An RS-232 transceiver is a line driver and receiver IC that converts logic-level serial signals (TTL/CMOS, 0V to 5V) to the higher voltage EIA/TIA-232E levels (+/-5V or greater) required by serial communication ports, and converts incoming RS-232 levels back to logic levels. It sits within the interface IC family of the broader semiconductor taxonomy, bridging a microcontroller UART and a physical DB-9 serial port without needing +/-12V supplies.
Key features include single +5V operation, which eliminates the dual supply rails older RS-232 interfaces required; dual charge-pump voltage converters that generate the RS-232 signaling levels from the 5V rail using only small 0.1uF flying and storage capacitors; and the E-suffix enhanced ESD protection family design intended for harsh industrial environments. The MAX202E family also uses a proprietary low-dropout transmitter output stage that maintains required +/-5V minimum EIA/TIA-232E output levels even at full load.
According to Analog Devices, the drivers and receivers meet all EIA/TIA-232E and CCITT V.28 specifications at data rates up to 120kbps when loaded, and the drivers sustain +/-5V output swings at data rates in excess of 120kbps under the specified EIA/TIA-232E loading. The MAX202E/MAX232E devices are offered in 16-pin TSSOP, narrow SO, wide SO, and DIP packages, giving designers footprint flexibility across a common pinout.
Typical applications include legacy industrial serial links (PLC and instrumentation ports), point-of-sale terminals and printers, set-top box and modem debug UARTs, and any embedded system that must interoperate with a standard RS-232 COM port. The dual-driver, dual-receiver configuration covers the TX/RX plus RTS/CTS handshake lines of a full serial port.
Design consideration: place the four 0.1uF charge-pump capacitors and the V+ / V- storage capacitors close to the IC pins; ceramic X7R capacitors are recommended, and excessive ESR on C1/C2 degrades charge-pump efficiency and output swing.
This page adds value beyond the manufacturer datasheet by consolidating drop-in alternative cross-references, ESD-grade family comparisons, practical layout guidance, and sourcing information in one place.
ドロップイン代替品: MAX202EUE+ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MAX202EUE+ (同一形状・フットプリント) — 相違点: Package, Supply Voltage.
MAX202EEUE+
✅ ドロップイン価格はお問い合わせください
データシートを見る →MAX232EUE+
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MAX202ECUE+
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX202EUE+ 仕様
| 機能 | RS-232 Transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| 電源電圧 | +5 V single supply |
| データレート | Up to 120 kbps (loaded, EIA/TIA-232E) |
| External Capacitors | 4 x 0.1 uF |
| Signaling Standard | EIA/TIA-232E, CCITT V.28 |
| パッケージ | 16-TSSOP |
| 実装タイプ | Surface Mount |
| Logic Compatibility | TTL / CMOS |
| Receiver Output Type | RS-232 to TTL/CMOS logic level |
| Product Series | MAX202E (harsh environment RS-232 family) |
MAX202EUE+ ピン構成
| ピン 1 | C1+ — Charge-pump capacitor C1 positive terminal |
| ピン 2 | V+ — Positive charge-pump output (externally stored by 0.1uF capacitor) |
| ピン 3 | C1- — Charge-pump capacitor C1 negative terminal |
| ピン 4 | C2+ — Charge-pump capacitor C2 positive terminal |
| ピン 5 | C2- — Charge-pump capacitor C2 negative terminal |
| ピン 6 | V- — Negative charge-pump output (externally stored by 0.1uF capacitor) |
| ピン 7 | T2OUT — RS-232 transmitter 2 output |
| ピン 8 | R2IN — RS-232 receiver 2 input |
| ピン 9 | R2OUT — TTL/CMOS receiver 2 output |
| ピン 10 | T2IN — TTL/CMOS transmitter 2 input |
| ピン 11 | T1IN — TTL/CMOS transmitter 1 input |
| ピン 12 | R1OUT — TTL/CMOS receiver 1 output |
| ピン 13 | R1IN — RS-232 receiver 1 input |
| ピン 14 | T1OUT — RS-232 transmitter 1 output |
| ピン 15 | GND — Ground |
| ピン 16 | VCC — +5V supply voltage |
主な用途
MAX202EUE+ の用途: 6 件s: Industrial PLC and Instrumentation Serial Ports, Point-of-Sale Terminals and Receipt Printers, Embedded Debug and Console UART Interfaces, Medical and Laboratory Instrumentation, Security and Access Control Panels, Legacy Modem and Telecom Equipment Maintenance.
