Texas Instruments

LT1014CN - 4-Channel 5V-44V Precision Op Amp | Texas Instruments

部品番号: LT1014CN ✓ 生産中
5 V to 44 V Vdss 14-pin PDIP (N) Package
MOQ: 1 |

LT1014CN 概要

The Texas Instruments LT1014CN is a four-channel precision operational amplifier with a 5 V to 44 V total supply range, 1 MHz gain-bandwidth product, and 14-pin PDIP package. It supports single 5 V operation and dual ±15 V operation, while its input common-mode range includes ground. The device is intended for low-power precision instrumentation, battery-powered measurement systems, strain-gauge amplifiers, thermocouple amplifiers, current-loop transmitters, threshold detectors, and active filters.

An operational amplifier is an analog integrated circuit that uses high open-loop gain to amplify the difference between two input voltages. When negative feedback is applied, the closed-loop circuit determines the gain and bandwidth. The LT1014 belongs to the precision operational-amplifier hierarchy, where low offset voltage, low temperature drift, low noise, and low supply current are important for preserving the integrity of small sensor signals. Four amplifiers are integrated into one 14-pin DIP, reducing board area compared with four separate single or dual packages.

The LT1014CN provides an input offset voltage of 300 µV maximum at 25 °C and an input offset voltage temperature coefficient of 2.5 µV/°C maximum for the LT1014 family. Its 1 MHz gain-bandwidth product and 0.4 V/µs slew rate support general-purpose precision signal conditioning. Its low-power architecture and 5 V single-supply compatibility are useful when supply energy is constrained. The common-mode input range extends to ground, allowing the device to process signals close to the lower supply rail.

The LT1014 uses an industry-standard 14-pin quad operational-amplifier configuration, with four complete amplifier sections and a no-connect position on pin 8. This arrangement supports straightforward printed-circuit-board layout in the familiar PDIP footprint. The device can be used without external compensation in ordinary closed-loop configurations, although gain, noise, output swing, load capability, and stability should be evaluated for each application. Its precision characteristics are more useful than a general-purpose amplifier when sensor outputs are small and drift matters over time.

Typical applications include bridge-based strain and pressure measurement, thermocouple signal conditioning, precision current-loop receivers, low-level active filters, multiple-threshold detection, and battery-operated instrumentation. The four independent channels can process several related signals in one package, such as four transducer outputs or a mixed set of amplification, filtering, and comparison functions. The LT1014CN is also useful when both positive and negative supplies are available, because it can operate at dual ±15 V while retaining precision operation.

Designers should verify input and output voltage limits, load current, common-mode range, noise, and stability against the worst-case supply voltage and temperature. Input and output decoupling should be placed close to the relevant supply pins, and unused amplifier sections should be configured according to the manufacturer recommendations rather than left floating. Because the package is a PDIP rather than a surface-mount package, it also requires adequate spacing for through-hole assembly and appropriate lead-bend clearance.

This product record combines verified manufacturer and distributor information, same-footprint alternatives, pricing status, and practical selection guidance. It highlights the LT1014CN's 5 V to 44 V supply range, four precision channels, 1 MHz bandwidth, 300 µV offset limit, and 14-pin PDIP footprint to support faster engineering selection than a distributor listing alone.

ドロップイン代替品: LT1014CN — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: LT1014CN (同一形状・フットプリント) — 相違点: Number of Channels, Amplifier Type, Mounting Type, Input Offset Voltage, Operating Temperature Range.

Texas Instruments
Number of Channels: 4 (Quad)
比較対象 LT1014CN →
Texas Instruments
Number of Channels: 2
Amplifier Type: General Purpose, Dual Channel
Mounting Type: Surface Mount
比較対象 LT1014CN →

LT1014ACN

✅ ドロップイン ⚠️ 仕様未検証
📦 14-PDIP (N)
LT1014A precision grade versus LT1014 grade; exact offset, drift, and temperature-grade differences require comparison

📋 参考代替品(カタログ未掲載)

LT1014ADN

✅ ドロップイン ⚠️ 仕様未検証
📦 14-PDIP (N)
LT1014A precision grade versus LT1014 grade; exact offset, drift, and temperature-grade differences require comparison

📋 参考代替品(カタログ未掲載)

LT1014DN

✅ ドロップイン
Texas Instruments
📦 14-PDIP (N)
4 (Quad) · Precision Operational Amplifier · 5 V to 44 V · ±2.5 V to ±22 V · 50 µV · 0.3 µV/°C · 0.15 nA · 8,000,000 (8 million)

