Analog Devices

71M6103-IL/F - 22-Bit Isolated Energy Meter ADC | Analog Devices

부품 번호: 71M6103-IL/F ✗ 단종
재고 있음 영업일 기준 1~3일 내 발송
Integrated supply-voltage generator energized by host power pulses Vdss Shunt-based sensing Id 8-pin SOIC Package
문의하기 가격 문의
MOQ: 1 |
가격 업데이트: 2026-10-20
볼륨 가격
수량 단가 합계
1 $0 $0.00
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ 모든 가격은 USD 기준입니다

71M6103-IL/F 개요

The Analog Devices 71M6103-IL/F is an isolated sensor IC for three-phase energy metering, featuring a 22-bit delta-sigma ADC and an 8-pin SOIC package. Designed for electricity-meter designs, it supports shunt-based current sensing through an isolated pulse-transformer interface and is powered by energy pulses supplied by the 71M654x host family. The device includes a differential-input amplifier, precision voltage reference, temperature sensor, and supply-voltage generator, consolidating measurement functions into one metering-specific IC.

An isolated sensor IC is a specialized analog-to-digital conversion device that transfers measurement information across an isolation barrier while allowing a host controller to operate independently from the sensed power line. In the broader hierarchy, this device belongs to the ADC and DAC category, then to isolated sensor and energy-metering ICs, and finally to the broader semiconductor and power-management measurement ecosystem. Its isolation architecture is intended to replace high-cost current transformers in selected electricity-meter designs.

The verified manufacturer data identifies the 71M6103 as an obsolete isolated sensor IC for electricity-meter designs. Its 22-bit delta-sigma ADC, differential amplifier, precision reference, temperature sensor, and pulse-powered supply generator form a measurement signal chain optimized for host-based energy-meter processing. The 8-pin SOIC option supports compact board layouts, while the isolated interface is intended to carry power, data, and timing information across a pulse-transformer-based isolation barrier.

The 71M6103 family is designed for selected Silergy host system-on-chips and poly-phase meters where shunt sensing can replace conventional current transformers. Using shunt-based sensing can reduce system size and component cost when the meter architecture supports the required isolation and accuracy. The host must provide suitable power pulses, timing, and data handling because the sensor interface is not a standalone universal energy-metering solution.

Typical applications include three-phase electricity meters, poly-phase energy meters, isolated current-sensing channels, industrial power monitoring, and smart-grid measurement modules. The design is most appropriate where the board already implements the compatible host controller and isolation-transformer network. It is not appropriate for generic low-voltage signal acquisition without the associated metering architecture.

The principal design consideration is system integration: preserve the pulse-transformer isolation path, maintain the required differential sensor connection, and verify timing and supply compatibility with the selected 71M654x-class host. Because the manufacturer lists the device as obsolete, engineers should confirm availability and migration options before committing to new production designs.

This page combines verified manufacturer and distributor information with an explicit obsolete-status assessment, application guidance, design notes, and replacement-screening context to support practical engineering decisions.

드롭인 대체품: 71M6103-IL/F — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

71M6103-ILR/F

✅ 드롭인
📦 8-pin SOIC
Ordering-code variant listed in distributor cross-reference results; exact electrical and pin differences are not quantified in the supplied data

📋 참조 대체품 (카탈로그에 없음)

71M6103-IL/F

✅ 드롭인
Analog Devices
📦 8-pin SOIC
Isolated sensor IC for three-phase energy metering · 22-bit delta-sigma ADC · Differential inputs · Integrated differential-input amplifier · Precision voltage reference · Integrated temperature sensor · Integrated supply-voltage generator energized by host power pulses · Pulse-transformer-based isolation interface

✓ 재고 있음

가격 문의

데이터시트 보기 →

71M6103-IL/F 최대 정격 & 전기적 특성

Device Type Isolated sensor IC for three-phase energy metering
ADC Architecture 22-bit delta-sigma ADC
Input Type Differential inputs
Amplifier Integrated differential-input amplifier
Reference Precision voltage reference
Temperature Sensor Integrated temperature sensor
Supply Generator Integrated supply-voltage generator energized by host power pulses
Isolation Interface Pulse-transformer-based isolation interface
Isolation Carried Signals Power, data, and timing
Metering Phase Support Three-phase meter designs
Current Sensing Method Shunt-based sensing
Current Transformer Replacement Designed to eliminate selected high-cost current transformers
Host Compatibility Selected 71M654x host family
패키지 8-pin SOIC
실장 유형 Surface mount
수명 주기 상태 Obsolete

71M6103-IL/F 8-pin soic 핀 구성 가이드

71M6103-IL/F(8-pin soic 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.

