Analog Devices

LT1102CJ8 - 10/100 Gain Precision Amplifier | Analog Devices

部品番号: LT1102CJ8 ✗ 生産終了
180 µV Vdss Less than 10 pA Id 8-CDIP (0.300 in, 7.62 mm) Package
MOQ: 1 |

LT1102CJ8 概要

Analog Devices LT1102CJ8 is a precision, high-speed JFET-input instrumentation amplifier with selectable fixed gains of 10 or 100, packaged in an 8-pin ceramic DIP. It is designed for signal-conditioning applications requiring low input bias current, accurate fixed gain, rapid slew rate, and a high gain-bandwidth product.

An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals superimposed on larger common-mode voltages. Its internal topology amplifies the difference between two inputs while rejecting shared voltage and noise. The LT1102 belongs to the instrumentation-amplifier hierarchy within the broader amplifier and analog signal-processing categories, and its JFET input stage is suited to high-impedance sources.

The device provides gain accuracy of 0.01% and non-linearity of 3 ppm, eliminating the need for an external gain-setting resistor. According to the Analog Devices LT1102 product information, input bias and offset currents are below 10 pA, while offset voltage is approximately 180 µV. A gain-bandwidth product of 3.5 MHz and slew rate of 30 V/µs support accurate response to rapidly changing input signals.

The fixed-gain architecture simplifies instrumentation front ends by moving gain selection inside the package. It is particularly useful when a system needs repeatable gain accuracy with minimal external components. Users should still account for input and output bandwidth, common-mode range, output swing, and noise when designing a complete analog signal chain.

Typical uses include high-impedance sensor interfaces, bridge-amplifier signal conditioning, biomedical instrumentation, laboratory measurement systems, and industrial acquisition electronics. The JFET inputs are particularly relevant when source leakage or bias-current error would otherwise compromise a precision measurement.

Layout should keep sensitive input traces short, provide a stable reference return, and place input compensation or filtering components close to the device. Where the source impedance is high, parasitic capacitance and leakage can create settling errors even when the amplifier itself has a fast slew rate.

This page combines the manufacturer specifications, package information, comparison points, and engineering-oriented selection guidance. It also distinguishes confirmed alternatives from unverified cross-reference listings so engineers can assess replacement risk before modifying a PCB.

ドロップイン代替品: LT1102CJ8 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

LT1102ACN8#PBF

✅ ドロップイン
📦 8-pin ceramic DIP
Related fixed-gain LT1102 family member with a different ordering suffix; exact gain, pinout, and temperature-grade differences require confirmation

📋 参考代替品(カタログ未掲載)

LT1102CN8

✅ ドロップイン
📦 8-pin ceramic DIP
Related fixed-gain LT1102 family member with a different package suffix; exact gain and ordering-temperature differences require confirmation

📋 参考代替品(カタログ未掲載)

LT1102CJ8 最大定格&電気的特性

Product Type Instrumentation amplifier
Number of Circuits 1 circuit
Input Stage JFET input
Available Fixed Gains 10 or 100
Gain Accuracy 0.01%
Non-Linearity 3 ppm
Maximum Input Bias Current Less than 10 pA
Maximum Input Offset Current Less than 10 pA
Offset Voltage 180 µV
Gain-Bandwidth Product 3.5 MHz
Slew Rate 30 V/µs
パッケージ 8-CDIP (0.300 in, 7.62 mm)
Terminal Count 8 terminals
実装タイプ Through-hole
Temperature Grade Commercial

LT1102CJ8 8-cdip (0.300 in, 7.62 mm) ピン配置ガイド

LT1102CJ8 (8-cdip (0.300 in, 7.62 mm) パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

LT1102CJ8 の 8-cdip (0.300 in, 7.62 mm) パッケージピン配置図

詳細なピン配置データはありません: LT1102CJ8.

詳細は データシート をご参照ください。

主な用途

LT1102CJ8 の用途: 6 件s: High-Impedance Sensor Signal Conditioning, Strain Gauge and Bridge Measurement, Biomedical and Electrochemical Measurement, Laboratory Data Acquisition, Industrial Process Monitoring, Precision Waveform and Transient Capture.

🧩

High-Impedance Sensor Signal Conditioning

The LT1102CJ8 is suitable for conditioning weak differential sensor outputs while limiting bias-current error. Its JFET input stage provides bias and offset currents below 10 pA, while the internal fixed gain of 10 or 100 avoids an external gain-setting resistor. The 0.01% gain accuracy and 3 ppm non-linearity help preserve the integrity of measurements from high-impedance probes, chemical sensors, and precision resistive bridges. The 3.5 MHz gain-bandwidth product also supports acquisition bandwidth beyond static voltmeter use, although source capacitance and sensor settling time must be included in the overall system response.

