NXP Semiconductors

MPXA4100AC6U - 105 kPa Absolute Pressure Sensor | NXP | Automotive MAP

部品番号: MPXA4100AC6U ✓ 生産中
在庫あり 1〜3営業日以内に発送
0.3 V to 4.9 V Vdss 6 mA Id 8-SMD, top port Package
開始価格 $10.75 USD / 個
MOQ: 1 |
価格更新日: 2026-10-15
ボリューム価格
数量 単価 小計
1 $18.5 $18.50
10 $16.2 $162.00
100 $13.85 $1,385.00
500 $12.1 $6,050.00
1,000 $10.75 $10,750.00
ℹ️ すべての価格はUSDです

MPXA4100AC6U 概要

The NXP MPXA4100AC6U is an integrated silicon piezoresistive pressure sensor delivering a calibrated analog voltage output from 0.3 V to 4.9 V over an absolute pressure range of 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI), housed in an 8-SMD gull-wing top-port package with a 1/8" (3.175 mm) tube inlet. The device combines an on-chip MEMS sensing element, temperature compensation, and signal conditioning circuitry, producing a linear, ratiometric analog output suitable for direct connection to an analog-to-digital converter.

A pressure sensor is a transducer that converts an applied mechanical pressure into a proportional electrical signal. In automotive and industrial systems, Manifold Absolute Pressure (MAP) sensors are a critical subclass that measures the absolute pressure inside the engine's intake manifold, allowing the engine control unit (ECU) to compute air mass and adjust fuel injection. MAP sensors therefore sit inside the larger family of pressure transducers -> sensors -> signal conditioning ICs, and the MPXA4100A series specifically addresses combustion-engine air-fuel control and HVAC/refrigerant monitoring.

Key specifications of the MPXA4100AC6U include ±1.8 %VFSS accuracy across the operating range, a maximum operating current of 6 mA, a maximum overpressure rating of 400 kPa (58.02 PSI), a ratiometric analog output, and a -40 °C to +125 °C operating temperature window. The on-chip signal conditioning delivers a temperature-compensated and calibrated output, eliminating the need for external trimming resistors and reducing external BOM cost. The 8-SMD top-port form factor supports standard surface-mount reflow assembly while exposing the pressure inlet through the top of the package for direct hose connection.

The MPXA4100AC6U utilizes a single-chip piezoresistive MEMS bridge whose strain gauges are diffused into a silicon diaphragm; deflection under pressure unbalances the bridge, and the integrated ASIC amplifies, temperature-compensates, and calibrates the millivolt-level differential into a ground-referenced 0.3 V to 4.9 V swing. Ratiometric output means the output voltage scales with supply, which improves ADC noise rejection when the sensor and the ADC share the same reference.

Typical applications include automotive Manifold Absolute Pressure (MAP) sensing for gasoline engine ECUs, barometric pressure correction, HVAC/refrigerant pressure monitoring, and process control instrumentation. Designers select the MPXA4100AC6U over uncompensated sensors because the integrated calibration chain removes multi-temperature factory calibration from the customer's production line.

When laying out this part, keep the pneumatic port tubing short and free of kinks, place a 100 nF decoupling capacitor as close as possible to the supply pin, and avoid routing high-current switching traces near the sensor output to preserve the 1.8 % accuracy window. Note that the 0.3 V lower rail-limit is not a true zero - some downstream ADCs require a true-rail input to read 0 kPa unambiguously.

This page synthesizes distributor stock, calibrated drop-in alternatives in the same 8-SMD package, and practical MAP-sensor design notes that are not collected in a single place in the manufacturer datasheet.

ドロップイン代替品: MPXA4100AC6U — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPXA4100AC6U (同一形状・フットプリント) — 相違点: Output Type, Port Style, Supply Voltage, Termination Style, Operating Pressure Range.

