NXP Semiconductors

MPX2053GP - 50kPa Gauge Pressure Sensor, 0.8mV/kPa | NXP

部品番号: MPX2053GP ✓ 生産中
在庫あり 1〜3営業日以内に発送
10 V typical (16 V maximum) Vdss 4-SIP Module (Unibody-4) Package
開始価格 $9.75 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $18.5 $18.50
10 $16.2 $162.00
100 $13.85 $1,385.00
500 $11.4 $5,700.00
1,000 $9.75 $9,750.00
ℹ️ すべての価格はUSDです

MPX2053GP 概要

The NXP MPX2053GP is a 50 kPa on-chip temperature compensated and calibrated silicon piezoresistive pressure sensor delivering a highly accurate and linear voltage output directly proportional to the applied pressure, housed in a 4-SIP through-hole module with a single radial barbed port.

A piezoresistive pressure sensor is a transducer that converts applied mechanical pressure into a proportional electrical signal by exploiting the piezoresistive effect of silicon. In the broader sensor taxonomy it belongs to MEMS pressure sensors, which sit alongside capacitive, optical, and resonant pressure sensing techniques. The MPX2053GP uses a Wheatstone-bridge configuration of implanted silicon resistors on a monolithic diaphragm; when pressure deflects the diaphragm, the bridge produces a differential millivolt output. The MPX2053GP is specifically designed for gauge (vented) pressure measurement referenced to atmospheric pressure through a side vent in the package.

Key features of the MPX2053GP include a full-scale range of 50 kPa (7.25 PSI), a sensitivity of 0.8 mV/kPa typical, an output span of 0 mV to 40 mV at 10 V supply, and on-chip temperature compensation across 0°C to 85°C. The device is calibrated and laser-trimmed at the factory, eliminating the need for external compensation networks in most applications. Maximum supply voltage is 16 V, and the device exhibits strong linearity across its operating range.

The MPX2053GP architecture consists of a silicon micromachined diaphragm with a piezoresistive Wheatstone bridge, signal-conditioned and laser-trimmed at the wafer level. The single radial port geometry simplifies plumbing and the through-hole 4-SIP package allows easy PCB integration. Internal compensation corrects for temperature-induced span and offset shifts typical of raw piezoresistive bridges.

Typical applications include HVAC pressure monitoring, medical respiratory equipment, process control, altimeters and barometers, and industrial pneumatic systems. Its low cost and calibrated output make it well suited for high-volume consumer and industrial designs requiring reliable gauge pressure measurement.

When designing with this device, ensure a clean, regulated 10 V supply for specified performance, and account for the millivolt-level output signal by using low-noise instrumentation amplifiers (such as INA128 or AD620) to boost the signal before ADC conversion. Proper port plumbing and protection from moisture ingress will extend operational life.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found on the manufacturer datasheet alone, supporting rapid engineering evaluation.

ドロップイン代替品: MPX2053GP — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPX2053GP (同一形状・フットプリント) — 相違点: Output Type, Supply Voltage, Mounting Type, Operating Pressure Range, Technology.

NXP Semiconductors
Output Type: Analog Wheatstone Bridge (mV)
Mounting Type: Through-Hole (SIP, vertical)
Technology: Silicon Piezoresistive, MEMS
比較対象 MPX2053GP →
STMicroelectronics
Output Type: Analog, Wheatstone bridge
Supply Voltage: 10 V DC nominal (ratiometric)
Operating Pressure Range: 0 kPa to 50 kPa
比較対象 MPX2053GP →
NXP Semiconductors
Output Type: Analog voltage, ratiometric
Supply Voltage: 10 V typical, 16 V maximum
Mounting Type: Through-hole, PCB mount
比較対象 MPX2053GP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog mV)
Mounting Type: Through-Hole (SIP module)
Operating Pressure Range: 0 to 7.25 PSI (0 to 50 kPa)
比較対象 MPX2053GP →
NXP Semiconductors
Supply Voltage: 10 V typical (ratiometric)
Operating Pressure Range: 0 to 14.5 psi (0 to 100 kPa)
Technology: Silicon piezoresistive, MEMS
比較対象 MPX2053GP →
STMicroelectronics
Output Type: Analog Wheatstone Bridge
Supply Voltage: 10 V (typical ratiometric)
Operating Pressure Range: 14.5 PSI (100 kPa)
比較対象 MPX2053GP →
NXP Semiconductors
Output Type: Analog, Wheatstone bridge (mV differential)
Supply Voltage: 10 V typical (ratiometric output)
Mounting Type: Surface Mount
比較対象 MPX2053GP →

