TIOL1125 - IO-Link Transceiver 5V LDO Surge Protection | TI
部品番号: TIOL1125 ✓ 生産中| 数量 | 単価 | 小計 |
|---|---|---|
| 1 | $2.35 | $2.35 |
| 10 | $2.11 | $21.10 |
| 100 | $1.78 | $178.00 |
| 500 | $1.52 | $760.00 |
| 1,000 | $1.29 | $1,290.00 |
TIOL1125 概要
An IO-Link device transceiver is a physical layer interface IC that enables point-to-point communication between sensors or actuators and an IO-Link master, carrying both power and data over a standard 3-wire cable. As part of the industrial networking and interface IC hierarchy, it integrates drivers, receivers, surge protection, and voltage regulation between the sensor microcontroller and the IO-Link cable.
Key features include an integrated linear regulator (LDO) specified for L+ voltages from 7 V to 36 V with respect to L-, supplying 5 V to external components such as the sensor MCU; a typical residual voltage of only 0.5 V at 200 mA, reducing power dissipation; and a configurable output driver supporting PNP, NPN, or IO-Link modes. Functional-safety-capable documentation is available to support IEC 61508 system design.
The TIOL1125 integrates the C/Q driver and receiver with surge protection per the IO-Link physical layer, reducing external TVS and driver components. Remote wake-up indication and generation plus a configurable current limiter improve robustness and simplify compliance testing. COM1 (4.8 kbps), COM2 (38.4 kbps), and COM3 (230.4 kbps) data rates are supported for flexible system design.
Typical applications include industrial proximity and photoelectric sensors, actuators, valve positioners, and IO-Link device nodes in factory automation and smart manufacturing. The small VSON-10 package suits space-constrained sensor housings, while the wide supply range and integrated protection suit harsh industrial environments.
Design tip: place decoupling close to the L+ and L- pins and the LDO output capacitor near the VCC pin to ensure regulator stability; verify integrated surge protection against your system EMC test levels.
ドロップイン代替品: TIOL1125 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
クイック比較ツール — 並列比較する代替部品を選択:
TIOL1123DRCR
✅ ドロップイン📋 参考代替品(カタログ未掲載)
TIOL1115
✅ ドロップイン📋 参考代替品(カタログ未掲載)
TIOL111
✅ ドロップイン📋 参考代替品(カタログ未掲載)
TIOL1125 仕様
| 機能 | IO-Link device transceiver with 5-V LDO |
| Supply Voltage Range (L+) | 7 V to 36 V |
| LDO Output Voltage | 5 V |
| Residual Voltage | 0.5 V typical at 200 mA |
| 出力構成 | PNP, NPN, or IO-Link configurable |
| Data Rates | COM1 (4.8 kbps), COM2 (38.4 kbps), COM3 (230.4 kbps) |
| Standard Compliance | IEC 61131-9 IO-Link physical layer |
| Surge Protection | Integrated |
| Wake-up Support | Remote wake-up indication and generation |
| Current Limiter | Configurable |
| Functional Safety | Functional-safety-capable, documentation available |
| パッケージ | VSON-10 (DRC, 3x3 mm) |
| 実装タイプ | Surface Mount |
| Pin Compatibility | Pin-compatible with TIOL111 family |
TIOL1125 ピン構成
| ピン 1 | L+ — IO-Link positive supply input (7 V to 36 V) |
| ピン 2 | L- — IO-Link supply return / ground |
| ピン 3 | C/Q — IO-Link switching/communication line (driver and receiver) |
| ピン 4 | VCC — 5-V LDO output for external components |
| ピン 5 | M — Microcontroller interface mode selection |
| ピン 6 | TX — Transmit data input from MCU |
| ピン 7 | RX — Receive data output to MCU |
| ピン 8 | EN — Enable / wake-up control |
| ピン 9 | I_SET — Current limit configuration |
| ピン 10 | GND — Ground |
主な用途
TIOL1125 の用途: 6 件s: IO-Link Industrial Proximity Sensors, Photoelectric Sensor IO-Link Nodes, Actuators and Valve Positioners, Factory Automation IO-Link Masters and Device Networks, Condition Monitoring and Smart Sensor Retrofits, Functional-Safety-Oriented Sensor Systems.
IO-Link Industrial Proximity Sensors
The TIOL1125 fits inductive and capacitive proximity sensor IO-Link nodes because its C/Q driver supports PNP, NPN, and IO-Link modes with IEC 61131-9 COM1/COM2/COM3 rates, letting one hardware platform serve both standard and IO-Link sensor variants. The integrated surge protection and 36-V tolerant supply handle industrial cable transients without external TVS diodes, and the 0.5-V typical residual voltage at 200 mA reduces on-board dissipation in compact sensor housings. The 5-V LDO powers the sensor MCU directly from the L+ line, eliminating a separate regulator.
