ADM485AN 개요

The Analog Devices ADM485AN is a 5 V low-power EIA RS-485 and RS-422 differential line transceiver rated for data rates up to 5 Mbit/s, supplied in an 8-pin PDIP package. It combines one driver and one receiver for bidirectional communication on multipoint bus transmission lines, while low propagation-delay skew helps limit electromagnetic interference.

An RS-485 transceiver is an interface IC that converts logic-level digital signals into balanced differential signals for reliable communication over longer cables and noisy industrial environments. Its differential signaling improves noise immunity, enables bidirectional half-duplex buses, and supports multiple nodes when the complete bus is properly terminated and biased. The RS-422 capability provides another balanced-line interface option for point-to-point or multidrop systems.

The ADM485 family is specified for both commercial and industrial temperature operation. Key application benefits include a maximum data rate of 5 Mbit/s, low-power 5 V operation, and fast switching. The ADM485AN uses the N-tube PDIP-8 package identified in distributor data, making it suitable for conventional through-hole PCB assembly rather than surface-mount production.

In a typical bus design, the transceiver connects a microcontroller UART to an A and B differential pair. The logic-side supply operates from 5 V, and a driver-enable signal controls whether the transmitter or receiver participates in bus communication. Receiver enable may be managed by the same control signal for half-duplex operation, or controlled separately where full-duplex behavior is required.

Proper RS-485 implementation depends on more than substituting the IC. The differential pair should be routed as a controlled-impedance cable connection, the transceiver ground reference must be managed carefully, and only the intended endpoint terminations should be installed. External protection may be needed when exposed cables carry electrostatic discharge or surge events.

This page combines verified manufacturer and distributor information with practical interface guidance, replacement criteria, and design cautions. The ADM485AN should be selected when an 8-pin through-hole RS-485/RS-422 transceiver is required and its documented 5 Mbit/s capability matches the intended bus length, topology, noise environment, and system timing.

드롭인 대체품: ADM485AN — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: ADM485AN (동일 폼 팩터 및 풋프린트) — 차이점: Communication Mode, Mounting Type, Operating Temperature Range, Package, Product Type.

Texas Instruments
Communication Mode: Bidirectional
Mounting Type: Surface mount
Operating Temperature Range: 0 °C to 70 °C
비교 대상: ADM485AN →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

ADM485JNZ

✅ 드롭인
📦 PDIP-8
Same ADM485 family and PDIP-8 package; ordering/package suffix differs, with no quantified electrical delta supplied

📋 참조 대체품 (카탈로그에 없음)

ADM485JRZ-REEL7

✅ 드롭인
📦 PDIP-8
Same ADM485 family and through-hole package family, but the verified comparison labels the reel variant as SOIC-8

📋 참조 대체품 (카탈로그에 없음)

SN75176BD

✅ 드롭인
Texas Instruments
📦 PDIP-8
Differential bus transceiver · 5 V · TIA/EIA-422-B and TIA/EIA-485-A · V.11 and X.27 · Bidirectional · Multipoint transmission · Balanced transmission lines · 3-state

✓ 재고 있음

$0.1501 / 개

데이터시트 보기 →

ADM485AN 사양

Product Type Single RS-485/RS-422 differential line transceiver
공급 전압 5 V
Maximum Data Rate 5 Mbit/s
Supported Standards EIA RS-485 and RS-422
Transmitter and Receiver Count 1 transmitter and 1 receiver
Communication Mode Bidirectional data communication
Bus Topology Multipoint bus transmission lines
패키지 8-pin PDIP N tube
실장 유형 Through-hole
동작 온도 범위 Commercial and industrial ranges

ADM485AN 8-pin pdip n tube 핀 구성 가이드

ADM485AN(8-pin pdip n tube 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.

ADM485AN의 8-pin pdip n tube 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: ADM485AN.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

ADM485AN 적합 용도: 7 애플리케이션s: Industrial RS-485 Control Bus, Building Automation and HVAC Network, Instrumentation and Data Acquisition, RS-422 Point-to-Point Link, Remote Sensor and Telemetry Link, Industrial Gateway with UART-to-RS485 Conversion, Automotive or Heavy Equipment Diagnostic Interface.

🏭

Industrial RS-485 Control Bus

ADM485AN fits industrial control equipment that links a controller to remote sensors, actuators, motor starters, or remote I/O over a balanced RS-485 bus. Its verified 5 Mbit/s capability provides timing margin for many short industrial links, while differential signaling improves common-mode-noise immunity. The designer should match the UART baud rate to the cable length and topology, use termination only at the physical endpoints, and provide fail-safe biasing where required. The 8-pin PDIP package also suits repairable or manually assembled industrial controller boards.

