MAX3232ECTE+T - 1Mbps True RS-232 Transceiver | Analog Devices
部品番号: MAX3232ECTE+T ✓ 生産中MAX3232ECTE+T 概要
A true RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 line levels and converts received RS-232 signals back into digital logic levels. MAX3232 belongs to the RS-232 transceiver hierarchy within interface ICs, where the dual charge-pump circuit supports the positive and negative voltage swings required by true RS-232. The MAX3232 family is identified by Analog Devices as pin, package, and functionally compatible with the industry-standard MAX232.
Key characteristics include a 3.0 V minimum operating supply, a 5.5 V maximum operating supply, and a data rate of up to 1 Mbps. The device integrates two line drivers and two line receivers. Its low-power design can operate from a 3.3 V system without a separate 5 V supply. The specified 15 kV ESD protection improves robustness on exposed serial connectors, although system-level grounding and cable design remain important.
Internally, the MAX3232 combines its dual charge pump, two transmit drivers, and two receive receivers in one interface device. The charge pump generates the voltage needed for RS-232 output levels, while the receivers include the signal-conditioning functions needed to reject noise and recover logic-level data. The exposed thermal pad supports heat transfer from the device, and the 5 mm by 5 mm package reduces board area compared with larger leaded and SOIC implementations.
Typical uses include industrial serial-port adapters, USB-to-RS-232 equipment, instrumentation interfaces, POS terminals, embedded control systems, and data-acquisition equipment. The 1 Mbps capability supports higher-rate legacy serial links while the 3.3 V supply operation simplifies integration with modern embedded controllers and FPGAs. Designers should still confirm signal levels, connector requirements, and cable length against the complete interface specification.
For a new layout, place the charge-pump capacitors and RS-232 interface components close to their associated pins. Keep the exposed pad connected to the ground plane on a multilayer board, use the recommended via pattern, and provide the interface connector with an appropriate chassis or signal-ground strategy. The MAX3232ECTE+T is supplied in tape-and-reel packaging for automated assembly.
This product page combines the manufacturer specifications, package details, verified lifecycle information, pin-compatible family alternatives, and application-specific design guidance. It also highlights the differences engineers should evaluate when moving between commercial and extended-temperature MAX3232 package variants.
ドロップイン代替品: MAX3232ECTE+T — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MAX3232ECTE+T (同一形状・フットプリント) — 相違点: ESD Protection, Package, Interface Standard, Product Type.
MAX3232ECAE+T
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →MAX3232EATE+T
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX3232ECTE+T 仕様
| Product Type | RS-232 transceiver |
| Transceiver Configuration | 2 transmitters and 2 receivers |
| Supply Voltage Range | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps |
| Interface Standard | True RS-232 |
| ESD Protection | 15 kV |
| Low-Power Shutdown Current | 10 nA |
| パッケージ | 16-pin TQFN with exposed pad, 5 mm x 5 mm |
| 実装タイプ | Surface mount |
| Packing Method | Tape and reel |
| 動作温度範囲 | 0 °C to 70 °C |
MAX3232ECTE+T 16-pin tqfn with exposed pad, 5 mm x 5 mm ピン配置ガイド
MAX3232ECTE+T (16-pin tqfn with exposed pad, 5 mm x 5 mm パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: MAX3232ECTE+T.
詳細は データシート をご参照ください。
主な用途
MAX3232ECTE+T の用途: 6 件s: Industrial Serial-Port Adapters, POS Terminal and Retail Equipment, Data-Acquisition Instruments, Embedded Debug and Service Interfaces, USB-to-RS-232 Adapter, Security and Access-Control Equipment.
Industrial Serial-Port Adapters
The MAX3232ECTE+T fits industrial serial adapters that convert a 3.3 V or 5 V digital controller port into a true RS-232 connection. Its 3.0 V to 5.5 V operating range allows use with both embedded processors and FPGAs, while the two-driver, two-receiver configuration supports bidirectional console and control links. The 1 Mbps maximum data rate is useful for legacy equipment that operates above standard serial-port speeds. The 15 kV ESD protection strengthens the connector-facing interface, but it does not replace a suitable chassis-ground strategy or cable design. In a completed adapter, the digital-side signals connect to the logic controller while the driver and receiver pins connect through protection and signal-conditioning components to the DE-9 or equivalent RS-232 connector.
おすすめ
POS Terminal and Retail Equipment
The MAX3232ECTE+T is appropriate for point-of-sale terminals and peripheral interfaces that retain a true RS-232 port. Two transmitters and two receivers provide balanced bidirectional connectivity, and the 1 Mbps capability offers headroom for service and data-transfer links operating above legacy throughput. Because the device accepts a 3.0 V minimum supply, it can operate directly from a 3.3 V retail controller without a separate 5 V rail. In a terminal design, maintain separation between the switching logic and connector-side routing, place charge-pump capacitors close to the IC, and connect the exposed pad to a low-impedance ground plane. The specified 0 °C to 70 °C range suits ordinary indoor terminal environments but must be reviewed for outdoor kiosks or unheated retail equipment.