おすすめ
Photoelectric Sensor IO-Link Nodes
Photoelectric sensors benefit from the TIOL1125's configurable current limiter and remote wake-up generation, which are required for IO-Link device compliance testing. The COM3 (230.4 kbps) support allows fast parameter and process-data exchange with the IO-Link master, while the functional-safety-capable documentation aids machine-level safety assessments. The VSON-10 (3x3 mm) footprint is small enough for tight optical-head PCBs, and the 7-V to 36-V L+ range tolerates cable-drop variations in long sensor runs on factory floors.
おすすめ
Actuators and Valve Positioners
For pneumatic valve positioners and small actuators, the TIOL1125 provides a robust PNP/NPN output stage with configurable current limiting, protecting the driver during stall or short-circuit events on the actuator line. The integrated LDO (5 V, 7-V to 36-V input) supplies the position-feedback electronics from the same 3-wire IO-Link cable that carries data, simplifying wiring. Low residual voltage reduces heat in sealed enclosures where convection cooling is limited, improving long-term reliability of the actuator drive stage.
おすすめ
Factory Automation IO-Link Masters and Device Networks
In smart-manufacturing networks, every IO-Link device port needs a robust physical layer. The TIOL1125 complies with IEC 61131-9 for COM1 through COM3, so a single device design interoperates with any compliant master. Integrated surge protection simplifies EMC qualification of dense multi-port master or device boards, and the 0.5-V residual voltage lowers per-node power loss when dozens of devices share a cabinet supply. Pin compatibility with TIOL111 enables cost-optimized BOM migration across product generations.
おすすめ
Condition Monitoring and Smart Sensor Retrofits
Retrofitting legacy 3-wire PNP/NPN sensors with IO-Link capability is a common Industry 4.0 upgrade path. The TIOL1125 supports both legacy discrete output modes and IO-Link communication on the same hardware, so one PCB serves old and new installations. Remote wake-up indication lets the sensor sleep between measurements, cutting average power draw, while the LDO output powers the added intelligence (MCU plus MEMS sensor). Wide L+ tolerance absorbs unregulated plant supply variation during retrofit deployments.
おすすめ
Functional-Safety-Oriented Sensor Systems
The TIOL1125 is functional-safety-capable with documentation available to aid IEC 61508 system design, making it appropriate for safety-related sensor nodes such as light curtains, safety interlocks, and emergency-stop position feedback. Deterministic IO-Link communication at COM2 or COM3 with wake-up support enables safe parameterization and diagnostics. The integrated current limiter and surge protection reduce the external component count that would otherwise need individual safety analysis, shortening the system-level safety assessment cycle.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: TIOL1125 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | TIOL1123DRCR | TIOL1115 | MAX14827A |
|---|---|---|---|---|
| Package | VSON-10 (DRC, 3x3 mm) | VSON-10 (DRC, 3x3 mm) - same | VSON-10 (DRC, 3x3 mm) - same | TQFN - different |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Analog Devices |
| IO-Link Data Rates | COM1, COM2, COM3 | COM1, COM2, COM3 | COM1, COM2, COM3 | COM1, COM2, COM3 |
| Pin Compatibility | Pin-compatible with TIOL111 | Pin-for-pin with TIOL1125 | Pin-compatible family | Not pin-compatible |
主な差別化要因
- Lowest residual voltage in family (vs TIOL1115)
- 5-V LDO vs 3-V LDO (vs TIOL1123DRCR)
- Integrated 5-V LDO (vs TIOL111)
設計ノート
Place a decoupling capacitor close to the L+ and L- pins and the LDO output capacitor near the VCC pin to ensure regulator stability across load transients. Keep the C/Q trace short and route it away from sensitive analog signals to minimize coupling during COM3 (230.4 kbps) communication. The VSON-10 exposed pad should be soldered to a ground pour for thermal and EMC performance.
Do not exceed the 36-V maximum L+ voltage; unregulated industrial 24-V supplies can spike well above nominal during load dumps, so verify the integrated surge protection covers your system EMC test levels (surge, burst, ESD per IO-Link test specification) before skipping external TVS diodes entirely. Confirm the LDO output (5 V on TIOL1125 vs 3 V on TIOL1123) matches your MCU supply before substituting family members.
The 0.5-V typical residual voltage at 200 mA reduces on-state dissipation to about 0.1 W in the driver, but total budget must include LDO dropout from L+ to 5 V. At 24-V L+ and 50-mA LDO load, the device dissipates roughly 0.95 W - use the exposed pad and at least 2x2 via fanout to the ground plane to keep junction temperature within limits in sealed sensor housings.
The configurable current limiter setting resistor should be placed close to the I_SET pin with a low-impedance ground return to avoid false limiting during COM3 drive transitions. If wake-up signaling is used, keep the EN/wake-up trace away from the C/Q line to prevent spurious wake-up from cable transients.
コンプライアンス情報
Compliance data not present in provided sources; check TI product page quality summary. Functional-safety-capable documentation is available per datasheet.