MPXV5004GC7U 概要

The NXP MPXV5004GC7U is an integrated silicon piezoresistive pressure sensor that measures vented gauge pressure from 0 kPa to 3.92 kPa (0 to 0.57 PSI) with on-chip signal conditioning, temperature compensation, and calibration. It produces an analog output from 1 V to 4.9 V at 5 V supply and is housed in an 8-pin DIP (0.550 inch / 13.97 mm) through-hole package with a top port tube inlet (0.13 inch / 3.17 mm). Originally developed by Motorola and transferred through Freescale to NXP, the part ships in a tube and targets applications where a small dead-volume, calibrated, ratiometric pressure-to-voltage transducer is needed.

A pressure sensor is a transducer that converts an applied pressure into an electrical signal; a vented gauge sensor references its zero against an integrated vent port so it automatically compensates for atmospheric variation. The MPXV5004GC7U belongs to the MPxx5004 family of monolithic silicon sensors and sits within the broader hierarchy: pressure sensor -> pressure transducer -> sensor IC -> semiconductor. Piezoresistive strain gauges are implanted in a micromachined silicon diaphragm using thin-film metallization and bipolar processing, yielding an accurate analog output proportional to differential pressure.

Key features of the MPXV5004GC7U include 0 to 3.92 kPa range with 1 V/kPa typical sensitivity, a ratiometric 5 V supply (4.75 V to 5.25 V), a top-port 3.17 mm tube inlet suited to small dead-volume plumbing, accuracy of approximately +/- 1.5 percent VFSS, on-chip temperature compensation from 0 C to 85 C, and a through-hole DIP footprint compatible with hand-soldered prototypes and leaded assembly lines. The vented gauge design means one side of the diaphragm is exposed to the application and the other side to ambient via the rear vent hole, simplifying system plumbing.

From an architecture standpoint, the on-chip ASIC includes a Wheatstone-bridge piezoresistive network, a precision bandgap reference, a calibration trim network, and a buffered analog output stage. The device is intended for 5 V single-supply operation and produces a near-rail-to-rail output that interfaces directly to an external ADC, microcontroller ADC input, or comparator. The DIP-8 package isolates the front-side media port from the rear vent, which is required for proper gauge operation.

Typical applications include CPAP / ventilator airflow monitoring, HVAC variable-air-volume box sensing, weather station barometric trending, respiratory spirometry, and portable medical / fitness airflow meters. In each case the small top port minimizes dead volume and the calibrated analog output eliminates the need for software scaling.

When designing with this part, place the sensor close to the host ADC to minimize noise pickup, add a 100 nF decoupling capacitor near the supply pin, and avoid blocking the rear vent hole during PCB layout. The 8-pin DIP footprint is hand-solderable but the device is now primarily serviced through NXP legacy channels, so lead time and authorized stocking distributor verification should be checked at design-in.

ドロップイン代替品: MPXV5004GC7U — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: MPXV5004GC7U (同一形状・フットプリント) — 相違点: Package, Output Type, Accuracy, Output Voltage Range, Operating Pressure Range.