おすすめ
Data-Acquisition Instruments
The MAX3232ECTE+T can connect a laboratory or industrial data-acquisition instrument to an RS-232 controller. Its 1 Mbps maximum rate supports faster instrument-control traffic than the common 115.2 kbit/s operating mode, while true RS-232 levels improve compatibility with legacy test equipment. The dual receiver arrangement allows status or handshake signals to be monitored alongside the primary data channel. Place the MAX3232 near the connector-side signal path, keep the exposed pad thermally and electrically connected to ground, and provide local charge-pump capacitors exactly as specified in the manufacturer data sheet. The 15 kV ESD rating helps protect against incidental cable transients, although instrument grounding and isolation determine the ultimate noise performance. A system using long cables should also include appropriate transient protection and verify the receiver thresholds against its installed voltage levels.
おすすめ
Embedded Debug and Service Interfaces
The MAX3232ECTE+T is useful for embedded debug adapters, configuration tools, and service ports that need a true RS-232 electrical interface beside a modern 3.3 V controller. Its minimum operating supply of 3.0 V simplifies integration with low-power processors, and the 1 Mbps capability supports higher-speed debug or bootloader traffic when the target software and cable permit it. The two transmitters and two receivers can carry data and hardware-control signals over one connector. Use short, controlled traces between the controller, MAX3232, and connector, and keep switching regulators and high-current return paths out of the interface region. The exposed pad should be soldered to a ground plane with the recommended thermal-via arrangement. Where field cables enter the enclosure, supplement the IC's 15 kV ESD protection with connector-level design controls appropriate for the installation environment.
おすすめ
USB-to-RS-232 Adapter
The MAX3232ECTE+T serves as the physical-layer interface in a USB-to-RS-232 adapter because it translates 3.3 V or 5 V logic into true RS-232 levels. A USB-to-serial controller operating at 3.3 V can pair directly with the transceiver's 3.0 V minimum supply, avoiding an unnecessary level shifter on the logic side. The 2/2 channel count supports data plus handshake or status signals, and the 1 Mbps capability allows modern USB-to-serial firmware to use elevated baud rates when the attached RS-232 equipment supports them. Keep the charge-pump switching nodes compact, route connector-side traces away from digital and power-converter nodes, and use a continuous ground reference. For a finished adapter, use the MAX3232 data sheet's capacitor values and exposed-pad via pattern to prevent startup, noise, or thermal problems.
おすすめ
Security and Access-Control Equipment
The MAX3232ECTE+T can support access-control readers, controllers, and service tools that communicate through an RS-232 link. The 15 kV ESD protection is particularly relevant where cables connect to frequently touched or exposed equipment, while true RS-232 levels maintain compatibility with established access-control panels. Its dual-driver, dual-receiver arrangement can carry a primary command channel and auxiliary status or handshake signals. The device should be positioned near the connector, with a short and direct return path to protect signal integrity. Do not rely on the MAX3232 alone as a complete surge-protection strategy; add appropriately rated protection when the installation can experience severe transients. For access-control hardware located outside controlled temperature ranges, select an extended-temperature MAX3232E grade and verify the final qualification requirements before manufacturing.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MAX3232ECTE+T — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MAX3232ECAE+T | MAX3232EATE+T |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | TQFN-16 with exposed pad, 5 mm x 5 mm | TQFN-16 with exposed pad, 5 mm x 5 mm | TQFN-16 with exposed pad, 5 mm x 5 mm |
| Transceiver Configuration | 2 transmitters and 2 receivers | 2 transmitters and 2 receivers | 2 transmitters and 2 receivers |
| Supply Voltage Range | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps | 1 Mbps | 1 Mbps |
| ESD Protection | 15 kV | 15 kV | 15 kV |
| Interface Type | True RS-232 | True RS-232 | True RS-232 |
| Packing Method | Tape and reel | Tape and reel | Tape and reel |
主な差別化要因
- Compact exposed-pad interface implementation (vs MAX3232ECDWR)
- 3.3 V-compatible true RS-232 operation (vs MAX3232ECWE+)
- Full dual-channel RS-232 interface (vs MAX3232EATE+T)
設計ノート
Place the MAX3232 charge-pump capacitors and bypass capacitor directly beside their numbered pins using the shortest possible traces. Follow the manufacturer data sheet for capacitance, tolerance, voltage rating, and placement. The exposed pad is both a thermal and electrical connection; solder it to a ground plane and use the recommended thermal-via pattern. Avoid placing the charge-pump routing near sensitive analog inputs because its switching waveform can couple into adjacent nodes.
Keep connector-side RS-232 traces away from clocks, switching-regulator outputs, and high-speed digital nets. Maintain a continuous ground reference beneath the interface path, but follow the connector and cable grounding strategy to control ground currents. If the MAX3232 is positioned away from the connector, route the protected driver and receiver nets together and minimize stubs to reduce susceptibility to external noise and ESD events.
Do not substitute a SOIC or SSOP MAX3232 variant onto the TQFN footprint without redesigning the PCB. MAX3232ECDWR, for example, uses a different package and therefore is not a pin-to-pin drop-in replacement for MAX3232ECTE+T. Also verify the operating-temperature grade before substitution: identical voltage, data-rate, and channel-count ratings do not establish suitability for an environment outside the target device's specified temperature range.
コンプライアンス情報
The MAX3232 family is specified with 15 kV ESD protection. A separate IEC ESD-protection designation is stated for the TI MAX3232E family, but it was not applied to the exact Analog Devices target ordering code. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not established for the exact MPN.