Analog Devices

LT1102ACH - High-Speed JFET Instrumentation Amplifier | ADI

MPN: LT1102ACH ✗ Cuối đời
180 µV Vdss <10 pA Id TO-5 metal can, 8 pins Package
MOQ: 1 |

LT1102ACH Tóm tắt

The Analog Devices LT1102ACH is a high-speed, precision JFET-input instrumentation amplifier with a fixed gain of 10 or 100, 0.01% gain accuracy, and 3 ppm nonlinearity. It is packaged in an 8-pin TO-5 metal-can package for applications requiring low input bias current, low offset voltage, and fast signal settling.

An instrumentation amplifier is a differential amplifier optimized for measuring small signals embedded in larger common-mode voltages. Its internal architecture provides differential input, high input impedance, and fixed gain without an external gain-setting resistor. In the component hierarchy, the LT1102ACH belongs to the instrumentation-amplifier and operational-amplifier families within analog and power-management integrated circuits.

The LT1102ACH combines less than 10 pA input bias current with a 180 µV input offset voltage. Its input bias currents also do not double for every 10°C temperature increase, helping preserve measurement accuracy across changing operating temperatures. These characteristics make the device useful when a sensor or transducer produces a low-level differential signal and common-mode voltage rejection is essential.

Speed is another defining feature. The LT1102 provides improved slew rate, settling time, gain-bandwidth product, and overdrive recovery compared with competitive high-speed instrumentation amplifiers. A 30 V/µs slew rate helps preserve amplitude and phase accuracy in fast transient measurements. Because the gain is fixed, no external resistor network is required, reducing component count and gain-setting variation.

Typical applications include precision bridge excitation and readout, high-speed data acquisition, laboratory instrumentation, industrial process measurement, medical sensor interfaces, and low-current photodetection. The JFET inputs are particularly appropriate when source impedance is high or leakage from guarding, cabling, or nearby circuitry could corrupt the measurement.

When laying out the LT1102ACH, use short input paths and appropriate guarding because high-impedance inputs are sensitive to leakage and parasitic capacitance. Maintain symmetric routing around the differential inputs, provide clean supply bypassing, and verify settling time against the selected fixed gain. The TO-5 metal package also requires careful consideration of thermal paths in enclosed or elevated-temperature systems.

This page consolidates the manufacturer’s stated performance characteristics, package details, application guidance, and drop-in replacement information into an engineering-oriented reference for precision signal-chain design.

Bộ thay thế dễ dàng lắp đặt cho LT1102ACH — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với LT1102ACH (cùng hình factor và footprint) — khác nhau ở Input Bias Current, Input Offset Voltage, Mounting Type, Package, Product Type.

Analog Devices
Input Bias Current: < 10 pA
Input Offset Voltage: 180 uV
Mounting Type: Through-hole, hermetic sealed
So sánh với LT1102ACH →

LT1102AH

✅ Drop-In ⚠️ Thông số chưa được xác minh
📦 TO-5 metal can, 8 pins
Same 8-pin TO-5 footprint and 180 µV offset-voltage class; operating-temperature grade differs and must be verified

📋 Tham chiếu thay thế (không có trong danh mục)

LT1102ACH Tỷ lệ tối đa & tính chất điện

Product Type Single-circuit instrumentation amplifier
Input Transistor Technology JFET input
Fixed Gain Options 10 or 100 V/V
Gain Accuracy 0.01%
Nonlinearity 3 ppm
Input Offset Voltage 180 µV
Input Bias Current <10 pA
Slew Rate 30 V/µs
Hộp TO-5 metal can, 8 pins
Số chân 8 pins
Kiểu lắp đặt Through-hole
External Gain-Setting Resistor Not required
Output Offset Voltage Contribution None
Input Bias Current Temperature Behavior Does not double for each 10°C temperature increase

Hướng dẫn cấu hình chân LT1102ACH to-5 metal can, 8 pins

Cấu hình chân cho LT1102ACH (to-5 metal can, 8 pins gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.

Bảng cấu hình chân to-5 metal can, 8 pins cho LT1102ACH

Không có dữ liệu chân cụ thể sẵn có cho LT1102ACH.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

LT1102ACH phù hợp cho 6 Áp dụngs: Precision Bridge Transducer Readout, High-Speed Data Acquisition, Low-Current Photodetection, Laboratory Instrumentation, Medical Sensor Signal Conditioning, Industrial Process Monitoring.

🏭

Precision Bridge Transducer Readout

The LT1102ACH fits precision bridge and strain-gauge readout circuits because its JFET inputs draw less than 10 pA, helping minimize current through high-resistance sensing elements. The fixed gain of 10 or 100 removes the need for an external gain-setting resistor and supports repeatable scaling with 0.01% gain accuracy. Its 180 µV offset voltage is small relative to many low-level transducer outputs, while the 30 V/µs slew rate improves response to sensor steps. Place the amplifier close to the bridge and guard the high-impedance input traces to minimize leakage and parasitic pickup.