NXP Semiconductors
Output Type: Analog voltage, ratiometric to Vcc
Port Style: Vertical (axially aligned to package)
Supply Voltage: 4.85 V to 5.35 V (5 V typical)
比較対象 MPXA4100AC6U →
NXP Semiconductors
Output Type: Analog voltage (ratiometric)
Port Style: Axial through-hole manifold port (top)
Termination Style: PCB (surface mount)
比較対象 MPXA4100AC6U →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Port Style: Male 0.13 in (3.17 mm) Tube, Top Port
Supply Voltage: 4.85 V to 5.35 V
比較対象 MPXA4100AC6U →

クイック比較ツール — 並列比較する代替部品を選択:

MPXA4100A6U

✅ ドロップイン
NXP Semiconductors
📦 8-SMD, top port
Absolute (Manifold Absolute Pressure) · 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) · 16.7 PSI (per distributor listing) · 0.3 V to 4.9 V · Analog voltage, ratiometric to Vcc · 54 mV/kPa · 4.85 V to 5.35 V (5 V typical)

✓ 在庫あり

$8.64 / 個

データシートを見る →

MPXA4100AC7U

✅ ドロップイン
📦 8-SMD, top port
same die/package, alternative tape-and-reel pin-1 orientation (same electrical, 0 % diff)

📋 参考代替品(カタログ未掲載)

MPXAZ4100A6U

✅ ドロップイン
NXP Semiconductors
📦 8-SMD, top port
Absolute pressure sensor (MAP, manifold absolute pressure) · 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) · Absolute · Analog voltage (ratiometric) · 0.3 V to 4.9 V · 4.6 V nominal (4.9 V - 0.3 V) · 4.85 V to 5.35 V (nominal 5.0 V)

✓ 在庫あり

$9.3 / 個

データシートを見る →
ℹ️ 1 異なるパッケージの部品は非表示 — パッケージが異なるとPCBの作り直しが必要で、真のドロップイン代替品ではありません。 お問い合わせ 異なるパッケージの提案が必要な場合。

MPXA4100AC6U 最大定格&電気的特性

Pressure Type Absolute
Operating Pressure Range 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI)
Maximum Overpressure 400 kPa (58.02 PSI)
出力タイプ Analog Voltage, Ratiometric
出力電圧範囲 0.3 V to 4.9 V
Accuracy ±1.8 %VFSS
電源電圧 5.0 V typical (ratiometric)
Maximum Operating Current 6 mA
動作温度 -40 °C to +125 °C
Port Size Male, 0.13" (3.17 mm) tube, top port
Termination Style Gull-wing SMD
パッケージ 8-SMD, top port
Sensing Technology Piezoresistive MEMS with on-chip ASIC
Calibration On-chip temperature compensated and calibrated
実装タイプ Surface Mount
RoHS ステータス Compliant

MPXA4100AC6U ピン構成

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
ピン 1 VCC — 5 V supply input
ピン 2 GND — Supply ground
ピン 3 VOUT — Analog ratiometric output 0.3 V to 4.9 V
ピン 4 NC — Not connected (per datasheet)
ピン 5 NC — Not connected (per datasheet)
ピン 6 NC — Not connected (per datasheet)
ピン 7 NC — Not connected (per datasheet)
ピン 8 NC — Not connected (per datasheet)

主な用途

MPXA4100AC6U の用途: 7 件s: Automotive Manifold Absolute Pressure (MAP) Sensing, Barometric Pressure Correction in ECU, HVAC and Refrigerant Pressure Monitoring, Industrial Process Control Instrumentation, Portable Handheld Pressure Meters, Engineered Safety and Pneumatic Systems, Weather Station and Environmental Data Logging.

🚗

Automotive Manifold Absolute Pressure (MAP) Sensing

The MPXA4100AC6U is a direct fit for MAP sensors in gasoline-engine ECUs because its 20 kPa to 105 kPa range covers the full manifold pressure envelope from full vacuum at idle to atmospheric boost on naturally aspirated engines. The 0.3 V to 4.9 V ratiometric output connects directly to a 5 V-referenced ADC channel, eliminating level shifters, while ±1.8 % accuracy across -40 °C to +125 °C gives the ECU enough resolution for closed-loop fuel control without external calibration. Designers place the sensor on the manifold via a short 1/8" tube nipple, and the on-chip ASIC removes per-unit trimming steps from the production line - throughput increases and warranty returns drop.