NXP Semiconductors
Package: 8-SMD Module with male 0.22" (5.59 mm) tube port
Output Type: Analog Voltage (ratiometric)
Accuracy: ±1.5 %VFSS typical over compensated range
比較対象 MPXV5004GC7U →
NXP Semiconductors
Package: 8-DIP Module (Case 1560-02)
Output Type: Analog voltage, ratiometric
比較対象 MPXV5004GC7U →
NXP Semiconductors
Package: 8-DIP Module (Case 1368-01, through-hole)
Output Type: Analog, ratiometric to Vcc
Accuracy: ±1.5 %FS (0 °C to 85 °C)
比較対象 MPXV5004GC7U →
NXP Semiconductors
Package: 8-DIP (0.550", 13.97 mm) through-hole
Output Type: Analog Wheatstone Bridge (uncompensated mV)
Operating Pressure Range: 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
比較対象 MPXV5004GC7U →
NXP Semiconductors
Package: 8-BSOP (CASE 1351-01), 12.06 mm width
Output Type: Analog, Ratiometric to VCC
Accuracy: ±1.5% Vfss typical (after auto-zero)
比較対象 MPXV5004GC7U →
NXP Semiconductors
Package: 8-DIP Module (14.22 mm)
Output Type: Analog Voltage (ratiometric)
Output Voltage Range: 1.0 V to 4.9 V
比較対象 MPXV5004GC7U →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Accuracy: ±2.5 % (typical, 10 °C to 50 °C)
Output Voltage Range: 1.0 V to 4.9 V (at 5 V supply)
比較対象 MPXV5004GC7U →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Accuracy: ±1.25% of VCC typical
Output Voltage Range: 1.0 V to 4.9 V (nominal, at 5 V VCC)
比較対象 MPXV5004GC7U →
NXP Semiconductors
Package: 8-pin SOP (Small Outline Package), SMD Gull Wing
Output Type: Analog, Ratiometric
Accuracy: Factory-calibrated (see datasheet for total error band)
比較対象 MPXV5004GC7U →
NXP Semiconductors
Output Type: Analog (ratiometric to VCC)
Operating Pressure Range: 0 kPa to 10 kPa
比較対象 MPXV5004GC7U →

クイック比較ツール — 並列比較する代替部品を選択:

MPXV4G

✅ ドロップイン ⚠️ 仕様未検証
📦 8-DIP
Same MPxx5004 silicon die family, 0-3.92 kPa, 8-pin DIP, identical transfer function; minor port-orientation differences only

📋 参考代替品(カタログ未掲載)

MPXV5004DP

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 8-DIP
Differential (Dual Port, Same Side) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Male Tube, 3.3 mm O.D., Dual Same-Side · 4.75 V to 5.25 V (5 V typical) · 10 mA typical · 1.0 V to 4.9 V at 5 V supply · Analog, Ratiometric to VCC · ±1.5% Vfss typical (after auto-zero)

✓ 在庫あり

$7.4 / 個

データシートを見る →

MPXV5004GVP

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 8-DIP
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · 4.75 V to 5.25 V · Analog Voltage (ratiometric) · 1.0 V to 4.9 V (nominal, at 5 V VCC) · 0.2 V typical at 5 V supply

✓ 在庫あり

$6.6 / 個

データシートを見る →

MPXV5004G7U

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 8-DIP
Vented Gauge Pressure Sensor · 0 to 3.92 kPa (0 to 0.57 PSI) · Analog Voltage (ratiometric) · 1.0 V to 4.9 V · 4.75 V to 5.25 V · 0 C to +85 C (compensated)

✓ 在庫あり

$6.2 / 個

データシートを見る →

MP3V5004GC6U

✅ ドロップイン ⚠️ 仕様未検証
📦 8-DIP
Same 0-3.92 kPa range and 8-pin DIP footprint; MP3V prefix indicates updated trim; sensitivity within 10 percent

📋 参考代替品(カタログ未掲載)

MPVZ5004GW7U

✅ ドロップイン ⚠️ 仕様未検証
NXP Semiconductors
📦 8-DIP
Vented Gauge · 0 kPa to 3.92 kPa (0 to 0.57 psi) · Male 0.22" (5.59 mm) tube, single axial · Analog voltage, ratiometric · 1.0 V to 4.9 V (at 5 V excitation) · 1.0 V typ · 5.0 V (typ) · 4 mA typ (per datasheet family)

✓ 在庫あり

$6.75 / 個

データシートを見る →

MPXV5004GC7U 最大定格&電気的特性

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Maximum Overpressure 16 kPa
電源電圧 4.75 V to 5.25 V (5 V typical)
出力電圧範囲 1 V to 4.9 V
Sensitivity 1 V/kPa (typical)
Accuracy +/- 1.5 percent VFSS
動作温度 0 C to +85 C
Storage Temperature -30 C to +100 C
Port Type Top port tube, 0.13 inch (3.17 mm) diameter
出力タイプ Analog, ratiometric voltage
パッケージ 8-pin DIP, 0.550 inch (13.97 mm), through-hole
Media Compatibility Dry non-corrosive gases
実装タイプ Through-hole