71M6103-IL/F의 8-pin soic 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: 71M6103-IL/F.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

71M6103-IL/F 적합 용도: 6 애플리케이션s: Three-Phase Electricity Meter, Poly-Phase Smart Meter, Isolated Current-Sensing Channel, Industrial Power Monitoring Module, Smart-Grid Metering Platform, Legacy Meter Repair and Spare Unit.

⚡

Three-Phase Electricity Meter

The 71M6103-IL/F fits a three-phase electricity-meter signal chain that needs isolated current measurement and a high-resolution conversion function. Its verified 22-bit delta-sigma ADC and differential-input amplifier can support measurement conditioning, while the integrated precision reference and temperature sensor provide dedicated metering support. The device is intended to operate with the compatible 71M654x host architecture and pulse-transformer isolation network rather than as a stand-alone ADC. The key design benefit is the possibility of replacing selected current transformers with shunt-based sensing, but the complete isolation path, timing, and host interface must be validated against the manufacturer datasheet.

🧩

Poly-Phase Smart Meter

The 71M6103-IL/F is applicable to poly-phase smart-meter designs when the meter uses shunt sensing and pulse-transformer isolation. The 22-bit delta-sigma conversion function is appropriate for capturing phase-related measurement information, while the integrated temperature sensor and voltage reference support the metering signal chain. The verified family description specifically identifies shunt replacement for current transformers in poly-phase meters. Engineers must confirm host-controller timing, isolation transformer selection, differential input conditioning, and board layout because the device is not a universal replacement for conventional standalone metering ADCs.

🏭

Isolated Current-Sensing Channel

Use the 71M6103-IL/F when an isolated current-sensing channel must communicate measurement information across a pulse-transformer barrier. The differential-input amplifier and 22-bit delta-sigma ADC are relevant to shunt-based current measurement, while the supply-voltage generator allows the sensing side to be energized by host-provided power pulses. This architecture can reduce reliance on selected current transformers in electricity-meter products. The design must preserve the required isolation topology and must not assume that the part is suitable for arbitrary industrial current inputs without checking range, accuracy, timing, and safety requirements.

🏭

Industrial Power Monitoring Module

The 71M6103-IL/F may be considered for specialized industrial power-monitoring modules that use the same isolated metering architecture as electricity meters. Its differential ADC front end, precision reference, temperature sensor, and pulse-powered isolation interface provide a compact measurement channel for phase-current monitoring. The main trade-off is specialization: the device is tied to a compatible host and isolation interface, so it is less flexible than a general-purpose high-resolution ADC. Validate the analog input range, timing, isolation rating, operating environment, and production availability before deploying it outside the intended metering architecture.

🌐

Smart-Grid Metering Platform

The 71M6103-IL/F can support isolated measurement front ends in smart-grid meter platforms that require energy information to cross an isolation barrier. Its 22-bit delta-sigma ADC is suited to precision-oriented metering, and the pulse-transformer interface carries power, data, and timing between the sensing and processing domains. The integrated voltage reference and temperature sensor help consolidate the measurement chain. Because the manufacturer classifies the device as obsolete, a new smart-grid platform should confirm lifecycle risk, host availability, and a supported redesign path rather than relying on legacy supply indefinitely.

🔧

Legacy Meter Repair and Spare Unit

The 71M6103-IL/F remains relevant for repairing or maintaining older electricity-meter platforms that already use its 8-pin SOIC footprint, host protocol, and pulse-transformer isolation network. In this use case, preserving the original architecture is more important than finding a newer general-purpose ADC. The obsolete lifecycle status means procurement should be based on verified distributor stock, traceability, and assembly documentation. Before substitution, compare the complete pinout, electrical limits, timing, isolation interface, and calibration expectations; package similarity alone does not establish drop-in compatibility.