🏭

Strain Gauge and Bridge Measurement

The LT1102CJ8 can amplify the small differential voltage generated by a resistive strain-gauge bridge while rejecting the larger common-mode excitation voltage. Its sub-10-pA input currents reduce errors when long leads or high-impedance bridge nodes increase sensitivity to leakage. Fixed internal gain provides repeatable 10 or 100 multiplication with 0.01% gain accuracy, avoiding resistor-calibration uncertainty associated with many external gain networks. For practical bridge designs, place the amplifier close to the bridge, maintain symmetric input routing, and confirm that the selected gain remains stable within the device's operating limits and output-swing constraints.

💊

Biomedical and Electrochemical Measurement

The LT1102CJ8 is appropriate for low-level biomedical and electrochemical signals where source leakage can create measurement errors comparable to the signal itself. JFET inputs with bias and offset currents below 10 pA help preserve the integrity of high-impedance electrode measurements, while 180 µV offset voltage establishes the basic input-referred accuracy. The 30 V/µs slew rate and 3.5 MHz gain-bandwidth product support faster waveforms than a purely precision DC amplifier. Designers should still account for electrode polarization, patient protection requirements, guarding, leakage paths, and the instrumentation amplifier's common-mode and output-voltage limits.

🖥️

Laboratory Data Acquisition

The LT1102CJ8 supports laboratory measurement front ends that need both accurate gain and useful signal bandwidth. Its internal gains of 10 or 100, 0.01% gain accuracy, and 3 ppm non-linearity provide repeatable scaling without an external gain resistor. A 3.5 MHz gain-bandwidth product and 30 V/µs slew rate allow the amplifier to process rapidly changing signals, subject to the selected gain and output limits. The device is particularly useful for buffering moderate-impedance transducers, diagnostic probes, and compact instrumentation systems. Keep input filtering outside the fast-signal path unless noise control is required, and use a low-noise reference supply to preserve the available measurement fidelity.

🏭

Industrial Process Monitoring

The LT1102CJ8 can condition low-level process signals when sensor leads, grounding, and common-mode voltage make simple differential input stages inadequate. Its instrumentation-amplifier architecture rejects shared voltage, while JFET input currents below 10 pA limit errors caused by leakage into high-impedance transducers. Fixed gain and 0.01% accuracy simplify calibration, and the 30 V/µs slew rate provides headroom for transient process events. In an industrial implementation, keep sensitive traces away from switching nodes and power converters, provide a clean return path, and confirm that the 8-CDIP package has adequate spacing for voltage isolation and service requirements.

📺

Precision Waveform and Transient Capture

The LT1102CJ8 is useful when a measurement chain needs more bandwidth than ordinary precision DC instrumentation amplifiers provide. Its 3.5 MHz gain-bandwidth product supports wider-band signal capture, while the 30 V/µs slew rate reduces large-signal rise-time distortion. The fixed internal gain of 10 or 100 allows designers to avoid external gain-setting resistors and retain 0.01% gain accuracy with 3 ppm non-linearity. Input bias currents below 10 pA benefit high-impedance sources. Care is required when the selected gain closes the usable bandwidth, and the output must remain inside its voltage swing range during transient peaks.