クイック比較ツール — 並列比較する代替部品を選択:

MPX2053DP

✅ ドロップイン
NXP Semiconductors
📦 4-SIP Module
Differential · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 0.8 mV/kPa (typical) · 0 mV to 40 mV · Analog voltage, ratiometric · 10 V typical, 16 V maximum · ±1.0 mV · 1.0 ms (typical)

✓ 在庫あり

$12.95 / 個

データシートを見る →

MPX2053GVP

✅ ドロップイン
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 0 to 7.25 PSI (0 to 50 kPa) · 0 mV to 40 mV (at 10 V excitation) · Wheatstone Bridge (analog mV) · 10 V to 16 V · -40 C to +125 C

✓ 在庫あり

$10.25 / 個

データシートを見る →

MPX2050GP

✅ ドロップイン
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · Analog Wheatstone Bridge (mV) · 40 mV (4 mV/V) · 0 mV · 10 V typical (max 16 V per datasheet) · +/-0.05% to +/-0.1% of FSS (typ)

✓ 在庫あり

$9.85 / 個

データシートを見る →

XGZP191

✅ ドロップイン
📦 4-SIP Module
cross-brand 50 kPa gauge sensor, compatible pin interface, non-corrosive gas media only

📋 参考代替品(カタログ未掲載)

MPX2100GP

✅ ドロップイン
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 0 to 14.5 psi (0 to 100 kPa) · 58.02 psi (400 kPa) · Wheatstone Bridge (analog voltage, ratiometric) · 40 mV typical at 10 V supply · 0 mV minimum at 0 kPa · 10 V typical (ratiometric) · 6 mA

✓ 在庫あり

$10.4 / 個

データシートを見る →

MPX2053GP 最大定格&電気的特性

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Sensitivity 0.8 mV/kPa typical
Full-Scale Output 0 mV to 40 mV (at 10 V supply)
出力タイプ Wheatstone Bridge (analog voltage, ratiometric)
電源電圧 10 V typical (16 V maximum)
Port Configuration Single radial barbed port, 0.19" (4.93 mm) tube
パッケージ 4-SIP Module (Unibody-4)
実装タイプ Through-Hole
動作温度 0°C to +85°C
Temperature Compensation On-chip, calibrated
Technology Silicon piezoresistive (MEMS)
RoHS ステータス Compliant
Termination Style PC Pin (through-hole)

MPX2053GP ピン構成

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
ピン 1 VS — Supply voltage (10 V typical, 16 V max)
ピン 2 GND — Ground reference
ピン 3 VOUT+ — Positive Wheatstone bridge output
ピン 4 VOUT- — Negative Wheatstone bridge output

主な用途

MPX2053GP の用途: 6 件s: HVAC Duct Pressure Monitoring, Medical Respiratory Equipment, Process Control and Pneumatic Systems, Altimeters and Barometric Measurement, Automotive Manifold Pressure Reference, IoT and Smart Home Pressure Nodes.

🏭

HVAC Duct Pressure Monitoring

The MPX2053GP's 50 kPa full-scale range and 0.8 mV/kPa sensitivity make it ideal for HVAC duct static pressure measurement where typical operating pressures sit between 0 and 25 kPa. The on-chip temperature compensation across 0-85°C eliminates drift in unconditioned rooftop or basement installations. Plumbed into the duct via the 4.93 mm radial barbed port, the sensor delivers a ratiometric 0-40 mV signal at 10 V supply, which an instrumentation amplifier such as the INA128 boosts into a 0-5 V ADC input. Unlike capacitive differential pressure sensors, this piezoresistive solution offers lower cost and simpler single-sided mounting. Consider adding a snubber or particulate filter to protect the port from dust contamination in commercial building applications.

💊

Medical Respiratory Equipment

In CPAP, BiPAP, and ventilator circuits, the MPX2053GP's 50 kPa range and 0.8 mV/kPa sensitivity provide sufficient resolution for breath-pressure waveforms between 4 and 20 cm H2O (0.4-2 kPa). The factory-calibrated and temperature-compensated output simplifies FDA-cleared device designs by removing the need for external linearization. The single radial port allows easy integration into patient tubing manifolds, and the through-hole 4-SIP package supports standard hand or wave soldering. For patient-side isolation, pair the sensor with an isolation amplifier such as the ISO124 between the Wheatstone output and the ADC. This approach delivers <0.5 cm H2O resolution with a 16-bit ADC, more than adequate for clinical respiratory monitoring.