価格はお問い合わせください

データシートを見る →

LT1014DIN

✅ ドロップイン
📦 14-PDIP (N)
Same LT1014 family and 44 V total supply rating; ordering and temperature-grade differences require verification

📋 参考代替品(カタログ未掲載)

MC1458D

✅ ドロップイン
Texas Instruments
📦 14-PDIP (N)
Texas Instruments · MC1458 · General Purpose, Dual Channel · 2 · 0.5 V/us (typical) · 1 MHz · 1 mV (typical at 25 C) · 30 nA (typical)

価格はお問い合わせください

データシートを見る →

LT1014CN 最大定格&電気的特性

Amplifier Type Precision operational amplifier
Number of Channels 4 channels
Total Supply Voltage Range 5 V to 44 V
Single-Supply Operation 5 V
Dual-Supply Operation ±15 V
Gain-Bandwidth Product 1 MHz
Slew Rate 0.4 V/µs
Input Offset Voltage 300 µV maximum at 25 °C
Input Offset Voltage Temperature Coefficient 2.5 µV/°C maximum
Common-Mode Input Voltage Range Includes ground
Output Voltage Swing Includes ground while sinking current
動作温度範囲 0 °C to 70 °C
パッケージ 14-pin PDIP (N)
ピン数 14 pins
実装タイプ Through-hole

LT1014CN ピン構成

DIP-14 Package Pinout Diagram DIP-14 14-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 14 2 13 3 12 4 11 5 10 6 9 7 8 DIP-14
ピン 1 OUT A — Amplifier A output
ピン 2 IN A- — Amplifier A inverting input
ピン 3 IN A+ — Amplifier A non-inverting input
ピン 4 V- — Negative supply connection
ピン 5 IN B+ — Amplifier B non-inverting input
ピン 6 IN B- — Amplifier B inverting input
ピン 7 OUT B — Amplifier B output
ピン 8 NC — Not connected
ピン 9 OUT C — Amplifier C output
ピン 10 IN C- — Amplifier C inverting input
ピン 11 IN C+ — Amplifier C non-inverting input
ピン 12 V+ — Positive supply connection
ピン 13 IN D+ — Amplifier D non-inverting input
ピン 14 IN D- — Amplifier D inverting input

主な用途

LT1014CN の用途: 6 件s: Battery-Powered Precision Instrumentation, Strain-Gauge Signal Conditioning, Thermouple Amplifier, 4 mA to 20 mA Current-Loop Receiver, Active Precision Filter, Threshold Detection and Limit Monitoring.

🔋

Battery-Powered Precision Instrumentation

The LT1014CN fits battery-powered measurement equipment because it combines a 5 V single-supply capability with low supply current, high open-loop gain, low noise, and low offset drift. Its common-mode input range includes ground, allowing signals close to the supply return to be amplified without requiring a bipolar input arrangement. Four precision channels in one 14-pin PDIP also reduce the component count in portable instruments. The primary benefit is measurement stability: the specified 300 µV maximum input offset at 25 °C and 2.5 µV/°C maximum drift are more useful than general-purpose amplifier figures when the battery-powered sensor produces a small differential signal. Designers should still confirm the actual supply current and noise density before calculating battery life.

🏭

Strain-Gauge Signal Conditioning

The LT1014CN is suitable for strain-gauge front ends where the useful bridge differential signal is small and offset drift can compromise the measurement. Its 300 µV maximum input offset at 25 °C helps preserve resolution, while the 1 MHz gain-bandwidth product provides more bandwidth than many precision instrumentation amplifiers require. The four channels can support bridge excitation buffering, amplifier stages, and filtering functions within one package. The common-mode input range including ground is particularly useful when the bridge output is referenced close to the lower rail in a single-supply system. Input bias current, input common-mode limits at the actual bridge excitation voltage, and resistor-generated noise should be checked before finalizing the gain and compensation network.

🌡️

Thermouple Amplifier

The LT1014CN can amplify thermocouple signals when low offset and thermal stability are more important than very high bandwidth. The specified 300 µV maximum offset at 25 °C and 2.5 µV/°C maximum drift help limit errors in the microvolt-to-millivolt range produced by many thermocouples, while the 0.4 V/µs slew rate is adequate for typical temperature-loop and measurement update rates. The common-mode input range includes ground, which supports low-side sensing arrangements. Designers should use a cold-junction compensation approach, account for input bias current, and keep input wiring short to reduce thermoelectric errors. The four channels also allow one package to handle several temperature inputs when those channels share suitable grounding and compensation requirements.

