Texas Instruments

THS1215CPW - 12-Bit 15 MSPS ADC | Texas Instruments

部品番号: THS1215CPW ✓ 生産中
3.3 V Vdss 28-pin TSSOP Package
MOQ: 1 |

THS1215CPW 概要

The Texas Instruments THS1215CPW is a 12-bit, 15 MSPS pipelined analog-to-digital converter with one analog input, a 3.3 V supply, and a 28-pin TSSOP package. Designed for low-power data-acquisition systems, it combines a compact sampling interface with parallel digital output and power-down capability for portable or intermittently operated equipment.

An ADC is an analog-to-digital converter, a data-acquisition IC that samples a continuous voltage and converts it into a numeric code. The THS1215CPW belongs to the pipelined ADC family, whose internal stages permit high conversion throughput while the final digital result is transferred through a parallel interface. Its position in the hierarchy is analog-to-digital converter → data-converter IC → signal-chain component, with the digital output intended for capture by an FPGA, DSP, microcontroller, or other digital processing system.

The principal specifications are 12-bit nominal resolution, a 15 MSPS maximum sampling rate, one analog input, and a 3.3 V operating supply. The manufacturer describes the device as a low-power ADC with power-down support, making it useful when acquisition duty cycle is below 100%. These values establish the part as a general-purpose high-speed sampler rather than a low-resolution slow ADC or a very-high-resolution waveform converter.

The 28-pin TSSOP package supports compact PCB layouts while exposing the converter's digital and control connections. Because a parallel ADC can produce a new 12-bit code every 66.7 ns at 15 MSPS, timing margins, output loading, clock quality, and PCB routing become important design considerations. The THS1215CPW uses a 3.3 V supply, so the digital interface, analog input range, clock amplitude, and downstream logic levels must all be evaluated together before finalizing the system power architecture.

Typical uses include industrial instrumentation, communications receivers, radar or sonar signal chains, medical monitoring, test and measurement equipment, and embedded control systems that need periodic high-speed sampling. In each case, the ADC can serve as the front-end conversion stage, while a processor evaluates the resulting samples for filtering, thresholding, demodulation, feature extraction, or closed-loop control.

Design the analog input path around the manufacturer's recommended source impedance and capacitor configuration. Keep the clock and parallel data traces short, provide a low-impedance reference and clean supply connections, and account for acquisition settling between samples. Paydown can reduce consumption between bursts, but the required enable timing and valid-data latency should be verified against the system control sequence.

This page organizes the THS1215CPW's core specifications, same-footprint alternatives, interface considerations, and application guidance into a practical engineering reference. It also distinguishes verified device identity and packaging from parameters that require confirmation in the manufacturer datasheet before a new PCB or production release is approved.

ドロップイン代替品: THS1215CPW — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: THS1215CPW (同一形状・フットプリント) — 相違点: Package, RoHS Status, Supply Voltage, Resolution, Architecture.

Texas Instruments
Package: 28-pin TSSOP (PW)
RoHS Status: Compliant (G4 suffix denotes lead-free / RoHS, per TI nomenclature)
Supply Voltage: 3.3 V (single supply)
比較対象 THS1215CPW →
Texas Instruments
Package: 28-TSSOP (PW)
RoHS Status: Compliant
Supply Voltage: 3.3 V (nominal)
比較対象 THS1215CPW →

THS1215CPWRG4

✅ ドロップイン
Texas Instruments
📦 28-pin TSSOP
12 bits · 15 MSPS · 1 input, pipelined · 3.3 V (single supply) · -2 V to +2 V (differential / single-ended) · Single-ended, single-ended with offset, or differential (Mode 1 gain = 1.0; Mode 2 gain = 0.5) · Parallel CMOS, binary output code · Internal (user-selectable ranges)

価格はお問い合わせください

データシートを見る →

THS1215CPWG4

✅ ドロップイン
📦 28-pin TSSOP
Same 12-bit, 15 MSPS ADC and 28-pin TSSOP footprint; ordering-suffix conditions require confirmation.

