NXP Semiconductors

MPXV2053GP - 50kPa Pressure Sensor | NXP | mV Output

部品番号: MPXV2053GP ✗ 生産終了
在庫あり 1〜3営業日以内に発送
10 V typical (ratiometric output) Vdss 8-SMD, Gull Wing, Side Port Package
開始価格 $10.5 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $18.5 $18.50
10 $16.2 $162.00
100 $14 $1,400.00
500 $12.1 $6,050.00
1,000 $10.5 $10,500.00
ℹ️ すべての価格はUSDです

MPXV2053GP 概要

The NXP MPXV2053GP is a 50 kPa on-chip temperature-compensated and calibrated silicon piezoresistive pressure sensor that delivers a highly accurate, linear voltage output directly proportional to applied pressure. Housed in an 8-SMD gull-wing package with a top-side port, the device operates from 0 to 50 kPa (0 to 7.25 PSI) in vented gauge configuration and produces a 0 mV to 40 mV differential output when driven from a 10 V supply, capturing pressure through a male 0.13" (3.17 mm) tube port. The "V" vent hole beside the port provides reference to atmospheric pressure for true gauge reading.

A pressure sensor is a transducer that converts an applied physical pressure into a proportional electrical signal, used wherever a system must monitor or react to fluid or gas pressure. Within the broader taxonomy, the MPXV2053GP belongs to the sensor family, more specifically to piezoresistive (silicon strain-gauge) pressure sensors, and within that to the mV-output (uncompensated or partially compensated) subclass that requires an external signal-conditioning chain. Its on-chip temperature compensation and calibration distinguish it from bare die-strain elements, eliminating the need for external compensation circuits in many low-precision applications.

Key features of the MPXV2053GP include factory calibration, on-chip temperature compensation over 0°C to +85°C, excellent linearity across the 0–50 kPa range, and very low hysteresis. The sensor uses a single axial port with a tube interface, allowing direct pneumatic connection to the manifold under test. The 8-SMD form factor supports automated assembly, and the top-side port orientation simplifies manifold design in vertical-mount pressure assemblies. Output is ratiometric to supply voltage, meaning a 5 V supply halves the full-scale output to about 20 mV.

Typical applications include HVAC differential pressure sensing, medical inhalation and respiratory monitoring equipment, industrial process control and level measurement, altimeters and barometric instruments, and pneumatic control in fuel-cell and analytical instruments. The 50 kPa full-scale range is well suited to low-pressure gas and dry-air measurements where differential pressures span a few kPa up to nearly 1 atm of gauge pressure.

When designing with this part, plan for a low-noise, high-gain instrumentation amplifier (such as an INA125 or AD620 with gain of about 100) because the native 40 mV full-scale output is too small for direct ADC digitization in 12-bit systems. Provide adequate PCB isolation between the digital ground and the analog ground star-point near the sensor’s ground pins to avoid corrupting the small millivolt signal.

ドロップイン代替品: MPXV2053GP — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPXV2053GP (同一形状・フットプリント) — 相違点: Output Type, Operating Pressure Range, Operating Temperature, Package, Supply Voltage.

NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage, ratiometric)
Operating Temperature: 0°C to +85°C
Package: 4-SIP Module (Unibody-4)
比較対象 MPXV2053GP →
STMicroelectronics
Output Type: Analog, ratiometric, mV output
Operating Pressure Range: 0 kPa to 10 kPa
Operating Temperature: -40 C to +125 C
比較対象 MPXV2053GP →
STMicroelectronics
Output Type: Analog Voltage (mV)
Operating Pressure Range: 0 kPa to 50 kPa
Operating Temperature: 0 C to +85 C
比較対象 MPXV2053GP →

クイック比較ツール — 並列比較する代替部品を選択:

MPXV2050GP

✅ ドロップイン ⚠️ 仕様未検証
📦 8-SMD, Gull Wing, Top Port
same 8-SMD top-port footprint, pin-to-pin compatible, similar pressure range

📋 参考代替品(カタログ未掲載)

MPXV2053DP

✅ ドロップイン ⚠️ 仕様未検証
STMicroelectronics
📦 8-SMD, Gull Wing, Dual Port
Differential · 0 kPa to 50 kPa · 200 kPa · Analog Voltage (mV) · 0 mV to 40 mV · 0.8 mV/kPa · 10 V nominal (16 V max) · Male tube, 0.13 in (3.3 mm) dual ports, same side