🌐

4 mA to 20 mA Current-Loop Receiver

The LT1014CN fits precision current-loop receivers because the input common-mode voltage range includes ground and the device operates from a single 5 V supply. These characteristics simplify the interface to sensors that generate a 4 mA to 20 mA current signal when the shunt resistor is referenced to the lower supply rail. The 300 µV maximum offset at 25 °C and 2.5 µV/°C maximum drift help maintain accuracy as the received current is converted into voltage. Four amplifier sections can implement a receiver, filter, buffer, or auxiliary threshold function. The design must confirm the maximum common-mode voltage at the actual loop supply, verify output swing at the selected shunt value, and assess input bias current because it produces voltage error across the shunt.

🎛️

Active Precision Filter

The LT1014CN can implement active filters and multiple gain blocks where low offset reduces output error near the signal floor. Its 1 MHz gain-bandwidth product gives useful closed-loop bandwidth for low-frequency measurement, instrumentation, and audio-adjacent precision applications, while the 0.4 V/µs slew rate supports the output transitions normally required by moderate-bandwidth filters. Four amplifier sections allow cascading stages without requiring separate dual packages. Component tolerances and the op amp's finite gain-bandwidth product determine the actual filter response, so simulation should include both rather than treating the ideal transfer function as exact. The device's low-power operation and 5 V single-supply support also make it suitable for compact, battery-operated filter modules.

📈

Threshold Detection and Limit Monitoring

The LT1014CN is appropriate for threshold detection and multiple-limit monitoring because four amplifier channels are integrated into a single 14-pin package. The low input offset helps reduce ambiguity when comparing a slowly changing sensor signal with a reference, while the common-mode range including ground supports thresholds near the lower supply rail. Each channel can implement a comparator-like function with feedback or an open-loop detector, subject to the output-swing and stability requirements of the selected topology. The 5 V single-supply option simplifies portable monitoring equipment. Engineers should check output saturation levels, input over-range behavior, noise around the threshold, and whether the measured signal requires true comparator rail-to-rail performance; the LT1014 is an amplifier rather than a dedicated comparator.