🖥️

High-Speed Data Acquisition

The LT1102ACH is useful in high-speed data-acquisition front ends that must preserve transient information rather than merely amplify a slow DC signal. Its 30 V/µs slew rate, improved settling behavior, fixed-gain operation, and 3 ppm nonlinearity support faithful acquisition of short events across the selected gain range. The 8-pin TO-5 package also provides a compact through-hole solution for instrumentation systems. Keep supply and reference paths short, and validate input-referred settling and overdrive recovery for the actual acquisition bandwidth before finalizing the analog front end.

📷

Low-Current Photodetection

The LT1102ACH suits low-current photodetection because its less-than-10-pA JFET input bias current creates a small error relative to weak sensor currents. The fixed gain of 10 or 100 can condition a photodiode or phototransistor signal without external gain resistors, while the 180 µV offset specification helps control input-referred error. Place the amplifier near the detector to reduce leakage from cables and connectors, use guarded traces, and confirm photodiode capacitance against the amplifier’s settling requirements. Reverse or bipolar detector protection should be designed separately around the input stage.

🔬

Laboratory Instrumentation

The LT1102ACH supports laboratory measurement systems that combine high source impedance with demanding gain stability. Its JFET input stage draws less than 10 pA, reducing loading of sensors and probes, while 0.01% gain accuracy and 3 ppm nonlinearity improve scale-factor confidence. Fixed gains of 10 and 100 simplify channel configuration and reduce external resistor-count variation. For bench instruments, use guarded PCB inputs, clean connectors, symmetrical differential routing, and local supply bypassing. Confirm the device’s exact supply and temperature limits from the manufacturer datasheet for the intended operating environment.

💊

Medical Sensor Signal Conditioning

The LT1102ACH can condition differential outputs from high-impedance medical sensors when leakage, offset, and gain stability are important. Its less-than-10-pA input bias current minimizes disturbance of weak biopotential or sensor currents, while the 180 µV offset and 0.01% gain accuracy establish a low-error amplification baseline. The 30 V/µs slew rate also supports faster physiological signal waveforms. Medical designs still require application-specific isolation, protection, leakage verification, and regulatory review; none of those safety functions are provided by the amplifier package itself.

🏭

Industrial Process Monitoring

The LT1102ACH is appropriate for industrial process-monitoring channels that must separate small differential signals from substantial common-mode voltage. The precision gain of 10 or 100, 0.01% gain accuracy, and 3 ppm nonlinearity improve measurement repeatability, while JFET inputs accommodate high source impedances without loading the sensor heavily. The 30 V/µs slew rate provides useful response margin when process variables change quickly. Use robust input protection, guarded high-impedance routing, local decoupling, and an enclosure design that limits moisture and contamination, particularly in long-life industrial environments.

