Converter
A compact Ethernet media converter can use the ICS650G-40 when it contains several clock-consuming blocks requiring a common reference. Deriving selectable outputs from a 25 MHz crystal can simplify synchronization between the network interface, conversion logic, and status-control electronics. The component's clock-only function makes it best suited to digital timing support rather than analog signal conditioning. Keep the reference oscillator mechanically stable, provide a low-impedance ground connection, and review output loading and frequency accuracy in the manufacturer datasheet before finalizing the board layout.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ICS650G-40 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | ICS650G-40A | ICS650-40 | ICS650G-40ALF |
|---|---|---|---|---|
| Brand | Integrated Circuit Systems | Renesas Electronics | Integrated Circuit Systems | Renesas Electronics |
| Device Type | Clock/frequency synthesizer and Ethernet switch clock source | Clock/frequency synthesizer | Ethernet switch clock chip | Clock generator, PLL, frequency synthesizer |
| Output Type | Clock | Clock | Selectable output clock frequencies | Clock |
| PLL | Yes | Yes | Yes | Yes |
| Primary Application | Ethernet switch clock source | Ethernet switch core clock | Ethernet switch clock source | Ethernet clock generation |
主な差別化要因
- Purpose-built Ethernet switch clock-source function (vs ICS650G-40A)
- Common 25 MHz crystal reference architecture (vs ICS650-40)
- Established 16-TSSOP family option (vs ICS650G-40ALF)
設計ノート
Place the ICS650G-40 close to the switching ASIC or other clock-consuming circuitry, and route each clock output directly to its destination. Keep the 25 MHz crystal path and PLL connection compact, provide an uninterrupted ground reference, and avoid routing the oscillator network beneath or alongside high-current switching nodes. The physical placement and grounding arrangement are critical because clock-edge displacement and reference noise can affect system-level timing even when nominal output frequencies are correct.
Use the manufacturer datasheet to determine the supply voltage, input capacitance, bypass requirements, and allowable output loading before finalizing the power network. Place required bypass capacitors at the corresponding device pins with short ground returns, and keep switching-regulator loops away from the crystal and PLL traces. Validate the clock source across minimum, nominal, and maximum switching loads because a board that clocks correctly at startup may still show timing errors when Ethernet traffic changes the power-system load.
Do not select a replacement from the part-number family alone. Verify package dimensions, pin numbering, power and ground assignments, crystal connection, Output Select truth table, output frequencies, supply limits, temperature grade, and clock-loading requirements. In particular, suffixes such as A, ALF, T, and ALFT may distinguish ordering, grade, or packaging information rather than adding a new function. A drop-in decision should be documented against the exact manufacturer pin table and electrical limits.
コンプライアンス情報
No definitive environmental or automotive qualification statements were identified for the exact ICS650G-40 ordering code.