おすすめ製品の概要

LT1014DN Texas Instruments 使用用途: Battery-Powered Precision Instrumentation, Thermouple Amplifier, Active Precision Filter MC1458D Texas Instruments 使用用途: Battery-Powered Precision Instrumentation, 4 mA to 20 mA Current-Loop Receiver LT1014ACN Same-family precision-grade alternative for bridge amplification 使用用途: Strain-Gauge Signal Conditioning, 4 mA to 20 mA Current-Loop Receiver, Threshold Detection and Limit Monitoring LT1014ADN Same-family precision-grade alternative for multi-channel conditioning 使用用途: Strain-Gauge Signal Conditioning, Threshold Detection and Limit Monitoring LT1014DIN Same-family ordering option for compatible instrumentation 使用用途: Thermouple Amplifier, Active Precision Filter
What is the operating voltage of LT1014CN?
The LT1014CN operates from a 5 V to 44 V total supply range and supports both 5 V single-supply and dual ±15 V operation. According to the Texas Instruments LT1014 product information, its common-mode input range includes ground, making it suitable for low-level signals referenced near the lower supply rail. Designers should still verify output swing and load current at the exact supply voltage used in the circuit.
What are the key specifications of LT1014CN that engineers should know?
The LT1014CN is a four-channel precision operational amplifier with a 5 V to 44 V supply range, 1 MHz gain-bandwidth product, 0.4 V/µs slew rate, and 14-pin PDIP package. According to the Texas Instruments LT1014 product page, it provides low offset-voltage temperature coefficient, high gain, low supply current, and low noise. The specified input offset voltage is 300 µV maximum at 25 °C.
Where can I buy LT1014CN online?
The LT1014CN is available through major electronics distributors, including DigiKey and Mouser. The verified DigiKey listing identifies it as a standard general-purpose amplifier with four circuits in a 14-pin PDIP, while the Mouser listing categorizes it as a quad precision operational amplifier. Current unit pricing and stock quantities are not included in the supplied data, so request a quotation before committing the component to a production bill of materials.
What is the price of LT1014CN?
The current verified price of LT1014CN is not available in the supplied distributor excerpts, so no numerical price can be stated reliably. DigiKey and Mouser provide product and purchasing pages for the device, but the captured snippets do not expose an amount or dated price tier. Check the distributor listing for a quote as of 2026-10-28, including stock, manufacturer lead time, and authorized-channel status.
What is the lead time for LT1014CN?
The manufacturer lead time for LT1014CN is not specified in the supplied verified data, although DigiKey's listing states that the part can be purchased and shipped. Because distributor availability can change independently of the manufacturer's production schedule, request current stock and lead time as of 2026-10-28 before fixing the delivery plan. For scheduled production, also review the TI product page for any lifecycle or ordering changes.
Is LT1014CN in stock?
The verified DigiKey snippet states that LT1014CN can be bought and shipped today, but it does not provide a numerical stock count. Treat this as an indication that the distributor lists the device for purchase, not as a guaranteed inventory quantity. Confirm the live quantity and lead time on the distributor page as of 2026-10-28 before placing a production order.
Where can I download the LT1014CN datasheet PDF?
The authoritative LT1014CN documentation is available through the Texas Instruments LT1014 product page at https://www.ti.com/product/LT1014. The verified search results also identify an LT1014CN PDF on Alldatasheet, with a listed file size of 631 kbytes and 30 pages. For controlled engineering review, use the manufacturer-linked datasheet and the ordering information for the N-package variant.
Where can I find the LT1014CN pinout?
The LT1014CN uses the industry-standard 14-pin quad operational-amplifier configuration. Pins 1 through 7 and 9 through 14 form four complete amplifier channels, with pin 8 designated NC. According to the manufacturer information supplied for the product family, the device is available in a PDIP (N) package with 14 pins. The complete pin assignment is reproduced in the pinout table on this product page.
What can replace LT1014CN on the same 14-pin footprint?
LT1014ACN, LT1014ADN, LT1014DN, and LT1014DIN are same-family Texas Instruments candidates associated with the 14-pin industry-standard configuration, while MC1458D is an earlier-generation alternative identified by the manufacturer literature. Exact stock and ordering conditions vary, and the LT1014A versions provide different precision specifications. Verify the required temperature grade and offset limits before substituting any part.
Is MC1458D the same as LT1014CN?
MC1458D is a related quad precision operational amplifier, but it is not electrically identical to the LT1014CN. According to the Analog Devices LT1014 product information, the LT1014 is an upgrade to industry-standard parts including the MC1458 and MC1558. MC1458D uses a 14-pin DIP and can serve as a family-level alternative, although offset, drift, supply-current, noise, and availability should be compared before replacement.
What is the best Analog Devices equivalent for LT1014CN?
The LT1014 itself is now presented on Analog Devices' product page, which describes the quad precision amplifier and its battery-powered instrumentation applications. The verified data does not identify a separate modern Analog Devices competitor with a confirmed 14-pin PDIP footprint and all required LT1014CN ratings. Engineers should therefore treat the documented LT1014 family variants and MC1458D as the supported comparison set rather than assume an unverified modern equivalent.
LT1014CN vs LT1014DN - which should I choose?
LT1014CN and LT1014DN are both associated with the LT1014 family and 14-pin PDIP configurations, but their ordering, temperature, and possibly grade conditions must be checked independently. The verified comparison identifies both parts as four-channel precision amplifiers with a 44 V maximum total supply voltage. Compare the manufacturer's ordering tables for exact temperature range and parameter differences before treating LT1014DN as a drop-in replacement.
When should I choose LT1014CN instead of a general-purpose quad op amp?
Choose LT1014CN when low-level signals require lower offset and temperature drift than a general-purpose quad amplifier provides. The device's 300 µV maximum offset at 25 °C, 2.5 µV/°C maximum drift, common-mode range including ground, and 5 V single-supply operation favor precision instrumentation. A general-purpose amplifier may cost less, but its larger input error can dominate the measurement if the sensor output is small.
Is LT1014CN suitable for battery-powered instrumentation?
The LT1014CN is suitable for battery-powered precision instrumentation because it supports a 5 V single supply and is described by the manufacturer as having low supply current, high gain, low noise, and low offset drift. Its common-mode input range extends to ground, helping process signals near the supply return. Actual battery-life calculations require the device-specific supply current at the selected operating voltage, which is not provided in the verified excerpts.
What design considerations apply when using the LT1014CN?
The LT1014CN requires attention to supply bypass, input common-mode range, output swing, load current, and closed-loop stability. Place decoupling capacitors close to the supply pins, keep sensitive input traces short, and avoid driving loads outside the device's rated output range. According to the manufacturer application information, the common-mode range includes ground and the output can swing toward ground while sinking current, which is advantageous for single-supply sensor interfaces.

