AD694JNZ - 4-20mA Current Transmitter IC | Analog Devices
부품 번호: AD694JNZ ✓ 활성AD694JNZ 개요
A current transmitter is an interface IC within the broader category of sensor and detector interfaces. It bridges a voltage or current-mode input signal and a 4-20 mA process-control loop, allowing sensors, controllers, valves, actuators, and other industrial equipment to exchange analog information over a common industrial interface. The AD694 is specifically designed for controlling valves, actuators, and devices commonly used in process-control systems.
The AD694 uses an input amplifier to buffer the input signal and can scale that input or buffer the output from a current-mode DAC. This makes it suitable for systems that need calibrated signal conditioning before the signal reaches the loop transmitter. Its 4-20 mA output supports established industrial current-loop practices and helps interface field equipment with control systems.
The AD694JNZ is the commercial 0 °C to 70 °C version of the AD694 family in a through-hole 16-pin PDIP package. The JNZ ordering designation identifies the temperature range and packaging configuration. Other members of the AD694 family use different package or temperature options, so the exact suffix must be checked against PCB footprint and environmental requirements before substitution.
Typical applications include process-control transmitters, programmable current sources, closed-loop actuator systems, industrial data-acquisition equipment, and factory instrumentation. In these systems, the AD694 can accept a control signal and provide a compliant 4-20 mA output for driving remote valves, actuators, or other field devices. Its buffered input architecture can also support scaling and isolation of signals originating from a current-mode DAC.
When designing a circuit around the AD694JNZ, verify the complete signal chain against the manufacturer datasheet, including input range, loop-compliance voltage, calibration method, output drive, and pin definitions. The 36 V supply rating should not be treated as an indication that any particular loop voltage is available under all output-current conditions; loop compliance must be checked separately.
This page organizes the AD694JNZ product information, verified same-family and cross-brand alternatives, package details, practical design guidance, and application-specific engineering context into one compact engineering reference for evaluating industrial 4-20 mA signal-chain designs.
드롭인 대체품: AD694JNZ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: AD694JNZ (동일 폼 팩터 및 풋프린트) — 차이점: Product Type, Maximum Supply Voltage, Package, Input Buffer Amplifier, Package Type.
AD694JN
✅ 드롭인가격 문의
데이터시트 보기 →AD694BQ
✅ 드롭인가격 문의
데이터시트 보기 →AD694AQ
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
XTR105PA
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
AD694JNZ 사양
| Product Type | 4-20 mA current transmitter IC |
| Manufacturer | Analog Devices |
| Supported Output | 4-20 mA current loop |
| Input Signal | Buffered high-level voltage input |
| Input Architecture | Voltage input with buffered input amplifier |
| Maximum Supply Voltage | 36 V |
| Operating Supply Current | 23 mA |
| Input Bias Current | 1.5 nA |
| Number of Amplifiers | 1 amplifier |
| 패키지 | 16-pin PDIP |
| 실장 유형 | Through-hole |
| Commercial Operating Temperature | 0 °C to 70 °C |
| Extended Operating Temperature | -40 °C to 85 °C |
| 출력 유형 | Current output |
| Primary Application | Process-control signal transmission |
AD694JNZ 16-pin pdip 핀 구성 가이드
AD694JNZ(16-pin pdip 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: AD694JNZ.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
AD694JNZ 적합 용도: 6 애플리케이션s: Industrial Process-Control Transmitter, Programmable 4-20 mA Current Source, Valve and Actuator Control, Factory Data-Acquisition Equipment, Remote Sensor Interface, Closed-Loop Process Control.
Industrial Process-Control Transmitter
The AD694JNZ fits industrial process-control signal chains that require a voltage input to be converted into a standard 4-20 mA loop. Its monolithic transmitter architecture buffers the input before driving the loop, making it suitable for control signals associated with valves, actuators, and remote field equipment. The listed 23 mA operating supply current and 36 V maximum supply rating should be included in the power-budget and protection design. Before finalizing the circuit, verify input range, loop-compliance voltage, load limits, and calibration requirements in the Analog Devices AD694 datasheet.
추천
Programmable 4-20 mA Current Source
The AD694 can be used as a programmable current-source output stage when its input amplifier is driven from a suitable control or current-mode DAC. This arrangement allows a digital controller to command an analog process variable while retaining the interoperability of a standard 4-20 mA interface. The AD694JNZ is suitable where an industrial transmitter function and a 16-pin PDIP implementation are required. Engineers must confirm DAC output compatibility, signal scaling, output compliance, and loop stability so that startup or DAC transients do not exceed the device limits.
