Renesas Electronics

ICS651MIT - 1-to-4 200 MHz Clock Buffer | Renesas

部品番号: ICS651MIT ✓ 生産中
1.425 V to 2.625 V Vdss 8-SOIC, 3.90 mm width Package 200 MHz Speed
MOQ: 1 |

ICS651MIT 概要

Renesas Electronics ICS651MIT is a low-skew 1-to-4 fanout clock buffer with a maximum operating frequency of 200 MHz and a supply-voltage range of 1.425 V to 2.625 V. The device is packaged in an 8-SOIC measuring 3.90 mm wide and is designed to distribute one input clock across four outputs while limiting output-to-output timing skew.

A clock fanout buffer is a clock-and-timing integrated circuit that replicates a periodic signal to multiple destinations. Within the broader semiconductor hierarchy, it belongs to clock and timing ICs, then clock buffers and drivers, and ultimately digital logic. Unlike a clock generator, it does not create a new reference frequency; instead, it buffers an existing clock so multiple circuits can receive controlled copies with predictable timing relationships.

The primary features of ICS651MIT are its 1-to-4 fanout architecture, 200 MHz maximum frequency, and 1.425 V to 2.625 V operating supply range. These characteristics make it suitable for low-voltage digital systems that need to distribute a common clock among processors, memory controllers, communication circuits, or custom logic. Its low-skew design helps limit the difference in arrival time between the four buffered outputs.

ICS651MIT belongs to the ICS ClockBlocks family and is positioned as a small, low-skew clock buffer. The 8-SOIC package provides a compact surface-mount implementation for applications that do not require the zero-delay or PLL-based functions offered by more complex clock products. Each buffered output should be treated as a separate clock load, so trace length, loading, and downstream capacitance remain important considerations.

Typical uses include clock distribution in communications equipment, digital logic subsystems, processor clock trees, and embedded control systems. In a multi-destination design, the single clock input can feed four independently routed outputs, reducing duplicated clock-generation circuitry. The part is especially relevant where several sequential circuits must operate from the same timing reference on a low-voltage supply.

Layout quality directly affects clock integrity in a fanout network. Place the input and output decoupling capacitors close to their associated pins, keep output routes short where possible, and avoid routing clock signals through noisy analog or switching-power regions. Maintain a continuous return path beneath or adjacent to each clock trace and observe the device's recommended input and output loading limits from the manufacturer datasheet.

This product page organizes the core electrical characteristics, package information, application guidance, datasheet access, and design considerations for ICS651MIT. It also identifies where replacement verification requires a direct comparison of pinout, supply voltage, frequency, output behavior, and propagation delay before any substitute is approved for production.

ドロップイン代替品: ICS651MIT — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

この製品に利用可能なドロップイン代替品はありません。

代替品をリクエスト

ICS651MIT 仕様

Device Type Fanout Buffer (Distribution)
Fanout Ratio 1 input to 4 outputs
Maximum Frequency 200 MHz
Input Signal Type Clock
Output Signal Type Clock
Supply Voltage Range 1.425 V to 2.625 V
パッケージ 8-SOIC, 3.90 mm width
実装タイプ Surface mount
Packaging Tape & Reel
Product Family ICS ClockBlocks

ICS651MIT 8-soic, 3.90 mm width ピン配置ガイド

ICS651MIT (8-soic, 3.90 mm width パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。

ICS651MIT の 8-soic, 3.90 mm width パッケージピン配置図

詳細なピン配置データはありません: ICS651MIT.

詳細は データシート をご参照ください。

主な用途

ICS651MIT の用途: 6 件s: Processor Clock Distribution, Communications Equipment Clocking, Embedded Control Subsystems, Memory Interface Clock Fanout, Industrial Control Logic, FPGA and Custom Logic Clock Trees.

🖥️

Processor Clock Distribution

The ICS651MIT fits processor clock trees that need one source signal distributed to several destinations. Its 1-to-4 fanout architecture reduces the number of separate clock buffers required when a processor, controller, memory interface, and peripheral logic must share a common reference. The 200 MHz maximum frequency supports medium-speed digital systems, while the 1.425 V to 2.625 V supply range allows integration into compatible low-voltage logic domains. Route each output according to its assigned load, preserve a continuous ground reference, and verify propagation-delay and skew requirements in the timing budget.