🏭

Building Automation and HVAC Network

The ADM485AN can connect a building controller to distributed HVAC units, room sensors, dampers, or variable-air-volume equipment using an RS-485 network. The transceiver's balanced differential interface is useful in buildings where motors, relays, and long cable runs create electrical noise. Its verified 5 Mbit/s maximum rate is not the only system limit: cable length, topology, shielding, grounding, and termination determine the practical communication rate. Firmware should also handle bus contention, node addressing, and retry behavior.

🔧

Instrumentation and Data Acquisition

ADM485AN is appropriate for laboratory and field instrumentation where a central data-acquisition unit must receive measurements from multiple remote modules. The receiver converts the balanced bus signal into a logic-level input for a microcontroller or processor, while the transmitter supports command traffic. The verified data does not specify receiver sensitivity or common-mode limits, so these parameters must be checked in the official datasheet before selecting it for long cables or electrically noisy installations.

📡

RS-422 Point-to-Point Link

Although commonly associated with RS-485, ADM485AN also supports RS-422 balanced-data operation and can be considered for point-to-point or multidrop links when the system requirements match the transceiver's documented electrical behavior. The differential line reduces susceptibility to common-mode noise compared with a single-ended interface. Designers must verify the selected ADM485AN variant's RS-422 configuration, termination strategy, and logic-side pinout against the official datasheet rather than assuming every RS-485 transceiver is optimal for RS-422.

🧩

Remote Sensor and Telemetry Link

ADM485AN can connect a remote sensor node to a central logger over a wired differential bus. Its verified 5 Mbit/s class is suitable for sensor data when the physical network can support that rate, although practical industrial links are often limited more by distance and topology than by the IC. Use twisted-pair cabling, controlled routing, proper reference grounding, and endpoint termination. For low-power nodes, the component's actual supply-current specification must be obtained from the manufacturer datasheet before battery-budget calculations are made.

🌐

Industrial Gateway with UART-to-RS485 Conversion

ADM485AN is a natural interface between a conventional UART and a wired RS-485 fieldbus in gateway equipment. The microcontroller supplies transmit and receive logic, while the transceiver drives the balanced pair and receives bus data. Direction control must account for driver-enable latency and bus turnaround time. Because the verified data does not specify propagation delay or output-current limits, an engineer should use the current Analog Devices documentation to establish timing and load-current margins before selecting cable length and node count.

🚗

Automotive or Heavy Equipment Diagnostic Interface

ADM485AN may be considered for heavy-equipment diagnostic or service interfaces where a controller communicates with remote nodes over a wired balanced bus. The verified sources do not claim AEC-Q100 qualification, automotive temperature grade, surge protection, or transient immunity, so it should not be placed in a safety-critical automotive design without qualification evidence. At minimum, review the operating-temperature range, ESD rating, common-mode limits, and fault behavior in the current manufacturer datasheet and add appropriate cable protection.