✓ 在庫あり

$10.62 / 個

データシートを見る →

XGZP193

✅ ドロップイン
📦 8-SMD, Gull Wing, Top Port
third-party replacement, compensated mV output, 0-50 kPa version available

📋 参考代替品(カタログ未掲載)

MPX2053GP

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 8-SMD, Gull Wing, Top Port
Vented Gauge · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 0.8 mV/kPa typical · 0 mV to 40 mV (at 10 V supply) · Wheatstone Bridge (analog voltage, ratiometric) · 10 V typical (16 V maximum) · Single radial barbed port, 0.19" (4.93 mm) tube · 4-SIP Module (Unibody-4)

✓ 在庫あり

$9.75 / 個

データシートを見る →

MPXV2010GP

✅ ドロップイン ⚠️ 仕様未検証
STMicroelectronics
📦 8-SMD, Gull Wing, Top Port
Vented Gauge · 0 kPa to 10 kPa · 75 kPa · 10 V typical (max 16 V) · 25 mV nominal at 10 kPa · 0 mV to 1.0 mV · 1.0 kPa (typical) · 2.5 mV/kPa nominal at 10 V

✓ 在庫あり

$8.62 / 個

データシートを見る →

MPXV2053GP 最大定格&電気的特性

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
出力タイプ Analog, Wheatstone bridge (mV differential)
Output Span 0 mV to 40 mV (typ) at 10 V supply
電源電圧 10 V typical (ratiometric output)
Port Style Top-side, male tube 0.13" (3.17 mm)
パッケージ / ケース 8-SMD, Gull Wing, Side Port
実装タイプ Surface Mount
Temperature Compensation On-chip, calibrated
Technology Silicon piezoresistive (MEMS strain gauge)
Media Compatibility Dry non-corrosive gases

MPXV2053GP ピン構成

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
ピン 1 VCC — Supply voltage (10 V typ)
ピン 2 GND — Ground
ピン 3 VOUT+ — Positive differential output (mV)
ピン 4 VOUT- — Negative differential output (mV)
ピン 5 NC — Not connected
ピン 6 NC — Not connected
ピン 7 NC — Not connected
ピン 8 NC — Not connected

主な用途

MPXV2053GP の用途: 6 件s: HVAC Differential Pressure Sensing, Medical Inhalation and Respiratory Monitoring, Altimeters and Barometric Instruments, Industrial Process Control and Level Sensing, Pneumatic Control in Fuel-Cell and Analytical Instruments, Vortex and Flow Metering Systems.

🏢

HVAC Differential Pressure Sensing

The MPXV2053GP’s 0–50 kPa range covers the typical differential pressures measured across HVAC filters, fans, and variable-air-volume boxes. Its on-chip temperature compensation keeps the millivolt output stable across the 0–85°C air-handler operating envelope, eliminating the need for external thermistor networks. The vented-gauge port references ambient barometric pressure, so readings track true duct pressure rather than absolute pressure — ideal for filter-loading alarms. Outputs feed a low-noise instrumentation amp (e.g. INA125) with gain ≈100 to bring the 40 mV full-scale up to ADC range. Because the part is obsolete, plan inventory or move to the XGZP193 for new builds.

💊

Medical Inhalation and Respiratory Monitoring

Respiratory instruments require accurate low-pressure gas measurement between -5 kPa and +50 kPa, well within the MPXV2053GP’s range. The small 0.13" tube port fits standard medical pneumatic fittings, simplifying hose interface design. The piezoresistive silicon diaphragm responds quickly to breathing-cycle pressure changes, and on-chip temperature compensation maintains accuracy over the 15–35°C clinical operating window. The millivolt-level output demands a high-CMRR amplifier such as AD620 to reject 50/60 Hz mains pickup on long patient cables. Note that for new medical designs the obsolescence of the MPXV2053GP drives engineering toward the XGZP193 or modern NXP families.

✈️

Altimeters and Barometric Instruments

Atmospheric pressure at sea level is about 101 kPa with a 1 kPa change roughly every 100 m of altitude, so the MPXV2053GP’s 50 kPa range captures meaningful altitude changes in handheld and weather-station altimeters when calibrated against a known reference. The vented-gauge configuration directly references atmospheric pressure through the port, avoiding absolute-pressure drift over time. Calibration routines stored in the host microcontroller map mV readings to elevation via the standard atmosphere model. The 8-SMD surface-mount package supports compact PCB layouts for handheld and wearable enclosures. For new designs the obsolescence of the MPXV2053GP directs engineers to pin-compatible XGZP193 or MPX2053 family variants.