🌐

Communications Equipment Clocking

The ICS651MIT is useful in communications equipment where several digital sections require synchronized copies of a common clock. A single 1-to-4 fanout stage can feed routing logic, interface circuitry, and control blocks without generating four unrelated clock references. Its 200 MHz operating ceiling accommodates common intermediate-speed digital clocking, and its low-skew positioning helps control output arrival-time differences. Keep clock routes away from switching regulators and high-speed data lanes, and confirm that each destination's input capacitance remains within the manufacturer loading guidance.

🧩

Embedded Control Subsystems

ICS651MIT can distribute a system clock among an embedded controller, memory, programmable logic, and external interface circuitry. The 8-SOIC package provides a compact surface-mount implementation for boards where conserving area matters, while the 1-to-4 topology simplifies clock routing compared with duplicating source circuits. The device's 1.425 V to 2.625 V operating range is suitable for low-voltage digital domains, subject to the exact system requirements. Validate setup and hold relationships at every destination because propagation delay and output-to-output skew remain part of the end-to-end timing analysis.

🖥️

Memory Interface Clock Fanout

The ICS651MIT can provide separate clock branches to memory and interface logic that require a common low-skew timing reference. Its four outputs allow routing decisions to be made according to destination loading rather than forcing one electrical branch to serve unrelated functions. Operation up to 200 MHz makes the device applicable to many external memory and digital-interface clock trees, provided the interface's own maximum frequency is not higher. Use matched routing where branch timing must remain balanced, and validate input and output timing against the Renesas operating characteristics.

🏭

Industrial Control Logic

ICS651MIT fits industrial control boards that distribute a common clock among sequencing logic, acquisition paths, and communication interfaces. Low-skew fanout helps maintain consistent command timing across multiple circuit sections, while the 1.425 V to 2.625 V supply range supports low-voltage digital designs. The 200 MHz rating is sufficient for many control and interface circuits, but it does not replace individual device timing checks. Protect clock integrity by isolating traces from motor-control switching nodes, maintaining a solid return plane, and following the recommended decoupling and output-loading requirements.

⚡

FPGA and Custom Logic Clock Trees

The ICS651MIT is applicable to FPGA and custom-logic clock trees that need one input distributed across up to four clock domains. The 1-to-4 fanout can provide separate branches for programmable logic, serial interface, control, and status blocks, reducing fanout stress on the original clock source. The 200 MHz ceiling is suitable for many general-purpose digital fabrics, although the target FPGA may specify a higher clock limit. Confirm pinout, input thresholds, output loading, and timing margins before insertion, and route each branch for the load it will actually drive.

