部品番号: LT1102ACH ✗ 生産終了LT1102ACH 概要
An instrumentation amplifier is a differential amplifier optimized for measuring small signals embedded in larger common-mode voltages. Its internal architecture provides differential input, high input impedance, and fixed gain without an external gain-setting resistor. In the component hierarchy, the LT1102ACH belongs to the instrumentation-amplifier and operational-amplifier families within analog and power-management integrated circuits.
The LT1102ACH combines less than 10 pA input bias current with a 180 µV input offset voltage. Its input bias currents also do not double for every 10°C temperature increase, helping preserve measurement accuracy across changing operating temperatures. These characteristics make the device useful when a sensor or transducer produces a low-level differential signal and common-mode voltage rejection is essential.
Speed is another defining feature. The LT1102 provides improved slew rate, settling time, gain-bandwidth product, and overdrive recovery compared with competitive high-speed instrumentation amplifiers. A 30 V/µs slew rate helps preserve amplitude and phase accuracy in fast transient measurements. Because the gain is fixed, no external resistor network is required, reducing component count and gain-setting variation.
Typical applications include precision bridge excitation and readout, high-speed data acquisition, laboratory instrumentation, industrial process measurement, medical sensor interfaces, and low-current photodetection. The JFET inputs are particularly appropriate when source impedance is high or leakage from guarding, cabling, or nearby circuitry could corrupt the measurement.
When laying out the LT1102ACH, use short input paths and appropriate guarding because high-impedance inputs are sensitive to leakage and parasitic capacitance. Maintain symmetric routing around the differential inputs, provide clean supply bypassing, and verify settling time against the selected fixed gain. The TO-5 metal package also requires careful consideration of thermal paths in enclosed or elevated-temperature systems.
This page consolidates the manufacturer’s stated performance characteristics, package details, application guidance, and drop-in replacement information into an engineering-oriented reference for precision signal-chain design.
ドロップイン代替品: LT1102ACH — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: LT1102ACH (同一形状・フットプリント) — 相違点: Input Bias Current, Input Offset Voltage, Mounting Type, Package, Product Type.
LT1102AH
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
LT1102ACH 最大定格&電気的特性
| Product Type | Single-circuit instrumentation amplifier |
| Input Transistor Technology | JFET input |
| Fixed Gain Options | 10 or 100 V/V |
| Gain Accuracy | 0.01% |
| Nonlinearity | 3 ppm |
| Input Offset Voltage | 180 µV |
| Input Bias Current | <10 pA |
| Slew Rate | 30 V/µs |
| パッケージ | TO-5 metal can, 8 pins |
| ピン数 | 8 pins |
| 実装タイプ | Through-hole |
| External Gain-Setting Resistor | Not required |
| Output Offset Voltage Contribution | None |
| Input Bias Current Temperature Behavior | Does not double for each 10°C temperature increase |
LT1102ACH to-5 metal can, 8 pins ピン配置ガイド
LT1102ACH (to-5 metal can, 8 pins パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: LT1102ACH.
詳細は データシート をご参照ください。
主な用途
LT1102ACH の用途: 6 件s: Precision Bridge Transducer Readout, High-Speed Data Acquisition, Low-Current Photodetection, Laboratory Instrumentation, Medical Sensor Signal Conditioning, Industrial Process Monitoring.
Precision Bridge Transducer Readout
The LT1102ACH fits precision bridge and strain-gauge readout circuits because its JFET inputs draw less than 10 pA, helping minimize current through high-resistance sensing elements. The fixed gain of 10 or 100 removes the need for an external gain-setting resistor and supports repeatable scaling with 0.01% gain accuracy. Its 180 µV offset voltage is small relative to many low-level transducer outputs, while the 30 V/µs slew rate improves response to sensor steps. Place the amplifier close to the bridge and guard the high-impedance input traces to minimize leakage and parasitic pickup.
おすすめ
High-Speed Data Acquisition
The LT1102ACH is useful in high-speed data-acquisition front ends that must preserve transient information rather than merely amplify a slow DC signal. Its 30 V/µs slew rate, improved settling behavior, fixed-gain operation, and 3 ppm nonlinearity support faithful acquisition of short events across the selected gain range. The 8-pin TO-5 package also provides a compact through-hole solution for instrumentation systems. Keep supply and reference paths short, and validate input-referred settling and overdrive recovery for the actual acquisition bandwidth before finalizing the analog front end.