📋 参考代替品(カタログ未掲載)

THS1215CPWRG4

✅ ドロップイン
Texas Instruments
📦 28-pin TSSOP
12 bits · 15 MSPS · 1 input, pipelined · 3.3 V (single supply) · -2 V to +2 V (differential / single-ended) · Single-ended, single-ended with offset, or differential (Mode 1 gain = 1.0; Mode 2 gain = 0.5) · Parallel CMOS, binary output code · Internal (user-selectable ranges)

価格はお問い合わせください

データシートを見る →

THS1215IPWG4

✅ ドロップイン
Texas Instruments
📦 28-pin TSSOP
Texas Instruments · 12 bit · 15 MSPS · Pipelined · 1 · 3.3 V (nominal) · 28-TSSOP (PW) · Surface Mount

価格はお問い合わせください

データシートを見る →

THS1215IPWRG4

✅ ドロップイン
📦 28-pin TSSOP
Same 12-bit, 15 MSPS ADC and 28-pin TSSOP footprint; suffix-specific temperature and qualification conditions must be confirmed.

📋 参考代替品(カタログ未掲載)

THS1215CPW 最大定格&電気的特性

Converter Type Pipelined analog-to-digital converter
分解能 12 bit
サンプリングレート 15 MSPS
Number of Analog Inputs 1 input
Output Interface Parallel output
電源電圧 3.3 V
Power-Down Function Supported
パッケージ 28-pin TSSOP
Package Code PW
Terminal Count 28 terminals
Package Shape Rectangular
実装タイプ Surface mount
Temperature Grade Commercial
Analog Input Sampling Rate 15 MSPS
RoHS ステータス unknown
REACH Status unknown
AEC-Q100 Qualification unknown

THS1215CPW rectangular ピン配置ガイド

THS1215CPW (rectangular パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

THS1215CPW の rectangular パッケージピン配置図

詳細なピン配置データはありません: THS1215CPW.

詳細は データシート をご参照ください。

主な用途

THS1215CPW の用途: 6 件s: Industrial Process Instrumentation, Communications Receiver, Radar and Sonar Signal Acquisition, Medical Monitoring Equipment, Test and Measurement Instrumentation, Embedded Control and Data Logging.

🏭

Industrial Process Instrumentation

The THS1215CPW can serve as the high-speed conversion stage in industrial measurement systems that need to capture changing analog sensor or control signals. Its 12-bit resolution provides 4,096 numerical codes per conversion, while 15 MSPS permits rapid sampling of waveforms, vibration, or transient events. The 3.3 V architecture also integrates naturally with modern low-voltage control electronics. Place the ADC behind the manufacturer's recommended input-conditioning network, provide a clean reference and supply, and verify the selected ordering option against the equipment's ambient-temperature requirements. Power-down can be useful in portable or duty-cycled instruments, although wake-up timing should be included in the acquisition-control sequence.

🌐

Communications Receiver

A communications receiver can use the THS1215CPW to digitize intermediate-frequency or other bounded analog signals before digital filtering and demodulation. The device's 15 MSPS throughput gives the design a 66.7 ns maximum sampling interval, which is useful when the channel waveform contains timing information that must be retained. Its 12-bit parallel output can connect directly to a processor or FPGA input bank, subject to the clock and data-timing requirements in the manufacturer datasheet. The single analog input keeps the pin count and board area manageable for compact receiver boards. Clock jitter, input bandwidth, reference stability, and digital output timing require particular attention in high-frequency communication designs.

✈️

Radar and Sonar Signal Acquisition

The THS1215CPW is appropriate for radar, sonar, and other broadband signal-acquisition front ends where the analog waveform must be converted into parallel digital samples for later processing. A 15 MSPS conversion rate supports sampling of substantially faster events than a conventional slow instrumentation converter, while 12-bit resolution balances data volume against signal detail. In such systems, the ADC should be placed after a low-noise amplifier, anti-alias filter, and controlled-impedance input network. Designers should minimize loop area, preserve a continuous return path, and match clock and data trace lengths as far as practical. The datasheet's input range, acquisition time, and signal-to-noise characteristics should govern the actual bandwidth and dynamic-range design.

💊

Medical Monitoring Equipment

The THS1215CPW can support acquisition stages in medical monitoring and diagnostic equipment that capture rapidly varying analog waveforms. The 12-bit, 15 MSPS combination provides a practical balance between temporal resolution and parallel-output simplicity, allowing samples to be transferred to an FPGA or embedded processor for filtering and analysis. Because medical designs may impose strict safety, electromagnetic-interference, and calibration requirements, the ADC must be evaluated within the complete signal chain rather than selected from conversion rate alone. Confirm operating-temperature limits, analog performance, lifecycle status, and applicable quality documentation from the manufacturer. A low-noise input amplifier, controlled reference, and carefully decoupled 3.3 V supply are essential to preserve measurement integrity.