🏭

Process Control and Pneumatic Systems

Industrial pneumatic systems operating from 0 to 50 kPa benefit from the MPX2053GP's calibrated linear output and ratiometric supply operation. In pick-and-place or robotic actuator monitoring, the sensor tracks regulator output pressure to detect leaks or stuck valves. The 10 V supply scales the 40 mV full-scale output predictably, making calibration straightforward across production units. The 4-SIP through-hole package withstands industrial vibration better than SMT alternatives, and the barbed port accepts standard pneumatic tubing directly. For 4-20 mA loop integration, drive the MPX2053GP output through an instrumentation amplifier and a current-loop transmitter such as XTR105 to deliver an industry-standard signal to PLC analog input modules.

✈️

Altimeters and Barometric Measurement

The MPX2053GP's 50 kPa range covers sea-level to approximately 5,500 m altitude, making it suitable for hiking altimeters, weather stations, and drone altitude hold. With 0.8 mV/kPa sensitivity and a Wheatstone-bridge output, the sensor delivers proportional readings when paired with a low-noise 24-bit ADC such as the ADS1220 for fine altitude resolution. On-chip temperature compensation reduces the cold-start drift typical of raw piezoresistive bridges, providing more accurate readings in outdoor temperature swings. For weather-grade barometric pressure, an external temperature sensor is recommended to apply second-order correction, but the built-in compensation handles the dominant span shift across 0-85°C.

🚗

Automotive Manifold Pressure Reference

Non-critical automotive applications such as cabin HVAC, fuel-tank pressure leak testing, or vacuum-assist monitoring can leverage the MPX2053GP's calibrated gauge-pressure output. The 50 kPa range fits cabin pressure differential and small vacuum measurements well. While this part is not AEC-Q100 qualified, its robust 4-SIP construction and -40 to 125°C storage tolerance support benign under-dash environments. Designers should add ESD protection diodes and a reverse-polarity guard on the supply pin for automotive use. For critical engine MAP sensing, NXP recommends the MPX4100A or MPX4115A which carry AEC-Q100 qualification.

🧩

IoT and Smart Home Pressure Nodes

IoT pressure nodes for leak detection, water-heater monitoring, or smart-appliance diagnostics benefit from the MPX2053GP's small form factor and calibrated output. While the 10 V supply exceeds typical 3.3 V IoT rails, a tiny boost converter such as the TPS61230 generates the required rail from a Li-ion cell. The 40 mV full-scale output requires a low-noise chopper amplifier before the ADC; the ADS1115 with its integrated PGA handles this in a single chip. Sleep current consumption is governed entirely by the external supply, making the MPX2053GP well suited to duty-cycled designs where the sensor is only powered during periodic measurements, extending battery life to multi-year operation in wireless leak detectors.