🏭

Industrial Process Control and Level Sensing

Tank-level sensing via hydrostatic head pressure produces signals in the low kilopascal range when measuring water columns of a few hundred millimeters — squarely within the MPXV2053GP’s 0–50 kPa envelope. Pneumatic control loops in analytical instruments also operate in this pressure band. The on-chip calibration compensates the millivolt output for the thermal gradients found in industrial enclosures, and the small SMD package fits inside compact process transmitters. Designers pair the sensor with a current-loop (4–20 mA) transmitter IC such as XTR105 to deliver industrial-standard analog signals to PLCs. Since the MPXV2053GP is EOL, both retrofit (existing designs) and forward-looking builds should evaluate the XGZP193 or NXP MPX family updates.

⚡

Pneumatic Control in Fuel-Cell and Analytical Instruments

Analytical instruments such as gas chromatographs and fuel-cell test stations need precise low-pressure gas monitoring around 0–50 kPa for flow control and leak detection. The MPXV2053GP’s vented-gauge configuration isolates the sensor from absolute atmospheric drift while still registering small differential pressures in the gas line. The millivolt output interfaces cleanly with a precision 24-bit ADC, and on-chip temperature compensation reduces the thermal drift typically encountered in heated analyzer enclosures. Engineers use the sensor to detect blockage in fuel-cell hydrogen lines where a pressure rise indicates flow restriction. Pair it with an instrumentation amp and a sealed NXP MPX pressure sensor at a higher range for differential measurement.

🎡

Vortex and Flow Metering Systems

Industrial flow meters detect pressure pulses generated by vortex shedding behind a bluff body in the flow stream; the resulting differential pressure signal lies in the 0–50 kPa band that the MPXV2053GP measures directly. The piezoresistive element’s high sensitivity resolves small pressure pulses even at low flow rates, and the small tube port adapts to standard process-piping adapters. Instrument designers follow the sensor with a low-pass filter and high-gain instrumentation amp to extract the vortex frequency (proportional to flow velocity). Always plumb the high-pressure side to the sensor port and the low-pressure side to the vent port for proper vented-gauge operation.