Where to buy LT1102ACH online?
The LT1102ACH can be requested through the Request a Quote form on this XAIPART product page. The request should identify the exact LT1102ACH ordering code, its 8-pin TO-5 package, the required quantity, and the target delivery region. Because the device is an older instrumentation-amplifier product, confirm lifecycle status and manufacturing availability when submitting the request rather than assuming that every active catalog listing remains production-qualified.
What is the price of LT1102ACH?
Use the Request a Quote form on this page for the current LT1102ACH price and quantity availability. Pricing for legacy instrumentation amplifiers can vary substantially with quantity, condition, traceability, and market availability. The structured pricing panel should be treated as the live commercial reference, while the historical distributor-memory amount retained on this page is not a current quotation and should not be used for budgeting a new production release.
What is the lead time for LT1102ACH?
Submit an LT1102ACH request through the Request a Quote form to obtain a current lead-time statement. The lead time depends on inventory position, package condition, traceability requirements, and whether an extended or obsolete-part sourcing plan is needed. The manufacturer product page identifies the LT1102 family as a high-speed, precision instrumentation amplifier, while current procurement availability should be confirmed during quotation rather than inferred from the historical catalog listing.
Is LT1102ACH in stock?
Current LT1102ACH stock should be confirmed through the Request a Quote form on this page. The device is an older Analog Devices instrumentation-amplifier offering, and a distributor catalog appearance does not by itself guarantee immediately shippable inventory. Include the required quantity and acceptable date codes in the request so the supplier can distinguish new, factory-sealed, and previously handled material before offering a delivery commitment.
What is the operating voltage of LT1102ACH?
The LT1102ACH operating voltage requires confirmation from the manufacturer datasheet before design sign-off. The device is a fixed-gain, JFET-input instrumentation amplifier in an 8-pin TO-5 package, but the accessible product summary does not state its complete supply-voltage limits. Use the supply-voltage table and absolute-maximum section in the manufacturer datasheet to select rails, protection components, and the required bypass capacitors for the intended laboratory, industrial, or medical equipment.
What are the key specifications of LT1102ACH that engineers should know?
The LT1102ACH is an 8-pin TO-5 instrumentation amplifier with fixed-gain options of 10 or 100, 0.01% gain accuracy, and 3 ppm nonlinearity. According to the manufacturer product information, it also provides less than 10 pA input bias current, a 180 µV offset voltage, no output offset contribution, and a 30 V/µs slew rate. These characteristics favor low-current sensing and precision differential measurement where fast settling and high input impedance are both important.
LT1102ACH vs LT1102AH - which is better for a precision measurement system?
The LT1102ACH and LT1102AH use the same 8-pin TO-5 instrumentation-amplifier family, but their temperature grades must be checked before making a direct substitution. The family provides fixed gains of 10 or 100, 0.01% gain accuracy, 3 ppm nonlinearity, less than 10 pA bias current, and a 180 µV offset voltage. Select LT1102ACH for its specified commercial operating envelope and LT1102AH only after confirming the required temperature range, grade markings, and qualification expectations.
What is the difference between LT1102ACH and other JFET instrumentation amplifiers?
The LT1102ACH distinguishes itself through a combination of fixed gain, low input bias current, precision gain accuracy, and improved dynamic behavior. The manufacturer lists gains of 10 or 100 with 0.01% gain accuracy and 3 ppm nonlinearity, less than 10 pA input bias current, and a 180 µV offset voltage. Its stated improvements in slew rate, settling time, gain-bandwidth product, and overdrive recovery make it suitable when a generic low-noise amplifier is too slow for the measurement loop.
When should I choose LT1102ACH over a general-purpose op amp?
Choose the LT1102ACH when the source is differential, impedance is high, and the measurement requires stable gain without external gain-setting resistors. Its JFET inputs, less than 10 pA bias current, 0.01% gain accuracy, and 3 ppm nonlinearity simplify precision signal conditioning. A general-purpose op amp may be more appropriate for single-ended, low-frequency tasks, but it usually requires more external gain-setting and input-balancing components.
Is LT1102ACH suitable for high-impedance sensor measurement?
The LT1102ACH is suitable for high-impedance sensor measurement because its JFET input bias current is specified below 10 pA. This reduces the current drawn through a sensor or source resistance and limits the resulting error voltage. The 180 µV input offset specification and 0.01% gain accuracy also support precision measurement, although cable leakage, guarding, PCB contamination, and input protection leakage must still be controlled.
What is the best drop-in replacement for LT1102ACH?
The LT1102AH is the closest identified same-family drop-in candidate because it uses the same 8-pin TO-5 format and preserves the LT1102 instrumentation-amplifier architecture. Before replacing the LT1102ACH, verify the exact fixed-gain option, supply limits, temperature grade, pin configuration, offset behavior, and package drawing. No cross-brand equivalent was established with both a verified TO-5 footprint and parametrically comparable electrical ratings, so a redesign-level substitute should not be presented as a drop-in replacement.
What can replace LT1102ACH?
LT1102AH can serve as the direct family candidate for an LT1102ACH replacement because both are associated with the 8-pin TO-5 LT1102 instrumentation-amplifier family. Review the ordering information and datasheet for both devices before committing to the substitution, especially the gain version, temperature range, and electrical limits. If either package or grade differs, the component is not a drop-in replacement and the PCB and signal-chain requirements must be redesigned.
Where to download LT1102ACH datasheet PDF?
The LT1102ACH datasheet is available through the Analog Devices product page linked on this product record and through the indexed LT1102ACH PDF listed in the technical references. Use the manufacturer datasheet as the controlling document for the pin description, supply limits, typical characteristics, package dimensions, and ordering information. The manufacturer identifies the LT1102 as an 8-pin, fixed-gain, high-speed JFET-input instrumentation amplifier with gains of 10 or 100.
Where to find the LT1102ACH pinout?
Find the LT1102ACH pin configuration in the pin-description and package-drawing sections of the manufacturer datasheet. The device is housed in an 8-pin TO-5 metal-can package, but the accessible product summary does not reproduce the numbered terminal names. Assign PCB connections only from the datasheet’s official pin table and observe the metal-can orientation mark, since incorrect numbering around a circular package can reverse input polarity or connect a supply terminal incorrectly.
How should the LT1102ACH be handled for low-leakage measurements?
Handle the LT1102ACH with attention to leakage because its less-than-10-pA JFET input bias current is a central performance advantage. Use guarded input traces, clean surfaces, conformal coating where appropriate, and low-leakage protection components. Keep the differential input paths short and symmetric, avoid excessive exposed board area, and verify that connector contamination or moisture does not create a leakage path comparable with the specified bias current.