Industrial PLC and Instrumentation Serial Ports
Factory equipment such as PLC programming ports, variable-frequency drive consoles, and bench instruments still expose RS-232 COM interfaces for configuration and diagnostics. The MAX202EUE+ fits because its E-series design targets harsh environments: the enhanced ESD protection on transmitter and receiver inputs withstands the cable-handling transients typical of industrial wiring, while 120kbps EIA/TIA-232E compliance exceeds the 9600-115200 baud rates these ports use. The 2-driver/2-receiver configuration covers TX/RX plus one handshake pair, and single +5V operation reuses the existing logic supply. Its 0.1uF charge-pump capacitors keep the BOM small; only ceramic capacitor placement discipline near pins 1-6 is needed for full +/-5V swing under cable load.
おすすめ
Point-of-Sale Terminals and Receipt Printers
POS terminals, receipt printers, barcode scales and card readers frequently retain RS-232 serial interfaces for host connectivity and peripheral daisy-chaining. The MAX202EUE+ suits these designs with its guaranteed +/-5V minimum EIA/TIA-232E output levels under the full EIA/TIA-232E loading that long printer cables present, and 120kbps loaded data rate comfortably covering typical POS traffic. The E-series enhanced ESD protection copes with frequent operator cable insertion. Single 5V supply matches the logic rail of embedded POS controllers, and the TSSOP-16 footprint conserves board area in compact terminal housings. The charge-pump topology adds no switching-frequency interference above ~hundreds of kHz, trivially filtered by the 0.1uF storage capacitors.
おすすめ
Embedded Debug and Console UART Interfaces
Development boards, network appliances, set-top boxes and industrial gatekeepers commonly reserve an RS-232 console port for firmware recovery and field diagnostics. The MAX202EUE+ converts the MCU UART (TTL/CMOS) to true RS-232 levels so standard null-modem cables and terminal servers connect directly, with receivers restoring RS-232 levels to clean CMOS logic. 120kbps data rate covers typical console baud rates of 115200 baud. The E-series enhanced ESD protection tolerates repeated technician cable insertion during servicing. Only four 0.1uF capacitors are added to the BOM, and the TSSOP-16 package fits dense board layouts. Enable-free operation simplifies power sequencing - the part is live whenever 5V is present.
おすすめ
Medical and Laboratory Instrumentation
Bench instruments - patient monitors, infusion pumps, laboratory analyzers - use RS-232 for data export to host systems per long-standing interoperability conventions. The MAX202EUE+ provides specification-compliant EIA/TIA-232E and V.28 signaling at up to 120kbps, ensuring interoperability with legacy hospital information systems. Its E-series harsh-environment protection benefits medical carts and bedside equipment where cables are frequently connected and disconnected. Single-supply 5V operation integrates with the instrument's logic power tree, and the 0.1uF capacitor requirement keeps isolation-adjacent circuitry simple. The TSSOP-16 surface-mount package supports compact, reflow-assembled boards typical of medical device manufacturing.
おすすめ
Security and Access Control Panels
Alarm panels, door controllers and CCTV matrix switches often expose RS-232 ports for programming tools and integration with legacy building-management systems. The MAX202EUE+ drives these links with guaranteed +/-5V EIA/TIA-232E levels under loaded conditions, and its 120kbps data rate exceeds panel communication speeds. E-series enhanced ESD protection addresses the exposure of field-wired panels to static discharge through long unshielded runs. The 2/2 configuration supports both the primary data channel and a handshake or auxiliary channel for door-hostage supervision. Single 5V supply, four 0.1uF capacitors, and the compact TSSOP-16 package keep panel board area and cost minimal.