おすすめ製品の概要

LT1102CJ8 Analog Devices 使用用途: High-Impedance Sensor Signal Conditioning, Strain Gauge and Bridge Measurement, Biomedical and Electrochemical Measurement, Laboratory Data Acquisition, Industrial Process Monitoring, Precision Waveform and Transient Capture LT1102CN8 Related LT1102 family option 使用用途: High-Impedance Sensor Signal Conditioning, Biomedical and Electrochemical Measurement, Industrial Process Monitoring LT1102ACN8#PBF Related fixed-gain LT1102 family member 使用用途: Strain Gauge and Bridge Measurement, Laboratory Data Acquisition, Precision Waveform and Transient Capture
What is the LT1102CJ8 instrumentation amplifier used for?
The LT1102CJ8 is a precision JFET-input instrumentation amplifier used to amplify small differential signals while rejecting common-mode voltage. It offers fixed gains of 10 or 100, 0.01% gain accuracy, and 3 ppm non-linearity. According to the Analog Devices LT1102 product information, its combination of low input bias current and accurate internal gain is intended for high-impedance sensor and measurement front ends.
What is the gain of LT1102CJ8?
The LT1102 family provides fixed gains of 10 or 100, so no external gain-setting resistor is required. The verified LT1102 product information identifies a gain accuracy of 0.01% and non-linearity of 3 ppm. The exact gain selected by the CJ8 ordering configuration should be confirmed in the manufacturer pinout and ordering information before a replacement is approved.
What are the key specifications of LT1102CJ8 that engineers should know?
The LT1102CJ8 combines fixed gains of 10 or 100, 0.01% gain accuracy, 3 ppm non-linearity, input bias and offset currents below 10 pA, approximately 180 µV offset voltage, a 3.5 MHz gain-bandwidth product, and a 30 V/µs slew rate. According to the Analog Devices LT1102 product page, these characteristics make it appropriate for precision, high-speed signal conditioning.
Where can I download the LT1102CJ8 datasheet PDF?
The official LT1102 datasheet and product information are available from the Analog Devices LT1102 product page at analog.com. Use the manufacturer datasheet to confirm gain selection, pin assignments, supply limits, common-mode range, and package details before layout or replacement work. The LT1102CJ8 is an 8-CDIP, 0.300-inch, 7.62 mm through-hole package.
Where can I find the LT1102CJ8 pinout?
Use the pin-description table in the Analog Devices LT1102 manufacturer datasheet for the authoritative LT1102CJ8 pinout. The verified product information identifies the device as an 8-CDIP with eight terminals, but it does not expose the individual pin names. Do not infer connections from an 8-pin package drawing alone because input, output, supply, and gain-select pins must be matched exactly.
Can LT1102ACN8#PBF replace LT1102CJ8?
LT1102ACN8#PBF can be considered only after confirming that its fixed gain, pinout, temperature grade, and package construction match the required LT1102CJ8 configuration. The manufacturer information identifies both parts as members of the LT1102 fixed-gain family, but the available comparison confirms family membership rather than complete pin-for-pin interchangeability. Verify the ordering table and datasheet before substitution.
What can replace the LT1102CJ8?
The best replacement must match the 8-CDIP footprint, pin assignments, fixed-gain option, supply range, input and output limits, and temperature grade. LT1102ACN8#PBF and LT1102CN8 are identified as related LT1102 family parts, but the available comparison does not establish every electrical and pin-compatibility detail. A drop-in decision therefore requires checking the manufacturer datasheets.
LT1102CJ8 vs LT1102ACN8#PBF: which is better for precision sensing?
Choose LT1102CJ8 when its documented ceramic-DIP construction and ordering code meet the required environmental and temperature conditions; consider LT1102ACN8#PBF when its gain configuration, package, and qualification match the design. Both belong to the LT1102 precision instrumentation-amplifier family, but the verified material does not provide a complete side-by-side comparison of every operating limit.
When should I choose LT1102CJ8 over another LT1102 variant?
Choose LT1102CJ8 when the design specifically requires an 8-CDIP package, the fixed gain associated with the CJ8 ordering code, and the commercial temperature grade shown in the verified listing. Select another family member only after confirming that its gain, package construction, pinout, and temperature range satisfy the application. The internal fixed-gain architecture simplifies boards needing repeatable accuracy.
Is LT1102CJ8 suitable for high-impedance sensor interfaces?
The LT1102CJ8 is suitable for high-impedance sensor interfaces because its JFET input stage has bias and offset currents below 10 pA, while its gain accuracy is 0.01%. The manufacturer lists a 3.5 MHz gain-bandwidth product and 30 V/µs slew rate, supporting precision acquisition from sources such as strain gauges, pH electrodes, and laboratory probes.
Where can I buy LT1102CJ8 online and what is its lead time?
Use the Request a Quote form on this page to ask about LT1102CJ8 availability, current lead time, minimum order quantity, and shipment options. The verified listing confirms an 8-CDIP instrumentation amplifier from Analog Devices, but it does not print a usable quantity-break price table or a guaranteed inventory quantity. The quote form is the appropriate channel for current commercial terms.
What is the price of LT1102CJ8?
Current LT1102CJ8 commercial terms are handled through the Request a Quote form on this page. The available product listings confirm the exact MPN, manufacturer, package, and instrumentation-amplifier classification but do not show qualifying quantity-break prices. Submit the required quantity and target package information with the quote request to receive current sourcing terms.
Is LT1102CJ8 in stock?
Stock status should be confirmed through the Request a Quote form on this page because inventory changes by quantity, package code, and distribution channel. The verified distributor listing states that LT1102CJ8 is an Analog Devices 8-CDIP instrumentation amplifier, while another listing mentions availability, but neither provides a durable inventory guarantee. Use the form for a current supply confirmation.
How should the LT1102CJ8 be used in a bridge-amplifier circuit?
Connect the bridge differential output to the instrumentation amplifier's differential inputs and use the internal fixed gain rather than adding an external gain resistor. The LT1102's 0.01% gain accuracy, 3 ppm non-linearity, and sub-10-pA input currents reduce errors in high-impedance bridges. Input filtering and grounding should be designed around the source impedance and required settling behavior.
Is LT1102CJ8 RoHS compliant and AEC-Q100 qualified?
The RoHS, REACH, and AEC-Q100 status of LT1102CJ8 has not been confirmed in the available manufacturer page text, so those compliance claims should be treated as unknown. The verified listing identifies a commercial-grade 8-CDIP instrumentation amplifier. Request current compliance documentation from Analog Devices or an authorized channel for the exact ordering code before qualifying a regulated product.