🔧

Test and Measurement Instrumentation

The THS1215CPW is useful in oscilloscope-like, automated test, and signal-analysis equipment that needs to sample an analog input and present a parallel digital stream to a processor. At 15 MSPS, the converter can capture waveform details that general-purpose MCU ADC channels cannot resolve, while 12-bit output reduces the storage and transfer burden relative to a higher-resolution converter. For a new instrument, use the manufacturer's recommended driver and reference topology, and keep the analog and digital return currents separated to reduce conversion-error coupling. The parallel bus should be routed according to the published timing specification. Power-down is valuable in instruments that spend substantial time idle or between automated test cycles.

🧩

Embedded Control and Data Logging

An embedded control system can use the THS1215CPW when an analog waveform must be sampled faster than the internal ADC of a microcontroller can support. The 12-bit parallel results can be latched by an FPGA, DSP, or suitable microcontroller logic, enabling filtering, peak detection, or control-loop updates without imposing a high-speed serial-converter interface on the processor. The 3.3 V supply supports integration with contemporary embedded logic, but level compatibility and timing margin must be checked carefully. Power-down allows the acquisition path to remain inactive during long control intervals. Before implementation, verify the converter's input range and acquisition requirements against the transducer or actuator interface, and add the manufacturer-recommended bypass and reference-decoupling network.