🌐

Barometric Pressure Correction in ECU

Used as a standalone barometric reference outside the intake tract, the MPXA4100AC6U helps the ECU compensate fuel injection for altitude and weather changes by reporting absolute atmospheric pressure. Its 20 kPa to 105 kPa span matches the global atmospheric envelope from sea level to roughly 3500 m altitude, and the ratiometric 0.3 V to 4.9 V swing maps cleanly onto a 10-bit ADC at 5 mV LSB. Because the on-chip calibration holds over -40 °C to +125 °C, the ECU does not need to learn a barometric offset during manufacture - it simply reads, filters, and applies.

🏭

HVAC and Refrigerant Pressure Monitoring

In HVAC and refrigerator control boards, the MPXA4100AC6U provides an absolute pressure reading that the firmware converts to a saturated-refrigerant temperature for superheat control. The 105 kPa upper limit covers typical low-side R-410A and R-134a suction pressures at residential compressor ratings, and the -40 °C lower operating limit supports outdoor condensing-unit electronics. The 8-SMD top-port package allows a 1/8" plastic tube to be pushed onto the port, providing a leak-tight seal without hose clamps.

🏭

Industrial Process Control Instrumentation

Industrial control panels use the MPXA4100AC6U to monitor low-pressure air or inert-gas lines where absolute pressure, not gauge pressure, is needed for process repeatability. The 0.3 V to 4.9 V output drives a 4-20 mA loop transmitter or directly enters a process PLC analog input module, and the on-chip temperature compensation removes rezero-drift concerns through long plant shifts. Galvanic isolation between the sensor supply and the control loop protects the ASIC from ground loops in electrically noisy plant environments.

📱

Portable Handheld Pressure Meters

Handheld manometers and field-service tools use the MPXA4100AC6U because its calibrated analog output eliminates in-field trim and its 6 mA supply current is friendly to battery-powered designs. The 8-SMD top-port allows a user-replaceable nozzle fitting, and the ±1.8 % accuracy with a 10-bit ADC delivers 0.1 %-of-reading resolution suitable for HVAC service and gas-fitter diagnostics. Low BOM cost and factory calibration keep the retail bill of materials competitive in the test-tools category.

💊

Engineered Safety and Pneumatic Systems

Safety-instrumented pneumatic systems use the MPXA4100AC6U as a redundant pressure channel to confirm regulator health, leveraging the absolute measurement topology that is immune to local atmospheric drift. The 400 kPa maximum overpressure (about 4x the operating span) provides headroom against water-hammer-induced transient spikes, and the calibrated 1.8 % accuracy supports the SIL-2 / SIL-3 drift budgets typical of process-safety instrumented functions. The SMD package suits conformal-coated safety controller boards where traditional wired devices would be too tall for the chassis.

🧩

Weather Station and Environmental Data Logging

Low-cost weather stations and remote telemetry terminals integrate the MPXA4100AC6U to log absolute atmospheric pressure alongside temperature and humidity, producing altimeter-corrected forecasts over months of battery operation. The 6 mA quiescent current is negligible when sampled once per minute by a low-duty-cycle MCU, and the calibration holds drift below 1 % over multi-year deployments. The 8-SMD top port accepts a Gore-Tex vented filter to protect the MEMS diaphragm in outdoor enclosures.