エンジニアリング参考データ: LT1102CJ8 — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the LT1102CJ8 when the design requires a precision JFET-input instrumentation amplifier with fixed gain, low input leakage, and a compact 8-pin ceramic-DIP implementation. Its 0.01% gain accuracy, 3 ppm non-linearity, sub-10-pA bias current, and 30 V/µs slew rate make it well suited to high-impedance sensors, bridge circuits, laboratory probes, and electrochemical measurements. LT1102ACN8#PBF or LT1102CN8 should be considered only after their ordering codes are matched to the required gain, temperature grade, pinout, and package construction. The JT8 ordering code is not a universal substitute because different suffixes can alter device construction or grade. For new precision designs, use the internal fixed gain to reduce component count, but verify output swing, common-mode range, supply limits, and actual closed-loop bandwidth before committing the circuit.

代替品との比較

パラメータ この製品 LT1102ACN8#PBF LT1102CN8
Package 8-CDIP (0.300 in, 7.62 mm) 8-pin ceramic DIP 8-pin ceramic DIP
Brand Analog Devices Analog Devices Analog Devices
Product Type Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier
Fixed Gain Options 10 or 100 10 or 100; exact ordering-code gain requires confirmation 10 or 100; exact ordering-code gain requires confirmation
Gain Accuracy 0.01% 0.01% for the LT1102 family 0.01% for the LT1102 family
Non-Linearity 3 ppm 3 ppm for the LT1102 family 3 ppm for the LT1102 family
Gain-Bandwidth Product 3.5 MHz 3.5 MHz for the LT1102 family 3.5 MHz for the LT1102 family
Slew Rate 30 V/µs 30 V/µs for the LT1102 family 30 V/µs for the LT1102 family

主な差別化要因

  • Accurate gain implemented internally (vs LT1102CN8)
  • Very low input leakage for precision sources (vs LT1102ACN8#PBF)
  • Fast large-signal response (vs LT1102CN8)
  • Compact instrumentation function in eight pins (vs LT1102ACN8#PBF)

設計ノート

Route the two differential inputs as a closely matched pair and keep them short, away from switching nodes and high-current return paths. Instrumentation-amplifier input bias-current error depends on source impedance, so unequal lead lengths, leakage through PCB contamination, and nearby power circuitry can degrade accuracy. Place any input filtering capacitors close to the relevant input pins, and use a continuous ground reference beneath the analog signal path.

Do not assume that every LT1102 ordering suffix is interchangeable without checking the selected fixed gain and pinout. The CJ8, CN8, and ACN8#PBF identifiers refer to related 8-pin family variants, but package construction, gain selection, and ordering temperature grade can differ. Verify the gain configuration and all eight connections in the manufacturer pin-description table before substituting a part on an existing PCB.

Account for the gain-dependent bandwidth and the 30 V/µs slew rate when defining the expected measurement bandwidth. A 3.5 MHz gain-bandwidth product does not imply the same closed-loop bandwidth at every internal gain setting. Also check output swing against transient peaks. Source capacitance, probe capacitance, and long input wiring can introduce settling behavior that is separate from the amplifier's specified gain-bandwidth product.

Use a clean, low-noise supply and confirm the LT1102CJ8's operating and absolute-maximum voltage limits in the manufacturer datasheet. Decoupling capacitors should be placed near the device's supply pins, with short return paths and an appropriate ground plane. Because the available product information does not state the supply range or quiescent current, these values must not be inferred when designing the power tree.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The verified product information identifies a commercial-grade instrumentation amplifier but does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable to the identified commercial-grade LT1102CJ8 ordering configuration.

データ検証日: 2026-11-14 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

LT1102CJ8 datasheet LT1102CJ8 pinout LT1102CJ8 datasheet pdf LT1102CJ8 specifications LT1102CJ8 8-CDIP Analog Devices LT1102CJ8 LT1102CJ8 instrumentation amplifier LT1102CJ8 high impedance sensor LT1102CJ8 equivalent LT1102CJ8 replacement LT1102CJ8 vs LT1102ACN8#PBF LT1102CJ8 vs LT1102CN8 LT1102CJ8 price LT1102CJ8 stock LT1102CJ8 application circuit

関連部品&用語

Analog Devices Linear Technology LT1102CJ8 LT1102 LT1102ACN8#PBF LT1102CN8 instrumentation amplifier differential-input amplifier amplifier IC analog signal conditioning JFET input fixed gain gain accuracy gain-bandwidth product slew rate input bias current input offset voltage common-mode rejection 8-CDIP ceramic dual in-line package through-hole package high-impedance sensor interface strain gauge bridge electrochemical measurement laboratory data acquisition
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示