MAX3070EASD+T - 3.3V RS-485/422 Transceiver | Maxim
部品番号: MAX3070EASD+T ✓ 生産中MAX3070EASD+T 概要
An RS-485/RS-422 transceiver is an interface IC that converts between logic-level signals and balanced differential bus signals. RS-485 supports multipoint, half-duplex communication over longer industrial distances, while RS-422 commonly supports point-to-point, full-duplex links. The MAX3070EASD+T family combines one transmit driver and one receive channel, allowing a compact interface for systems that need both directions of differential data transfer.
The MAX3070EASD+T operates from a 3.3 V supply and provides ±15 kV ESD-protected bus pins. Its fail-safe receiver circuitry guarantees a logic-high output when the receiver inputs are open or shorted. This behavior helps a system interpret an inactive, faulted, or unconnected bus deterministically. The hot-swap feature supports connection of the transceiver to an active bus without the normal startup disturbance associated with an unpowered driver.
Internally, the device integrates an RS-485/422-compatible line driver, differential receiver, fail-safe receiver logic, and hot-swap protection into a single 14-pin surface-mount package. The manufacturer describes the MAX3070E through MAX3079E family as 3.3 V, ±15 kV ESD-protected transceivers. A digital transceiver is distinct from an RF transceiver: its principal function is robust conversion of digital logic levels to and from balanced wired-interface signals.
Typical uses include industrial sensor networks, factory automation equipment, building-control systems, data acquisition units, and communication links between distributed controllers and field devices. The fail-safe receiver is particularly useful where cables can be disconnected or where a system must maintain a predictable state during reconnection. The ±15 kV protection rating is particularly relevant to industrial environments in which exposed cabling and maintenance practices increase ESD risk.
For implementation, place the transceiver close to the connector or board edge so that the protected bus traces are short, and route the balanced differential pair as a tightly coupled pair. Decoupling capacitors should be positioned close to the supply and ground pins. External termination, biasing, and protection components must be selected from the actual cable length, topology, and grounding arrangement rather than added indiscriminately.
This product page combines the manufacturer's electrical and protection details with package information, application guidance, drop-in alternatives, and practical bus-layout considerations. Use the MAX3070E-MAX3079E datasheet for the authoritative pin descriptions, absolute maximum ratings, timing characteristics, and recommended external circuitry before completing a production design.
ドロップイン代替品: MAX3070EASD+T — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MAX3070EASD+T (同一形状・フットプリント) — 相違点: Package, Product Type.
MAX3071EASD
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX3072EASD
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX3073EASD
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
SP3070EEN-L/TR
✅ ドロップイン📋 参考代替品(カタログ未掲載)
ISL83070EIBZA-T
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MAX3070EASD+T 仕様
| Product Type | RS-485/RS-422 interface transceiver |
| 電源電圧 | 3.3 V |
| Driver Count | 1 driver |
| Receiver Count | 1 receiver |
| Supported Interfaces | RS-485 and RS-422 |
| ESD Protection | ±15 kV |
| Fail-Safe Receiver | Yes |
| Fail-Safe Open-Input Output | Logic-high |
| Fail-Safe Shorted-Input Output | Logic-high |
| Hot-Swap Support | Yes |
| パッケージ | 14-pin SOIC |
| 実装タイプ | Surface mount |
MAX3070EASD+T 14-pin soic ピン配置ガイド
MAX3070EASD+T (14-pin soic パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: MAX3070EASD+T.
詳細は データシート をご参照ください。
主な用途
MAX3070EASD+T の用途: 6 件s: Industrial Sensor Networks, Factory Automation Controllers, Building Control Systems, Data Acquisition Equipment, Instrumentation Interfaces, Remote Monitoring Terminals.
Industrial Sensor Networks
The MAX3070EASD+T fits industrial sensor-network links that require a balanced RS-485 bus and protection during installation. Its 3.3 V operation suits low-voltage embedded controllers, while ±15 kV ESD protection adds a useful barrier on field-accessible cabling. The fail-safe receiver provides a defined logic-high state when a remote sensor is disconnected or its wiring is shorted. Place the transceiver near the field connector, route the bus as a differential pair, and use the manufacturer data sheet to determine termination, biasing, and grounding requirements for the installed cable length.
おすすめ
Factory Automation Controllers
The MAX3070EASD+T is suitable for connecting factory automation controllers to remote actuators, modules, and operator panels over a shared differential bus. One driver and one receiver support the communication direction required by a half-duplex RS-485 node, while the 3.3 V supply simplifies integration with modern embedded logic. Its hot-swap feature is useful when equipment may be attached to an active network during maintenance. Confirm node direction, baud rate, termination, and bus biasing in firmware and with the MAX3070E-MAX3079E manufacturer data sheet before deployment.