おすすめ製品の概要

INA125 Low-noise instrumentation amplifier for sensor signal conditioning 使用用途: HVAC Differential Pressure Sensing, Pneumatic Control in Fuel-Cell and Analytical Instruments MPXV2010GP STMicroelectronics 使用用途: HVAC Differential Pressure Sensing XGZP193 Modern drop-in replacement sensor 使用用途: HVAC Differential Pressure Sensing, Industrial Process Control and Level Sensing AD620 Low-noise instrumentation amplifier for medical signal chain 使用用途: Medical Inhalation and Respiratory Monitoring, Altimeters and Barometric Instruments, Industrial Process Control and Level Sensing, Vortex and Flow Metering Systems MPXV7027GP Higher-range NXP pressure sensor for inspiratory limb 使用用途: Medical Inhalation and Respiratory Monitoring ADS131A04 24-bit ADC for high-resolution pressure digitization 使用用途: Medical Inhalation and Respiratory Monitoring, Pneumatic Control in Fuel-Cell and Analytical Instruments MPL3115A2 I2C altimeter/barometer companion IC 使用用途: Altimeters and Barometric Instruments MAX11209 20-bit ADC for high-resolution barometric measurement 使用用途: Altimeters and Barometric Instruments, Vortex and Flow Metering Systems XTR105 4-20 mA current-loop transmitter for industrial signal 使用用途: Industrial Process Control and Level Sensing MPX4250GP NXP Semiconductors 使用用途: Pneumatic Control in Fuel-Cell and Analytical Instruments MPXV7007GP STMicroelectronics 使用用途: Vortex and Flow Metering Systems
What is the operating pressure range of the MPXV2053GP?
According to the NXP/Freescale MPX2053 datasheet, the MPXV2053GP operates from 0 kPa to 50 kPa (0 PSI to 7.25 PSI) in vented gauge configuration. The output span is typically 0 mV to 40 mV at a 10 V supply, with the output ratiometric to the supply so 5 V operation halves the full-scale output to about 20 mV.
Is the MPXV2053GP still in production?
No. According to the NXP community and verified distributor data, the MPXV2053GP is discontinued, with NXP PCN15504 documenting the EOL years ago. There is no direct drop-in replacement from NXP; equivalent functionality exists in the form of the NXP MPX2053 family in different packages and from third-party suppliers.
What supply voltage does the MPXV2053GP need?
The MPXV2053GP is designed for a 10 V typical supply but the output is ratiometric, so the part operates over a wide supply range with the full-scale millivolt output scaling linearly with VCC. Engineers commonly drive it from 5 V rails (yielding about 20 mV full-scale) when downstream gain stages compensate with higher amplifier gain.
Do I need an amplifier with the MPXV2053GP?
Yes. The 40 mV full-scale output is far too small for direct 12-bit or 16-bit ADC input (1 LSB at 5 V full-scale is about 1.2 mV). A low-noise instrumentation amplifier such as the INA125 or AD620 with gain of about 100 is normally used to bring the signal up to a 4 V full-scale for the ADC.
Where to buy MPXV2053GP today?
Because the MPXV2053GP is obsolete, current stock exists primarily at franchised distributors (DigiKey, Mouser) in declining quantities and at independent distributors. As of 2026-10-15, DigiKey and Mouser product pages still list the part though inventory is shrinking; lead times for fresh orders may exceed 12 weeks.
What is the MPXV2053GP package style?
The MPXV2053GP comes in an 8-SMD gull-wing package with a side (axial) pressure port accepting a male 0.13" (3.17 mm) tube. The "GP" suffix in the MPX naming indicates the package/tray configuration; the vent hole beside the port references atmospheric pressure for vented-gauge operation.
MPXV2053GP vs MPXV2050GP - which is better?
Both parts use the same 8-SMD top-port package and identical pinout. The MPXV2050GP is specified for a 0 kPa to 50 kPa range but with about 40 mV full-scale in some configurations, while the MPXV2053GP shares that pressure envelope. For drop-in compatibility check the exact full-scale output and port orientation in the manufacturer datasheets before substitution.
Can MPXV2053GP be replaced without PCB redesign?
Yes, several modern drop-in alternatives including the CFSensor XGZP193 series and updated NXP MPX2053 family variants share the 8-SMD top-port footprint. According to cross-reference data, the XGZP193 covers 0–10/50/100/200 kPa ranges with similar compensated mV output and is pin-compatible in most MPXV2053GP layouts.
Is the MPXV2053GP media-compatible with water or oil?
No. The MPXV2053GP is specified for dry non-corrosive gases such as air; the silicon diaphragm and adhesive ports are not rated for direct liquid contact. For water or oil media use a stainless-steel-isolated pressure sensor such as the MPXV7027 series with a protective media barrier.
What is the operating temperature range of MPXV2053GP?
According to the NXP MPX2053 datasheet family, the compensated operating range is 0°C to +85°C, and the device survives storage from -40°C to +125°C. On-chip temperature compensation calibrates the output across the 0–85°C compensated range to minimize span and offset drift over temperature.
Where to download MPXV2053GP datasheet PDF?
The original Freescale/NXP MPX2053 datasheet family PDF is available on alldatasheet.com and through NXP’s legacy product archive. The DigiKey product page (digikey.com/en/products/detail/nxp-usa-inc/MPXV2053GP/951834) also links to the manufacturer datasheet PDF directly from the product listing.
What are the typical applications of MPXV2053GP?
The MPXV2053GP is widely used in HVAC differential pressure sensing, medical inhalation and respiratory monitoring equipment, altimeters, barometric instruments, and industrial process control. Its 50 kPa range covers low-pressure gas applications up to roughly half an atmosphere of gauge pressure in clean dry air systems.
What are the key specifications engineers should know about MPXV2053GP?
Engineers designing with the MPXV2053GP should remember: 0–50 kPa gauge range, 0–40 mV differential output at 10 V supply, on-chip temperature compensation over 0–85°C, 8-SMD top-port package, and the requirement for a low-noise instrumentation amplifier (gain ~100) to reach ADC-usable voltage levels. Output is ratiometric to VCC.
What is the best NXP equivalent for MPXV2053GP?
Because the MPXV2053GP has no direct NXP successor, the closest in-family substitutes are the MPXV2050GP (same package, similar range) and the modern NXP MPX2053 in updated packaging. Engineers who want drop-in pin compatibility without re-laying out the PCB should consider third-party cross-vendor equivalents like the CFSensor XGZP193 family.
Is the MPXV2053GP RoHS compliant?
The MPXV2053GP was originally released under Motorola/Freescale before RoHS enforcement tightened across the sensor industry. The exact RoHS status depends on date-code: later date-codes (post-2008) carry RoHS-compliant finishes, while older date-codes may use SnPb terminations. Always confirm RoHS status with the distributor and your supplier before placing production orders.