What is the ICS651MIT?
The ICS651MIT is a Renesas Electronics low-skew, 1-to-4 clock fanout buffer operating up to 200 MHz. It accepts one clock input and provides four buffered clock outputs, making it suitable for distributing a common timing reference within a low-voltage digital system. According to the Renesas ICS651 datasheet, the device belongs to the ICS ClockBlocks family and is packaged in an 8-SOIC.
What is the operating voltage of ICS651MIT?
The ICS651MIT operates from 1.425 V to 2.625 V. This range places the buffer in low-voltage digital-clock environments and allows it to share the supply domain of compatible processors, controllers, and logic. The manufacturer datasheet should be used to confirm voltage tolerances, input thresholds, output levels, and operating-temperature limits before the device is used in a new design.
What is the maximum frequency of ICS651MIT?
The ICS651MIT supports clock signals up to 200 MHz. That maximum frequency makes the device appropriate for distributing common clocks among medium-speed digital logic, communications circuitry, and processor subsystems. The 200 MHz rating should be distinguished from skew and propagation-delay specifications, which are separate timing parameters and should be checked in the Renesas ICS651 datasheet for the final clock-tree design.
How many outputs does ICS651MIT provide?
The ICS651MIT provides four clock outputs from one clock input. This 1-to-4 fanout arrangement allows one source clock to feed as many as four destination circuits without using four separate input buffers. The four outputs should be routed according to their assigned loads, with attention paid to output capacitance, trace length, and return-path continuity to preserve clock quality.
Where can I download the ICS651MIT datasheet PDF?
The official ICS651 datasheet is available through the Renesas Electronics document page at https://www.renesas.com/document/dst/651-datasheet. It is the appropriate source for the pin-description table, timing characteristics, recommended operating conditions, and package drawing. Use the ordering-code information to verify that the document corresponds to the ICS651MIT temperature and packing option.
Where can I find the ICS651MIT pinout?
The ICS651MIT pinout is identified in the pin-description table and package drawing in the Renesas ICS651 datasheet. The component uses an 8-SOIC package, but individual pin numbers and signal names are not reproduced on this page because that information was not available for independent transcription. Use the manufacturer document directly when assigning PCB tracks, especially for input, output, power, and ground connections.
What are the key specifications of ICS651MIT that engineers should know?
The key ICS651MIT specifications are a 1-to-4 clock fanout configuration, 200 MHz maximum operating frequency, and a 1.425 V to 2.625 V supply-voltage range. The device is a low-skew buffer in the ICS ClockBlocks family and uses an 8-SOIC package. These parameters establish its basic clock-tree role, while the Renesas datasheet provides the detailed timing, loading, and recommended-application limits.
What can replace ICS651MIT?
A genuine replacement for ICS651MIT must be a pin-compatible 1-to-4 clock buffer in an 8-SOIC package with a 200 MHz-or-higher frequency rating and an operating range that covers 1.425 V to 2.625 V. No verified substitute MPN was identified in the available cross-reference results, so a replacement should not be selected from a generic similarity list. Compare the candidate's pinout, output logic, propagation delay, skew, load limits, and supply tolerances before approval.
Is ICS651MIT suitable for clock distribution?
Yes, ICS651MIT is specifically designed as a low-skew 1-to-4 clock distribution buffer. Its 200 MHz maximum frequency and 1.425 V to 2.625 V operating range fit low-voltage digital clock trees. Suitability depends on the required frequency, skew, output loading, propagation delay, and clock topology, all of which should be evaluated against the manufacturer's timing characteristics and the PCB implementation.
When should I choose ICS651MIT instead of a PLL clock generator?
Choose ICS651MIT when the system already has a suitable clock source and only needs four low-skew copies of that signal. Its 1-to-4 fanout function is simpler than a PLL-based generator, which is preferable when frequency multiplication, programmable output frequencies, jitter shaping, or clock recovery is unnecessary. A PLL or other generator should be selected when the system must create or manipulate the reference frequency itself.
Is ICS651MIT the same as a zero-delay buffer?
No. The ICS651MIT is identified as a low-skew clock fanout buffer, not as a zero-delay buffer. It replicates one clock input across four outputs but does not inherently provide the added delay compensation associated with a zero-delay-buffer product. Verify the candidate device's specified propagation delay and skew behavior against the system timing budget rather than treating all 1-to-4 clock buffers as functionally identical.
How should ICS651MIT be used in a four-load clock tree?
Connect the source clock to the ICS651MIT input and route its four outputs to the intended destination circuits. Place input and output bypass capacitors close to their pins, keep clock traces short, and provide a continuous ground reference beneath or adjacent to each route. Confirm each output's capacitive loading and edge-rate requirements in the manufacturer datasheet because the four outputs may have differing trace loads.
What design considerations matter for ICS651MIT clock integrity?
Clock integrity for the ICS651MIT depends on trace geometry, output loading, supply decoupling, and ground-return continuity. Keep the input route short and isolate it from switching nodes and high-current return paths. Use a solid ground plane, avoid split planes beneath clock routes, and match output branches where timing balance matters. The 200 MHz maximum rating does not eliminate the need to control rise time, loading, and crosstalk in the layout.
Where can I request a quote for ICS651MIT?
Use the Request a Quote form on this page to request current pricing, availability, lead time, and order confirmation for ICS651MIT. The available channel information does not contain a qualifying quantity-break price table for the exact MPN, so no price figure is asserted. Include your required quantity, target delivery date, and packaging preference with the request to obtain an actionable commercial response.
Is ICS651MIT in stock and what is its lead time?
Current stock and production lead time for the exact ICS651MIT MPN should be confirmed through the Request a Quote form on this page. The part is associated with current distributor and manufacturer listings, but those listings do not establish a guaranteed stock quantity or dated lead-time commitment for every order. A formal quotation can confirm allocation, minimum order quantity, and expected delivery without relying on an unverified inventory claim.
What is the best Renesas equivalent for ICS651MIT?
The best Renesas equivalent must be verified directly against the ICS651MIT family rather than inferred from a similar catalog entry. Required attributes include an 8-SOIC footprint, matching pin assignments, one clock input, four clock outputs, at least 200 MHz operation, and coverage of the 1.425 V to 2.625 V supply range. The available cross-reference results did not identify a qualified Renesas substitute, so no unsupported MPN is recommended.
Is ICS651MIT compliant with RoHS and REACH?
The RoHS and REACH status of ICS651MIT should be confirmed from the current Renesas product documentation or the material-compliance declaration associated with the exact ordering code. Those declarations were not available for transcription here, so this page does not assign a compliance result that might be inaccurate. For a regulated production release, obtain the relevant declaration and document the exact package suffix used in the shipment.

