OPA277UA - 36V Precision Op Amp, 10uV Offset | Texas Instruments
部品番号: OPA277UA ✓ 生産中OPA277UA 概要
An operational amplifier is a high-gain differential amplifier whose output responds to the voltage difference between its non-inverting and inverting inputs. Precision op amps belong to the amplifier IC category and can be divided into general-purpose, precision, and high-speed families. The OPA277UA sits in the precision family: its low offset and drift preserve measurement accuracy over time and temperature, while its high rejection ratios reduce errors caused by supply variation and signals common to both inputs.
According to the manufacturer datasheet, the OPAx277 series replaces the industry-standard OP-177 while offering improved noise, a wider output voltage swing, twice the speed, and half the quiescent current of that reference device. The series also specifies low bias current, high common-mode rejection, and high power-supply rejection. These characteristics make the amplifier useful when sensor outputs are small, when calibration accuracy must survive temperature changes, or when supply ripple could otherwise modulate the measurement.
OPA277UA operates from dual supplies of ±2 V to ±18 V, allowing it to work with ±5 V, ±12 V, and ±15 V laboratory rails. Its wide input capability supports conventional bipolar analog systems, and the 8-pin SOIC package simplifies assembly where a compact, surface-mount precision amplifier is required. The manufacturer identifies the device as a general-purpose amplifier with a single-ended output.
Typical uses include precision bridge and transducer amplifiers, laboratory instrument front ends, low-level sensor conditioning, current measurement, and high-resolution data-conversion systems. The device can also buffer slow, high-impedance sources where offset drift and bias-current error would otherwise dominate the signal chain.
When designing around the OPA277UA, verify input and output voltage limits at the selected supply voltage and keep the input common-mode range within the operating envelope. Use short, guarded signal traces and maintain stable feedback layouts because a precision amplifier preserves small signals rather than correcting poor board-level noise pickup.
This page combines manufacturer specifications, package information, drop-in replacement analysis, comparison parameters, and practical design guidance for engineers evaluating the OPA277UA.
ドロップイン代替品: OPA277UA — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: OPA277UA (同一形状・フットプリント) — 相違点: Amplifier Type, Package, Supply Voltage Range, Slew Rate, Operating Temperature Range.
OPA277U
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →OPA277UG4
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
OPA27GU
✅ ドロップイン価格はお問い合わせください
データシートを見る →OPA2277UA
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD8627ARZ
✅ ドロップイン価格はお問い合わせください
データシートを見る →OPA277UA 最大定格&電気的特性
| Amplifier Type | Single-channel precision operational amplifier |
| トポロジー | Single-ended output |
| Architecture | Bipolar |
| Supply Voltage Range | ±2 V to ±18 V |
| Maximum Supply Voltage | 36 V |
| Input Offset Voltage | 10 uV maximum |
| Input Offset Voltage Drift | 0.1 uV/°C maximum |
| Noise Performance | Improved relative to the OP-177 reference device |
| パッケージ | 8-pin SOIC |
| 実装タイプ | Surface mount |
OPA277UA ピン構成
| ピン 1 | NC — Not connected |
| ピン 2 | -IN — Inverting input |
| ピン 3 | +IN — Non-inverting input |
| ピン 4 | V- — Negative supply connection |
| ピン 5 | NC — Not connected |
| ピン 6 | OUT — Analog output |
| ピン 7 | V+ — Positive supply connection |
| ピン 8 | NC — Not connected |
主な用途
OPA277UA の用途: 6 件s: Precision Bridge and Transducer Amplification, Laboratory Instrument Front End, High-Resolution Data Acquisition, Precision Current Measurement, Low-Level Sensor Buffering, Precision Audio and Reference Signal Paths.
Precision Bridge and Transducer Amplification
The OPA277UA fits low-level bridge measurements because its 10 uV maximum input offset voltage and 0.1 uV/°C maximum offset drift reduce errors that would otherwise be amplified by high gain. Place the amplifier where the bridge return path is short and shielded so that thermal gradients and leakage currents do not add more error than the device itself. Its high common-mode rejection and high power-supply rejection also help when the sensor is powered from a rail that carries switching ripple. Resistor-network matching remains important because amplifier specifications alone cannot correct imbalance in the bridge or feedback network.
おすすめ
Laboratory Instrument Front End
Use the OPA277UA when a laboratory or test instrument must amplify a small differential signal without adding significant offset drift. Its 36 V maximum supply capability supports ±15 V analog rails, while the ±2 V to ±18 V operating range also permits lower-voltage laboratory systems. The precision architecture is valuable in buffer, difference, and feedback configurations where calibration stability affects traceability. Keep high-impedance input traces short, guard the inverting input when leakage is significant, and follow the manufacturer guidance for compensation and output-load stability.