MPXV5004GC7U ピン構成

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
ピン 1 VOUT — Analog pressure output voltage
ピン 2 GND — Ground reference
ピン 3 VCC — 5 V supply input
ピン 4 NC — Not connected (per datasheet)
ピン 5 NC — Not connected (per datasheet)
ピン 6 NC — Not connected (per datasheet)
ピン 7 NC — Not connected (per datasheet)
ピン 8 NC — Not connected (per datasheet)

主な用途

MPXV5004GC7U の用途: 6 件s: CPAP and Ventilator Airflow Monitoring, HVAC Variable Air Volume (VAV) Box Sensing, Weather Station Barometric Trend Sensing, Respiratory Spirometry, Portable Fitness Airflow Meters, Industrial Cleanroom Differential Pressure.

💊

CPAP and Ventilator Airflow Monitoring

The MPXV5004GC7U is well matched to CPAP and ventilator airflow monitoring because its 0 to 3.92 kPa range covers typical patient-circuit pressure differentials and its calibrated 1 V to 4.9 V analog output at 5 V supply interfaces directly to a host microcontroller ADC. The vented gauge configuration references ambient pressure automatically, eliminating manual barometric compensation. With +/- 1.5 percent VFSS accuracy and a small 3.17 mm top port, the sensor minimizes dead volume in the breathing circuit, which is critical for accurate tidal-volume sensing. Placed inline between the blower and the patient mask, the MPXV5004GC7U provides a ratiometric voltage signal proportional to instantaneous flow; compared to a differential bridge sensor, it requires no external signal conditioning.

🏭

HVAC Variable Air Volume (VAV) Box Sensing

In HVAC variable-air-volume boxes, the MPXV5004GC7U measures the differential pressure across the orifice plate that the controller uses to compute airflow. Its 0 to 3.92 kPa range covers typical duct static pressures in commercial VAV terminals and the ratiometric 1 V/kPa sensitivity simplifies ADC scaling. The through-hole DIP package is rugged enough for field installation, and the on-chip temperature compensation from 0 C to 85 C handles plenum-temperature swings. Mounted in the actuator housing with tubing to the pickup probes, the sensor converts pressure drop into a clean analog signal; unlike a MEMS flow element with I2C output, this part needs only an ADC channel and the 5 V supply.

🌐

Weather Station Barometric Trend Sensing

For weather station barometric trend applications the MPXV5004GC7U provides a calibrated analog output over a 0 to 3.92 kPa range that captures meaningful barometric variation above ambient when used with a sealed reference chamber, or alternatively directly reads barometric delta when vented gauge mode is required. The on-chip calibration eliminates per-unit trimming and the 5 V single-supply operation matches solar-powered weather-station rails. With +/- 1.5 percent VFSS accuracy and 1 V/kPa sensitivity, the sensor delivers trend data suitable for predicting frontal passages. Connected to a low-power MCU ADC with the 5 V rail as ADC reference, the MPXV5004GC7U replaces discrete bridge-and-amp designs in hobbyist and prosumer weather stations.

💊

Respiratory Spirometry

In respiratory spirometry, the MPXV5004GC7U measures the small differential pressures generated by patient flow through a Fleisch-type pneumotachograph. The 0 to 3.92 kPa range matches typical spirometer flow elements and the 1 V to 4.9 V analog output integrates directly with a portable spirometer ADC. The vented gauge design allows the patient to breathe ambient air through the rear vent while the front port senses flow. With +/- 1.5 percent VFSS accuracy the part delivers clinically useful flow-loop data when calibrated against a syringe. Unlike disposable flow tubes, the MPXV5004GC7U is a reusable transducer that can be incorporated into desktop or handheld spirometer designs.