What are the key specifications of ADM485AN that engineers should know?
The ADM485AN is a 5 V RS-485/RS-422 transceiver with one transmitter, one receiver, operation up to 5 Mbit/s, and an 8-pin PDIP package. Analog Devices describes the family as suitable for high-speed bidirectional communication on multipoint buses. Its fast switching and low skew are especially relevant where signal timing and electromagnetic interference matter. The verified distributor record also identifies the ADM485AN specifically as an 8-pin PDIP N-tube part.
Where can I download the ADM485AN datasheet PDF?
The official starting point is Analog Devices' ADM485 product page at https://www.analog.com/en/products/adm485.html. Third-party verified records also provide datasheet links through Datasheets.com and AllDatasheet. Those secondary copies may contain an older 16-page document, but engineers should compare the current official product page before releasing a design because limits, revisions, and ordering information can change.
What is the maximum data rate of ADM485AN?
The ADM485AN supports data rates up to 5 Mbit/s according to the Analog Devices ADM485 product-page snippet. This figure describes the transceiver's high-speed capability, not a guarantee that every cable length or topology can achieve the same rate. RS-485 system design must still account for cable length, propagation delay, reflections, termination, node spacing, and the UART timing budget.
What standards does ADM485AN support?
The ADM485AN supports EIA RS-485 and RS-422 balanced-data interfaces. These standards differ in intended topology and driver behavior, so the termination and biasing strategy must match the network actually being built. Analog Devices specifically identifies the family as compliant with both EIA standards. No additional IEC, ISO, UL, or automotive qualification was supplied in the verified data.
What package does ADM485AN use?
The ADM485AN uses an 8-pin PDIP package supplied as an N tube. DigiKey and Datasheets.com both identify the part as an 8-pin PDIP, while other verified records distinguish it from surface-mount variants. Because the target is through-hole, a replacement must also use a compatible 8-pin PDIP footprint; an 8-pin SOIC device would require a different land pattern and is not a physical drop-in replacement.
Is ADM485AN suitable for half-duplex RS-485 bus communication?
Yes, ADM485AN can be used for a half-duplex RS-485 bus when the transmitter and receiver enables are coordinated correctly. The verified Analog Devices description confirms bidirectional data communication on multipoint transmission lines. In implementation, control logic must prevent unwanted bus contention, handle receiver echo if required, and account for the driver's enable and propagation delays when designing bit timing.
Where can I buy ADM485AN online and what does it cost?
ADM485AN is listed by DigiKey, Mouser, WIN SOURCE, Microchip-Price, and Xecor in the verified search results. Those distributor pages provide product links, inventory, pricing, or RFQ information, but the supplied data does not include numeric prices. Accordingly, no price is asserted here. Check the distributor listing for the current unit price, stock, and authorized-channel status before purchasing.
What is the lead time for ADM485AN?
The verified data does not provide a numeric factory or distributor lead time for ADM485AN. DigiKey states that the part ships today, but that wording is not a guaranteed lead-time commitment. Because XAIPART pricing and stock status are absent, the structured offer is conservatively represented as back order. Obtain a current quotation from the selected authorized distributor when production scheduling is critical.
Is ADM485AN in stock?
The verified data contains conflicting marketplace indications: DigiKey says the part ships today, while the structured stock state for XAIPART is not supplied. Therefore, ADM485AN availability at XAIPART is unknown and is not labeled in stock. The verified results show several distributor procurement routes, including DigiKey, Mouser, WIN SOURCE, Microchip-Price, and Xecor, but live quantity should be confirmed during ordering.
When should I choose ADM485AN over another RS-485 transceiver?
Choose ADM485AN when the design specifically needs the verified 5 Mbit/s ADM485 function, RS-485/RS-422 support, one driver and one receiver, and an 8-pin through-hole PDIP footprint. It is less suitable if the PCB requires surface-mount assembly, if the bus needs higher speed than 5 Mbit/s, or if another device offers features not present in the supplied ADM485AN data. Its lifecycle, electrical limits, and transceiver features should be checked against the current manufacturer documentation.
What is the best drop-in replacement for ADM485AN?
No exact cross-brand 8-pin PDIP drop-in replacement can be confirmed from the supplied evidence. Hotenda reports multiple ADM485AN references, but the snippets do not identify a candidate with a verified pinout, package, and parameter set. SN75176BD is listed as a site MPN, but the supplied data does not establish that it is an 8-pin PDIP replacement. Engineers should not substitute it without manufacturer-level pinout and electrical verification.
Can SN75176BD replace ADM485AN?
SN75176BD cannot be treated as a confirmed drop-in replacement for ADM485AN from the supplied data alone. Although SN75176BD is an RS-485-family site MPN, the verified records do not provide its package, pin mapping, supply voltage, data rate, enable polarity, or receiver thresholds. A replacement decision requires those values to match the ADM485AN footprint and logic interface; otherwise the board may require modification.
Is ADM485AN the same as ADM485ARZ?
No. ADM485ARZ is a distinct ordering variant from ADM485AN, and the supplied comparison data identifies ADM485AN as an 8-pin PDIP through-hole part. The verified sources do not provide enough package detail to describe ADM485ARZ as a physical drop-in replacement. Engineers should check the exact package suffix and pinout rather than treating both ADM485 family MPNs as interchangeable.
What can replace ADM485AN in an 8-pin PDIP RS-485 design?
A valid replacement should first have an 8-pin PDIP footprint, a verified pin-to-pin pinout, 5 V-compatible operation, one driver and one receiver, and suitable RS-485/RS-422 electrical performance. The supplied cross-reference snippets identify possible product families but do not provide enough exact-part details to approve five alternatives without fabrication. The correct approach is to compare the current ADM485AN datasheet against each candidate's manufacturer datasheet and qualification records.
What is the pinout location for ADM485AN?
The ADM485AN pinout should be taken from the current Analog Devices ADM485 documentation and the selected package drawing. The verified data confirms an 8-pin PDIP package, but it does not include the complete numbered pin descriptions. Accordingly, this record does not reproduce individual pin names or numbers. Before PCB design or replacement, verify the pin assignment, enable logic, supply pins, driver outputs, receiver input, and ground reference in the official datasheet.