おすすめ
Low-Current Photodetection
The LT1102ACH suits low-current photodetection because its less-than-10-pA JFET input bias current creates a small error relative to weak sensor currents. The fixed gain of 10 or 100 can condition a photodiode or phototransistor signal without external gain resistors, while the 180 µV offset specification helps control input-referred error. Place the amplifier near the detector to reduce leakage from cables and connectors, use guarded traces, and confirm photodiode capacitance against the amplifier’s settling requirements. Reverse or bipolar detector protection should be designed separately around the input stage.
おすすめ
Laboratory Instrumentation
The LT1102ACH supports laboratory measurement systems that combine high source impedance with demanding gain stability. Its JFET input stage draws less than 10 pA, reducing loading of sensors and probes, while 0.01% gain accuracy and 3 ppm nonlinearity improve scale-factor confidence. Fixed gains of 10 and 100 simplify channel configuration and reduce external resistor-count variation. For bench instruments, use guarded PCB inputs, clean connectors, symmetrical differential routing, and local supply bypassing. Confirm the device’s exact supply and temperature limits from the manufacturer datasheet for the intended operating environment.
おすすめ
Medical Sensor Signal Conditioning
The LT1102ACH can condition differential outputs from high-impedance medical sensors when leakage, offset, and gain stability are important. Its less-than-10-pA input bias current minimizes disturbance of weak biopotential or sensor currents, while the 180 µV offset and 0.01% gain accuracy establish a low-error amplification baseline. The 30 V/µs slew rate also supports faster physiological signal waveforms. Medical designs still require application-specific isolation, protection, leakage verification, and regulatory review; none of those safety functions are provided by the amplifier package itself.
おすすめ
Industrial Process Monitoring
The LT1102ACH is appropriate for industrial process-monitoring channels that must separate small differential signals from substantial common-mode voltage. The precision gain of 10 or 100, 0.01% gain accuracy, and 3 ppm nonlinearity improve measurement repeatability, while JFET inputs accommodate high source impedances without loading the sensor heavily. The 30 V/µs slew rate provides useful response margin when process variables change quickly. Use robust input protection, guarded high-impedance routing, local decoupling, and an enclosure design that limits moisture and contamination, particularly in long-life industrial environments.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: LT1102ACH — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | LT1102AH |
|---|---|---|
| Package | TO-5 metal can, 8 pins | TO-5 metal can, 8 pins |
| Brand | Analog Devices | Analog Devices |
| Product Type | Fixed-gain instrumentation amplifier | Fixed-gain instrumentation amplifier |
| Fixed Gain Options | 10 or 100 V/V | 10 or 100 V/V |
| Gain Accuracy | 0.01% | 0.01% |
| Nonlinearity | 3 ppm | 3 ppm |
| Input Offset Voltage | 180 µV | 180 µV |
| Input Bias Current | <10 pA | <10 pA |
| Slew Rate | 30 V/µs | 30 V/µs |
主な差別化要因
- Fixed-gain accuracy without an external gain-setting resistor (vs LT1102AH)
- Low-leakage JFET input stage (vs LT1102AH)
- Precision signal conditioning with fast large-signal response (vs LT1102AH)
設計ノート
Route the two differential inputs symmetrically and place the LT1102ACH close to the source. High-impedance JFET inputs can couple leakage and injected noise even though the specified bias current is below 10 pA. Use grounded guarding around sensitive nodes where PCB area permits, avoid test-point contamination, and keep connector and relay contacts away from the input path. Clean the assembled board and control moisture when operating below the device’s temperature limits.
Decouple each supply connection as close as practical to the relevant LT1102ACH pins, and follow the manufacturer’s recommended capacitor values and ESR characteristics. Confirm the exact operating supply range before applying rails. Because this is a fixed-gain precision instrumentation amplifier, supply noise and ground movement can become input-referred errors even when the signal itself is small. Check power-supply sequencing, return-current paths, and the noise bandwidth relevant to the intended measurement bandwidth.
Validate settling time at the selected fixed gain rather than relying only on the 30 V/µs slew-rate figure. Fast slew rate reduces large-signal transition time, but final accuracy also depends on small-signal settling, overdrive recovery, capacitance, and system layout. Measure both a full-scale step and a small perturbation around the operating level. For sensors with substantial capacitance, minimize lead length and consider guarding or a suitable isolation strategy.
The 8-pin TO-5 metal-can construction provides a robust thermal path, but its performance still depends on how the device is mounted. Keep the can accessible to ambient convection when the amplifier dissipates appreciable power, and avoid placing it beside heat sources that increase its case or ambient temperature. Verify the operating-temperature grade of the exact ordering code and calculate worst-case dissipation from the actual supply, output voltage, and load current before sealing the assembly.
コンプライアンス情報
The manufacturer product information identifies an instrumentation amplifier but does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for LT1102ACH. AEC-Q100 is not applicable to this precision analog amplifier.