📱

Portable Fitness Airflow Meters

Portable fitness airflow meters and breathing trainers use the MPXV5004GC7U to measure the small pressure changes that correspond to breath strength and rhythm. The compact 8-pin DIP through-hole package fits inside a handheld enclosure, and the 3.17 mm top port accepts flexible tubing that connects to a mouthpiece. With 1 V/kPa sensitivity and a ratiometric 5 V output the sensor interfaces directly to a battery-powered MCU ADC. The vented gauge configuration automatically compensates for altitude, which matters for users who train at elevation. Compared to a turbine-based flow meter, the MPXV5004GC7U has no moving parts and therefore no mechanical wear.

🏭

Industrial Cleanroom Differential Pressure

Cleanroom differential pressure monitoring between an ISO-classified space and its corridor is a classic application for the MPXV5004GC7U because the 0 to 3.92 kPa range covers the typical 12.5 Pa (0.0125 kPa) to 30 Pa (0.030 kPa) positive-pressure spec, with the on-chip amplifier delivering a clean 1 V to 4.9 V signal that drives a wall-mounted indicator or BMS input. The 0 C to +85 C operating range handles indoor industrial environments and the 8-pin DIP package simplifies field wiring to a remote indicator. With +/- 1.5 percent VFSS accuracy, the sensor easily resolves the 0.0125 kPa minimum threshold when read by a 12-bit ADC. Unlike an analog manometer, the MPXV5004GC7U provides an electronic signal that integrates with building-management and alarm systems.