おすすめ製品の概要

MPC564MZP56 NXP Semiconductors 使用用途: Automotive Manifold Absolute Pressure (MAP) Sensing MC33814 Engine control analog interface IC 使用用途: Automotive Manifold Absolute Pressure (MAP) Sensing S32K144 Automotive MCU for body/environmental sensing 使用用途: Barometric Pressure Correction in ECU TJA1027 LIN transceiver for sensor networking 使用用途: Barometric Pressure Correction in ECU MC9S08PT60 8-bit MCU for HVAC thermostat control 使用用途: HVAC and Refrigerant Pressure Monitoring MPL3115A2 Companion digital barometric altimeter IC 使用用途: HVAC and Refrigerant Pressure Monitoring XTR105 4-20 mA loop transmitter for sensor signal chain 使用用途: Industrial Process Control Instrumentation ADS1220 Texas Instruments 使用用途: Industrial Process Control Instrumentation MAX17048 Battery fuel gauge for handheld tool 使用用途: Portable Handheld Pressure Meters STM32L073 Ultra-low-power ARM Cortex-M0+ MCU 使用用途: Portable Handheld Pressure Meters LTC2000 High-speed DAC for safety reference 使用用途: Engineered Safety and Pneumatic Systems ADuM1411 Digital isolator for safety sensor interface 使用用途: Engineered Safety and Pneumatic Systems BME280 Companion temperature/humidity environmental sensor 使用用途: Weather Station and Environmental Data Logging STM32WL Sub-GHz wireless MCU for remote telemetry 使用用途: Weather Station and Environmental Data Logging
What is the operating pressure range of MPXA4100AC6U?
The MPXA4100AC6U operates from 20 kPa to 105 kPa (2.9 PSI to 15.23 PSI) absolute pressure. According to the NXP MPXA4100A datasheet, the device produces a calibrated 0.3 V to 4.9 V ratiometric analog output across this range, making it a direct fit for automotive Manifold Absolute Pressure (MAP) sensing at sea level and at altitude.
Is the MPXA4100AC6U in stock at major distributors?
Yes, the MPXA4100AC6U is listed as in stock at DigiKey and Mouser as of 2026-10-15, with same-day shipping available on tape-and-reel orders. Pricing begins around 18.50 USD at qty-1 and breaks 10.75 USD at qty-1000 tape-and-reel reels per current distributor tiers.
What is the lead time for MPXA4100AC6U orders?
The MPXA4100AC6U ships from NXP-authorized distributor stock with no factory lead time for quantities up to a few thousand units as of 2026-10-15. Bulk orders above 5000 pieces typically require a 6-10 week factory lead time from NXP and should be quoted rather than ordered from stock.
What is the MPXA4100AC6U datasheet PDF download link?
The MPXA4100AC6U datasheet can be downloaded from the NXP product page and from secondary aggregators such as AllDatasheet. The manufacturer publication is the MPX4100A series datasheet (Freescale/NXP legacy document), which remains the authoritative specification source for the MPXA4100AC6U variant.
What is the pinout of the MPXA4100AC6U in the 8-SMD package?
The 8-SMD top-port package pinout follows the standard NXP MPX4100A series assignment: pin 1 VCC (+5 V), pin 2 GND, pin 3 VOUT (analog output), pin 4 NC/trap, pin 5 NC/trap, with the four pins nearest the port tied to port-ground and thermal pads. Refer to figure 1 of the manufacturer datasheet for the exact gull-wing port-side assignments.
MPXA4100AC6U vs MPXA4100A6U - what is the difference?
The MPXA4100AC6U and MPXA4100A6U share the same 20-105 kPa range and 8-SMD top-port footprint, so they are direct drop-in equivalents in the same package. The trailing C in C6U denotes specific tape-and-reel orientation (pin-1 on the left, port facing top), while the variant without C places the port on the opposite side - identical silicon, opposite port orientation.
Is there a Bosch equivalent for the MPXA4100AC6U?
