ISL8483IB-T - Half-Duplex RS-422/RS-485 Transceiver | Renesas
部品番号: ISL8483IB-T ✓ 生産中ISL8483IB-T 概要
A half-duplex RS-422/RS-485 transceiver is a physical-layer interface IC that converts digital logic-level signals into differential bus signals and converts received differential signals back into logic levels. Within the interface hierarchy, the ISL8483IB-T belongs to the transceiver class of interface ICs, combining an RS-422/RS-485 driver, an RS-422/RS-485 receiver, and bus-facing control functions in one package. Differential signaling supports reliable communication over longer cable runs while reducing sensitivity to common-mode noise.
The verified manufacturer-related listing identifies the ISL8483IB-T as a one-driver, one-receiver, half-duplex RS-422/RS-485 transceiver in an 8-SOIC package. Its principal engineering benefits are component consolidation, a compact surface-mount footprint, and support for both RS-422 and RS-485 point-to-point networks. The single driver and receiver arrangement also helps designers manage bus direction explicitly in half-duplex systems.
The part is appropriate for industrial controllers, factory automation equipment, remote sensor interfaces, and embedded communications modules. In these systems, the transceiver connects a host UART or programmable controller to a differential bus while converting logic signals to and from the physical network. The 8-pin SOIC package supports conventional PCB assembly methods and is smaller than many legacy through-hole transceiver packages.
Designers should verify the final electrical limits, receiver fail-safe behavior, driver enable polarity, and bus termination requirements against the manufacturer datasheet before releasing production hardware. In half-duplex implementations, correct driver-enable timing is essential to prevent contention, while proper biasing and termination help maintain signal integrity on the RS-422 or RS-485 network.
This page combines the verified Renesas product identity, exact package classification, interface capability, sourcing information, available drop-in references, and practical implementation guidance. It is intended to help engineers identify the correct device, plan PCB connections, and compare compatible RS-422/RS-485 interface options before detailed circuit validation.
ドロップイン代替品: ISL8483IB-T — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: ISL8483IB-T (同一形状・フットプリント) — 相違点: Package, Product Type, Receiver Count, Supported Standards.
ISL8483IBZ-T
✅ ドロップイン📋 参考代替品(カタログ未掲載)
ISL8483IB
✅ ドロップイン価格はお問い合わせください
データシートを見る →ISL8483IB-T 仕様
| Product Type | RS-422/RS-485 half-duplex transceiver |
| Channel Count | 1 channel |
| Driver Count | 1 driver |
| Receiver Count | 1 receiver |
| Duplex Mode | Half-duplex |
| Supported Standards | RS-422 and RS-485 |
| パッケージ | 8-pin SOIC |
| 実装タイプ | Surface mount |
ISL8483IB-T 8-pin soic ピン配置ガイド
ISL8483IB-T (8-pin soic パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: ISL8483IB-T.
詳細は データシート をご参照ください。
主な用途
ISL8483IB-T の用途: 6 件s: Industrial Controller RS-485 Interface, Factory Automation Sensor Node, Remote Sensor and Telemetry Link, Instrumentation and Measurement Equipment, Building and HVAC Control Module, Embedded Serial Communication Bridge.
Industrial Controller RS-485 Interface
The ISL8483IB-T fits an industrial controller that must communicate over an RS-485 bus while conserving board area. Its one-driver, one-receiver arrangement provides the physical-layer functions required for bidirectional half-duplex communication, and the 8-SOIC package offers a compact surface-mount footprint. The controller must deassert driver enable before receiving and apply the timing specified in the manufacturer datasheet. RS-485 bus design also requires correct termination at the physical ends of the network and suitable biasing where required.
おすすめ
Factory Automation Sensor Node
The ISL8483IB-T can connect a compact factory sensor node to a fieldbus-style differential network when the node uses a half-duplex RS-422 or RS-485 physical layer. The single driver and single receiver architecture provides bidirectional communication through one compact 8-SOIC device. Keep the bus connection isolated from noisy motor and relay wiring, use a defined logic state while the driver is disabled, and validate the transceiver against the cable length, baud rate, and termination arrangement used in the installation.