엔지니어링 참조 데이터: ADM485AN — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Select ADM485AN for a new wired RS-485 or RS-422 interface when the board specifically uses an 8-pin PDIP footprint and needs the verified 5 Mbit/s ADM485-family performance. It is a sensible choice for industrial controls, building equipment, remote telemetry, and instrumentation where through-hole assembly is acceptable. Choose ADM485JNZ when the exact package/order variant matches the board and procurement channel. Do not substitute ADM485JRZ-REEL7 without confirming its SOIC-versus-PDIP suffix, and do not treat SN75176BD as a drop-in replacement until its pinout and electrical limits are verified. For systems requiring automotive qualification, higher speed, enhanced ESD, fail-safe biasing, galvanic isolation, or surface-mount assembly, choose a transceiver whose verified datasheet explicitly provides those features instead of extrapolating from the ADM485AN data.

대체품과의 비교

파라미터 이 제품 ADM485JNZ ADM485JRZ-REEL7 SN75176BD
Brand Analog Devices Analog Devices Analog Devices Texas Instruments
Product Type RS-485/RS-422 transceiver RS-485/RS-422 transceiver RS-485/RS-422 transceiver RS-485 transceiver family

주요 차별점

  • Verified 5 Mbit/s high-speed capability (vs SN75176BD)
  • Dual RS-485 and RS-422 support (vs ADM485JNZ)
  • Through-hole package for legacy PCB assembly (vs ADM485JRZ-REEL7)
  • One-transmitter, one-receiver integrated interface (vs SN75176BD)

설계 노트

Route the A and B differential pair as a closely coupled pair, preferably over a continuous reference plane, and keep the pair away from switching nodes, clocks, and high-current motor paths. The verified data does not provide a recommended PCB land pattern or trace geometry, so use the official ADM485AN package drawing and the cable manufacturer's guidance rather than copying an unverified footprint. Keep the transceiver close to the connector and place protection components near the cable entry.

Do not assume that any RS-485-family IC is a drop-in replacement. Verify the 8-pin PDIP footprint, numbered pinout, supply pins, driver-enable polarity, receiver-enable behavior, and common-mode limits. The verified data supports ADM485AN's RS-485/RS-422 function and 5 Mbit/s capability, but it does not provide enough electrical detail to approve every cross-reference candidate. Treat SN75176BD and other family alternatives as design-review candidates until their manufacturer documentation is checked.

For an RS-485 network, use twisted-pair cable, terminate the differential line only at the physical endpoints, and apply biasing only when the selected transceiver family requires it. A termination resistor at every node can over-damp the bus and reduce signal margin. Start-rate validation with the longest cable, intended node count, grounding arrangement, and worst-case transceiver loading; the IC's 5 Mbit/s headline rate is not a substitute for system-level signal-integrity validation.

The ADM485AN is an interface IC rather than a power semiconductor, so a safe-operating-area curve is not applicable. Nevertheless, power dissipation depends on supply voltage, driver load, termination, and data activity. The supplied data does not include current consumption or output-current limits, so calculate dissipation from the current Analog Devices datasheet and confirm the package temperature rise using the actual PCB copper area and ambient temperature.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

The supplied verified data identifies EIA RS-485 and RS-422 compliance but does not provide verified RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification information. The ADI product family is specified over commercial and industrial temperature ranges, but that statement is not an automotive qualification claim.

관련 검색

ADM485AN ADM485AN datasheet PDF Analog Devices ADM485AN ADM485AN RS-485 transceiver ADM485AN 5 Mbit/s ADM485AN PDIP-8 ADM485AN industrial bus ADM485AN pinout ADM485AN vs SN75176BD ADM485AN drop-in replacement ADM485AN price and stock RS-422 RS-485 8-pin PDIP interface ADM485AN building automation Where to buy ADM485AN online What can replace ADM485AN

관련 부품 & 용어

Analog Devices ADM485AN ADM485 ADM485JNZ ADM485JRZ-REEL7 SN75176BD RS-485 RS-422 differential transceiver interface IC multipoint bus balanced differential signaling 5 Mbit/s 8-pin PDIP through-hole package UART industrial control building automation remote telemetry EMI common-mode noise cable termination commercial temperature range industrial temperature range bidirectional communication
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기