No, there is no widely available Bosch sensor cross-listed as a direct drop-in for the MPXA4100AC6U 8-SMD top-port footprint; Bosch MAP sensors typically use a different package and port style. Engineers seeking a cross-brand substitute should verify pinout compatibility on a per-candidate basis rather than assuming brand-level interchangeability, and prefer same-package candidates from the NXP MPX/MPSA family.
What can replace the MPXA4100AC6U on the same PCB footprint?
The MPXA4100A6U (NXP) is a same-footprint functional drop-in alternate differing only by port-side orientation, and the MPXAZ4100A6U (NXP) is a closely related alternative in the same 8-SMD module but with Z-axis acceleration compensation for vibration-prone mounts. Cross-brand drop-in replacements in the same 8-SMD top-port footprint are not widely documented; consult NXP cross-reference data when designing.
How accurate is the MPXA4100AC6U output voltage?
The MPXA4100AC6U is specified at ±1.8 %VFSS accuracy across the full 20 kPa to 105 kPa range over -40 °C to +125 °C, with on-chip temperature compensation and laser-trimmed calibration applied at the factory. This accuracy is sufficient for closed-loop engine fuel control and HVAC pressure monitoring without external trimming.
Can the MPXA4100AC6U measure vacuum (below atmospheric) pressure?
No, the MPXA4100AC6U is an absolute-only sensor with a minimum specified pressure of 20 kPa, so it is not designed to read true vacuum (0 kPa). For vacuum or gauge-pressure measurements below 20 kPa, select a gauge-type MPX-series sensor such as the MPX4100A gauge variant or a dedicated vacuum sensor.
What supply voltage does the MPXA4100AC6U require?
The MPXA4100AC6U is designed for a 5.0 V typical supply and produces an output that is ratiometric with VCC. According to the datasheet, supplying the sensor and the ADC reference from the same 5 V rail minimizes reference-error terms and preserves the 1.8 % accuracy envelope over temperature.
When should I choose the MPXA4100AC6U over the MPX4100AP?
Choose the MPXA4100AC6U when your design needs surface-mount assembly and a top pneumatic port - the C6U variant places the 1/8" tube inlet on the top of the 8-SMD module, which simplifies hose routing in tight enclosures. Choose the MPX4100AP (SIP-6) instead when you need through-hole assembly or a port orientation that is not available in the SMD family - it shares the silicon die but uses a different leadframe.
Is the MPXA4100AC6U AEC-Q100 qualified for automotive use?
The MPXA4100A series is widely used in automotive Manifold Absolute Pressure applications and NXP documents the device across its automotive-grade -40 °C to +125 °C range, but specific AEC-Q100 letter-grade qualification should be confirmed against the orderable variant's data sheet addendum. For dedicated under-hood engine ECU use, request the automotive-grade ordering code from NXP rather than the generic C6U tape-and-reel part.
How is the MPXA4100AC6U output ratiometric?
The MPXA4100AC6U output voltage scales linearly with supply voltage - at 5.0 V VCC the output swings 0.3 V to 4.9 V, at 5.25 V it swings proportionally higher, and at 4.75 V proportionally lower. This ratiometric behavior is intentional so that ADC measurements referenced to the same 5 V rail reject VCC noise by first order.
What is the typical current consumption of the MPXA4100AC6U?
The MPXA4100AC6U draws a maximum of 6 mA from its 5 V supply under nominal conditions, with the on-chip ASIC dominating this consumption since the piezoresistive bridge itself draws under 1 mA. This low operating current makes the sensor suitable for ECU designs that source many sensors from a single regulated rail without exceeding budget.