エンジニアリング参考データ: ICS651MIT — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the ICS651MIT when a design already has a suitable clock source and needs one input distributed to as many as four destinations in a low-voltage digital system. Its 200 MHz maximum frequency, 1.425 V to 2.625 V supply range, and low-skew 1-to-4 architecture make it appropriate for processor, communications, memory-interface, embedded-control, and custom-logic clock trees. Do not select it when the design requires frequency synthesis, programmable PLL outputs, clock recovery, or true zero-delay compensation. No verified pin-compatible substitute was identified, so a replacement should not be chosen solely from a generic parametric similarity result. Any proposed alternative must match the 8-SOIC footprint, pin assignments, output count, supply range, frequency capability, loading, logic levels, propagation delay, and skew requirements. For new layouts, also verify that the four output branches can be routed with controlled impedance, return-path continuity, and acceptable capacitive loading.

代替品との比較

パラメータ この製品
Device Type Fanout Buffer (Distribution)
Fanout Configuration 1 input to 4 outputs
Maximum Frequency 200 MHz
Supply Voltage Range 1.425 V to 2.625 V
Input Signal Type Clock
Output Signal Type Clock
Package 8-SOIC, 3.90 mm width
Brand Renesas Electronics

主な差別化要因

  • Four buffered outputs from one clock source (vs No verified drop-in alternative)
  • Compact low-voltage clock distribution (vs No verified drop-in alternative)
  • Low-skew multi-output architecture (vs No verified drop-in alternative)

設計ノート

Place the input bypass capacitor and output bypass capacitors close to the associated ICS651MIT pins and ground pads. Keep the clock-input trace short, and route the four outputs directly toward their destinations rather than creating shared stubs. When branch lengths differ substantially, review propagation-delay and skew impact in the system timing budget and use matched routing where the destination devices require closely aligned clocks.

Keep clock traces on a continuous ground reference and avoid crossing plane splits, high-current switching nodes, and unrelated high-speed data lanes. A solid reference plane limits loop area and reduces susceptibility to common-mode noise. If the board includes a separate analog region or a DC-DC converter, maintain controlled spacing between the clock route and those power-conversion paths to minimize coupling into the timing signal.

Treat each of the four outputs as a separate branch with its own capacitive and resistive loading. Confirm input slew rate, output loading, and clock-frequency requirements against the Renesas datasheet before finalizing the schematic. A clean 200 MHz square wave at the source does not guarantee acceptable edge quality at the destination, so confirm the complete source-to-load path with appropriate simulation or measurement.

Do not treat ICS651MIT as a PLL clock generator or a zero-delay buffer; it is a low-skew one-to-four fanout device. Likewise, the 200 MHz maximum is not a guarantee that every output can drive any load at that frequency. Review output loading, pin assignments, supply voltage, and downstream setup-and-hold requirements in the manufacturer datasheet, then validate timing on the assembled board.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

No exact RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration for the ICS651MIT ordering code was available for transcription. Obtain the current manufacturer compliance declaration before use in a regulated production release.

データ検証日: 2026-11-11 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

ICS651MIT datasheet ICS651MIT specifications ICS651MIT pinout ICS651MIT datasheet pdf ICS651MIT clock buffer ICS651MIT 200 MHz ICS651MIT 1-to-4 fanout ICS651MIT SOIC-8 ICS651MIT equivalent ICS651MIT replacement ICS651MIT price ICS651MIT stock Renesas ICS651MIT ICS651MIT clock distribution

関連部品&用語

Renesas Electronics ICS651MIT ICS651 ICS ClockBlocks clock fanout buffer clock buffer clock and timing IC digital logic IC semiconductor 1-to-4 fanout 200 MHz 1.425 V to 2.625 V 8-SOIC surface mount SMD package clock distribution low-skew clocking propagation delay output skew clock integrity embedded control communications equipment FPGA custom logic
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示