추천 제품 요약

71M654x Compatible host family identified by the manufacturer documentation 사용처: Three-Phase Electricity Meter, Poly-Phase Smart Meter, Isolated Current-Sensing Channel, Industrial Power Monitoring Module, Smart-Grid Metering Platform, Legacy Meter Repair and Spare Unit
What is the Analog Devices 71M6103-IL/F?
The 71M6103-IL/F is an obsolete isolated sensor IC for three-phase energy metering. According to the Analog Devices product page and manufacturer datasheet, it combines a 22-bit delta-sigma ADC, differential-input amplifier, precision voltage reference, temperature sensor, and supply-voltage generator. The verified device information identifies an 8-pin SOIC option and pulse-transformer-based isolation for selected electricity-meter designs.
What is the operating principle of the 71M6103-IL/F?
The 71M6103-IL/F uses a pulse-transformer-based isolation interface to transfer power, data, and timing between the sensing circuit and a compatible host controller. Its ADC is a 22-bit delta-sigma type with differential inputs. The verified manufacturer description states that the supply-voltage generator is energized by power pulses provided by the 71M654x host family.
Is the 71M6103-IL/F suitable for shunt-based current sensing?
Yes, the 71M6103-IL/F is designed for selected shunt-based energy-meter applications. The manufacturer documentation describes shunt sensing as an approach that can eliminate high-cost current transformers in selected poly-phase meter designs. The system must still include the required pulse-transformer isolation network, compatible host controller, sensor interface, and layout validated for the target meter.
What package does the 71M6103-IL/F use?
The verified product information identifies the 71M6103-IL/F as an 8-pin SOIC device. The available Silergy product listing also identifies an 8-pin SOIC package option for the 71M6103 family. Confirm the exact package drawing, pin mapping, exposed-pad details, and assembly requirements against the manufacturer datasheet before layout release.
Is the 71M6103 obsolete?
Yes, the Analog Devices product page explicitly identifies the 71M6103 as obsolete. The distributor listing remains available for sourcing, but obsolete status means new-production commitment should be reviewed carefully. For an active design, check authorized-channel availability, last-time-buy information, approved alternatives, and any manufacturer migration guidance before making a purchasing decision.
Where can I download the 71M6103-IL/F datasheet PDF?
The official manufacturer datasheet is available at https://www.analog.com/media/en/technical-documentation/data-sheets/71m6103-71m6603.pdf. The Analog Devices product page is https://www.analog.com/en/products/71m6103.html. The datasheet is the authoritative source for electrical limits, timing, isolation details, recommended external circuitry, and package-specific information.
What is the difference between the 71M6103 and a conventional energy-meter ADC?
The 71M6103 is not only a generic ADC; it is an energy-metering-specific isolated sensor IC. In addition to the 22-bit delta-sigma ADC, it integrates a differential-input amplifier, precision reference, temperature sensor, and supply-voltage generator. Its pulse-transformer isolation interface is designed for power, data, and timing transfer in compatible 71M654x-based meter architectures.
What host controller works with the 71M6103-IL/F?
The verified manufacturer documentation states that the 71M6xxx isolated sensor ICs use power pulses provided by the 71M654x host family. The Silergy family listing further identifies support for selected Silergy host system-on-chips. Host selection must be checked against the complete interface requirements, timing, isolation topology, and application schematic rather than relying on family naming alone.
What is the best drop-in replacement for the 71M6103-IL/F?
No independently verified drop-in replacement is established by the supplied cross-reference data. The Analog Devices 71M6103 product page identifies the device as obsolete, while the search results contain the original family and distributor listings but do not confirm a pin-compatible substitute with quantified electrical equivalence. Treat any replacement candidate as unverified until its package, pinout, interface protocol, ADC resolution, isolation method, and host compatibility are confirmed.
Can a Silergy 71M6103 replace the Analog Devices 71M6103-IL/F?
A Silergy 71M6103-family device may be relevant because the verified Silergy listing describes the same isolated 22-bit ADC energy-metering concept and an 8-pin SOIC option. However, the supplied data does not establish that a specific Silergy ordering code is pin-to-pin and timing-compatible with 71M6103-IL/F. Do not approve it as a drop-in replacement without comparing the complete datasheets and host-interface implementation.
Where can I buy the 71M6103-IL/F online?
The verified distributor records list DigiKey, Mouser, Octopart, and other sourcing pages for 71M6103-IL/F. The exact current price, stock, and shipping status are not included in the supplied snippets, so this page does not assert a numeric quote or guaranteed availability. Check authorized distributor inventory and request a written quotation before placing an order, especially because the manufacturer lists the device as obsolete.
What is the price of the 71M6103-IL/F?
A verified current unit price for 71M6103-IL/F is not present in the supplied data. The DigiKey and Mouser result pages indicate that product and price information is available, but the snippets do not provide numeric tiers. Therefore, the pricing tiers in this record are marked as zero rather than guessed; obtain a current quote from the distributor as of 2026-10-21.
What is the lead time for the 71M6103-IL/F?
The supplied data does not provide a verified lead time for 71M6103-IL/F. One distributor snippet says the part ships today, but that statement is not tied to a stated quantity, inventory level, or date-specific commitment. Because the device is obsolete, confirm current stock, allocation, and lead time directly with an authorized distributor as of 2026-10-21.
Is the 71M6103-IL/F suitable for industrial power monitoring?
It may be suitable for isolated current measurement in specialized industrial power-monitoring equipment, provided the host controller, pulse-transformer interface, and sensing network match the 71M6xxx architecture. The verified application focus is electricity metering rather than general-purpose industrial instrumentation. Review isolation requirements, accuracy, input range, safety certification, and environmental specifications before using it outside the intended meter architecture.
What are the key specifications of 71M6103-IL/F engineers should know?
The key verified specifications are a 22-bit delta-sigma ADC, differential inputs, integrated differential-input amplifier, precision voltage reference, temperature sensor, supply-voltage generator, pulse-transformer isolation, three-phase energy-meter positioning, and an 8-pin SOIC option. The device is powered through pulses from a compatible 71M654x host, carries power/data/timing across the isolation interface, and is listed as obsolete. Other electrical limits require the manufacturer datasheet.
How should engineers handle an obsolete 71M6103-IL/F in a new design?
Engineers should first confirm whether the existing meter architecture can remain unchanged and whether authorized-channel supply is reliable. If a new design is required, evaluate the original Analog Devices datasheet, compatible host devices, and any manufacturer migration guidance. Because the supplied sources do not verify a drop-in substitute, a PCB-only replacement cannot be assumed; validate package, pinout, timing, isolation, accuracy, and lifecycle requirements before release.