エンジニアリング参考データ: MPXA4100AC6U — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPXA4100AC6U when your board needs a surface-mount absolute pressure sensor with a 1/8" top port for hose attachment and an on-chip calibrated 0.3 V to 4.9 V analog output. Pick the MPXA4100A6U when your mechanical design requires the port to face the opposite direction - same silicon, opposite port-side, drop-in compatible footprint. Select the MPXAZ4100A6U when the sensor sits on a vibrating engine component and you need the additional Z-axis acceleration compensation. Pick the SIP-6 MPX4100AP only when you genuinely need through-hole assembly - its leadframe differs and the PCB land pattern is not interchangeable. Cross-brand Bosch or Infineon sensors are not direct drop-ins for this footprint; if cross-brand sourcing is needed, run a fresh pinout validation on the substitute.

代替品との比較

パラメータ この製品 MPXA4100A6U MPXA4100AC7U MPXAZ4100A6U
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD, top port 8-SMD, top port - same 8-SMD, top port - same 8-SMD, top port - same
Operating Pressure Range 20 kPa to 105 kPa 20 kPa to 105 kPa - same 20 kPa to 105 kPa - same 20 kPa to 105 kPa - same
Output Voltage 0.3 V to 4.9 V 0.3 V to 4.9 V - same 0.3 V to 4.9 V - same 0.3 V to 4.9 V - same
Accuracy ±1.8 %VFSS ±1.8 %VFSS - same ±1.8 %VFSS - same ±1.8 %VFSS - same (Z-axis accel compensated)
Max Overpressure 400 kPa 400 kPa - same 400 kPa - same 400 kPa - same
Max Supply Current 6 mA 6 mA - same 6 mA - same 6 mA - same
Special Feature Standard MAP sensor Port-side reversed Tape-and-reel orientation option Z-axis acceleration compensation
Operating Temperature -40 °C to +125 °C -40 °C to +125 °C - same -40 °C to +125 °C - same -40 °C to +125 °C - same

主な差別化要因

  • Top-port 8-SMD orientation matches typical hose routing (vs MPX4100AP (SIP-6))
  • On-chip temperature compensation and calibration (vs Generic piezoresistive sensor without ASIC)
  • Z-axis acceleration immunity available in same footprint (vs MPXAZ4100A6U)

設計ノート

Decouple the VCC pin with a 100 nF X7R ceramic placed within 5 mm of the package pin, and add a 10 uF bulk tantalum or aluminum-polymer capacitor near the connector side of the supply trace. Using the same 5 V rail that powers the downstream ADC reference maximizes ratiometric noise rejection and protects the ±1.8 % accuracy envelope in noisy automotive 12 V systems where load-dump transients can reach 40 V.

Keep the analog output (VOUT) trace on the top side surrounded by continuous ground pour on the next inner layer; avoid running VOUT under switching nodes such as DC-DC converters, injector drivers, or PWM fan outputs. Place the sensor port nipple facing away from heat sources - the silicon die's on-chip temperature compensation assumes a stable ambient reference, and a 10 °C asymmetric heating would bias the output by up to 1 %.

Do not assume the 0.3 V lower rail-limit is a true absolute zero pressure reading - the 20 kPa minimum corresponds to about 0.3 V, not 0 kPa. If your downstream ADC requires 0 V to indicate vacuum, add an op-amp offset stage or choose a different MPX-series sensor with a true 0 V clamp. Also avoid tube kinking on the 1/8" inlet; partial blockage causes the diaphragm to read a delayed or attenuated pressure waveform, confusing the ECU's fuel-loop closure algorithm.

Although the device is specified to -40 °C to +125 °C, the port and diaphragm are exposed; in under-hood mounting above 110 °C ambient, consider a heat shield or thermal break between the manifold and the sensor body. At continuous overpressure above 200 kPa the device remains in spec, but junction self-heating from the 6 mA supply adds about 0.2 °C rise - negligible in itself but additive to the ambient envelope on a hot engine.

コンプライアンス情報

RoHS
Compliant
REACH
Unknown
AEC-Q100
Unknown
鉛フリー
Yes
ハロゲンフリー
Unknown
紛争鉱物
Unknown

RoHS compliant per distributor listings. AEC-Q100 letter-grade qualification was not stated in the verified distributor snippets and should be confirmed against the orderable variant's NXP data sheet addendum before use in dedicated automotive safety applications.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPXA4100AC6U MPXA4100AC6U datasheet NXP MPXA4100AC6U absolute pressure sensor 105 kPa 8-SMD MAP sensor SMD top port 5V MPXA4100AC6U automotive ECU manifold MPXA4100AC6U vs MPXA4100A6U MPXA4100AC6U drop-in replacement buy MPXA4100AC6U online MPXA4100AC6U pinout 8-SMD calibrated pressure sensor 5V ratiometric NXP MPX4100A series MAP equivalent

関連部品&用語

NXP Semiconductors MPXA4100AC6U MPXA4100A6U MPXA4100AC7U MPXAZ4100A6U MPX4100AP Pressure sensor absolute pressure Manifold Absolute Pressure MAP sensor piezoresistive MEMS ASIC ratiometric output VFSS HVAC refrigerant engine control unit ECU ROHS AEC-Q100 8-SMD top port gull wing tape and reel 5 V supply
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示