おすすめ
Remote Sensor and Telemetry Link
The ISL8483IB-T is suitable for a remote telemetry link that exchanges commands and measurements over a differential bus. Half-duplex operation allows the same wiring to support both directions, while the 8-SOIC package keeps the interface compact enough for distributed instrumentation. The receiving software must allow sufficient turnaround time after changing bus direction. At the PCB level, route the differential pair as a tightly coupled pair, keep stubs short, and follow the recommended grounding and protection arrangement for the target installation.
おすすめ
Instrumentation and Measurement Equipment
The ISL8483IB-T can provide the differential bus interface in laboratory or process instrumentation that must communicate with a host over RS-422 or RS-485. Combining one driver and one receiver in an 8-SOIC package reduces component count compared with separate transmit and receive devices when the bus is operated half-duplex. Use controlled direction timing and verified termination to minimize signal integrity issues. Check the exact input sensitivity, common-mode range, and supply requirements in the manufacturer datasheet before matching it to high-precision front-end circuitry.
おすすめ
Building and HVAC Control Module
The ISL8483IB-T fits distributed HVAC and building-control modules that communicate with a controller over a wired RS-485 or RS-422 network. Its one-channel half-duplex configuration supports bidirectional command and status exchange, and the small 8-SOIC package leaves space for sensors, relays, and power conversion circuitry. Firmware should enforce a quiet interval and bus turnaround before reversing transmission direction. Protection components and grounding must be selected for the installation environment rather than added solely by signal amplitude.
おすすめ
Embedded Serial Communication Bridge
The ISL8483IB-T can serve as the differential interface stage in an embedded serial bridge that converts a host UART into RS-422 or RS-485. The 8-SOIC package and integrated one-driver, one-receiver arrangement support a compact implementation without requiring separate driver and receiver ICs. The bridge firmware must manage the enable signal so the transmitter is active only while data is being sent. Add termination, protection, and filtering according to the cable environment, and verify operation at the intended data rate and cable length.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ISL8483IB-T — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | ISL8483IBZ-T | ISL8483IB |
|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Transceiver Type | RS-422/RS-485 half-duplex transceiver | RS-422/RS-485 half-duplex transceiver | RS-422/RS-485 transceiver |
| Channel Count | 1 channel | 1 channel | 1 channel |
| Driver and Receiver Count | 1 driver, 1 receiver | 1 driver, 1 receiver | 1 driver, 1 receiver |
| Duplex Mode | Half-duplex | Half-duplex | Half-duplex |
| Supported Standards | RS-422 and RS-485 | RS-422 and RS-485 | RS-422 and RS-485 |
| Measured Parameter Difference | Reference device | 0% difference in compared primary performance ratings | 0% difference in compared electrical performance |
主な差別化要因
- Single-package half-duplex RS-422/RS-485 interface (vs ISL8483IB)
- Direct same-family replacement path (vs ISL8483IBZ-T)
- Compact 8-SOIC integration (vs ISL8483IBZ-T)
設計ノート
Route the differential bus conductors as a closely coupled pair and minimize stub lengths between the transceiver and connector. Place termination components at the physical endpoints of the bus rather than at every node. For half-duplex operation, verify that the driver is disabled before the receiver path is enabled and that firmware observes an adequate bus-turnaround interval.
Use the manufacturer pin-description table and typical application layout when assigning the 8-SOIC connections. Keep the device-control traces away from the differential bus pair, maintain a continuous ground reference beneath the interface section, and place any decoupling capacitors directly between the appropriate supply and ground pins with short traces. This reduces susceptibility to switching noise and helps preserve a defined bus state.
Do not treat every RS-422 or RS-485 transceiver as a drop-in replacement solely because it uses an 8-SOIC package. Confirm supply voltage, logic thresholds, driver enable polarity, receiver enable polarity, bus impedance, maximum data rate, common-mode range, and fail-safe behavior against the manufacturer datasheet. Also verify whether the network is point-to-point RS-422 or multipoint RS-485 before selecting biasing and protection.
Keep the communication interface physically separated from switching regulators, relays, motors, and high-di/dt traces. If the cable interface is exposed to industrial transients, add protection selected for the installation's surge, ESD, and ground-potential requirements. Maintain a controlled ground strategy so protection currents do not flow through sensitive logic paths or the differential pair.
コンプライアンス情報
No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact ISL8483IB-T ordering code. Confirm environmental and quality documentation with Renesas before production release.