What is the resolution and sampling rate of the THS1215CPW?
The THS1215CPW is a 12-bit analog-to-digital converter with a maximum sampling rate of 15 MSPS. Texas Instruments identifies the device as a 3.3 V, low-power, single-input pipelined ADC. These figures make it appropriate for signal capture in industrial instrumentation, communications, radar, test equipment, and other systems that require substantially faster sampling than a low-speed instrumentation ADC.
Where can I download the THS1215CPW datasheet PDF?
The THS1215CPW datasheet PDF is available through the linked AllDataSheet document and through the Texas Instruments product documentation. The device is described as a 3.3 V, 12-bit, 15 MSPS low-power analog-to-digital converter with power-down. Use the manufacturer datasheet as the controlling source for the complete pin description, electrical characteristics, recommended application circuit, and timing diagrams.
Where can I find the THS1215CPW pinout?
Use the pin-description table and package drawing in the Texas Instruments THS1215 datasheet to locate every THS1215CPW connection. The verified component identity identifies a 28-pin TSSOP package with package code PW and parallel digital outputs. Because the public listing excerpt does not reproduce individual terminal names, request the manufacturer datasheet before assigning PCB nets or checking signal compatibility by pin number.
Where can I buy THS1215CPW and request a quote?
Use the Request a Quote form on this page to request THS1215CPW availability, quantity breaks, and current lead time. The part is identified as a Texas Instruments 12-bit, 15 MSPS, 28-pin TSSOP ADC. For production planning, include the required quantity, date code preference, target delivery location, and whether the order must be supplied in tape-and-reel or tube packaging.
What is the current price of THS1215CPW?
Submit the Request a Quote form on this page for the current THS1215CPW unit price and available quantity breaks. Commercial terms can depend on order quantity, packaging, date code, and supply status, so a static unit figure may not reflect the configuration needed for production. The form also provides a direct route for confirming current lead time and allocation.
Is THS1215CPW in stock and what is its lead time?
Submit the Request a Quote form on this page to check current THS1215CPW stock, scheduled shipment quantities, and lead time. Because availability can change with purchasing volume and package configuration, request the quantity and packaging required for your build. The request should state the target ship date so the supplier can confirm the most relevant schedule.
What is the best drop-in replacement for THS1215CPW?
THS1215CPWRG4 is the closest documented drop-in candidate for THS1215CPW because it retains the same 12-bit, 15 MSPS ADC architecture and 28-pin TSSOP footprint. Cross-reference records describe its terminals, package, and functional characteristics as consistent with the original device. Verify temperature range, packing, clocking, and production qualification in the manufacturer documentation before approving a substitution.
Can THS1215IPW replace THS1215CPW?
THS1215IPW is a same-family, 28-pin TSSOP candidate for THS1215CPW, but it should be treated as a conditional replacement rather than assumed equivalent. The comparison record identifies the same 12-bit, 15 MSPS single-input pipelined ADC format, while suffix differences can represent distinct temperature, packaging, or qualification conditions. Confirm those orderable details and the pin-level functions in the manufacturer datasheet.
THS1215CPW vs THS1215CPWRG4 — which is the better replacement?
THS1215CPWRG4 is generally the stronger documented replacement for THS1215CPW because the comparison record identifies a complete replacement with consistent terminals, package, and principal performance characteristics. Both parts are 12-bit, 15 MSPS ADCs in 28-pin TSSOP packages. Choose the alternative only after checking its suffix-specific temperature grade, reel or tube configuration, lifecycle status, and quality-document requirements.
What is the difference between THS1215CPW and THS1215IPW?
THS1215CPW and THS1215IPW are both presented as 12-bit, 15 MSPS, single-input pipelined ADCs in 28-pin TSSOP packages. Their ordering suffixes can indicate different commercial conditions, so the shared resolution and speed do not by themselves prove full interchangeability. Use the manufacturer ordering table to compare temperature range, packaging, and qualification, then verify the pin description and electrical limits.
When should I choose THS1215CPW instead of THS1215CPWRG4?
Choose THS1215CPW when its exact ordering configuration is the part specified for your design and the THS1215CPWRG4 suffix does not satisfy your packaging, temperature, or qualification requirements. THS1215CPWRG4 is attractive when its documented configuration is a complete replacement and its orderable details match the production build. For either part, compare the full ordering table rather than relying only on the shared 12-bit, 15 MSPS description.
Is THS1215CPW suitable for industrial data acquisition?
The THS1215CPW is suitable for many industrial data-acquisition applications because it provides 12-bit resolution, 15 MSPS throughput, a 3.3 V supply, and power-down capability. Industrial suitability also depends on the specified temperature grade, EMC performance, long-term availability, and system calibration requirements. Confirm those characteristics in the manufacturer datasheet before using it in a production machine or safety-adjacent installation.
How should I design the analog input and clock for THS1215CPW?
Design the analog input and clock according to the manufacturer's recommended application circuit and timing diagrams. The 15 MSPS rate means a new conversion interval of about 66.7 ns, so source settling, clock jitter, return paths, and parallel-output timing must be considered. The available excerpt does not specify the input range or recommended impedance, so use the datasheet values for those network-design calculations.
Can power-down improve power consumption in a THS1215CPW design?
Yes. The THS1215CPW includes a power-down function, allowing a design to disable the converter during intervals when sampling is not required. This can reduce energy use in duty-cycled acquisition systems, but the enable timing and wake-up behavior must follow the manufacturer timing specifications. The measured benefit depends on how long the device remains powered down and how often it is restarted.
What are the key specifications engineers should know about THS1215CPW?
The essential THS1215CPW specifications are 12-bit resolution, a 15 MSPS sampling rate, one analog input, a 3.3 V supply, parallel output, power-down support, and a 28-pin TSSOP package. Texas Instruments describes it as a low-power pipelined ADC. Before design release, confirm analog input range, INL, DNL, ENOB, reference requirements, timing, and operating temperature from the manufacturer datasheet.
What is the best Texas Instruments equivalent for THS1215CPW?
THS1215CPWRG4 is the best-supported Texas Instruments equivalent in the available cross-reference records because it is described as a complete replacement with consistent terminals, package, and primary performance characteristics. THS1215IPW, THS1215IPWRG4, THS1215CPWR, and THS1215CPWG4 are additional same-family candidates. Each should be checked against the required temperature grade, shipping configuration, qualification status, and current lifecycle condition.

エンジニアリング参考データ: THS1215CPW — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose THS1215CPW when the design needs a 12-bit, 15 MSPS, single-input pipelined ADC on a 3.3 V supply and the original ordering configuration meets the product's temperature, quality, and lifecycle requirements. Choose THS1215CPWRG4 when its suffix-specific conditions are preferable and the cross-reference record's same-footprint, functionally consistent construction is sufficient for qualification. THS1215CPWG4 and THS1215CPWR are same-family options with matching 12-bit, 15 MSPS and 28-pin TSSOP characteristics, but each ordering suffix must be checked for packing and qualification differences. Consider THS1215IPW or THS1215IPWRG4 only after confirming that the I-suffix temperature and ordering conditions suit the installation. For every alternative, verify the pin list, electrical limits, clocking, reference requirements, and lifecycle status; matching the converter headline specifications alone does not establish complete system equivalence.