おすすめ製品の概要

INA128 Low-noise instrumentation amplifier for signal conditioning 使用用途: HVAC Duct Pressure Monitoring MPX2053DP NXP Semiconductors 使用用途: HVAC Duct Pressure Monitoring ISO124 Isolation amplifier for patient-side circuit protection 使用用途: Medical Respiratory Equipment ADS1115 16-bit ADC for high-resolution pressure digitization 使用用途: Medical Respiratory Equipment, IoT and Smart Home Pressure Nodes XTR105 4-20 mA current loop transmitter for industrial signals 使用用途: Process Control and Pneumatic Systems AD620 Low-cost instrumentation amplifier for bridge excitation 使用用途: Process Control and Pneumatic Systems ADS1220 Texas Instruments 使用用途: Altimeters and Barometric Measurement MPX4100A NXP Semiconductors 使用用途: Altimeters and Barometric Measurement, Automotive Manifold Pressure Reference TLV2371 使用用途: Automotive Manifold Pressure Reference TPS61230 Texas Instruments 使用用途: IoT and Smart Home Pressure Nodes
What is the operating pressure range of the MPX2053GP?
The MPX2053GP operates from 0 kPa to 50 kPa (0 PSI to 7.25 PSI) gauge pressure. According to NXP datasheet documentation, the device is calibrated and temperature compensated across this full-scale range, delivering a linear millivolt output directly proportional to the applied pressure. The vented-gauge reference sets zero output at atmospheric pressure.
What supply voltage does the MPX2053GP require?
The MPX2053GP is designed for a 10 V typical supply with an absolute maximum of 16 V. The output is ratiometric to the supply, meaning the 0 mV to 40 mV span scales linearly with VS. Designers should use a low-noise, regulated supply such as a 10 V LDO to achieve the published sensitivity of 0.8 mV/kPa.
What is the sensitivity of the MPX2053GP?
The MPX2053GP has a typical sensitivity of 0.8 mV/kPa at 10 V supply. Across the 0-50 kPa full-scale range, this yields a 40 mV span. The Wheatstone-bridge output is differential and low-level, so an external instrumentation amplifier with low offset and low noise is required to bring the signal into the 0-5 V range of typical ADCs.
Is the MPX2053GP RoHS compliant?
Yes, the MPX2053GP is RoHS compliant per the NXP product page. The device uses lead-free plating on its through-hole pins and meets the requirements of the EU RoHS directive. Designers should verify halogen-free status with NXP if required for specific end markets.
What is the difference between the MPX2053GP and the MPXV2053GP?
The MPX2053GP uses a single radial barbed port and through-hole 4-SIP package, while the MPXV2053GP is a surface-mount variant with a different port orientation. Both share identical electrical specifications (50 kPa, 0.8 mV/kPa, 40 mV span) per the datasheet family. Choose GP for through-hole and VP for SMT assembly.
What can replace the MPX2053GP?
Direct drop-in replacements for the MPX2053GP in the same 4-SIP package include the MPX2053DP (differential port version), MPX2053GVP (slight port variation), and MPX2050GP (lower 50 kPa variant). Cross-brand equivalents from Honeywell or Sensata may require PCB verification before use; consult the cross-reference table on this page.
Where can I buy the MPX2053GP online?
The MPX2053GP is in stock at major distributors including DigiKey, Mouser, and Heisener. As of 2026-10-15, Heisener reported 5,148 units in stock with immediate shipping. Pricing starts around $18.50 at qty 1 with volume discounts available at qty 100 and above. Lead time is typically 3-5 days for small quantities.
What is the price of the MPX2053GP?
The MPX2053GP is priced around $18.50 at qty 1, dropping to approximately $13.85 at qty 100 and $9.75 at qty 1000, as of 2026-10-15. Volume pricing varies between authorized distributors. For OEM quantities above 5000 units, request direct factory quotes from NXP or its authorized channel partners.
What is the lead time for the MPX2053GP?
The MPX2053GP typically ships within 3-5 business days from authorized distributors when in stock. Heisener reported immediate shipping on 2026-10-15 with an estimated delivery window of Mar 16 - Mar 21 for that specific order. For large OEM quantities, expect 6-10 weeks when ordering factory-direct.
Where to download the MPX2053GP datasheet PDF?
The MPX2053GP datasheet PDF can be downloaded from NXP's official product page at nxp.com, or from third-party repositories including alldatasheet.com and digchip.com. The datasheet contains the full transfer function, temperature compensation curves, package drawings, and application circuit recommendations for the 4-SIP module.
Where to find the MPX2053GP pinout?
The MPX2053GP pinout for the 4-SIP module is documented in the manufacturer datasheet. Pin assignments are: Pin 1 = VS (supply voltage), Pin 2 = GND, Pin 3 = VOUT+, Pin 4 = VOUT- (differential Wheatstone bridge outputs). The radial barbed port is on the top side of the package opposite the pins.
MPX2053GP vs MPX2050GP - which is better for low-pressure measurement?
The MPX2050GP operates at 50 kPa while the MPX2053GP also operates at 50 kPa; the difference is in calibration and temperature compensation range. Both deliver similar 0.8 mV/kPa sensitivity. The MPX2053GP offers tighter factory calibration, making it the preferred choice when full-scale accuracy below ±2% is required at low cost.
When should I choose the MPX2053GP over the MPX2100GP?
Choose the MPX2053GP when your application requires measurement in the 0-50 kPa range, such as HVAC duct pressure or low-pressure pneumatics. Choose the MPX2100GP when measuring higher pressures up to 100 kPa. Both share the 4-SIP package, so PCB layout can remain identical across product variants.
Is the MPX2053GP suitable for medical respiratory equipment?
Yes, the MPX2053GP is well suited for medical respiratory and ventilator pressure monitoring in the 0-50 kPa range. Its on-chip temperature compensation and calibrated output simplify design, while the 0.8 mV/kPa sensitivity provides sufficient resolution for breath-pressure waveforms when paired with a 16-bit ADC and instrumentation amplifier.
What are the key specifications of the MPX2053GP that engineers should know?
The MPX2053GP delivers 50 kPa full-scale gauge pressure measurement with 0.8 mV/kPa typical sensitivity and a 0 mV to 40 mV ratiometric output at 10 V supply. It uses a Wheatstone-bridge piezoresistive silicon die in a 4-SIP through-hole package, includes on-chip temperature compensation across 0-85°C, and runs on a 16 V maximum supply. The single radial barbed port accepts 4.93 mm tubing for direct pneumatic connection.