엔지니어링 참조 데이터: 71M6103-IL/F — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the Analog Devices 71M6103-IL/F when maintaining an existing three-phase electricity-meter design that already uses the 71M654x host ecosystem, pulse-transformer isolation, and the associated shunt-sensing interface. Its integrated 22-bit delta-sigma ADC, differential amplifier, reference, temperature sensor, and supply generator can simplify replication of the original architecture. Do not select it for a new design without confirming lifecycle strategy because Analog Devices lists the device as obsolete. Consider 71M6103-ILR/F only after comparing the manufacturer ordering-code data and pin-level electrical specifications. Treat the Silergy 71M6103 family listing as a promising sourcing lead, not a confirmed drop-in replacement, until package, pinout, timing, isolation, calibration, and host compatibility are independently verified.

대체품과의 비교

파라미터 이 제품 71M6103-ILR/F 71M6103-IL/F
Package 8-pin SOIC 8-pin SOIC package option reported in supplied distributor data; exact package drawing requires verification 8-pin SOIC package option reported for the Silergy family listing; exact ordering-code equivalence requires verification
Brand Analog Devices Analog Devices Silergy

주요 차별점

  • Metering-specific integration (vs 71M6103-ILR/F)
  • Isolation interface architecture (vs 71M6103-IL/F Silergy listing)
  • System integration versus generic ADC use (vs General-purpose energy-meter ADC)

설계 노트

Do not treat a matching 8-pin SOIC outline as proof of drop-in compatibility. Before substituting any 71M6103-family candidate, compare the complete pin assignment, pulse-transformer connections, host timing, differential input polarity, supply-energy requirements, calibration behavior, and isolation implementation against the original 71M6103-IL/F datasheet. The supplied search results confirm family-level functionality but do not provide a complete pin-level equivalence table for the alternative ordering codes.

Keep the isolated sensing path and pulse-transformer interface layout consistent with the manufacturer reference implementation. Maintain controlled separation between the power/domain conductors and the data/timing conductors, use the recommended component values and transformer connections, and avoid adding unverified long copper paths around the isolation barrier. Because the device is obsolete, preserve the original approved layout when repairing an existing meter rather than improvising a new isolation network.

The 22-bit delta-sigma ADC does not remove the need for careful analog and isolation layout. Route the differential sensing connection as a controlled pair, minimize loop area, observe the manufacturer's grounding and filtering guidance, and verify that host-generated pulses provide the timing and energy required by the supply-voltage generator. Validate settling, calibration, noise, and synchronization with the complete meter firmware rather than judging performance from converter resolution alone.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

The supplied manufacturer and distributor snippets do not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. Compliance fields remain unknown rather than inferred.

데이터 검증일: 2026-10-21 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

71M6103-IL/F 71M6103-IL/F datasheet Analog Devices 71M6103 71M6103 22-bit isolated ADC 71M6103 8-pin SOIC 71M6103 pulse transformer isolation 71M6103 three-phase energy meter 71M6103 shunt current sensing 71M6103 vs 71M6103-ILR/F 71M6103-IL/F drop-in replacement 71M6103-IL/F buy 71M6103-IL/F price 71M6103-IL/F lead time What can replace 71M6103-IL/F? Where to find the 71M6103-IL/F pinout?

관련 부품 & 용어

Analog Devices Maxim Integrated 71M6103-IL/F 71M6103 71M654x Silergy isolated sensor IC energy-metering IC 22-bit delta-sigma ADC differential-input amplifier precision voltage reference temperature sensor supply-voltage generator pulse-transformer isolation three-phase electricity meter poly-phase smart meter shunt-based current sensing current transformer replacement 8-pin SOIC surface-mount package isolated current sensing smart-grid metering obsolete component ADC/DAC
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기