代替品との比較

パラメータ この製品 THS1215CPWRG4 THS1215CPWG4 THS1215CPWR THS1215IPW THS1215IPWRG4
Package 28-pin TSSOP 28-pin TSSOP - same 28-pin TSSOP - same 28-pin TSSOP - same 28-pin TSSOP - same 28-pin TSSOP - same
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
ADC Architecture Pipelined Pipelined Pipelined Pipelined Pipelined Pipelined
Resolution 12 bit 12 bit 12 bit 12 bit 12 bit 12 bit
Sampling Rate 15 MSPS 15 MSPS 15 MSPS 15 MSPS 15 MSPS 15 MSPS
Analog Input Count 1 input 1 input 1 input 1 input 1 input 1 input
Supply Voltage 3.3 V 3.3 V 3.3 V 3.3 V 3.3 V 3.3 V
Output Interface Parallel Parallel Parallel Parallel Parallel Parallel
Power-Down Function Supported Supported Supported Supported Supported Supported
Ordering-Specific Conditions Commercial grade; full ordering details require confirmation RG4 suffix conditions require confirmation G4 suffix conditions require confirmation R suffix conditions require confirmation I suffix conditions require confirmation IPWRG4 suffix conditions require confirmation

主な差別化要因

  • Documented same-family replacement path (vs THS1215CPWRG4)
  • Single-input pipelined conversion at 15 MSPS (vs THS1215IPW)
  • Compact 28-pin TSSOP implementation (vs THS1215CPWR)

設計ノート

Route the 12-bit parallel output conservatively because a new conversion can occur every 66.7 ns at 15 MSPS. Use the manufacturer timing diagram to establish setup and hold margins, keep the bus traces short, provide a continuous ground reference, and avoid stubs or test-point structures that materially change loading. Confirm the receiving FPGA or processor voltage levels and interface timing against the THS1215CPW datasheet before finalizing the parallel bus topology.

Implement the analog input as a controlled-impedance path rather than directly connecting a high-impedance sensor to the converter. Use the manufacturer's recommended series-resistance and charge-injection capacitor arrangement to promote acquisition settling, and place the network close to the ADC pins. The available listing confirms the 15 MSPS rate but not the permitted source impedance, so calculate settling from the datasheet's acquisition-time, input-capacitance, and switch-resistance values.

Separate analog and digital return currents where possible and follow the manufacturer's reference and bypass-capacitor layout. The THS1215CPW operates from 3.3 V, and reference or supply disturbance can appear directly as conversion error. Keep switching regulators and high-current digital paths away from the input and reference nodes, and use separate ground-plane connections that join at a controlled point near the power entry and analog return.

Do not treat equal resolution and sampling rate as sufficient proof that every ordering suffix is interchangeable. Before replacing THS1215CPW, compare the manufacturer ordering table for temperature grade, package shipping method, qualification status, and lifecycle status. Also verify that the replacement uses the same 28-pin TSSOP footprint and that all clock, reference, control, and parallel-output functions are assigned identically on the PCB.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations were identified for this exact ordering configuration. Confirm environmental and quality compliance with the manufacturer before production release.

データ検証日: 2026-11-16 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

THS1215CPW datasheet THS1215CPW pinout THS1215CPW datasheet pdf THS1215CPW specifications THS1215CPW equivalent THS1215CPW replacement THS1215CPW cross reference THS1215CPW price THS1215CPW stock Texas Instruments THS1215CPW THS1215CPW 28-TSSOP THS1215CPW application circuit THS1215CPW vs THS1215CPWRG4

関連部品&用語

Texas Instruments THS1215CPW THS1215CPWRG4 THS1215CPWG4 THS1215CPWR THS1215IPW THS1215IPWRG4 analog-to-digital converter ADC pipelined ADC data-converter IC signal-chain component 12-bit resolution 15 MSPS sampling rate parallel output 3.3 V power supply power-down function 28-pin TSSOP TSSOP package family surface-mount package FPGA DSP microcontroller industrial data acquisition communications receiver
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示