エンジニアリング参考データ: MPXV2053GP — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPXV2053GP for legacy designs, retrofit repairs, and existing inventory where you cannot re-layout the PCB. The part gives 0–50 kPa vented-gauge operation with on-chip temperature compensation and a top-side tube port that drops into an 8-SMD gull-wing land pattern. For NEW designs, prefer the CFSensor XGZP193 (active, third-party drop-in with multiple pressure range options) or modern NXP MPX2053 family updates to avoid obsolescence risk. Choose the MPXV2053DP variant for differential-pressure applications where two ports are needed; choose the MPXV2010GP for narrow-range measurements below 10 kPa.

代替品との比較

パラメータ この製品 MPXV2050GP MPXV2053DP XGZP193 MPX2053GP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor NXP Semiconductors
Package 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing, Dual Port 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing, Top Port
Pressure Type Vented Gauge Vented Gauge Differential Gage Vented Gauge
Operating Pressure Range 0 to 50 kPa (0 to 7.25 PSI) 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa (also 10/100/200 kPa versions) 0 to 50 kPa
Supply Voltage 10 V typical 10 V typical 10 V typical 5 V typical 10 V typical
Port Style Top, 0.13" tube Top, 0.13" tube Dual Top, 0.13" tube Top, 0.13" tube
Status Obsolete (PCN15504) Obsolete Active Active Obsolete

主な差別化要因

  • On-chip temperature compensation and calibration (vs Bare silicon strain gauge)
  • Vented-gauge port with top-side tube (vs Absolute-pressure sensor)
  • Industry-standard 8-SMD top-port footprint (vs Custom or through-hole pressure sensor packages)

設計ノート

Estimated: with a native output of 40 mV at 10 V, you need an instrumentation amplifier with gain of about 100 to bring the signal up to ~4 V full-scale for a 12-bit ADC at 5 V. Choose a low-noise amp with at least 100 dB CMRR (e.g. INA125, AD620). Place the amp within a few centimeters of the sensor to keep the high-impedance millivolt lines short, and use a Kelvin connection from the sensor GND to the amp’s REF pin to avoid ground loops.

Route the high-impedance mV signal traces on a separate analog ground island that joins the system ground at a single star-point near the sensor. Keep digital and switching-converter traces away from the sensor bond area. The vent hole beside the tube port must remain unobstructed — do not place components within 3 mm of the vent or seal the vent with conformal coating. Use a sealed 8-SMD land pattern with sufficient copper pour under the thermal-pad area for mechanical stability.

Estimated: despite on-chip temperature compensation over 0–85°C, the sensor still exhibits residual TCO and TCS errors in the datasheet; if the application operates near the temperature extremes, perform a two-point calibration (zero at minimum temperature, span at nominal) at the system level. Mount the sensor away from heat sources such as power inductors and MOSFETs because the silicon die is small and tracks local PCB temperature quickly.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

Part is obsolete (NXP PCN15504). RoHS status depends on date-code and is not extractable from the verified web data provided; check with the distributor or alternate supplier before placing new orders.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPXV2053GP MPXV2053GP datasheet PDF NXP MPXV2053GP 50 kPa pressure sensor mV output MPXV2053GP 8-SMD top port MPXV2053GP HVAC sensor MPXV2053GP vs MPXV2050GP MPXV2053GP drop-in replacement MPXV2053GP buy price obsolete MPXV2053GP pinout How does a piezoresistive pressure sensor work MPXV2053GP amplifier circuit

関連部品&用語

NXP Semiconductors Freescale Semiconductor MPXV2053GP MPXV2050GP MPXV2053DP MPX2053GP XGZP193 pressure sensor piezoresistive pressure sensor MEMS strain gauge Wheatstone bridge vented gauge millivolt output (mV) top-side port 8-SMD gull-wing on-chip temperature compensation calibration RoHS PCN15504 INA125 AD620 XTR105 HVAC medical respiratory monitoring altimeter
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示