추천
Valve and Actuator Control
The AD694JNZ is applicable to valve-position and actuator-control subsystems that use 4-20 mA as the field command signal. A controller can present a scaled command voltage to the transmitter, and the AD694 converts that command into the current required by a standard industrial loop. This approach supports connection to powered field devices over wired industrial cabling. Design work should check loop resistance, available supply voltage, output compliance, grounding, shielding, and fault-state behavior against the manufacturer datasheet before the transmitter is connected to equipment.
추천
Factory Data-Acquisition Equipment
The AD694JNZ can provide the current-loop output stage in factory data-acquisition and monitoring equipment that must communicate with sensors or remote instrumentation over standardized wiring. The buffered input supports signal conditioning before the 4-20 mA output stage, helping isolate the field loop from the originating control signal. Its 16-pin PDIP format is practical for through-hole industrial and test systems. Installation should follow the pin description and recommended application circuit in the Analog Devices datasheet, including careful grounding and protection against externally connected surge or wiring faults.
추천
Remote Sensor Interface
The AD694JNZ is well matched to remote sensor-interface modules that need to translate a locally conditioned sensor or controller signal into a 4-20 mA transmission. The standard loop format supports integration with remote monitoring and control networks while the transmitter handles the required output conditioning. Its listed commercial temperature range of 0 °C to 70 °C suits controlled indoor environments. For field equipment, engineers should evaluate enclosure temperature, induced surge, cable length, grounding, and whether a wider-temperature AD694 ordering option is required.
추천
Closed-Loop Process Control
The AD694JNZ can serve as the analog field-output element in a closed-loop process-control system where a supervisory controller regulates a valve, actuator, or variable process condition. The transmitter accepts a scaled control signal and produces the corresponding 4-20 mA command used by field equipment. This arrangement separates the low-level control domain from the wired industrial loop. Design validation should include loop bandwidth, output accuracy, current compliance, failure modes, and power-supply headroom. The manufacturer datasheet should also be used to establish any required calibration procedure.
추천
추천 제품 요약
엔지니어링 참조 데이터: AD694JNZ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | AD694JN | AD694BQ | AD694AQ | XTR105PA |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP |
| Product Function | 4-20 mA current transmitter IC | AD694-family 4-20 mA current transmitter | AD694-family 4-20 mA current transmitter | AD694-family 4-20 mA current transmitter | 4-20 mA current transmitter |
| Output Type | Current output | Current output | Current output | Current output | Current output |
주요 차별점
- Exact commercial 16-pin PDIP ordering configuration (vs AD694BQ)
- Directly documented monolithic transmitter architecture (vs XTR105PA)
- 36 V listed maximum supply rating (vs AD694JN)
설계 노트
Design the supply around the listed 23 mA operating current and verify the minimum operating voltage against the Analog Devices AD694 datasheet. The 36 V value is a maximum rating, not a recommended operating point. Confirm that the power source maintains the required voltage when the 4-20 mA loop draws its maximum load current, and add protection that does not interfere with normal startup or current regulation.
Assign every PCB net from the 16-pin PDIP drawing for the exact AD694 ordering suffix. Place input, supply-decoupling, and output-loop connections in the topology shown by the manufacturer's application circuit. Keep the current-loop output path physically separate from sensitive high-impedance inputs to reduce coupling, and provide a low-impedance ground return for the transmitter and its external loop interface.
Do not assume that every AD694-family ordering code is an automatic PCB replacement. Although AD694JN, AD694BQ, and AD694AQ are related 16-pin PDIP options, the suffix may change temperature grade, qualification, or ordering configuration. Confirm pin functions, input range, output compliance, calibration method, and environmental limits before substitution. Review the XTR105PA more critically because it is a different manufacturer's implementation.
Use the Analog Devices AD694 datasheet application circuit as the basis for grounding, decoupling, and output-loop implementation. Industrial field cables can introduce surge and electromagnetic coupling, so provide appropriately rated protection at the connector boundary. The protection network must preserve loop compliance and current accuracy; verify its effect on transmitter operation rather than relying only on a generic TVS arrangement.
규정 준수 정보
The AD694 is an industrial interface IC, and no AEC-Q100 qualification was identified. Request current manufacturer declarations for the exact AD694JNZ ordering code when compliance documentation is required.