おすすめ
High-Resolution Data Acquisition
The OPA277UA is suitable for conditioning a sensor signal ahead of a high-resolution converter when offset and temperature drift dominate the measurement error. Its 10 uV maximum offset and 0.1 uV/°C maximum drift preserve millivolt-level information more effectively than a general-purpose amplifier, while high common-mode rejection limits disturbance from signals common to both inputs. Place the amplifier close to the converter input to minimize pickup between the analog output and the sampling circuit, and verify that the selected converter input range is compatible with the amplifier output swing.
おすすめ
Precision Current Measurement
The OPA277UA can amplify the output of a shunt or current transducer where the measured signal is small and accuracy must be retained over temperature. Its 10 uV maximum offset and 0.1 uV/°C maximum drift limit amplifier-generated errors, and its high power-supply rejection helps isolate the measurement from supply variations. A dedicated current-sense amplifier may integrate the shunt amplifier and reference more efficiently, so use the OPA277UA when flexibility, bipolar signal handling, or standalone precision amplification is more important than integration.
おすすめ
Low-Level Sensor Buffering
The OPA277UA works well as a buffer for high-impedance sensors where bias current, offset, and drift can dominate the available signal. Low bias current is specifically identified among the OPAx277 family characteristics, while the 10 uV maximum offset supports accurate output scaling into a downstream converter or measurement block. Keep the input node physically small, avoid long unshielded traces, and prevent conductive contamination on the board because surface leakage can exceed the amplifier's input current and destroy the benefit of a high-impedance design.
おすすめ
Precision Audio and Reference Signal Paths
The OPA277UA can serve as a low-level audio buffer or reference-signal amplifier when channel matching, offset stability, and low-level noise are more important than wideband audio bandwidth. The manufacturer describes the OPAx277 family as offering improved noise relative to the OP-177 reference device, while the 10 uV maximum offset and 0.1 uV/°C maximum drift help maintain channel-to-channel consistency. Confirm the amplifier's gain-bandwidth and output-drive requirements for the selected audio path, and place it where the return currents from digital and power-conversion circuitry cannot enter the signal ground.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: OPA277UA — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | OPA277U | OPA277UG4 | OPA27GU | OPA2277UA | AD8627ARZ |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices | Analog Devices |
| Package | 8-pin SOIC | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint | 8-pin SOIC - same footprint |
| Amplifier Configuration | Single amplifier | Single amplifier | Single amplifier | Single amplifier | Single amplifier | Single amplifier |
主な差別化要因
- Low offset and drift for precision measurement (vs OPA27GU)
- Modern family performance relative to the OP-177 reference (vs OPA27GU)
- Broad bipolar supply operating range (vs OPA2277UA)
- Same-brand ordering continuity (vs OPA2277UA)
設計ノート
Do not treat the 36 V maximum supply rating as permission to operate at 36 V under every load and temperature condition. Design around the ±2 V to ±18 V family range, confirm the selected amplifier's input common-mode limits, and verify output swing at the actual load. The 10 uV offset specification applies within its stated test conditions; resistor imbalance, input bias current, thermoelectric effects, and PCB leakage can still dominate a millivolt-level measurement.
Route the non-inverting and inverting inputs as short, symmetric, guarded traces, and keep the feedback loop compact. For high-impedance sensors, use a driven guard or physical shield around the input node to control leakage and surface contamination. Connect the analog return path so output-current noise and switching-node currents do not flow through the measurement reference. These layout practices protect the low-offset performance more effectively than additional gain.
Place local bypass capacitance from each supply pin to the appropriate analog ground node, using the capacitance and placement recommended in the manufacturer datasheet. Decouple the OPA277UA close to the device so switching supply noise is attenuated before it reaches the amplifier. Because the OPAx277 series provides high power-supply rejection, good supply decoupling remains the practical way to realize that rejection in a real board rather than treating the datasheet ratio as a substitute for layout.
Check stability with the intended gain, source impedance, output load, and any capacitive input or output loading before the PCB is released. Precision op amps can require noise-gain compensation in non-inverting or difference-amplifier topologies. Simulate the complete feedback network with the actual sensor impedance and cable capacitance, and confirm that the selected replacement part also remains stable under those same conditions.
コンプライアンス情報
Compliance status was not explicitly stated for the OPA277UA and must be confirmed from the current manufacturer product documentation before release to environmentally constrained or automotive programs.