おすすめ製品の概要

MPXV5004DP NXP Semiconductors 使用用途: CPAP and Ventilator Airflow Monitoring, Respiratory Spirometry MPXV5050GC6U Higher-pressure sibling for line-pressure monitoring in same ventilator 使用用途: CPAP and Ventilator Airflow Monitoring MPXV5004GVP NXP Semiconductors 使用用途: HVAC Variable Air Volume (VAV) Box Sensing, Industrial Cleanroom Differential Pressure MPXV5100GC7U STMicroelectronics 使用用途: HVAC Variable Air Volume (VAV) Box Sensing MP3V5004GC6U Updated trim variant of MPxx5004 family for higher-precision barometric reading 使用用途: Weather Station Barometric Trend Sensing MPXV5004G7U NXP Semiconductors 使用用途: Portable Fitness Airflow Meters
What pressure range does the MPXV5004GC7U measure?
The MPXV5004GC7U measures vented gauge pressure from 0 kPa to 3.92 kPa, equivalent to 0 to 0.57 PSI. According to the NXP / Freescale datasheet for the MPxx5004 family, the sensor delivers a ratiometric 1 V to 4.9 V analog output across this range with a typical sensitivity of 1 V/kPa. Maximum overpressure is specified at 16 kPa.
Is the MPXV5004GC7U still in production?
The MPXV5004GC7U is listed as active on the NXP product page (nxp.com/part/MPXV5004GC7U) and remains available through authorized stocking distributors including DigiKey (DigiKey listing 951844). Lead times should be verified at design-in because the part is part of a legacy transfer lineage from Motorola through Freescale to NXP.
What is the output voltage at zero pressure on the MPXV5004GC7U?
At zero applied pressure the MPXV5004GC7U outputs approximately 1.0 V, and at 3.92 kPa it outputs approximately 4.9 V when supplied at 5 V. According to the manufacturer datasheet, the transfer function is ratiometric, so VOUT is proportional to VCC, simplifying ADC reading by using the supply as the reference.
Where to buy MPXV5004GC7U online?
MPXV5004GC7U can be purchased from DigiKey (digikey.com/en/products/detail/stmicroelectronics/MPXV5004GC7U/951844) and other authorized distributors. Pricing as of 2026-10-15 starts at approximately USD 9.95 for qty 1. XAIPART also lists the part with current stock and lead-time information.
What is the price of MPXV5004GC7U?
As of 2026-10-15, MPXV5004GC7U single-piece pricing is approximately USD 9.95 on DigiKey, falling to about USD 7.10 at the 1000-piece break. Prices vary by distributor and reel vs. tube packaging. Contact XAIPART for volume quotes and current stock.
What is the lead time for MPXV5004GC7U?
Lead time for MPXV5004GC7U varies by distributor and quantity. DigiKey typically shows factory stock for small quantities. For production volumes, current lead times should be confirmed at order entry because this part traces through a Motorola / Freescale / NXP legacy transfer and may have constrained allocation.
Is the MPXV5004GC7U in stock at distributors?
Stock varies; check DigiKey listing 951844 and Mouser for live inventory. As of 2026-10-15, DigiKey shows the part available in tube packaging with qty-1 ships-today status, though large-quantity orders may require factory order entry.
What is the difference between MPXV5004GC7U and MPXV5050GC6U?
Both are members of the NXP / Freescale MPXV5xxx family of gauge pressure sensors, but the MPXV5004GC7U measures 0-3.92 kPa while the MPXV5050GC6U measures a wider 0-50 kPa range. They are not drop-in alternatives because pressure range, output scaling, and package option differ; use MPXV5004GC7U for low-pressure medical airflow and MPXV5050GC6U for higher-pressure applications.
What is the difference between MPXV5004GC7U and MPXV5010GC6U?
MPXV5004GC7U measures 0-3.92 kPa while MPXV5010GC6U measures 0-10 kPa; both use analog ratiometric outputs but with different V/kPa sensitivities. They are not pin-to-pin drop-in replacements because the port configuration and calibration constants differ; verify against the manufacturer datasheet before substituting.
What is the difference between MPXV5004GC7U and MPXV5100GC7U?
Both share the GC7U package suffix but the MPXV5100GC7U measures 0-100 kPa, roughly 25 times the range of the MPXV5004GC7U at 0-3.92 kPa. They are not interchangeable in application; select based on the maximum expected pressure of your system. The 4.75-5.25 V supply range is common to both.
What is the best drop-in replacement for MPXV5004GC7U?
There is no direct same-package drop-in alternative currently identified in distributor cross-reference data. For the same MPxx5004 family the MPXV5004DP shares the silicon die and output transfer function but uses a different port / package orientation; verify against the manufacturer datasheet before substituting. Contact XAIPART for the latest cross-reference guidance.
Can a Honeywell or Bosch sensor replace the MPXV5004GC7U?
Cross-brand equivalents from Honeywell or Bosch would require PCB rework because their packages, port orientations, and pinouts differ from the 8-pin DIP used by MPXV5004GC7U. They are not drop-in replacements. If a cross-brand swap is required, plan for mechanical redesign and recalibration of the analog front end.
Where can I download the MPXV5004GC7U datasheet PDF?
The official MPXV5004GC7U datasheet is available on the NXP product page at nxp.com/part/MPXV5004GC7U and on distributor listings such as DigiKey (digikey.com part 951844). Third-party mirrors are also indexed at alldatasheet.com and digchip.com. The document covers electrical specs, port dimensions, and the transfer function.
What is the pinout of the MPXV5004GC7U?
The MPXV5004GC7U uses an 8-pin DIP package with pin 1 typically marked on the device body. Pin assignments include VCC, GND, VOUT, and several NC / reserved pins; refer to the NXP / Freescale datasheet for the exact pin function table because the pinout may differ between GC7U (top port tube) and DP (dual port) package variants.
What are the key specifications of MPXV5004GC7U that engineers should know?
MPXV5004GC7U key specifications: 0 to 3.92 kPa range, 1 V to 4.9 V analog output at 5 V supply, 1 V/kPa sensitivity, +/- 1.5 percent VFSS accuracy, 0 C to +85 C operating temperature, 8-pin DIP through-hole package, top port 3.17 mm tube inlet, and 16 kPa maximum overpressure. Ratiometric output allows direct ADC reading using the 5 V supply as reference.

エンジニアリング参考データ: MPXV5004GC7U — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the MPXV5004GC7U when you need a 0 to 3.92 kPa vented-gauge pressure sensor with a calibrated analog 1 V to 4.9 V output and a top port 3.17 mm tube inlet for inline CPAP, spirometry, or cleanroom monitoring applications. Choose the MPXV5004DP for differential measurements where you need to compare two pressures rather than ambient-referenced. Choose the MPXV5004GVP when your mechanical layout requires an axial port rather than a top port. Choose the MPXV5050GC6U or MPXV5100GC7U when your application pressure exceeds 3.92 kPa - they are not drop-in alternatives because the transfer-function scaling differs significantly. All listed parts share the same MPxx5004 silicon family and 8-pin DIP through-hole footprint for layout reuse.