おすすめ
Building Control Systems
The MAX3070EASD+T can bridge low-voltage building-control electronics to RS-485 devices such as distributed sensors, HVAC controllers, or lighting interfaces. The balanced interface is appropriate for building wiring that may connect equipment from different rooms or service areas. ±15 kV ESD protection helps address electrostatic discharge encountered during installation and servicing, while fail-safe logic avoids uncertain receiver states when a peripheral is unplugged. Locate the transceiver near the external connector, keep the differential route short and balanced, and verify grounding arrangements with the complete system design.
おすすめ
Data Acquisition Equipment
The MAX3070EASD+T is appropriate for data-acquisition units that distribute commands and collect measurements across several remote channels. Its 3.3 V operation permits direct integration with compact embedded systems, and the one-driver, one-receiver arrangement supports a controlled bidirectional RS-485 node. Fail-safe receiver behavior gives the host processor a predictable state when a sensor cable is open or shorted. Use a controlled bus master, define node addresses in firmware, and confirm termination and fail-safe bias values against the cable topology to prevent reflections and undefined bus levels.
おすすめ
Instrumentation Interfaces
The MAX3070EASD+T can provide the physical bus layer for laboratory and test instruments that exchange commands or measurement results over RS-485. Its ±15 kV ESD protection is valuable when users connect external leads, and the fail-safe receiver supports stable interpretation of an inactive connected device. The hot-swap characteristic also improves serviceability when a portable instrument joins an operating bus. Keep the analog and digital grounding strategy controlled, place protection and termination components according to the manufacturer's application guidance, and avoid routing the protected bus traces through high-impedance leakage-prone areas.
おすすめ
Remote Monitoring Terminals
The MAX3070EASD+T supports compact remote monitoring terminals that exchange status and control data over a wired differential network. A 3.3 V transceiver is useful in battery- or energy-conscious installations where the communications device operates alongside low-voltage sensors. The fail-safe feature improves behavior after power restoration or cable reconnection, while hot-swap capability reduces disruption when nodes join an active bus. Configure the node to remain undriven when not selected, use deterministic address and retry logic, and validate the complete bus with realistic cable lengths and termination.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MAX3070EASD+T — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MAX3071EASD | MAX3072EASD | MAX3073EASD | SP3070EEN-L/TR | ISL83070EIBZA-T |
|---|---|---|---|---|---|---|
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Suntek Technology | Renesas Electronics |
| Package | 14-pin SOIC | 14-pin SOIC | 14-pin SOIC | 14-pin SOIC | 14-pin SOIC | 14-pin SOIC |
| Supported Interfaces | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 | RS-485 |
主な差別化要因
- Single-transceiver integration with protected differential I/O (vs SP3070EEN-L/TR)
- Defined receiver state under open and shorted inputs (vs ISL83070EIBZA-T)
- Lower receiver-channel count supports a simpler point-to-point interface (vs MAX3071EASD)
- Same-family option preserves the established MAX3070E feature set (vs MAX3072EASD)
設計ノート
Place the MAX3070EASD+T near the external communication connector and route the RS-485/RS-422 pair as a tightly coupled differential pair. Keep the bus traces away from switching nodes, high-current paths, and antenna-like structures. Connect the transceiver ground reference according to the complete interface design, and verify the conductor-to-ground arrangement with the manufacturer data sheet because incorrect shield or ground termination can increase surge currents.
Do not assume that identical package dimensions guarantee a functional drop-in replacement. Check pin names, driver-enable behavior, receiver enable polarity, bus-idle levels, propagation delay, and maximum data rate before substituting MAX3071EASD, MAX3072EASD, MAX3073EASD, SP3070EEN-L/TR, or ISL83070EIBZA-T. The family variants add receiver channels, which can change internal pin allocation even though they use the same 14-pin SOIC outline.
Decouple the 3.3 V transceiver supply close to the device with the capacitance recommended in the MAX3070E-MAX3079E manufacturer data sheet. Keep the supply and ground return path short, and account for transceiver current in the upstream regulator's capacity. If the interface board also contains switching converters, isolate their high-current routing from the receiver input and use the fail-safe receiver to define the state of an inactive bus.
Termination, common-mode biasing, and protection components must be designed for the actual cable length, baud rate, topology, and grounding method. A single termination at each physical end of a long multidrop bus can reduce reflections, while bias resistors must not be duplicated excessively because that can overdrive the bus. Validate the complete network with the longest cable and the specified node count rather than relying only on bench-length cables.
コンプライアンス情報
No explicit compliance declarations were included in the available manufacturer and distributor information. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status with Analog Devices before production release.