おすすめ
Legacy Modem and Telecom Equipment Maintenance
Installed-base modems, channel banks and telecom test sets still in service rely on RS-232 management ports; repair and refurbishment depots need a reliable 5V transceiver to keep these units alive. The MAX202EUE+ is a faithful replacement because it meets the same EIA/TIA-232E and CCITT V.28 specifications the original MAX200-MAX209 generation was designed to, at 120kbps loaded. The E-series harsh-environment rating and enhanced ESD protection exceed the older non-E parts, improving service life. Drop-in TSSOP-16/SOIC/DIP package options across the family ease board-level retrofit. Only four 0.1uF capacitors are needed, matching legacy charge-pump layouts without redesign.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MAX202EUE+ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MAX202EEUE+ | MAX232EUE+ | MAX202ECUE+ |
|---|---|---|---|---|
| Package | 16-TSSOP | 16-TSSOP - same | 16-TSSOP - same | 16-TSSOP - same |
| Brand | Analog Devices (Maxim Integrated) | Analog Devices | Analog Devices | Analog Devices |
| Drivers / Receivers | 2 / 2 | 2 / 2 | 2 / 2 | 2 / 2 |
| Supply Voltage | +5 V single supply | +5 V single supply | +5 V single supply | +5 V single supply |
| Data Rate | 120 kbps (loaded) | 120 kbps (loaded) | 120 kbps (loaded) | 120 kbps (loaded) |
| External Capacitors | 4 x 0.1 uF | 4 x 0.1 uF | 4 x 0.1 uF | 4 x 0.1 uF |
| ESD Protection Grade | E-series enhanced ESD (harsh environment) | 15kV ESD-protected (highest in family) | E-series standard | E-series enhanced (commercial temp grade) |
| Signaling Compliance | EIA/TIA-232E, CCITT V.28 | EIA/TIA-232E, CCITT V.28 | EIA/TIA-232E, CCITT V.28 | EIA/TIA-232E, CCITT V.28 |
主な差別化要因
- Harsh-environment E-series ESD robustness (vs MAX232EUE+)
- Lower cost with same footprint available (vs MAX202EEUE+)
- Only 0.1uF external capacitors required (vs legacy MAX202 (non-plus, original generation))
設計ノート
Place the four 0.1uF charge-pump and storage capacitors within 5-10 mm of pins 1 through 6, with short, wide traces. Use X7R or X5R multilayer ceramics rated 16V or higher; avoid Y5V dielectrics whose capacitance collapses under DC bias, and avoid tantalum or electrolytic parts whose ESR reduces charge-pump efficiency. Poor capacitor placement is the most common cause of drivers failing to reach the +/-5V EIA/TIA-232E minimum swing under full 3k-ohm/2500pF test load.
Do not route the R1IN/R2IN RS-232 receiver inputs through series resistors or protection networks that add more than a few hundred ohms - receiver input thresholds are referenced to the RS-232 levels and additional series impedance with cable capacitance slows edges. Also confirm connector polarity: RS-232 levels are inverted relative to TTL, so a TX/RX swap produces silence rather than garbage; a loopback test at the connector is the fastest sanity check during bring-up.
The internal charge pumps switch at roughly tens to hundreds of kilohertz and can couple ripple into adjacent sensitive analog circuitry through the V+ and V- pins. Keep the V+/V- storage capacitor loops small and do not run the charge-pump traces near precision analog signals or antenna feeds. If a nearby sensitive rail shows charge-pump ripple, add 1k-ohm/1uF decoupling on the affected rail rather than enlarging the pump capacitors, which slows output slew and limits data rate.
コンプライアンス情報