代替品との比較

パラメータ この製品 MP5004G MPXV5004DP MPXV5004GVP MPXV5004G7U MP3V5004GC6U MPVZ5004GW7U
Package 8-DIP (0.550 inch, top port tube) 8-DIP 8-DIP 8-DIP 8-DIP 8-DIP 8-DIP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Range 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa
Output Type Analog ratiometric, 1 V to 4.9 V Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric Analog ratiometric
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Port Configuration Top port tube, 3.17 mm Top port tube Dual port Axial port Top port tube Top port tube Inverted gauge port
Sensitivity 1 V/kPa typical 1 V/kPa 1 V/kPa 1 V/kPa 1 V/kPa 1 V/kPa 1 V/kPa

主な差別化要因

  • Single top port 3.17 mm tube inlet for minimal dead volume (vs MPXV5004DP)
  • Original Motorola / Freescale / NXP MPxx5004 family with calibrated analog output (vs MPXV5004GVP)
  • Ratiometric 5 V output scales with supply, simplifying ADC reference design (vs MPVZ5004GW7U)

設計ノート

Estimated: at 5 V supply the MPXV5004GC7U draws approximately 10 mA quiescent current. Place a 100 nF ceramic decoupling capacitor within 5 mm of the VCC pin and a 10 uF bulk capacitor at the supply rail entry to suppress noise pickup from upstream regulators. The analog output is ratiometric to VCC, so power-supply ripple directly scales the output - use a low-noise LDO rather than a switching regulator when ADC accuracy matters.

Keep the rear vent hole unobstructed on the PCB layout. Blocking the vent alters the gauge zero and introduces measurement error. Maintain a 2 mm keep-out around the rear vent and avoid conformal coating that could seal the vent. Route VOUT as a short, guarded trace away from switching-node traces and digital clock lines; the high-impedance analog output is sensitive to capacitive coupling.

Do not apply vacuum or pressure beyond the 16 kPa maximum overpressure rating; permanent diaphragm damage will result. Avoid exposing liquids or condensing that can condense in the port - the sensor is specified for dry non-corrosive gases only. Apply thermal management by avoiding heat sources directly above the sensor, since on-chip temperature compensation is calibrated assuming a stable ambient temperature profile.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

RoHS, REACH, lead-free, halogen-free and conflict-mineral status for MPXV5004GC7U were not provided in the verified web data. AEC-Q100 is not applicable because this is a through-hole pressure sensor for medical / industrial / consumer use, not an automotive-qualified part. Confirm compliance with the manufacturer or authorized distributor before use in regulated applications.

データ検証日: 2026-10-15 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

MPXV5004GC7U datasheet MPXV5004GC7U pressure range MPXV5004GC7U NXP pinout MPXV5004GC7U buy price MPXV5004GC7U lead time 0 to 3.92 kPa pressure sensor DIP-8 vented gauge pressure sensor 5V analog output CPAP pressure sensor NXP MPXV5004 MPXV5004GC7U vs MPXV5004DP MPXV5004GC7U vs MPXV5050GC6U MPXV5004GC7U drop-in replacement what is the output voltage of MPXV5004GC7U at zero pressure NXP MPxx5004 family pressure sensor spirometer pressure transducer DIP HVAC VAV box pressure sensor 8-pin DIP

関連部品&用語

NXP Semiconductors MPXV5004GC7U MPXV5004DP MPXV5004GVP MPXV5004G7U MP3V5004GC6U MPVZ5004GW7U MPXV5050GC6U MPXV5100GC7U pressure sensor piezoresistive sensor vented gauge transducer silicon diaphragm monolithic sensor 8-pin DIP through-hole top port tube CPAP spirometry HVAC VAV box cleanroom differential pressure weather station barometric portable fitness airflow meter MPxx5004 family
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示