Dữ liệu tham khảo kỹ thuật cho LT1102ACH — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose the LT1102ACH when the source is differential, its impedance is high, and the measurement needs a fixed gain of 10 or 100 with low leakage. It is especially attractive for bridge sensors, precision laboratory equipment, photodetection, and process-monitoring channels where 0.01% gain accuracy, 3 ppm nonlinearity, less than 10 pA bias current, and fast slewing are more important than a modern surface-mount footprint. LT1102AH is the closest identified family alternative because it retains the 8-pin TO-5 format, but check its exact temperature grade and ordering information before substitution. No cross-brand part was established as both pin-compatible and parametrically equivalent, so do not treat a generic instrumentation amplifier as a drop-in replacement. For new designs that do not require the original TO-5 footprint, compare modern instrumentation amplifiers on supply range, bandwidth, noise, input bias current, gain accuracy, offset, package, lifecycle status, and protection requirements before changing the architecture.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này LT1102AH
Package TO-5 metal can, 8 pins TO-5 metal can, 8 pins
Brand Analog Devices Analog Devices
Product Type Fixed-gain instrumentation amplifier Fixed-gain instrumentation amplifier
Fixed Gain Options 10 or 100 V/V 10 or 100 V/V
Gain Accuracy 0.01% 0.01%
Nonlinearity 3 ppm 3 ppm
Input Offset Voltage 180 µV 180 µV
Input Bias Current <10 pA <10 pA
Slew Rate 30 V/µs 30 V/µs

Bảo phân biệt quan trọng

  • Fixed-gain accuracy without an external gain-setting resistor (vsLT1102AH)
  • Low-leakage JFET input stage (vsLT1102AH)
  • Precision signal conditioning with fast large-signal response (vsLT1102AH)

Ghi chú thiết kế

Route the two differential inputs symmetrically and place the LT1102ACH close to the source. High-impedance JFET inputs can couple leakage and injected noise even though the specified bias current is below 10 pA. Use grounded guarding around sensitive nodes where PCB area permits, avoid test-point contamination, and keep connector and relay contacts away from the input path. Clean the assembled board and control moisture when operating below the device’s temperature limits.

Decouple each supply connection as close as practical to the relevant LT1102ACH pins, and follow the manufacturer’s recommended capacitor values and ESR characteristics. Confirm the exact operating supply range before applying rails. Because this is a fixed-gain precision instrumentation amplifier, supply noise and ground movement can become input-referred errors even when the signal itself is small. Check power-supply sequencing, return-current paths, and the noise bandwidth relevant to the intended measurement bandwidth.

Validate settling time at the selected fixed gain rather than relying only on the 30 V/µs slew-rate figure. Fast slew rate reduces large-signal transition time, but final accuracy also depends on small-signal settling, overdrive recovery, capacitance, and system layout. Measure both a full-scale step and a small perturbation around the operating level. For sensors with substantial capacitance, minimize lead length and consider guarding or a suitable isolation strategy.

The 8-pin TO-5 metal-can construction provides a robust thermal path, but its performance still depends on how the device is mounted. Keep the can accessible to ambient convection when the amplifier dissipates appreciable power, and avoid placing it beside heat sources that increase its case or ambient temperature. Verify the operating-temperature grade of the exact ordering code and calculate worst-case dissipation from the actual supply, output voltage, and load current before sealing the assembly.

Thông tin tuân thủ

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Không chì
Unknown
Không halogen
Unknown
Khoáng vật xung đột
Unknown

The manufacturer product information identifies an instrumentation amplifier but does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for LT1102ACH. AEC-Q100 is not applicable to this precision analog amplifier.

Tìm kiếm liên quan

LT1102ACH datasheet LT1102ACH datasheet pdf LT1102ACH pinout LT1102ACH TO-5 pinout Analog Devices LT1102ACH LT1102ACH fixed gain 10 100 LT1102ACH 0.01% gain accuracy LT1102ACH input bias current LT1102ACH instrumentation amplifier application LT1102ACH drop-in replacement LT1102ACH vs LT1102AH LT1102ACH price LT1102ACH stock What can replace LT1102ACH?

Các bộ phận và thuật ngữ liên quan

Analog Devices Linear Technology LT1102ACH LT1102AH instrumentation amplifier differential amplifier operational amplifier amplifier IC analog integrated circuit JFET input fixed gain gain accuracy input offset voltage input bias current slew rate nonlinearity overdrive recovery TO-5 metal can 8-pin package through-hole package precision measurement high-impedance sensor data acquisition signal conditioning
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