エンジニアリング参考データ: LT1014CN — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the LT1014CN for compact precision instrumentation using four independent channels, especially when the circuit uses a 5 V single supply, dual ±15 V, or an input common-mode range extending to ground. Its 300 µV maximum offset at 25 °C and 2.5 µV/°C maximum drift favor it over general-purpose quad amplifiers in sensor and current-loop measurements. Choose LT1014ACN or LT1014ADN when the manufacturer data confirms that the A-grade precision characteristics better meet the measurement error budget. Choose LT1014DN or LT1014DIN when their specific ordering and temperature conditions are preferable for the same LT1014 architecture. MC1458D is a legacy-family option, but it should be selected only after confirming offset, drift, noise, bias-current, and supply-current requirements. In every case, validate stability, common-mode limits, output swing, and thermal behavior at the actual supply voltage and temperature.

代替品との比較

パラメータ この製品 LT1014ACN LT1014ADN LT1014DN LT1014DIN MC1458D
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 14-PDIP (N) 14-PDIP (N) 14-PDIP (N) 14-PDIP (N) 14-PDIP (N) 14-PDIP (N)
Number of Amplifiers 4 4 4 4 4 4

主な差別化要因

  • Four precision amplifiers in one 14-pin PDIP (vs MC1458D)
  • Single 5 V and dual ±15 V operation (vs LT1014DIN)
  • Precision offset specification (vs MC1458D)
  • Broad supply headroom (vs LT1014DN)

設計ノート

Place input and output decoupling capacitors close to the supply pins and keep sensitive inverting-input traces short. Because the LT1014CN is a precision amplifier, input bias current and resistor noise can create meaningful error at high source impedances. Use a low-value feedback resistor only when required by bias-current or bandwidth calculations, and keep the non-inverting input path away from switching nodes and high-current return paths.

Evaluate the complete signal path at both single 5 V and dual ±15 V operation because the common-mode range includes ground but the usable output range is not rail-to-rail. Confirm that sensor inputs remain inside the common-mode limits at the lowest supply voltage and that the required output does not saturate under the worst-case load. Add supply-bypass capacitance near the device and avoid long high-impedance supply connections.

Do not use the LT1014CN as an unrestricted comparator without checking output saturation, overdrive recovery, and stability around the threshold. The device is a low-power operational amplifier, not a rail-to-rail comparator, and its intended linear operation assumes suitable negative feedback. For unused amplifier channels, follow the manufacturer's recommended termination configuration instead of allowing floating inputs.

Before replacing LT1014CN with LT1014ACN, LT1014ADN, LT1014DN, LT1014DIN, or MC1458D, compare exact offset voltage, drift, input bias current, noise, common-mode range, output swing, supply current, and temperature grade. Although all candidates are associated with the 14-pin industry-standard configuration, a footprint match alone does not guarantee equivalent measurement accuracy or regulatory suitability.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The supplied manufacturer and distributor excerpts do not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable because the LT1014CN is a general-purpose commercial-temperature operational amplifier rather than an automotive-qualified device.

データ検証日: 2026-10-28 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

LT1014CN LT1014CN datasheet PDF Texas Instruments LT1014CN LT1014CN 14-pin PDIP LT1014CN 5V 44V quad op amp LT1014CN pinout LT1014CN precision instrumentation amplifier LT1014CN battery powered instrumentation LT1014CN vs LT1014DN LT1014CN drop-in replacement LT1014CN price buy LT1014CN online LT1014CN lead time and stock what can replace LT1014CN

関連部品&用語

Texas Instruments LT1014CN LT1014ACN LT1014ADN LT1014DN LT1014DIN MC1458D LT1014 precision operational amplifier quad operational amplifier low-dropout operational amplifier analog integrated circuit semiconductor 14-pin PDIP PDIP package family through-hole package 5 V single-supply operation dual ±15 V operation common-mode input voltage range input offset voltage input offset voltage temperature coefficient gain-bandwidth product slew rate battery-powered instrumentation strain-gauge signal conditioning thermocouple amplifier 4 mA to 20 mA current loop active filter threshold detection
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示