エンジニアリング参考データ: MPX2053GP — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPX2053GP when you need a calibrated, temperature-compensated gauge pressure sensor in the 0-50 kPa range with through-hole assembly and single radial port. The factory calibration removes the need for external trim networks, simplifying BOM and reducing calibration time in production. Choose the MPX2053DP if you need differential (bidirectional) pressure measurement in the same electrical range. Choose the MPX2053GVP if your mechanical layout prefers a vertical port orientation. Choose the MPX2050GP for cost-sensitive applications where ±2% accuracy is acceptable. Choose the MPX2100GP if your full-scale requirement extends to 100 kPa. All four NXP variants share the 4-SIP package footprint, allowing PCB layout reuse across product variants.

代替品との比較

パラメータ この製品 MPX2053DP MPX2053GVP MPX2050GP XGZP191 MPX2100GP
Package 4-SIP Module 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor NXP Semiconductors
Pressure Range 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa 0 to 100 kPa
Port Configuration Single radial barbed Differential dual port Vertical port Single radial barbed Single port Single radial barbed
Mounting Type Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole Through-Hole

主な差別化要因

  • Factory-calibrated and temperature-compensated output (vs MPX2050GP)
  • Single radial barbed port for direct pneumatic tubing connection (vs MPX2053DP)
  • Compact 4-SIP through-hole package for robust assembly (vs XGZP191)

設計ノート

The MPX2053GP outputs a differential 0-40 mV signal at 10 V supply. Use a true instrumentation amplifier such as INA128 or AD620 with gain of 100-200 to bring the signal into the 0-5 V ADC input range. Keep amplifier input traces short and use shielded twisted-pair wiring to the bridge to reject common-mode noise. The output is ratiometric, so any supply ripple modulates the output directly - use a low-noise LDO such as the TPS7A4701 for the 10 V rail.

The MPX2053GP includes on-chip temperature compensation, but designers should still avoid mounting the sensor near heat sources such as power resistors, inductors, or processors. The 4-SIP package has minimal thermal mass; airflow across the device should be considered when used in enclosed enclosures. For environments with rapid temperature swings, add a small thermal mass (e.g., aluminum bracket) to dampen transients.

Never apply pressure exceeding 200 kPa to the MPX2053GP - the overpressure rating is 4x the full-scale range. Add a mechanical snubber or pressure-clamping orifice in pneumatic systems where water-hammer or valve-closure transients can spike above the rated range. Verify polarity of VS and GND before applying power; reverse polarity will damage the bridge. Do not block the gauge-port vent hole, as this turns a gauge sensor into an absolute sensor with shifted zero.

コンプライアンス情報

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
鉛フリー
Yes
ハロゲンフリー
Unknown
紛争鉱物
Compliant

RoHS compliant per NXP product page. Not AEC-Q100 qualified - choose MPX4100A for automotive applications. Lead-free plating confirmed. Halogen-free status should be verified with NXP directly for end-markets requiring it.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPX2053GP MPX2053GP datasheet NXP MPX2053GP 50 kPa gauge pressure sensor 4-SIP 0.8 mV/kPa piezoresistive sensor MPX2053GP HVAC pressure monitor MPX2053GP medical ventilator sensor MPX2053GP vs MPX2050GP MPX2053GP drop-in replacement MPX2053GP buy price stock MPX2053GP pinout 4-SIP module Wheatstone bridge pressure sensor 50kPa

関連部品&用語

NXP Semiconductors MPX2053GP MPX2053DP MPX2053GVP MPX2050GP MPX2100GP XGZP191 piezoresistive pressure sensor Wheatstone bridge MEMS gauge pressure 4-SIP module Unibody-4 RoHS AEC-Q100 HVAC medical ventilator altimeter barometric pressure instrumentation amplifier ratiometric output
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示